}

Rate Contract Of Supply Of Angioplasty , Angiography Items, Member Secretary RMRS MBGH Udaipur-Rajasthan

Medical College-MC has published Rate Contract Of Supply Of Angioplasty , Angiography Items. Submission Date for this Tender is 16-03-2020. Medicine Tenders in Member Secretary RMRS MBGH Udaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

23746964
Rate Contract Of Supply Of Angioplasty , Angiography Items
National Competitive Bid
Indian
Rajasthan
Member Secretary RMRS MBGH Udaipur
16-03-2020

Tender Details

Rate Contract Of Supply Of Angioplasty , Angiography Items-2 Radial Introducer Sheath 5Fr. Compatible With 6 Fr Guiding Catheter • Standard Length N• Pack Must Include 18 G, 6-7.5 Cm Long Puncture Needle N• 0.035 Or 0.038 Inch Guide Wire Compatible N• With Haemostatic Valve To Prevent Back Leak And Air Aspiration N• Integral Side Port With Attached 3-Way Stopcock N• With Suture Eye For Securing Sheath N• Kink Resistant N• With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion N• With Smooth And Resistance Free Insertion N 3 Introducer Sheath With Puncture Needle For Adults ( Size 4 Fr.- 9Fr. ) ( Standard Length ) N• Sizes 4 French / 5 French / 6 French / 7 French / 8 French / 9 French. N• 10-11 Cm Long N• Pack Must Include 18 G, 6-7.5 Cm Long Puncture Needle N• 0.035 Or 0.038 Inch Guide Wire Compatible N• With Haemostatic Valve To Prevent Back Leak And Air Aspiration N• Integral Side Port With Attached 3-Way Stopcock N• With Suture Eye For Securing Sheath N• Kink Resistant N• With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion N• With Smooth And Resistance Free Insertion N 4 Radial Glide Sheath Introducer Sheath With Outer Diameter One Fr Size Under. ( 6 Fr Sheath With Outer Dia Of 5 Fr ) N• Sizes 5 French / 6 French / 7 French / 8 French / 9 French. N• Sheath Should Be Between 20-30 Cm Long N• 0.035 Or 0.038 Inch Guide Wire Compatible N• With Haemostatic Valve To Prevent Back Leak And Air Aspiration N• Integral Side Port With Attached 3-Way Stopcock N• With Suture Eye For Securing Sheath N• Kink Resistant N• With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion N• With Smooth And Resistance Free Insertion N 5 Long Introducer Sheath ( 20-30 Cm Long ) ( Size 5Fr.-9Fr. ) N• Sizes 5 French / 6 French / 7 French / 8 French / 9 French. N• Sheath Should Be Between 20-30 Cm Long N• 0.035 Or 0.038 Inch Guide Wire Compatible N• With Haemostatic Valve To Prevent Back Leak And Air Aspiration N• Integral Side Port With Attached 3-Way Stopcock N• With Suture Eye For Securing Sheath N• Kink Resistant N• With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion N• With Smooth And Resistance Free Insertion N 6 Long Introducer Sheath ( 20-30 Cm Long ) ( Size 10Fr.-11Fr. ) N• 10 French & 11French N• Sheath Should Be Between 20-30 Cm Long N• 0.035 Or 0.038 Inch Guide Wire Compatible N• With Haemostatic Valve To Prevent Back Leak And Air Aspiration N• Integral Side Port With Attached 3-Way Stopcock N• With Suture Eye For Securing Sheath N• Kink Resistant N• With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion N• With Smooth And Resistance Free Insertion N 7 Trans Radial Introducer Sheaths 4F-6F – N• Sizes 4 French / 5 French / 6 French. N• 10-20 Cm Long N• Pack Must Include 18 G, 6-7.5 Cm Long Puncture Needle N• 0.025 Inch Guide Wire Compatible N• With Haemostatic Valve To Prevent Back Leak And Air Aspiration N• Integral Side Port With Attached 3-Way Stopcock N• With Suture Eye For Securing Sheath N• Kink Resistant N• With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion N• With Smooth And Resistance Free Insertion N 8 Steerable Introducer Sheaths 5F-6F N• Sizes 5 F / 6 F / 7 / 8F / 9F / 10F / 11F / 12 F N• Size 55 To 90 Cms N• To Provide Greater Access To Reaching Target N• With Ergonomic Handle Design N• Movable Tip For Different Curves And Torquability To Ready N• Vessel N 9 Long Braded Introducer Sheath – N• Sizes 6 French / 7 French / 8 French 9 French And Above N• Should Be 90 Cm And Above N• 0.021 Or 0.025 Inch Guide Wire Compatible N• With Haemostatic Valve To Prevent Back Leak And Air Aspiration N• With Integral Side Port With Attached 3-Way Stopcock N• With Suture Eye For Securing Sheath N• Kink Resistant N• With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion N 10 Angio Seal Type Vascular Closure Device With Collagen. 6 And 8 Fr 11 Long Introducer Sheath ( 30-50 Cm Long ) ( Size 5Fr.-9Fr. ) N• Sizes 5 French / 6 French / 7 French / 8 French / 9 French N• Between 30-50 Cm Long N• 0.035 Or 0.038 Inch Guide Wire Compatible N• With Haemostatic Valve To Prevent Back Leak And Air Aspiration N• Integral Side Port With Attached 3-Way Stopcock N• Kink Resistant N• With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion N• With Smooth And Resistance Free Insertion 12 Long Braded Introducer Sheath - N• Sizes 5 French / 6 French / 7 French / 8 French N• Between 30-50 Cm Long N• 0.021 Or 0.025 Inch Guide Wire Compatible N• With Haemostatic Valve To Prevent Back Leak And Air Aspiration N• With Integral Side Port With Attached 3-Way Stopcock N• With Suture Eye For Securing Sheath N• Kink Resistant N• With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion N• Should Have Smooth And Resistance Free Insertion N 13 Long Introducer Sheath – N• Sizes 5 French / 6 French / 7 French / 8 French N• Should Be 90 Cm And Above N• 0.021 Or 0.025 Inch Guide Wire Compatible N• With Haemostatic Valve To Prevent Back Leak And Air Aspiration N• With Integral Side Port With Attached 3-Way Stopcock N• With Suture Eye For Securing Sheath N• Kink Resistant N• With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion 14 Long Contra Lateral Introducer Sheath – N• Sizes 6 French / 7 French / 8 French 9 French And Above N• Should Be 90 Cm And Above N• 0.021 Or 0.025 Inch Guide Wire Compatible N• With Haemostatic Valve To Prevent Back Leak And Air Aspiration N• With Integral Side Port With Attached 3-Way Stopcock N• With Suture Eye For Securing Sheath N• Kink Resistant N• With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion N 15 Ptfe Coated Diagnostic Guide Wire – ( Regular Length, Regular Stiffness ) - N• Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size N• Should Be Between 145-180 Cm Long N• Should Be Available As Straight & J-Shaped Tip N• Should Be Available In Variable Lengths Of Flexible / Floppy End N• Should Be Available In Variable J Tip Sizes N• Should Be Available Fixed As Well As Movable Core. N 16 Ptfe Coated Diagnostic Guide Wire – ( Exchange Length, Regular Stiffness ) N• Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size N• Should Be 240-300 Cm Long N• Should Be Available As Straight Or J-Shaped Tip N• Should Be Available Fixed As Well As Movable Core. N 17 Ptfe Coated Diagnostic 0.032 Inch Guide Wire – ( Regular Length, Extra Stiff Shaft Strength ) -Amplatz Type - N• Should Be Available In 0.032 / 0.035 / 0.038 Inches Size N• Should Be Between 145-180 Cm Long N• Should Be Available As Straight & J-Shaped Tip N 18 Ptfe Coated Diagnostic 0.032 Inch Guide Wire – ( Exchange Length, Extra Stiff Shaft Strength ) -Amplatz Type - N• Should Be Available In 0.032 / 0.035 / 0.038 Inches Size N• Should Be Between 240-300 Cm Long N• Should Be Available As Straight & J-Shaped Tip N 19 Hydrophilic Diagnostic Guide Wire – Radifocus Terumo Type ( Regular Length, Regular Stiffness ) – N• Must Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size N• Should Have Superelastic Alloy Core N• Should Have Super Flexible Wire Tip N• Should Be Available In Straight And Angled Tip N• Should Be Between 120-300 Cm Long N 20 Radiofocus Miniplastic Guidewire ( , Regular Stiffness ) – N• Must Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size N• Should Have Superelastic Alloy Core N• Should Have Super Flexible Wire Tip N• Should Be Available In Straight And Angled Tip N• Should Be Between 150-180 Cm Long N N N 21 Radiofocus Miniplastic Guidewire ( Long Length ) – N• Must Be Available In 0.025, 0.032 And 0.038 Inches Size N• Should Have Superelastic Alloy Core N• Should Have Super Flexible Wire Tip N• Should Be Available In Straight And Angled Tip N• Should Be Between 260Cm, 300 Cm Long N 22 Judkins Catheter ( Jr Jl & Pigtail ) N• 4 French / 5 French / 6 French / 7 French / 8French Size Left And Right Judkins Catheters In Various Standard Curves And Lengths.• Must Be 23 Multipurpose Catheter N• 4 French / 5 French / 6 French / 7 French / 8French Size Multipurpose Catheters In Various Standard Curves And Lengths. N• Must Be 24 Amplatz Catheter N• 4 French / 5 French / 6 French / 7 French / 8French Amplatz Left ( Al ) And Amplatz Right ( Ar ) Catheter In Various Standard Curves And Lengths. • Must Be N 25 Internal Mammary Catheter N• 4 French / 5 French / 6 French / 7 French / 8French In Various Standard Curves And Lengths. • Must Be N 26 Transradial Diagnostic Coronary Catheter Tiger Optitorque – N• 4 French / 5 French / 6 French / 7 French / 8French Diagnostic Coronary Catheters Of Various Curves And Lengths Dedicated For Trans Radial Coronary Angiography And Brachial Approach Also • Must Be N 27 Nih Catheter N• 4 French / 5 French / 6 French / 7 French / 8French In Various Standard Curves And Lengths. N• Must Be N 28 Cournand Catheter N• 4 French / 5 French / 6 French / 7 French / 8French In Various Standard Curves And Lengths. • Must Be N 29 Injection Nikorandil ( 2 Mg ) 30 Injection Bivaluridin 31 Injection Tirofibian 32 Injection Eptifibatide – 20 Mg 33 Injection Eptifibatide – 75 Mg 34 Injection Abciximab 35 Injection Fondaparinux 36 Injection Tenecteplase 30 Mg 37 Injection Tenecteplase 40 Mg 38 Injection Reteplase 18 Mg 39 Injection Alteplase 40 Tablet Ticagrelor 90 Mg 41 Tablet Prasugrel 10 Mg 42 Introducer Sheaths For Pediatric Use ( Size 4-6 Fr. ) With Nj Tip / Straight Introducer Wire - N• Sizes 4 French / 5 French / 6 French N• Between 5.5-7.5 Cm Long N• 0.021 Inch Straight Introducer Guide Wire N• With Haemostatic Valve To Prevent Back Leak And Air Aspiration N• With Integral Side Port With Attached 3-Way Stopcock N• With Suture Eye For Securing Sheath N• Kink Resistant N• With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion N• Should Have Smooth And Resistance Free Insertion N 43 Pigtail Catheter ( Pediatric ) - N• Sizes 3 French / 4 French / 5 French / 6 French N• Smaller Length For Neonatal And Pediatric Use N• Must Be N 44 Judkins Catheter Optitorque. Left & Right - N• 4 F / 5 F / 6 F Size Left And Right Judkins Catheters In Various Standard Curves And Lengths N• Must Be 45 Multipurpose Catheter ( Pediatric ) – N• 4 Fr / 5 Fr / 6 Fr In Various Standard Curves And Lengths N• Must Be N 46 3- ‘French’ Diagnostic Catheters For Neonatal Use - N• Pigtail, Judkins, Multipurpose, Cobra And Other Diagnostic Catheters Of 3 Fr. Size N• Varying Lengths And Shapes N 47 Special Swan Ganz Catheter With Safety Wedge : - N• 4 F Catheter Should Allow The Passage Of At Least 0.021 Inch, 5 F – 0.025 Inch, 6 F – 0.035 Inch And 7 F, 8F – 0.038 Inch Hydrophilic Guide Wire N• Must Be Available In 4F, 5F, 6F And 7F And 8 Fr. Sizes N• Catheter Should Be Tapered At Tip To Ensure Uniform Diameter Of The Whole Catheter N• 10 Cm Marking Along Catheter Body To Confirm Insertion Depth N 48 Berman Catheter - N• Must Be Available In 4F, 5F, 6F And 7F Sizes N• Should Have 6-8 Holes Proximal To The Balloon For Dye Injection N• Catheter Should Be Tapered At Tip To Ensure Uniform Diameter Of The Whole Catheter N• 10 Cm Marking Along Catheter Body To Confirm Insertion Depth N 49 Arterial Pressure Monitor Lines ( 100, 150 & 200 Cm Long ) - N• Should Be Soft And Kink Resistant N• Should Give Reliable Pressure Measurements N• Should Be Available In Sizes Of 100, 150 & 200 Cm N• Should Have Male Luer Lock Connection At One End And A Female Luer Lock Connection At The Other End N• Should Meet Highest Medical Industrial Standards For Arterial Pressure Lines N• Quality Certification Should Be Provided From Authorized Agencies. N 50 Act Cartridge - N• Disposable Act Tubes Compatible With Existing Act -Ii / Act Plus Machines At Rnt Medical College, • Should Meet Highest Medical Industrial Standards N• Quality Certification Should Be Provided From Authorized Agencies. N 51 Adjustable Hemostasis Valve For Catheters - N• Should Meet Highest Medical Industrial Standards N• Quality Certification Should Be Provided From Authorized Agencies. N 52 High – Presure Injector Lines - N• Should Be Available In Various Lengths N• Should Have Male And Female Luer Locks N• Should Be Transparent And Kink Resistant N• Should Be Able To Take High Pressure Of Angiographic Injections N 53 Disposable Ecg Electrodes For Adults - N• Adult Diaphoretic Foam Electrodes. N• Should Be Pre-Gelled, Peel And Stick Electrode With Excellent Adhesion N• Should Have No Residue Once Removed N• Should Conform To Or Exceed The Highest Industrial Standard For Ecg Electrodes, Quality Certification From Authorized Agencies To Be Provided N 54 Special Radiolucent Disposable Ecg Electrodes For Adults - N• Radiolucent Electrodes For Electro-Physiologic Studies N• Wet Gel Electrodes N• Should Be Porous And Breathable N• Should Conform To Or Exceed The Highest Industrial Standard For Ecg Electrodes, Quality Certification From Authorized Agencies To Be Provided N 55 Syringe For Pressure Injector Installed In Rnt Medical College, Udaipur - N• Should Be Compatible With Existing Machines At Rntmc N 56 Disposable Transducers For Invasive Pressure Monitoring Compatible With Available System In Rnt Medical College, Udaipur .- N• Disposable Transducers For Invasive Pressure Monitoring N• Should Be Compatible With Available System In . ( Iabp – Data Scope &. Transducer ) And Iccu At Rntmc N• Should Meet Highest Medical Industrial Standards N• Quality Certification Should Be Provided Form Authorized Agencies N 57 Domes For Transducer For Invasive Pressure Monitoring - N• Should Be Compatible With Existing Available System At . And Ccu At Rntmc N• Should Meet Or Exceed Highest Standards N• Quality Certification From Authorized Agencies To Be Provided N 58 Endomyocardial Biopsy ( Emb ) Forceps Set - Nset Should Include N• Should Include An Endomyo-Cardial Biopsy Foreeps And Compatible Pre-Shaped Introducer Sheath With Side Arm And Its Dilator N• Variable Lengths And Sizes N• Should Be Available For Both For Jugular And Femoral Access N 59 Intravascular Retriever – Snare ( ‘Amplatz Gooseneck’ Type ) - Nsnare Kit Should Include N• A Snare And Its Compatible Sheath N• Should Have Nitinol Shaft N• Should Have 90 Degree Preformed Snare Loop N• Variable Sizes Of Loop ( 5-35 Mm ) N 60 Sheaths For Intravascular Snares - N• Should Be Compatible With Above Mentioned Items 61 Intravascular Retriever – Microsnare ( Amplatz Gooseneck’ Type ) - Nmicrosnare Kit Should Include N• A Microsnare, Compatible Micro – Catheter, Micro – Catheter Introducer And A Torque Device N• Should Have Nitinol Shaft N• Should Have 90 Degree Preformed Snare Loop N• Variable Sizes ( 2-7 Mm ) N 62 Accessories For Intravascular Microsnare N• Should Be Compatible With Item No. 174 N 63 Intravascular Retriever – Basket - Nset Should Include N• Basket Retriever And Its Catheter N• Should Be Available In All Sizes N 64 Non Ionic ( Low Osmolar ) Contrast Agents In Plastic Bottle Used During Cardiac Catheterization - N• Sterile 350Mg Iohexol / Ml Strength Non-Ionic Contrast Agent N• Supplied In 100 Ml Sealed Plastic Vial With Hanger That Can Be Used For Dispensing Contrast During Cardiac Catheterization N 65 Non Ionic ( Isoosmolar ) Contrast Agents In Plastic Bottle Used During Cardiac Catheterization - N• Sterile 320 - 350 Mg / Ml Iodixanol Strength Non-Ionic Contrast Agent For Crf & Lvf Patients. N• Contrast For Patient With Renal Dysfunction N• Supplied In 100 Ml Sealed Vial With Hanger That Can Be Used For Dispensing Contrast During Cardiac Catheterization N 66 Renal Double Curve Catheter - N• In Various Standard Lengths And Curves N 67 Head Hunter Catheter - N• In Various Standard Lengths And Curves N• 035-038 Compatible, • 100 Cm Long N 68 Simmons / Sidewinder Catheter - N• In Various Standard Lengths And Curves N• 035-038 Compatible, • 100 Cm Long N 69 Preshaped Catheter For Uterine Artery Embolisation - N• In Various Standard Lengths And Curves N 70 Vertebral Catheter - N• In Various Standard Lengths And Curves N 71 Coeliac Axis Catheter - N• In Various Standard Lengths And Curves N 72 Shepherd’S Hook Catheter - N•• In Various Standard Lengths And Curves N 73 Micro Catheter ( Coiled Stainless Steel Construction ) - N• In Various Standard Lengths And Curves N• 2-3.8 F Size N• .010-.022 Inch Wire Compatible N• With Radio-Opaque Marker At Tip N 74 Microcatheter ( Braided Nitinol Construction ) - N• In Various Standard Lengths And Curves N• 2-3.8 F Size N• .010-.022 Inch Wire Compatible N• With Radio-Opaque Marker At Tip N 75 Angiographic Sizing Pigtail Catheter 5F / 6F / 7F 76 Straight Long Introducer Sheath With Hydrophilic Introducer Guide Wire - N• Sizes From 4French / 5French / 6French / 7French / 8French / 9French N• 16 Cm & Above Long Length N• With 0.035 Or 0.038 Inch Hydrophilic Mini Guide Wire N• With Plastic Cannula For Arterial Puncture N 77 Straight Reinforced Sheath With Hydrophilic Coating – N• Sizes From 6French / 7French / 8French / 9French / 10French / 11 French / 12 French N• More Than 60 Cm Long With Side Arm Port N• With 0.035 Or 0.038 Inch Guide Wire Compatible N• With Radio-Opaque Tip N 78 Guiding Catheter For Peripheral Vascular Use – N• Should Be Braided With Low Friction Inner Layer N• Should Have Atraumatic Soft Tip N• Should Be Available In Various Tip Shapes And Curves For Access To Different Parts Of The Peripheral Vasculature, Including Renal Double Curve, Cobra, Multi – Purpose And Other Shapes N• Should Have Od Of 6F-8F Available N• Should Have The Largest Id For Each Od N• Should Have Lengths Ranging From 55-90 Cm N 79 Long Sheath For Contra – Lateral Iliac / Femoral Access – N• Should Be Kink Resistant With A Reinforcement Mechanism N• Should Be Low Friction With Inner Coating To Allow Catheter Manipulation N• Should Have Distal Radio-Opaque Tip For Enhanced Visibility On Fluoroscopy N• Should Have Smooth Transition From Dilator To Seath N• Should Have A Proximal Hemostasis Valve / Provision For Tuohyborst Valve N• Shove Be Color Coded For Size Identification N• Should Be Available In 4F – 9 F Size With The Largest Id N• Should Have Lengths Ranging From 40-110 Cm N 80 Transradial Guiding Catheter Right Curve / Left Curve – N• Should Be Braided With Low Friction Inner Layer N• Should Have Atraumatic Soft Tip N• Should Be Available In Various Tip Shapes And Curves For Access To Different Parts Of The Peripheral Vasculature, Including Renal Double Curve, Cobra, Multi – Purpose And Other Shapes N• Should Have Od Of 6F-8F Available N• Should Have The Largest Id For Each Od N• Should Have Lengths Ranging From 55-90 Cm N 81 Renal Guiding Catheter / Renal Guiding Catheter Double Curve / Renal Guiding Catheter Single Curve – N• Should Be Braided With Low Friction Inner Layer N• Should Have Atraumatic Soft Tip N• Should Be Available In Various Tip Shapes And Curves For Access To Different Parts Of The Peripheral Vasculature, Including Renal Double Curve, Cobra, Multi – Purpose And Other Shapes N• Should Have Od Of 6F-8F Available N• Should Have The Largest Id For Each Od N• Should Have Lengths Ranging From 55-90 Cm N 82 Mother & Child Catheter – Nwith Reliable Support With Large Inner Lumen And Inner Ptse. N 83 Intubation Catheter For Assisting Delivery Of Stent In Difficult Antomies 84 Re-Entry Catheter For Cto For Coronary – 85 Re-Entry Wire For Cto For Coronary – 86 Re-Entry Balloon With Two Exit Port For Cto For Coronary 87 Drug Delivery / Infusion Catheter - 88 Coronary Probing Catheter - 89 Coronary Perfusion Catheter - 90 Coronary Trapeer Catheter - 91 Wire 0.018” Regular Length, Regular Shaft Stiffness - • Floppy Tip, • Straight / J Shaped Tip, • 140-300Cm Long N 92 Wire 0.018” Regular Length, Extra – Stiff Shaft - N• Floppy Tip, • Straight / J Shaped Tip, • 140-300Cm Long N 93 Special Balloon Catheter Compatible With 4 French Sheath - N• Compatible With 0.018 Inch Guide Wire N• Varying Length And Diameter N 94 Ptca Inflation Device - N• Efficient Locking System To Maintain High Pressure N• Rapid Inflation And Deflation N• Clear Barrel For Easy Visualization Of De-Bubbling N• Luminescent Analog Pressure Gauge ( Up To 30 Atm ) N• Ergomatric And Use Friendly Hand Held Design. N 95 Ptca Inflation Device N• Efficient Locking System To Maintain High Pressure N• Rapid Inflation And Deflation N• Clear Barrel For Easy Visualization Of De-Bubbling N• Luminescent Analog Pressure Gauge ( Up To 40 Atm ) N• Ergomatric And Use Friendly Hand Held Design. N 96 High Pressure Ptca Inflation Device Analog Pressure Gauge Upto 55 Atm 97 Tuohy Borst ( Haemostatic Y-Connector ) For Ptca – Push Mechanism - N• Should Accommodate Virtually All Interventional Devices N• Luer Connector At The Guiding Catheter End N• Rotating Adapter At The Guiding Catheter End N• Should Have Bleed Back Safety Mechanism N• Stepwise Control For Open, Semi-Open And Closed Position N 98 Tuohy Borst – Double ( Haemostatic Y-Connector ) For Bifurcation Ptca - N• Two Ports For Insertion Of Interventional Devices N• Luer Connector At The Guiding Catheter End N• Rotating Adapter At The Guiding Catheter End N 99 Radial Compression Band ( Tr Band Type ) - N• Special Two Balloondesigned For Spot Compression Of Radial Puncture Site. N 100 Manifold With Attached Tubings ( Angio Kit ) With 3 Port - N• Three Side Port Manifold N• One Connector Tubing For Connecting Manifold To Tuohy Borst N• One Luer Lock Control Syringe ( 10 Or 12 Ml ) For Contrast Injection N• Two Large Bore Tubing ( With Flow Regulating Knob ) For Withdrawing Contrast &Sline N• One Three Way Stop-Cock N 101 Ptca Guiding Catheter Heartrail– Sizes Of 5Fr., 6Fr., 7Fr. And 8Fr. N• All Possible Shapes Including Catheter : Judkings / Femoral Left And Right, Extra Back Up Support, Amplatz, Voda, Multipurpose, Hockey Stick, Trans-Radial Interventions, Bypass-Graft / Lima Interventions And Others N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm ) & Regular Length Sizes. N• Should Also Have Availability Of Catheters With Side Holes N• Should Also Have Short Tip Catheters N 102 Ptca Guiding Catheter – N• Sizes Of 5Fr., 6Fr., 7Fr. And 8Fr. N• All Possible Shapes Including Catheter : Judkings / Femoral Left And Right, Extra Back Up Support, Amplatz, Voda, Multipurpose, Hockey Stick, Trans-Radial Interventions, Bypass-Graft / Lima Interventions And Others N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm ) & Regular Length Sizes. N• Should Also Have Availability Of Catheters With Side Holes N• Should Also Have Short Tip Catheters N 103 Ptca Guide Wire – Regular Length, Regular Shaft Support And Floppy Tip 104 Ptca Guide Wire – Regular Length, Extra - Support Shaft And Floppy Tip 105 Ptca Guide Wire – Exchange Length 106 Ptca Guide Wire – Hydrophilic Coated, Regular Length 107 Ptca Guide Wire – Hydrophilic Coated, Exchange Length 108 Special Ptca Guide Wires With Elastinite Core And Stainless Steel Shaft Support N• Both Regular And Exchange Length Wires N• Should Have Wires With Varying Degree Of Shaft Support N 109 Special Ptca Guide Wire With Dual Coating Nshould Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating. Nshould Have Wires With Variable Tip Stiffness And Variable Shaft Support . N 110 Special Ptca Guide Wire With Multiple Markers For Measuring The Length Of Stenotic Segment 111 Ptca Guide Wires For Chronic Total Occlusion ( Cto ) - 112 Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length ) - N• 0.014 Inches , • Nitinol Alloy , • With Angled Tip -3-5 Cm Long N• Tip With Platinum / Platinum Alloy For Optimum Visualization N• With Tfe Coating , • 180 Cm Long N 113 Heavy Duty Nitinol Alloy Extra Support Wire ( Exchange Length ) N• 0.014 Inches N• Nitinol Alloy N• With Angled Tip -3-5 Cm Long N• Tip With Platinum / Platinum Alloy For Optimum Visualization N• With Tfe Coating N• 270-300 Cm Long N 114 Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length ) N• 0.018 Inches N• Nitinol Alloy N• With Angled Tip -3-5 Cm Long N• Tip With Platinum / Platinum Alloy For Optimum Visualization N• With Tfe Coating , • 180 Cm Long N 115 Heavy Duty Nitinol Alloy Extra Support Wire ( Exchange Length ) - N• 0.018 Inches N• Nitinol Alloy N• With Angled Tip -3-5 Cm Long N• Tip With Platinum / Platinum Alloy For Optimum Visualization N• With Tfe Coating , • 270-300 Cm Long N 116 Steerable High Support .014 Inch Guidewire - N• Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long N• Straight And J Curve, • 180 Cm Long N 117 Steerable High Support .014 Inch Guidewire ( Exchange ) - N• Ptfe / Duraglide Coated , • Distal Radio-Opaque Tip 3 Cm Long N• Straight And J Curve, • 260-300 Cm Long N 118 Ptca Wires With Facility Of Boot Links For Extension Of Regular Wire - 119 Exchange Length Ptca Wire With Marker With – Sizes – 0.035” , 0.038”, 0.018” & 0.014” 120 Special Non-Tapering Ptca Guide Wires For Cto With Platinum Iridium Distal Spring Coil N• Wires Available In Variable Distal Tip Stiffness, Measured In Terms Of Grams 121 Special Tapering Ptca Guide Wires For Cto With Platinum Iridium Distal Spring Coil - N• Wires Available In Variable Distal Tip Stiffness, Measured In Terms Of Grams N 122 Special Tapering Ptca Guide Wires For Cto With Hydrocoat-Hydrophilic Coating - N• Wires Available In Variable Distal Tip Stiffness, Measured In Terms Of Grams N 123 Special Hydrophilic Ptca Guide Wires For Cto With Super Elastic Alloy ( Ni-Ti ) Core - N• Polyurethrane Hydrophilic Distal Coating N 124 Special Ptca Guide Wires For Cto, Dedicated For Retrograde Approach - 125 Extensiion ( Doc ) Wire For Approved Regular Length Ptca Guide Wires - 126 Penetration Catheters For Cto Having Rotational Blunt Penetration - 127 Penetration Devices For Cto By Blunt Dissection Using Acuating Jaws - 128 Advance Wound Absorbent, Haemostatic Composed Of 100% Natural Biopolymer Gamma Sterilised And Moisture Proof Packing Pack Size : 3.5X3.5 Cm 129 Advance Wound Absorbent, Haemostatic Composed Of 100% Natural Biopolymer Gamma Sterilised And Moisture Proof Packing Pack Size : 5X5 Cm 130 Arterial Puncture Closure Devices – Collagen Plug Based - 131 Arterial Puncture Closure Devices – Suture Based - 132 Disposable Femoral Compression Devices – Balloon Based Compression - 133 Compression Devices For Radial Artery – Balloon Based Compression – 134 Compression Devices For Radial Artery – Strap Based Compression - 135 Ptca Guide Wire Re-Entry Catheter For Cto 136 Specialized Ptca Guide Wire For Retrograde Approach & Cto – N.014 One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Sprig Coil Coil, Tip Load .8G , 180Cm Length Tip Radiopacity 3Cm N 137 Specialized Ptca Guide Wire For Retrograde Approach & Cto – N.014 One Piece Core Wire With Jointless Spring Coil 22Cm Polymer Sleeve Length With Slip Coat Coating Over The Polymer Sleve, Tip Load 1G Ans 0.8G , 180Cm Length Tip Radiopacity 3Cm N 138 Specialized Ptca Guide Wire For Cto –Stainless Steel Core Without Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 1.7 To 8.7 Gm. 139 Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 0.8 To 4.8 Gm. 140 Specialized Ptca Guide Wire For Cto –Stainless Steel Core With Intermediate Polymer Cover With Hydrophilic Coating Wire Tip Load Varying From 5.5 To 13.9 Gm 141 Specialized Ptca Guide Wire For Retrograde Approach & Cto – N.014 One Piece Core Wire With Jointless Spring Coil Ptfe Coating Over The Shaft , Tip Load 3G, 4.5G, 6Gand 12G , 180Cm Length With Tip Radiopacity 11Cm N 142 Specialized Ptca Guide Wire For Retrograde Approach & Cto – N.014 One Piece Core Wire With Jointless Spring Coil And Slip Coat On The Spring Coil , Ptfe Coating Over The Shaft , Tip Load 3G, , 180Cm Length With Tip Radiopacity 11Cm N 143 Specialized Ptca Guide Wire For Retrograde Approach & Cto – Nnon Hydrophilic Coated Tapered Tp .009 With A Tip Load Of 9Gm And Tip Radiopacity Of 20Cm N 144 Specialized Ptca Guidewire For Retrograde Approach & – Ndedicated Guidewire For Externalization With Tip Load Of 3G Length 330Cm N 145 Specialized Ptca Guide Wire For Retrograde Approach & Cto – N One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To .009 L, Tip Load 9G , 180Cm Length Tip Radiopacity 20Cm N 146 Specialized Ptca Guide Wire For Retrograde Approach & Cto – N One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To .009 L, Tip Load 12G , 180Cm Length Tip Radiopacity 20Cm N 147 Specialized Ptca Guide Wire For Retrograde Approach & Cto – N One Piece Core Wire With Jointless Spring Coil With Slip Coat Coating Over The Spring Coil Tapering To .008 L, Tip Load 20G , 180Cm Length Tip Radiopacity 17Cm N 148 Specialized Ptca Guide Wire For Retrograde Approach & Cto – N.014 One Piece Core Wire With Jointless Spring Coil, Ptfe Coating Over The Shaft , Tip Load .7G, 180Cm Length With Tip Radiopacity 4Cm N 149 Specialized Ptca Guide Wire For Retrograde Approach & Cto – N.014 One Piece Core Wire With Jointless Spring Coil Tapering To .009 16Cm Polymer Sleeve Length With Slip Coat Coating Over The Polymer Sleeve, 190Cm Length Tip Radiopacity 16Cm N 150 Specialized Ptca Guide Wire For Retrograde Approach & Cto – Nptca Guide Wire With Sion Tech Technology -Tapered Type, Polymer Sleeve, Tipload 1.0G N 151 Specialized Ptca Guide Wire For Retrograde Approach & Cto – Nptca Guide Wire With Sion Tech Technology-Tapered Type, Polymer Sleeve, Tip Load 0.6G Ptca Guide Wire N 152 Specialized Ptca Guide Wire For Retrograde Approach & Cto – N.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tip With A Tip Load Of 1.7Gm .190Cm Length Tip Radiopacity 15Cm, N 153 Specialized Ptca Guide Wire For Retrograde Approach & Cto – N.012 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tip With A Tip Load Of 3.5Gm190cm Length Tip Radiopacity 15Cm N 154 Specialized Ptca Guide Wire For Retrograde Approach & Cto – N.010 One Piece Core Wire With Joint Less Spring Coil With Sion Tech Technology Length 15Cm , Cone Tip With A Tip Load Of 4.5 Gm 190Cm Length Tip Radiopacity 15Cm N 155 Long Sheaths / Introducers - Prefaced Valved Long Sheaths For Rfa With Mullins Curve, N Multipurpose Curve, Other Curves, 7F To 9F, Atleast 80- Cm Long, 0.038 Wire Compatible N 156 Long Sheaths / Introducers - Nbidirectonal, Steerable Long Sheaths With Variable Reach, Autolock N 157 Long Sheaths / Introducers - Nbrite Tip Intervention Sheaths With Tip Visualization, Kink Resistant, N Cold Shapable With Silicon Coating N 158 Long Sheaths / Introducers - Nintroducer Sheaths For Electrophysiology, Nwith Various Swartz Curves Sl 0-4, Sr 0-4, 8F, 8.5F , 9F N 159 Long Sheaths / Introducers - Nlong Sheaths ( Peel Away, Slittable, With Breaking Valve ) For Special Applications Like Coronary Sinus Intubation, Lateral Vein, Special Curves Like Renal, Hook Shape Etc N 160 Long Sheaths / Introducers - Npeel Away Introducer Sheaths With Break Away Hwmostatic Valves For Pacing Leads, 5F-12F, 10 Cm – 30 Cm, Optional Infusion Side Port, Radio-Opaque Distal Tip And Multiple Curves N 161 Long Sheaths / Introducers - Nmultiport Catheter Introducer Sheaths With Catheter Locks N 162 Pacing Lead Stablizers- 163 Long Sheaths / Introducers - N3-D Braided Steerable Guiding Introducer Sheath, Supporting Transseptal Crossing, Atrial Ablation Procedures, With One Device Delivery System Having All 8 Steering Curves ( Sl And Sr ) Can Accommodate Multiple Sheath Sizes N 164 Surface Patch For 3 D Mapping – ( Adult & Pediatric ) 165 Balloon Catheter For Non-Contact 3 D Mapping 166 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Nconfigurations Would Be Pole, French. Curve Of Catheter, Electrode Configuration, Fixed / Deflectable N 167 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Nquadripolar, 6, Any, Any, Fixexd N 168 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Nquadripolar, 5-7, Mullins, 2-5-2-5, Fixed N 169 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Nquadripolar, 5-7, Josephson, 2-5-2-5, Fixed N 170 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Nquadripolar, 5-7, His Bundle, 2-5-2-5, Fixed N 171 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Nquadripolar, 5-7, Mullins, 4-2-4-2, Fixed N 172 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Nquadripolar, 6, Mullins, 2-5-2-5, Deflectable N 173 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ntripolar, 5-7, Any, Any, Fixed N 174 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ntripolar, 6, Any, 2-5-2-5, Fixed N 175 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Nhexapolar, 6 , Any, 2-5-2-5 Tip 2-5-2, 20-30 Cm, Proxbipole , For Unipolar Signals N 176 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ndecapolar, 5-7, Any, Any, Fixed N 177 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ndecapolar, 6, Any, 2-10-2, Fixed N 178 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ndecapolar, 5-7, Any, 2-5-2, Fixed N 179 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ndecapolar, 5-7, Any, 2-5-2, Fixed N 180 Diagnostic Ep Catheters - Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ndecapolar, 5-7, Any, 2-2-2-10-2-2-2-10-2, Deflectable N 181 Woven Ep Diagnostic Catheters – N ( Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability ) Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Nquadripolar, 5-7, Josephson, 2-5-2-5, Fixed N 182 Woven Ep Diagnostic Catheters – N ( Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability ) Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipu Nquadripolar, 5-7, Mullins, 4-2-4-2, Fixed N 183 Woven Ep Diagnostic Catheters – N ( Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability ) Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Nhexapolar, 6, Any, 2-5-2-5 Tip, 2-5-2, 20Cm, Prox, Fixed N 184 Woven Ep Diagnostic Catheters - N ( Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability ) Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ndecapolar, 6, Any, 2-10-2, Fixed N 185 Woven Ep Diagnostic Catheters- N ( Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability ) Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ndecapolar, 5-7, Any, 2-5-2, Fixed N 186 Woven Ep Diagnostic Catheters- N ( Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability ) Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ndecapolar, 5-7, Any, 2-2-2, Fixed N 187 Woven Ep Diagnostic Catheters- N ( Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability ) Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ndecapolar, 5-7, Any, 2-2-2-10-2-2- 2-10-2, Deflectable N 188 Cables For Ep & Rfa – Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Nquadripolar Cable, Compatible With Quardripolar Catheter N 189 Cables For Ep & Rfa – Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ndecapolar Cable, Compatible With Decapolar Catheter N 190 Cables For Ep & Rfa – Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Nhexapolar Cable, Compatible With Hexapolar Catheter N 191 Cables For Ep & Rfa – Nthe Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design ( Electrode Size, Electrode Distance, Electrode Material ) Etc. It Will Be Easier If The Common Catheters Use Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes / Platinum, Palladium Electrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Nall Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Ntripolar Cable, Compatible With Tripolar Catheter N 192 Deflect. Decaduapolar ( 20 Poles ) For A Flutter All Diameters 193 Deflectable Decapolar ( 10 ) ( Pulm. Vein ) --- All Diameters- 194 Defectable Decaduapolar ( 20 ) ( Pulm. Vein ) All Diameters- 195 2F Multipolar ( > Ten Electrodes ) For Mapping Through Coronary Vasculature 196 Basket Catheter With Accessory- 197 Crista Catheter With Accessory- 198 Pacing Catheter With Angiogrophic Capability- N• Variable Sizes N• Bipolar Or Quadripolar With Appropriate Cable N• Cvp Monitoring & Angiographic Facility N 199 Pentapolar Diagnostic Catheter – Fixed Curve Ncatheter Material – Woven Nelectrode – Stainless Steel, Platinum, Palladium Nquality Approval – - N Description :-Pentapolar Diagnostic Catheter Curved Type, Catheters Made Of Woven Material With Braided Conducting Wire, Catheters Should Have Bio Flexibility And To Maintain The Stability Over Long Period Of Time. Sterile, Packed Individually And Labeled Accordingly. Nsize ( Fr ) , 6Fr, Electrode Spacing ( Mm ) , 5, 5, 5, 282Mm, 5, 5, 5, 152Mm, Curve, Josephson N 200 Octapolar Diagnostic Catheter – Fixed Curve Ncatheter Material – Woven Nelectrode – Stainless Steel, Platinum, Palladium Nquality Approval – - Ndescription Noctapolar Diagnostic Catheter Curved Type, Catheters Made Of Woven Material With Braided Conducting Wire, Catheters Should Have Bio Flexibility And To Maintain The Stability Over Long Period Of Time. Sterile, Packed Individually And Labeled Accordingly. Nsize ( Fr ) , 6 Fr , Electrode Spacing ( Mm ) 5 Mm, 1 Mm, 1, 10, 1 Mm Curve Cournand, N 201 16 Pole Diagnostic Catheter – Fixed Curve Ncatheter Material – Woven Nelectrode – Stainless Steel, Platinum, Palladium Nquality Approval – - Ndescription N16 Pole Diagnostic Catheter Curved Type, Catheters Made Of Woven Material With Braided Conducting Wire, Catheters Should Have Bio Flexibility And To Maintain The Stability Over Long Period Of Time. Sterile, Packed Individually And Labeled Accordingly. Nsize ( Fr ) N 6 Fr Nelectrode Spacing ( Mm ) N1-5-1 Mm, 1-5-1 Mm , Curve, Damato, Small 60 N 202 20 Pole Diagnostic Catheter – Fixed Curve Ncatheter Material – Woven Nelectrode – Stainless Steel, Platinum, Palladium Nquality Approval – Ndescription N20 Pole Diagnostic Catheter Curved Type, Catheters Made Of Woven Material With Braided Conducting Wire, Catheters Should Have Bio Flexibility And To Maintain The Stability Over Long Period Of Time. Sterile, Packed Individually And Labeled Accordingly. N6 Fr Size ( Fr ) Electrode Spacing ( Mm ) N5, 5, 5, 5, 5, 5, 5, 5 5, 5, 5, 5, 5, 5, 5, 5, 5 5, 5, 5 Mm Curve K N 203 24 Pole Diagnostic Catheter – Fixed Curve Ncatheter Material – Woven Nelectrode – Stainless Steel, Platinum, Palladium Nquality Approval – - Ndescription N24 Pole Diagnostic Catheter Curved Type, Catheters Made Of Woven Material With Braided Conducting Wire, Catheters Should Have Bio Flexibility And To Maintain The Stability Over Long Period Of Time. Sterile, Packed Individually And Labeled Accordingly. Size ( Fr ) , 6 Fr , Electrode Spacing ( Mm ) , 2-4-2 Mm, 2-7-2 Mm, 2-9-2 Mm , Curve K N 204 Bi-Directional Steerable Catheters Nhandle- Thumb Wheel Or Push Pull Nautomatic Curve Lock Mechanism Nelectrode – Stainless Steel, Platinum, Palladium Nquality Approval – - Ndescription Size ( Fr ) Electrode Spacing ( Mm ) Ncurve, Small, Large 4.0 N 205 Atrial Mapping Catheters Nelectrode – Stainless Steel, Platinum, Palladium Nquality Approval – - Ndescription N10-20 Pole Atrial Mapping Bidirectional Curve Actuation With Curve Lock Mechanism. Wire Braided Nsize ( Fr ) 7 Fr Electrode Spacing ( Mm ) All, Curve, All N 206 Dual Curve Rf Ablation Catheter Nbi-Directional Steerable Nelectrode – Stainless Steel, Platinum, Palladium Nquality Approval – - Ndescription Size ( Fr ) 7.8 Fr Nelectrode Spacing ( Mm ) 2-5-2 Mm Ncurve, Medium, , Large, , Extra Large N N 207 Ablation Catheters ( Items 1-10 ) - N ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladium Or Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. Nall Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Ntype Nablation Catheter Regular Tip Size 4 Mm Ndiameter 6-8F Curves / Reach All ( Equivalent To Na-F, J, K, 270 ) Comments N 208 Ablation Catheters ( Items 1-10 ) - N ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladium Or Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. Nall Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Ntype Ablation Catheter Regular Tip Size 8 Mm Ndiameter 6-8F Curves / Reach All ( Large, Extended Reach ) Ncomments Dual Sensor N N 209 Ablation Catheters ( Items 1-10 ) - N ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladium Or Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. Nall Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Ntype Nablation Catheter Regular Tip Size 3.5 Mm Ndiameter Any Curves / Reach All Comments N 210 Ablation Catheters ( Items 1-10 ) - N ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladium Or Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. Nall Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Ntype Nablation Catheter Regular Tip Size 2 Mm Ndiameter Any Curves / Reach All Comments N 211 Ablation Catheters ( Items 1-10 ) - N ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladium Or Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. Nall Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Ntype Ablation Catheter Regular Tip Size N4 Mm Diameter 5F Curves / Reach All Ncomments Pediatric Use N N 212 Ablation Catheters ( Items 1-10 ) - N ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladium Or Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. Nall Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Ntype Nablation Catheter Irrigated Tip ( Open ) Ntip Size Any Diameter 7-9F Curves / Reach Nall Curves / Reach Comments N 213 Ablation Catheters ( Items 11-20 ) - N ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladium Or Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. Nall Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Ntype Ablation Catheter Regular Ntip Size 4 Mm Diameter 6-8F Curves / Reach Nall ( Equivalent To A-F, J, K, 270 ) Comments N 214 Ablation Catheters ( Items 11-20 ) - N ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladium Or Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. Nall Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Ntype Nablation Catheter Regular Tip Size 3.5 Mm Diameter Nany Curves / Reach All Comments N 215 Ablation Catheters ( Items 11-20 ) - N ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladium Or Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. Nall Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Ntype Nablation Catheter Regular Ntip Size 2 Mm Diameter Any Curves / Reach Nall Comments N 216 Ablation Catheters ( Items 11-20 ) - N ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladium Or Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. Nall Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Ntype Ablation Catheter Regular Ntip Size 4 Mm Diameter 5F Curves / Reach All Comments Npediatric Use 217 Ablation Catheters ( Items 11-20 ) – N ( All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G. ) ( All Itemss Differing In Make / Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladium Or Stainless Steel Etc ) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters / Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. Nall Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Ntype Ablation Catheter Bidirectional Ntip Size, Any Diameter Any Curves / Reach All Comments N 218 Ncatheters, Cables, Accessories For Endocardial Solutions ( Esi ) Accessories N 219 Reusable Defibrillation / Transcutaneous Pacing Patches ( Suitable For Equipment In . ) 220 Disposable Defibrillation / Transcutaneous Pacing Patches ( Suitable For Equipment In . ) – 221 Defibrillation / Transcutaneous Pacing Patches For Use In Infants And Children – 222 Cryo Catheters ( And Accessories ) For Ablation Of Arrhythmias In Children And Adults – 223 Disposable Electrocautery Patches For Rfa ( Suitable For Stockert And Ept 1000 Ablators ) – 224 Reusable Electrocautery Patches For Rfa ( Suitable For Stockert And Ept 1000 Ablators ) – 225 Reusable Defibrillation / Transcutaneous Pacing Patches ( Suitable For Equipment In . ) – 226 Disposable Defibrillation / Transcutaneous Pacing Patches ( Suitable For Equipment In ) 227 Defibrillation / Transcutaneous Pacing Patches For Use In Infants And Children – 228 Cryo Catheters ( And Accessories ) For Ablation Of Arrhythmias In Children And Adults 229 Disposable Electrocautery Patches For Rfa ( Suitable For Stockert And Ept 1000 Ablators ) 230 Reusable Electrocautery Patches For Rfa ( Suitable For Stockert And Ept 1000 Ablators ) 231 Regular Radiofrequency Ablation Catheter, 6 / 7 Fr. Size With 4 Mm Tip Electrode And Multiple Curves With Connector. – 232 Radiofrequency Ablation Catheter Deflectable Curved, 7 Fr Size With 8 Mm Tip Electode With Connector. – 233 Radiofrequency Ablation Catheter Bi-Directional Deflectable Curve, 7 Fr Size With 8Mm Tip Electrode With Connector. – 234 Regular Irrigated Tip Ablation Catheter 7 Fr Size With 3.5Mm Tip Electrode, 6 Side-Holes For Open Loop Irrigation At The Tip Electrode Connector 235 Irrigated Tip Ablation Catheter With Bidirectional Deflectable Curve, 7 Fr Size With 3.5 Mm Tip Electrode, 6 Side-Holes For Open Loop Irrigation At The Tip Electrode With Connector. – 236 Irrigated Tip Ablation Catheter With Half The Flow Rate Of Regular Irrigated Cath Deflectable Curve, 7Fr Size With 3.5Mm Tip Electrode With Connector 237 Irrigated Navigation System Catheters For Mapping And Ablation Compatible With Magnetic Based 3D Electroanatomical System ( 7.5 F ) With Connector 238 Variable Loop Pulmonary Vein Catheter With Connector. – 239 Fixed Loop Pulmonary Vein Catheter With Connector. – 240 External Disposable Non-Sterile Gel Electrode Compatible To Magnetic Based 3D Mapping System. 241 Tubing For Irrigated Catheters Compatible With Pump Available In Sms H. 242 Fixed Curve Quadripolar Electrophysiology Catheter ( All Curve, 5-7F ) With Connector. – 243 Deflectable Quadripolar Electrophysiology Catheter ( All Curve, With Connector ) . – 244 Fixed Curve Decapolar Catheter For Coronary Sinus Mapping ( All Curve, 5-7 F ) With Connector 245 Deflectable Decapolar Catheter For Coronary Sinus Mapping ( All Curve, 5-7F ) With Connector 246 Duo Decapolar Electrophysiology Catheter – 20 Poles With Connector– 247 Connecting Cables For 3D Mapping System. – 248 Basket Catheter With Accessories Compatible With Ibi Compatible 249 Crista Catheter With Accessories Compatible With Abalator 250 2F Multipolar Catheter ( >10 Poles ) For Mapping Through Coronary Vasculature With Ibi Compatible Connector– 251 Pacing Catheter With Angiographic Capabilities With Cables / Connectors. – 252 Temperature Ablation Catheter With Fiber Weave, Kevlar Wrap And Stainless Steel Center Support For Better Curve Formation, Durability And Tension Knob For Micro Movements– 253 Tip Deflecting Coronary Sinus Catheter 254 Navistar Compatible Regular Catheter With Ibi Compatible Connector– 255 Navistar Compatible Thermocol Catheter With Ibi Compatible Connector– 256 Location / Reference Patch For Navistar Compatible Catheters – 257 Velocity Nav X Surface Electrode Kit 258 Ensite Compatible Array Catheter 259 Disposable Defibrillator / Transcutaneous Pacing Patches– 260 Cryocatheters For Ablation With Accessories 261 Preshaped, Valved Long Sheeths For Mapping And Rf Ablation Of All Curves ( 7F- 9F ) > 80Cm Long 262 Introducer Sheaths For Electrophysiology Of Various Curves ( 8F, 8.5 F, 9F ) 263 Steerable Introduction Sheaths For Mapping And Rf Ablation ( 7F – 9F ) ( Quote All Lengths, Curves And Any Other Special Feature ) 264 Bidirectional Steerable Long Sheaths With Variable Reach And Autolock For Eps 265 Temporary Pacing Leads - 266 Temporary Pacing Leads: Balloon Floatable – 267 Radio Frequency Ablation Catheter For Vericose Vein 268 Intracardiac Ultrasound / Echo Catheter For Guiding Rfa Compatible With The Existing Echo Machine At Sms Hospital, Jaipur ( Quote All Prices Of The Catheters And Accessories 269 Trans Septal Puncture Needle For Bmv For Adults Use 270 Permanent Venacava Filter 271 Temporary Venacava Filter 272 Mullins Sheaths – Kink Resistant 6 / 7 F 273 Good Quality Disposable Sterile Patient Drape For Ptca, Impervious To Fluids, With One Absorbent Sheet With Hole And Long Size, Two Plastic Sheet ( Long Size ) One Sterile Cloth Towel 274 Sterilized Packed, Non Vinyl, Lead-Free And Light Weight Absorabel Shield For Protection From Scattered Radiation During Interventional Procedures Like Left Subclavian Ep / Device, Cto, Angioplasty And Ir Etc. 275 Sterilized Packed, Non Vinyl, Lead-Free, Light Weight Absorabel Shield Forsafety From Scattered Radiation, Should Be Specific For Peripheral Procedures Like Aaa. 276 Non Vinyl, Lead-Free X-Ray Attenuation, Light Weight Surgical Cap For Radiation Safety In All Fluoro Labs And Must Be Fit All Head Sizes. 277 Intracardiac Ultrasound / Echo Catheter For Guiding Rfa Compatible With The Existing Echo Machine At Rnt Mc Udaipur ( Quote All Prices Of The Catheters And Accessories ) 278 Distal Protection Device 0.014 Wire Umbrella Type Coronary Filter 279 Distal Protection Device 0.014 Wire Umbrella Type Carotid Artery Filter 280 Iabp Catheter With Accessories - N• Should Be Compatible With Existing Machine ( Data Scope ) In ., Smsh N 281 Thrombectomy Catheters With Manual Suction During Ptca 282 Thrombectomy Catheters With Distal Balloon Occlusion And Automated Suction During Ptca 283 Thrombectomy Catheters With Motorized Cutting And Suction During Ptca - 284 Embolic Protection Devices Based On Filter Technology / Mechanism - 285 Embolic Protection Devices With Distal Balloon Occlusive Technology 286 Embolic Protection Devices With Proximal Balloon Occlusive Technology - 287 Distal Embolic Protection Device - N• Should Be On A .014” Wire N• Should Be Made Of Polyurethane With Radio-Opaque Nitinol Loop N• Should Be Suspended On The .014” Wire With A Suspension Arm N• Should Not Occlude Flow While In Placement N• Should Be Rapid Exchange Type N• Should Be Compatible With A 6 F Guiding Catheter ( 0.066” Id ) N• Should Allow Optimal Filtration In Vessels 3.5 – 5.5 Mm Size N 288 High Pressure Angioplasty Balloon For Peripheral Vascular Use N• Should Have Rated Burst Pressure = 14 Atmosphere N• Should Have Hydrophilic Coating N• Should Be Available In Various Outer Diameters And Balloon Lengths And Various Shaft Lengths N 289 Ivc Filter – N• For Optimal Filtration Of Ivc Diameter Of Up To 40 Mm N• Made Of Either Nitinol Or Stainless Steel N• Catheter Carrier System Inner Diameter Should Be Of Maximum 12 F N• It Should Be Possible To Insert From Either Jugular Or Femoral Access N• Should Be For Permanent Use N 290 Ivc Filter – N• For Optimal Filtration Of Ivc Diameter Of Up To 28 Mm N• Made Of Nitinol And Filter Length To Be Up To 38 Mm N• Catheter Carrier System Inner Diameter Should Be Of Maximum 7 F Size N• It Should Be For Permanent Use N• It Should Be Possible To Place The Filter From Femoral / Jugular / Antecubital Access N 291 Ivc Filter – N• For Optimal Filtration Of Ivc Diameter Of Up To 28 Mm N• Made Of Nitinol And Filter Length To Be Up To 55 Mm N• Catheter Carrier System Inner Diameter Should Be Of Maximum 10 F Size N• It Should Be For Optional ( Permanent Or Retrievable ) Use N• It Should Be Possible To Place The Filter From Femoral / Jugular / Antecubital Access N 292 Renal Denervation Device For Rf Ablation Of Renal 293 Valvoplasty Balloon Catheters With Negative Pressure Device - N• Varying Sizes And Diameters N• Approved For Pediatric / Adults Use N 294 Special Pediatric Valvoplasty Balloon Catheters Compatible With 4 French Sheath - N• Compatible With 0.025 Inch Guide Wire N• Varying Length And Diameter N 295 Valvoplasty Balloon Catheters ( Sizes 10 – 22 Mm ) N• Approved For Pediatric / Adults Use N• Varying Length And Diameter N• Nominal Pressure < 4 Atm N 296 Balloon Catheters ( Sizes 10 – 22 Mm ) - N• Approved For Pediatric / Adults Use N• Varying Length And Diameter N• Nominal Pressure < 8 Atm N 297 Atrial Septostomy Catheter - N• 4Fr. / 5Fr. / 6 Fr. Sizes N 298 Detachable Balloon 299 Vascular Plugs 300 Valvoplasty Balloon Catheters ( All Sizes ) N• Approved For Pediatric / Adults Use N• Varying Length And Diameter N• Nominal Pressure < 4 Atm N 301 Special Type B Valvoplasty Balloon Catheter For Tavi Instalation Purpose 302 Special Valvoplasty Balloon Catheter N• Diameter Size 4Mm To 35Mm N• Length 20Mm To 60Mm N• Should Have Dog Boning For Precise Position N 303 Tavi ( Trans Catheter Aortic Valve Replacement System With All Required Accessories ) - 304 Park Blade Septectomy Catheter 305 Gelfoam Sheet For Vascular Embollization - 306 Liquid Embolization System Available In Various Sizes ( 2Ml, 3Ml & 6Ml ) 307 Pbmv Balloon ( All Types And Sizes ) With Accessories 308 Pbmv Balloon ( All Types And Sizes ) Without Accessories 309 Accessories Only For The Above Pbmv Balloons 310 Pbmv Balloon With Side Safety / Microholes With Accessories 311 Pbmv Balloon With Side Safety / Microholes Without Accessories 312 Ptmc Balloon With Hole In Balloon 313 Ptmc Balloon ( With Hole In Balloon ) With All Acessories 314 Mechanical Aspiration Device ( All Types ) 315 Ffr Wire With Accessories Compitable To St. Jude Imaging Machine - Radi Analyzer At Rntmc - N• Should Be 0.014 Inch Guide Wire N• Should Have High Fidelity Sensor Technology For Measurement Of Interavascular Pressure N• Should Have A Radio Opaque N• Should Have Operating Pressure Range Of -30 To + 300 Mmhg N• Should Have A Frequency Range Of 2.4000 – 2.4835 Ghz N• If Ffr Wire Is Not Compatible With Imaging Machine At Rntmc; Company / Distributor Should Provide Ffr Imaging Machine. N 316 Snare For Cardiovascular Purpose 317 Snare For Periferal Use 318 Catheter For Virtual Histology - ·     Should Be Compatible With Available Machine ( Boston Scientific ) At Rntmc. 319 Rotawire – N• Should Be Compatible To Rota Machine In Rnt Medical College, Udaipur 320 Athero-Cath Devices For Directional Coronary Atherectomy ( Dca ) 321 Motor For Dca - 322 Rotalink Burr - ( Compatible With Existing Rota Machine - Boston Scientific At Rntmc ) . 323 Rotalink Advancer - ( Compatible With Existing Rota Machine - Boston Scientific At Rntmc ) . 324 Rotalink Plus ( Advancer And Burr ) - ( Compatible With Existing Rota Machine - Boston Scientificat Rntmc ) . 325 Rotational Atherectomy Guide Wires - 326 Rotaglide Lubricant - 327 Above Knee And Bellow Knee Directional Athrectomy Device 328 Asd Closure Devices With Delivery System N• Approved For Pediatric / Adult Use N• Device Made Of Biologically Inert Material N• Self-Centering, Detachable Device With Delivery Cable N• Available In All The Sizes ( 6 Mm – 40 Mm ) N 329 Asd Closure Devices Without Delivery System 330 Delivery Sheath For Asd Closure Device – N• Compatible With The Device Mentioned Above 331 Preloaded Asd Closure Devices – N• Approved For Pediatric / Adult Use N• Device Made Of Biologically Inert Material N• Preloaded Device With Delivery Cable N 332 Asd Closure Device With Delivery System :- Coated Wth Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh Sewn With Ptfe Membrane Available In All Sizes 333 Fenestrated Sheath And Closure Device 334 Pfo Closure Device 335 Left Atrial Appendage Closure Device 336 Pfo Closure Devices With Delivery System N• Approved For Pediatric / Adult Use N• Device Made Of Biologically Inert Material N• Available In All The Sizes N 337 Pfo Closure Devices Without Delivery System – 338 Delivery Sheath For Pfo Closure Device – N• Compatible With The Devi In Item No. 60 & 63 N 339 Pfo Closure Devices With Delivery System N• Device Made Of Biologically Inert Material N• Available In All The Sizes N 340 Sizing Balloon For Device Closure – Circular Shape 341 Sizing Balloon For Device Closure – Oval Shaped 342 Sizing Plate For Device Closure - 343 Delivery Cable For Asd / Vsd / Pda Devices - 344 Retrievers For Asd / Vsd / Pda Devices - 345 Sheath For Retrival Of Devices - 346 Amplatzer Plug 347 Left Atrial Apendage Closure Device 348 Vsd Closure Devices With Delivery System N• Approved For Pediatric / Adult Use N• Device Made Of Biologically Inert Material N• Self-Centering, Detachable Device With Delivery Cable N• Available In All The Sizes ( 6 Mm – 40 Mm ) N 349 Vsd Closure Devices Without Delivery System – 350 Delivery Sheath For Vsd Closure Device – N• Compatible With The Device In Item Above 351 Vsd Closure Device With Delivery System :- Elongatable Waist Soft Woven Mesh Low Delivery Profile As Low As 4F And Maximum Upo To 7 F Double Sided Screw For Retrograde Or Antegrade Approach Available In All Sizes 352 Muscular Vsd Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane Symmetric, Asymmetric And Eccentric Forms Available In All Sizes 353 Pda Closure Devices With Delivery System N• Approved For Pediatric / Adult Use N• Device Made Of Biologically Inert Material N• Self-Centering, Detachable Device With Delivery Cable N• Available In All The Sizes N 354 Pda Closure Devices Without Delivery System N 355 Delivery Sheath For Pda Closure Device – N• Compatible With The Device Mentioned Above N 356 Pda Closure Device With Delivery System :- Coated With Titanium Nitride ( Tin ) Soft Woven Nitinol Mesh; Sewn With Ptfe Membrane Available In All Sizes 357 Pda Coils Made Of Steel / Nitinol / Platinum - N• 0.035, 0.038 Inches N• Sizes Ranging From 2 X 2 To 15 X 15 N 358 0.052 Inch Pda Coils Made Of Steel / Nitinol / Platinum N• Sizes Ranging From 2 X 2 To 15 X 15 N 359 Embolisation Coils ( 0.018 Inch ) - N• Sizes Ranging From 2 X 2 To 15 X 15 N 360 Embolisation Coils ( 0.035 Inch ) - N• Sizes Ranging From 2 X 2 To 15 X 15 N 361 Embolisation Coils ( 0.052 Inch ) - N• Sizes Ranging From 2 X 2 To 15 X 15 N 362 Embolisation Coils - N• Should Be 0.014 / 0.018” Compatible N• Should Be Made Of Platinum With Synthetic Fibres N• Should Be Non Tapering / Straight N• Should Be Mr Compatible N• Should Be Available In Any Or The Following Diameters: 2-10 Mm N• Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated N 363 Embolisation Coils - N• Should Be 0.035 / 0.038” Compatible N• Should Be Made Of Platinum With Synthetic Fibres N• Should Be Mr Compatible N• Should Be Tapering From A Larger To A Smaller End N• Should Be Available In Following Sizes: Diameters: 5-10 Mm And Length 2-15 Cm N• The Diameter To Tapered End For Tapering Type Coil Should Be Mentioned N 364 Embolisation Coils - N• Should Be 0.035 / 0.038 / 0.052” Compatible N• Should Be Non Tapering / Straight N• Should Be Made Of Stainless Steel With Synthetic Fibres N• Should Be Available In The Following Sizes: Diameters: 3-15 Mm And Length 2-15 Cm N 365 Coil Pusher Wire For 0.014 / 0.018” Coils, Compatible With The Quoted Microcatheters - 366 Ivus Catheter - N• Should Be Compatible With Available Machine - Boston Scientific I Lab. N 367 Ivus Catheter With Accessories Compatible To Boston Imaging Machine At Rntmc- 368 Ptca Catheter With Deflectable Distal End - N• Should Guide The Direction Of Ptca Guide Wire N 369 Micro Catheter To Be Used For Cto Antegrade And Retrograde Apporch. 370 Guide Extention Catheter ( Guidezilla Type ) - N• 120 Proximal Hypotube Shaft N• 0.57 Inner Diameter & 0.066” Outer Diameter N• Should Be With Proximal Marker And 1 X 1 Braiding N 371 Double Leumen Micro Catheter ( Crusade Type ) – 372 Micro Catheter To Be Used For Cto Antegrade And Retrogate Apporch Caravel Type With Entry Profile 1.4 French - 373 Coronary Microcatheter With Entry Profile Of 1.4 Fr. And Crossing Profiel Of 1.8 Fr . Available Length 135 Cm And 150 Cm 374 Micro Catheter To Be Used For Cto Antegrade And Retrogate Apporch With Proximal Outer Diameter 2.6 French And Distal Outer Diameter 1.8 French - 375 Dedicated Micro Catheter For Side Branch Access 376 Dedicated Micro Catheter For Side Branch Access 377 Special Micro-Catheter For Cto Retrograde Approach 378 Thrombectomy Catheters With Manual Suction During Ptca 379 Coronary Microcatheter 380 Aspiration Device 381 Hemostatic Y Adapter With Push Pull Button 382 Hemostatic Y Adapter With Push Pull Button 383 Temporary Pacing Leads With One More Lumen Having Stylet With Coaxial Wire For Controlling Stifness Biopolar Without Balloon Floting 384 Coronary Stent With Custom-Length Stent Delivery System With Independtly Operable Expansion Elements 385 Coronary Tapered Stent N• Should Be Compatible With Available Machine N 386 Stainless Steel Coronary Stents, Premounted On Balloon N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) N• Available In The Sizes And Lengths N 387 Cobalt Chromium Coronary Stents, Premounted On Balloon – N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) N• Available In The Sizes And Lengths N 388 Covered Coronary Stents – N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Both N• Available In The Sizes And Lengths N• Covered Graft Stent For Dissected Artery N 389 Dedicated Bare Metal Coronary Stents For Bifurcation Lesions – N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) N• Available In The Sizes And Lengths N 390 Stainless Steel Coated Stents ( All Types ) 391 Cobalt Chromium Coated Stents ( All Types ) 392 Carbon Coated Stents With 2 Platinum Markers On Stent Also - 393 Stainless Steel Renal Stents, Premounted On Balloon – N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) N• Available In The Sizes And Lengths N 394 Cobalt Chromium Renal Stents, Premounted On Balloon – N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) N• Available In The Sizes And Lengths N 395 Balloon Mounted Sirolimus Eluting Stent With Biodurable Polymer On Stainless Steel Platform Us 396 Balloon Mounted Sirolimus Eluting Stent With Biodurable Polymer On A Non Stainless Steel Platform 397 Balloon Mounted Sirolimus Eluting Stent With Biodurable Polymer On Stainless Steel Platform 398 Balloon Mounted Sirolimus Eluting Stent With Biodurable Polymer On Non Stainless Steel Platform With Uniform Ultrathin Struts ( Upto 50 Microns ) 399 Balloon Mounted Sirolimus Eluting Stent With Biodurable Polymer On Stainless Steel Platform 400 Balloon Mounted Sirolimus Eluting Stent With Biodurable Polymer On Non Stainless Steel Platform 401 Balloon Mounted Sirolimus Eluting Stent With Biodurable Polymer On Non Stainless Steel Platform With Uniform Ultrathin Struts ( Upto 50 Microns ) 402 Balloon Mounted Sirolimus Eluting Stent With Biodurable Polymer On Non Stainless Steel Platform With Uniform Thin Struts ( 51-80 Microns ) 403 Balloon Mounted Sirolimus Eluting Stent With Biodurable Polymer On Non Stainless Steel Platform With Uniform Thin Struts >80 Microns ) 404 Balloon Mounted Sirolimus Eluting Stent On Non Stainless Steel Platform With Uniform Thin Struts ( < 50 Microns ) For Coronary Artery Diameters Of All Sizes Including 2.0 Mm Or Less 405 Balloon Mounted Sirolimus Eluting Stent On Non Stainless Steel Platform With Uniform Thin Struts ( 51-80 Microns ) For Coronary Artery Diameters Of All Sizes Including 2.0 Mm Or Less 406 Balloon Mounted Sirolimus Eluting Stent On Non Stainless Steel Platform With Uniform Struts Thickness ( >80 Microns ) Coronary Artery Diameters Of All Sizes Including 2.0 Mm Or Less 407 Balloon Mounted Sirolimus Eluting Stent On Non Stainless Steel Platform With Uniform Ultrathin Struts ( Upto 50 Microns ) For Coronary Artery Diameters Of All Sizes Including 4.5 Mm Or More 408 Balloon Mounted Sirolimus Eluting Stent On Non Stainless Steel Platform With Uniform Thin Struts ( 51-80 Microns ) For Coronary Artery Diameters Of All Sizes Including 4.5 Mm Or More 409 Balloon Mounted Sirolimus Eluting Stent On Non Stainless Steel Platform With Uniform Struts Thickness ( > 80 Microns ) For Coronary Artery Diameters Of All Sizes Including 4.5 Mm Or More 410 Balloon Mounted Sirolimus Eluting Stent On Non Stainless Steel Platform With Uniform Ultrathin Struts ( Upto 50 Microns ) For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 8 Mm Or Less 411 Balloon Mounted Sirolimus Eluting Stent On Non Stainless Steel Platform With Uniform Ultrathin Struts ( 51-80 Microns ) For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 8 Mm Or Less 412 Balloon Mounted Sirolimus Eluting Stent On Non Stainless Steel Platform With Uniform Strut Thicknerss ( Of >80 Microns ) For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 8 Mm Or Less 413 Balloon Mounted Sirolimus Eluting Stent On Non Stainless Steel Platform With Uniform Ultrathin Struts ( Upto 50 Microns ) For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 8 To 48 Mm 414 Balloon Mounted Sirolimus Eluting Stent On Non Stainless Steel Platform With Uniform Ultrathin Struts ( Upto 51-80 Microns ) For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 8 To 48 Mm 415 Balloon Mounted Sirolimus Eluting Stent On Non Stainless Steel Platform With Uniform Ultrathin Struts ( >80 Microns ) For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 8 To 48 Mm 416 Balloon Mounted , Polymer Free, Sirolimus Eluting Stent On Non Stainless Steel Platform With Strut Thickness ( Upto 50 Micron ) 417 Balloon Mounted , Polymer Free, Sirolimus Eluting Stent On Non Stainless Steel Platform With Strut Thickness ( 51-80 Micron ) 418 Balloon Mounted , Polymer Free, Sirolimus Eluting Stent On Non Stainless Steel Platform With Strut Thickness ( >80 Micron ) 419 Balloon Mounted Sirolimus Eluting Stent On Stainless Steel Platform With Microporous Surface Biodegradable Polymer And Shellac Resin Top Coat Having Diameter From 2 To 4 Mm And Length From 8 To 40 Mm 420 Balloon Mounted Cobalt Chromium, Dual Drug Polymer Free Stent With Microporous Surface And Abluminal Coating With Shellac Resin Top Coat. Probucol Drug Instead Of Polymer , Available In Diameter 2 To 4 Mm And Length 8 To 48 Mm 421 Balloon Mounted, Cobalt Chromium, Abuminally Coated Sirolimus Eluting Stent With Microporous Surface And Biodegradable Polymer And Shellac Resin Top Coat Having Long Lenghts Of 8Mm To 48 Mm And Diameter 2 To 4 Mm 422 Stainlees Steel Balloon Mounted, Abuminally Coated Sirolimus Eluting Stent With Microporous Surface And Biodegradable Polymer And Shellac Resign Top Coat Having Long Lenghts Of 8Mm To 48 Mm And Diameter 2 To 4 Mm With Temperature Controlled Packing And Temperature Monitoring Device 423 Sirolimus Eluting Stent Having Cobalt Chromium Platform With Biodegradable Polymer; Abluminal And Specialized Gradient Coating With Strut Thickness Upto 50 Microns 424 Sirolimus Eluting Stent Having Cobalt Chromium Platform With Biodegradable Polymer; Abluminal And Specialized Gradient Coating With Strut Thickness 51 -80 Microns 425 Sirolimus Eluting Stent Having Cobalt Chromium Platform With Biodegradable Polymer; Abluminal And Specialized Gradient Coating With Strut Thickness >80 Microns 426 Sirolimus Eluting Stent Having Cobalt Chromium Platform With Biodegradable Polymer; Abluminal And Specialized Gradient Coating Low Entry Profile Baloon 0.018 And Core Wire Technology In Shaft Upto 50 Microns 427 Sirolimus Eluting Stent Having Cobalt Chromium Platform With Biodegradable Polymer; Abluminal And Specialized Gradient Coating Low Entry Profile Baloon 0.018 And Core Wire Technology In Shaft 51-80 Microns 428 Sirolimus Eluting Stent Having Cobalt Chromium Platform With Biodegradable Polymer; Abluminal And Specialized Gradient Coating Low Entry Profile Baloon 0.018 And Core Wire Technology In Shaft >80 Microns 429 Balloon Mounted Everolimus Eluting Stent With Biodurable Polymer On Stainless Steel Platform. All Sizes From 2.25 To 4 Mm And Length From 8 To 48 Mm , Mid Marker Balloon Placement At Both Ends 430 Balloon Mounted Everolimus Eluting Stent With Biodurable Polymer On Non-Stainless Steel Platform. All Sizes From 2.25 To 4 Mm And Length From 8 To 48 Mm , Mid Marker Balloon Placement At Both Ends 431 Ballooon Mounted , Everolimus Eluting Stent With Biodegradable Polymer On Stainless Steel Platform. All Sizes From 2.25 To 4 Mm And Length From 8 To 48 Mm 432 Balloon Mounted, Everolimus Eluting Stent With Biodegradable Polymer On Non-Stainless Steel Platform With Uniform Ultrathin Struts ( Upto 50 Microns ) 433 Balloon Mounted, Everolimus Eluting Stent With Biodegradable Polymer On Non-Stainless Steel Platform With Uniform Ultrathin Struts ( Upto 51-80 Microns ) 434 Balloon Mounted, Everolimus Eluting Stent With Biodergradable Polymer On Non-Stainless-Steel Platform With Strut Thickness ( >80 Microns ) 435 Balloon Mounted, Everolimus Eluting Stent On Non-Stainless-Steel Platform With Ultrathin Struts ( Upto 50 Microns ) For Coronary Artery Diameters All Sizes Including 2.0 Mm Or Less. Us 436 Balloon Mounted , Everolimus Eluting Stent On Non-Stainless-Steel 437 Balloon Mounted, Everolimus Eluting Stent On Non-Stainless-Steel Platform With Uniform Ultrathin Struts ( Upto 50 Microns ) For Coronary Artery Diameters Of All Sizes Including 4.5 Mm Or More 438 Balloon Mounted, Everolimus Eluting Stent On Non-Stainless-Steel Platform With Uniform Thin Struts ( Upto 51- 80 Microns ) For Coronary Artery Diameters All Sizes Including 4.5 Mm Or More 439 Balloon Mounted, Everolimus Eluting Stent On Non-Stainless-Steel Platform With Uniform Struts Thickness ( > 80 Microns ) For Coronary Artery Diameters Including 4.5 Mm Or More 440 Balloon Mounted, Everolimus Eluting Stent On Non-Stainless-Steel Platform With Uniform Ultrathin Struts ( Upto 50 Microns ) For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 8Mm Or Less 441 Balloon Mounted, Everolimus Eluting Stent On Non-Stainless-Steel Platform With Uniform Thin Struts ( Upto 51- 80 Microns ) For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 8Mm Or Less 442 Balloon Mounted, Everolimus Eluting Stent On Non-Stainless-Steel Platform With Uniform Struts Thickness ( > 80 Microns ) For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 8Mm Or Less 443 Balloon Mounted, Everolimus Eluting Stent On Non-Stainless-Steel Platform With Uniform Ultrathin Struts ( Upto 50 Microns ) For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 48Mm Or More 444 Balloon Mounted, Everolimus Eluting Stent On Non-Stainless-Steel Platform With Uniform Thin Struts ( Upto 51- 80 Microns ) For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 48Mm Or More 445 Balloon Mounted, Everolimus Eluting Stent On Non-Stainless-Steel Platform With Uniform Struts Thickness ( > 80 Microns ) For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 48Mm Or More 446 Balloon Mounted, Zotarolimus Eluting Stent With Biodurable Polymer* On Non-Stainless-Steel Platform 447 Balloon Mounted, Zotarolimus Eluting Stent On Non-Stainless-Steel Platform For Coronary Artery Stent On Non-Stainless- Steel Platform For Coronary Artery Diameters Of All Sizes Including 2.0 Mm Or Less 448 Balloon Mounted, Zotarolimus Eluting Stent On Non-Stainless-Steel Platform For Coronary Artery Stent On Non-Stainless- Steel Platform For Coronary Artery Diameters Of All Sizes Including 4.5 Mm Or Less 449 Balloon Mounted, Zotarolimus Eluting Stent On Non-Stainless-Steel Platform For Coronary Artery Stent On Non-Stainless- Steel Platform For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 8Mm Or Less 450 Balloon Mounted, Zotarolimus Eluting Stent On Non-Stainless-Steel Platform For Coronary Artery Stent On Non-Stainless- Steel Platform For Coronary Artery Disease Segment Of All Lengths Including Stent Length Of 48Mm Or More. 451 *Biodurable Polymers Including Sibs ( Poly Styrene-B-Isobutylene B-Styrene ) , Pbma ( Poly N Buty Methacrylate, Peva ( Polyethene Coviny Acetate ) , Pvdf-Hfp ( Poly Vinlidene Fluoride Hexafluoroprolene, Pc ( Phosphorylcholine ) Siloxane Copolymer And Any Other Commercially Approved Biodurable Polymer 452 Balloon Mounted Paclitaxel Eluting Stent With Biodurable Polymer On Stainless Steel Platform 453 Balloon Mounted Paclitaxel Eluting Stent With Biodurable Polymer On Non-Stainless Steel Platform. 454 Balloon Mounted Paclitaxel Eluting Stent With Biodurable Polymer On Stainless-Steel Platform. 455 Balloon Mounted Paclitaxel Eluting Stent With Biodurable Polymer On Non-Stainless-Steel Platform. 456 Balloon Mounted Paclitaxel Eluting Stent With Biodurable Polymer On Non-Stainless-Steel Platform For Coronary Artery Disease Segment Length Of All Lengths Upto 48Mm Or Less. 457 Balloon Mounted Paclitaxel Eluting Stent With Biodurable Polymer On Non-Stainless-Steel Platform For Coronary Artery Disease Segment Length Of All Lengths Upto 48Mm Or More. 458 Medicated Coronary Stent – Newer Limus Analogue ( Other Than Sirolimus, Everolimus, Zotarolimus ) 459 Balloon Mounted , Newer Limus Analogue With Biodurable Polymer* On Stainless Steel Platform. 460 Balloon Mounted , Newer Limus Analogue With Biodurable Polymer* On Non-Stainless Steel Platform. 461 Balloon Mounted , Newer Limus Analogue With Biodurable Polymer On Stainless Steel Platform. 462 Balloon Mounted , Newer Limus Analogue With Biodurable Polymer On Non-Stainless Steel Platform. 463 Balloon Mounted , Newer Limus Analogue Eluting Stent On Non-Stainless Steel Platform For Coronary Artery Diameters Of All Size Including 2.0Mm Or Less 464 Balloon Mounted , Newer Limus Analogue Eluting Stent On Non-Stainless Steel Platform For Coronary Artery Diameters Of All Size Including 4.5Mm Or More. 465 Balloon Mounted , Newer Limus Analogue Eluting Stent On Non-Stainless Steel Platform For Coronary Artery Diameters Of All Size Including 8 Mm Or Less. 466 Balloon Mounted , Newer Limus Analogue Eluting Stent On Non-Stainless Steel Platform For Coronary Artery Diameters Of All Size Including 48 Mm Or Molre. 467 Balloon Mounted Drug Eluting Coronary Stent Dedicated For Bifurcation Lesion. 468 Balloon Mounted Drug Eluting Coronary Stent Dedicated For Bifurcation Side Branch Access. 469 Self Expanding Drug Eluting Coronary Stent Dedicated For Bifurcation Lesion. 470 Self Expanding Drug Eluting Coronary Stent For Dedicated Side Branch Access. 471 Balloon Mounted Drug Eluting, Tapered Coronary Stents. 472 Balloon Mounted Covered Coronary Stents 473 Balloon Mounted Covered Coronary Stents Compatible With 5F Guide Catheter. 474 Balloon Mounted Coronary Stents Covered With Flexible Mesh Sleeve 475 Balloon Mounted Drug Eluting Stents Approved Specifically For Use In Chronic Total Occlusions 476 Balloon Mounted Drug Eluting Stents Approved Specifically For Use In Direct Stenting 477 Balloon Mounted Drug Eluting Stents Approved Specifically For Use With Short Duration ( Three Month ) Dapt ( Dual Antiplatelet Therapy ) 478 Balloon Mounted Drug Eluting Stents Approved Specifically For Use With Short Duration ( One Month ) Dapt ( Dual Antiplatelet Therapy ) 479 Balloon Mounted, Dual Drug Coated Drug Eluting Stents 480 Nitinol Carotid Stent, 0.014” Guide Wire, 5-10 Mm Dia – Straight 481 Nitinol Carotid Stent, 0.014” Guide Wire, 5-10 Mm Dia – Tapered- 482 Nitinol Monorail Closed Cell Design With Flared Ends- Tapered , 6F Sheath Compatible 483 Stainless Steel , Monorail, Self-Expandable Carotid Stent 484 Monorail 0.014” Compatible Stainless Steel Renal Stent Dia 4-7 Mm Length 485 Monorail 0.014” Compatible Cobalt Chromium Renal Stent Dia 4-7 Mm Length 10-24Mm 486 Monorail 0.014” Compatible Cobalt Chromium Renal 5-7 Mm, Length 12-18 , Mm 5 F Compatible 487 Monorail 0.018” Wire Compatible Balloon Mounted Renal Stents Diameter 4-7 Mm Length 14-19Mm 488 Balloon Mounted, Over The Wire, Renal Stent 489 Peripheral Stainless Steel Sten5-10 Mm Dis Length 20-60 Mm 490 Stainless Steel Stents Dia 5-10 Mm Dia Length , Liegth 17-57 Mm 491 Peripheral Stainless Steel Sten11-14 Mm Dis Length 20-60 Mm. 492 Peripheral Stainless Steel 493 Balloon Expendable Cocr Stent With High Radial Force With Semi Flexible Hybrid Cell Design Length From 13 Up To 57 Mm And Diameter From 6 To 32 Mm 494 Peripheral Cobalt Chromium Stent 5-10 Mm Dia Length 15-60 Mm 495 Non Balloon Mounted Cobalt Chromium 496 Otw 0.035 Wire Nitinol Peripheral Stent 5-10 Dia 497 Otw 0.035 Wire Nitinol Peripheral Stent 11-14 Dia 498 Otw 0.035 Wire Nitinol Peripheral Stent Dia 5-14 Mm Length 20-120 Mm 499 Otw 0.035 Wire Nitinol Peripheral Stent Dia 15-24 Dia 500 0.018 Wire Compatible Nitinol Peripheral Stent 501 Vascular Mimetic Stent For Distal Sfa, Popliteal And Across Joints, 018, Nitinol, 4-7 Mm Diameter Various Lengths Upoto 200 Mm 502 Monorail Based Nitional Peripheral Self Expanding Stent, All Sizes 503 Otw 0.035 Wire, Braided Elgiloy Self Expandable Stent, Dia 5-24 Mm Variable Lengths 504 Drug Eluting Peripheral Stent 505 Aortic Stent Graft Self Expandable Tubular Dia 23-36 Mm With Delivery System - The Manufacturer Should Agree To Supply The Size Customized To The Patients Anatomy Based On 506 Aortic Stent Graft Self Expandable Bifuuurcated Dia 23-36 Mm With Delivery System And Contralateral Limb - . The Manufacturer Should Agree To Supply The Size Customized To The Patients Anatomy Based On 507 Extension Tube Graft For Aortic Stent Graft 508 Illiac Extension For Aortic Stent Graft 509 Balloon Expandable Peripheral Stent Graft 510 Ptfe Covered Balloon Expendable Co Cr Stent With High Radial Strength , Stent Length 18 To 57 Mm Diameters Up To 35 Mm 511 Balloon Expandable Pulmonary Artery Stents N• Approved For Pediatric / Adult Use N• Available In Various Sizes N 512 Self Expandable Pulmonary Artery Stents – N• Approved For Pediatric / Adult Use N• Available In Various Sizes N 513 Ivc Stents Self Expendable - N• Approved For Pediatric / Adult Use N• Available In Various Sizes N 514 Ivc Stents Balloon Mounted - N• Approved For Pediatric / Adult Use N• Available In Various Sizes N 515 Stents With Epc Capturing Technology - 516 Biodegradable Coronary Stents - 517 Tapered Coronary Stent ( De ) 518 Tapered Carotid Stent – 519 Drug Eluting Stent For Below The Knee Peripheral Artery N• Should Be Otw / Rapid Exchange N• Available In All Sizes And Diameter N 520 Peripheral Stent Balloon Expandable ( Otw / Rx ) – N• Should Be 0.035” Compatible N• Should Be Made Of Cobalt Chromium N• Should Be Quoted Either In Open Cell Or Closed Cell Design N• Should Be Available In Various Balloon Ods N• Should Have Balloon / Stent Lengths Available N• Should Have A Shaft Lengths Of 75-135 Cm N 521 Peripheral Stent Balloon Expandable – ( Otw / Rx ) – N• Should Be 0.035” Compatible N• Should Be Made Of Stainless Steel N• Should Have A Tandem Architecture Design N• Should Have All Balloon Ods From 5-10 Mm In 1 Mm Increments N• Should Have Available Various Balloon / Stent Lengths Of 20 To 55 Mm N• Should Have A Shaft Lengths Of 75-135 Cm N 522 Peripheral Stent Balloon Expandable – ( Otw / Rx ) N• Should Be 0.035” Compatible N• Should Be Made Of Stainless Steel N• Should Be Laser Cut Slotted Tube With Closed Cell Design N• Should Have Balloon Ods From 5-25 Mm, Bare Or Balloon Mounted N• Should Have Available Various Balloon / Stent Lengths From 2-6 Cm N• Should Have A Shaft Lengths Of Up To 135 Cm N 523 Peripheral Stent Balloon Expandable – ( Otw / Rx ) N• Should Be 0.014 / 0.018” Compatible N• Should Over The Wire N• Should Be Made Of Cobalt Chromium / Bare N• Should Have Balloon Od Available In 4-7 Mm N• Should Have Balloon / Stent Lengths Of 12-18 Mm N• Should Have Shaft Lengths Of 80-150 Cm N 524 Peripheral Self Expandable Interwoven Nitinol Stent For Popliteal Artery – N• Should Be 0.014 / 0.018” Compatible N• Should Over The Wire / Rapid Exchange N• Should Be Available In All Sizes N 525 Self-Expanding Peripheral Stent – N• Should Be 0.014 / 0.018” Compatible N• Should Over The Wire N• Should Be Made Of Nitinol N• Should Have The Least Lesion Crossing Profile For All Stent Diameters N• Should Be Available In Various Stent Diameters Of 6-10 Mm N• Should Be Available In Various Stent Lengths > 60 Mm N• Should Have A Shaft Lengths Of At Least 110 Cm N 526 Self-Expanding Peripheral Stent – N• Should Be 0.014 / 0.018” Compatible N• Should Over The Wire N• Should Be Laser Cut Open Cell Nitinol Tube N• Should Have A Low Lesion Crossing Profile N• Should Be Available In All Stent Diameters Of 6-10 Mm N• Should Be Available In Stent Lengths Of 20-60 Mm N• Should Be On A Shaft Lengths Of 110-140 Cm N 527 Self-Expanding Peripheral Stent – N• Should Be 0.014 / 0.018” Compatible N• Should Be Of Rapid Exchange Type N• Should Be Made Of Nitinol N• Should Be Available In Stent Lengths Of 3-4 Cm N• Should Have A Minimum Shaft Lengths Of 110 Cm N 528 Self-Expanding Peripheral Stent – N• Should Be 0.035” Compatible N• Should Over The Wire N• Should Be Made Of Nitinol N• Should Be Available In Various Outer Diameters N• Should Be Of Various Stent Lengths N• Should Be On A Shaft Lengths Of 80-140 Cm N 529 Self-Expanding Peripheral Stent – N• Should Be 0.035” Compatible N• Should Be Of Rapid Exchange Type N• Should Be Made Of Nitinol N• Should Be Available In Various Outer Diameters N• Should Be Of Various Stent Lengths N• Should Be On A Shaft Lengths Of 80-140 Cm N 530 Self-Expanding Peripheral Stent – N• Should Be 0.035” Compatible N• Should Over The Wire N• Should Be Laser Cut From Single Nitinol Tube With No Welds N• Should Be Available In Outer Diameters Of 5-14 Mm N• Should Be Available In Stent Lengths Of 2-15 Cm ( Various Sizes ) N• Should Be On A Shaft Lengths Of 80-140 Cm N 531 Self-Expanding Peripheral Stent Of Large Diameter – N• Should Be 0.035” Compatible N• Should Be Made Of Nitinol Or Stainless Steel N• Should Be Available In Outer Diameter Of 14-26 Mm N• Should Be Available From 2-12 Cm In Stent Length N• Should Be On A Minimum Shaft Length Of 110 Cm N• Should Be Compatible With A 6-12 F Sheath N 532 Peripheral Drug Eluting Stent – N• Should Have Any One Of The Following Drugs ( Sirulimus, Evorolimus, Zotarolimus, Paclitaxel ) Impregnated On The Stent N• Should Be Balloon Mounted Or Self-Expanding Type N• Should Be Available In Outer Diameters Of 4-10 Mm N• Should Be Available In Various Lengths Of 20-100 Mm N 533 Peripheral Bio-Degradable Or Absorbable Metal Stent – N• Should Be Balloon Mounted Or Self-Expanding Type N• Should Be Available In Outer Diameters Of 4-10 Mm N• Should Be Available In Various Lengths Of 20-100 Mm N 534 Self-Expanding Peripheral Covered Stent – N• Should Be 0.035” Compatible N• Should Over The Wire N• Should Be Made Of Nitinol With Fabric Coating N• Should Be Available In Various Outer Diameters N• Should Be Of Various Stent Lengths N• Should Be On A Shaft Lengths Of 80-140 Cm N 535 Carotid Self Expendable Stents – N• Should Be 0.014” Compatible N• Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) N• Should Be Available In Various Diameters And Length N• Should Be On A Shaft Length Of 80-140 Or Above Length N 536 Carotid Self Expendable Stents – N• Should Be 0.018” Compatible N• Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) N• Should Be Available In Various Diameters And Length N• Should Be On A Shaft Length Of 80-140 Or Above Length N 537 Carotid Self Expendable Stents N• Should Be 0.035” Compatible N• Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) N• Should Be Available In Various Diameters And Length N• Should Be On A Shaft Length Of 80-140 Or Above Length N 538 Carotid Stents Balloon Expendable – N• Should Be 0.014” Compatible N• Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) N• Should Be Available In Various Diameters And Length N• Should Be On A Shaft Length Of 80-140 Or Above Length N 539 Carotid Stents Balloon Expendable – N• Should Be 0.018” Compatible N• Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) N• Should Be Available In Various Diameters And Length N• Should Be On A Shaft Length Of 80-140 Or Above Length N 540 Carotid Stents Balloon Expendable – N• Should Be 0.035” Compatible N• Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) N• Should Be Available In Various Diameters And Length N• Should Be On A Shaft Length Of 80-140 Or Above Length N 541 Carotid Stents Balloon Expendable Stent With Tapered Diameter – N• Should Be 0.035” Compatible N• Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) N• Should Be Available In Various Diameters And Length N• Should Be On A Shaft Length Of 80-140 Or Above Length N 542 Carotid Self Expendable Stents With Tapered Diameter – N• Should Be 0.014” Compatible N• Should Be Over The Wire And Rapid Exchange ( Otw / Rx ) N• Should Be Available In Various Diameters And Length N• Should Be On A Shaft Length Of 80-140 Or Above Length N 543 Endovascular Stent Graft Device For Treatment Of Thoracic Aortic Aneurysms And Dissections - N• Device Should Be With Proximal Barbs, With Or Without Distal Bare Spring Configuration, And Should Be Either Tapered Or Non – Tapered N• The Aortic Device Should Be Available In Any One Or More Of The Following Sizes: Od 26-44Mm; Length 4-24 Cm. The Device Should Be Able To Be Advanced On Upto 24 F Shaft Size. N• The Manufacturer Should Agree To Supply The Size Customized To The Patient’S Anatomy Based On Ct Angiography N 544 Endovascular Stent Graft Device For Treatment Of Abdominal Aortic Aneurysms - N• Device Should Be With Proximal Barbs, With Or Without Distal Bare Spring Configuration, And Should Be Either Tapered Or Non – Tapered N• Devices With Transrenal Or Suprarenal Fixation Should Be Quoted. N• The Aortic Device Should Be Available In Any One Or More Of The Following Sizes: Od 12-44Mm; Length 4-24 Cm. The Device Should Be Able To Be Advanced On Aupto 24 F Shaft Size. N• The Limb Extensions Of The Main Device For Abdominal Aortic Applications Should Be Available In 12-22 Mm Diameter, With Or Without Flared Ends And Upto 12 Cm In Length N• The Manufacturer Should Agree To Supply The Size Customized To The Patient’S Anatomy Based On Ct Angiography N 545 C.P. Stent Covered 546 C.P. Stent Uncovered 547 C.P. Stent Covered Balloon Mounted 548 C.P. Stent Uncovered Balloon Mounted 549 Abdominal Stent Graft For Treating Aortic Aneurysm 550 Thorosic Stent Graft For Treating Thorosic Aneurysm And Thorosic Dissection 551 Covered Aortic Stent Balloon Mounted 552 Non-Covered Aortic Stent Balloon Mounted - 553 M.F.M. Device For Aaa Graft Stent 554 Aaa Graft Stent For Aortic Dissection Branched Andograft 555 Aaa Graft Stent For Aortic Dissection Chimney Andograft 556 Ptca Balloon ( Semi Compliant ) With Entry Profile =0.016, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 1.5Mm To 4.00 Mm And Lengths 8Mm To 20 Mm 557 Ptca Balloon ( Non Compliant ) With Entry Profile =0.016, Hydrophilic Coating And Tapered Tip, Available In Diameter Ranging From 2Mm To 4.5 Mm And Lengths 5Mm To 20 Mm 558 Intra Vascular Lithotripsy Balloon ( Shock Wave ) Ivc Catheter And Connecting Assembly, Intergrated 12 Mm Sc Balloon , 2 Emitters ( 80 Pulses Per Catheter ) , Diameter From 2.5 To 4.0 Mm 559 Ptca Balloon ( Semi-Compliant ) - N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons N• Available In All Sizes And Lengths N 560 Ptca Balloon ( Non-Compliant ) - N• Quote Both Monorail ( Rapid Exchange ) And Otw Balloons N• Available In All Sizes From 2 - 4.0 Mm, Variable Lengths N• Should Have A Very High Rated Burst Pressure N 561 Special Large Ptca Balloons Of More Than 4 Mm - N• Variable Lengths N• Quote Both Monorail ( Rapid Exchange ) And Otw Balloons N 562 Special Ptca Balloon Catheter With Low Crossing Profile - N• Must Have Crossing Balloon Profile Of Less Than 0.025 Inches N• Quote Both Monorail ( Rapid Exchange ) And Otw Balloons N 563 Special Ptca Balloon Catheter Of Sizes 0.9 To 1.5 Mm - N• Should Be Available In Variable Balloon Lengths N• Quote Both Monorail ( Rapid Exchange ) And Otw Balloons N 564 Special Ptca Balloon - Ultra High Pressure Plaque Modification Device, Dual Layer / Rbp - 35 Bar And 45 Bar / Low Crossing Profile - Size :- 1.5 To 4.5 Mm Dual Markers 565 Special Ptca Balloon Catheter 0.85 Mm Non Compliant Super High Pressure Balloon Dilatation Catheter Pressure From 23 Bar To 28 Bar Rbp Variable Large Mono Rail System, Hydrophilic Coated. 566 Special Otw Ptca Balloon For Septal Ablation For Hocm - N• Quote Both Monorail ( Rapid Exchange ) And Otw Balloons N 567 Special Extra Length Ptca Balloon Catheters - N• Quote Both Monorail ( Rapid Exchange ) And Otw Balloons N 568 Zerofold Ptca Balloon - N• Available In All Sizes And Length N• Quote Both Monorail ( Rapid Exchange ) And Otw Balloons N 569 Coronary Ptca Cutting Balloon With Flextomes - N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons N• Available In The Sizes And Lengths N 570 Rapid Exchange Low Pressure Atraumatic Microspores Ptfe Balloon Catheter For Local Infusion Of Drug, Catheter Length > 130 Cm. Size 1.5 – 4.0 Mm 571 Bevelled Ballon Of Various Sizes For Entry Through The Stent Into Side Branch 572 Special Ptca Balloon For Cto – N• Diameter Should Be 0.75 Mm Or Less N 573 Drug Eluting Ptca Balloon - N• All Types & Sizes N• Different Types Of Drugs N 574 Ptca Balloon For Retrograde Approach Of Cto - N• Should Be Available In Both Regular And Long Lengths For Retrograde Approach N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons N 575 Cutting Balloon For Ptca Having Microsurgical Atherotomes ( Blades ) -000 N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons N• Available In The Sizes And Lengths N 576 Scoring Balloon Catheter For Ptca - N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons N• Available In The Sizes And Lengths N 577 Dual Wire Ptca Balloon Dilatation Catheter - N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons N• Available In The Sizes And Lengths N 578 Ptca Bifurcation Balloon - N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons N• Available In The Sizes And Lengths N 579 Cto Balloon - N• Ultra Low Entry Profile Balloon With 0.016 Entry Profile Thin Marker Of 25 Micron And Core Wire Shaft With Diameter Ranging From 1 Mm To 4 Mm 580 Cutting Balloon For Renal And Peripheral Arteries - N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons N• Available In The Sizes And Lengths N 581 Balloon Dilatation Catheter For Aorta & Ivc- N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons N• Available In The Sizes And Lengths N 582 Bib ( Balloon In Balloon ) Type Balloons For Coarctation Dilatation - N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) Balloons N• Available In The Sizes And Lengths N 583 Z Med Type Balloon For Aortic Coactation N• 5 To 20 Cm Diameter In All Sizes N• Otw / Rapid Exchange, Compatible With 0.014” / 0.035” And 0.038” Wire N 584 Z Med Type Balloon For Aortic Coactation N• More Than 20 Cm Diameter In All Sizes N• Otw / Rapid Exchange, Compatible With 0.014” / 0.035” And 0.038” Wire N 585 Otw Balloon For Periferal Angioplasty All Size And Diameters- Approved 586 Dual Coated Stent , Premounted On Balloon – N• Monorail ( Rapid Exchange ) And Over-The-Wire ( Otw ) N• Available In The Sizes And Lengths N 587 Durg Eluting Pta Balloon For Below The Knee Peripheral Artery 588 High Pressure Angioplasty Balloon For Peripheral Vascular Use – N• Should Have Rated Burst Pressure = 14 Atmosphere N• Should Have Hydrophilic Coating N• Should Be Available In Various Outer Diameters And Balloon Lengths And Various Shaft Lengths N 589 High Pressure Angioplasty Balloon For Peripheral Vascular Use – N• Should Have Rated Burst Pressure = 14 Atmosphere N• Should Have Hydrophilic Coating N• Should Be Available In 4-10 Mm ( In 1 Mm Increments ) And 12 Mm Diameters And 2-10 Cm Balloon Lengths N• Should Have A Shaft Size Of 75-135 Cm N 590 Peripheral Balloon Catheter – N• Should Be 0.035” Compatible N• Should Be Over The Wire N• Should Have A Burst Pressure Of At Least 10 Atmosphere ( At Least 6 Atmosphere For Larger Balloons ) N• Should Have Hydrophilic Coating N• Should Be Available In Various Sizes Of Od And Balloon Lengths N• Should Be Available In Various Shaft Lengths N 591 Peripheral Balloon Catheter – N• Should Be 0.035” Compatible N• Should Over The Wire N• Should Be Non-Compliant Or Semi-Compliant N• Should Have Hydrophilic Coating N• Should Be Available In Od Of 3-10 Mm And 12 Mm And Balloon Length Of 2-10 Cm N• Should Have A Burst Pressure Of At Least 10 Atmosphere ( The 12 Mm Od Balloon Should Have A Burst Pressure Of At Least 6 Atmosphere ) N• Should Pass Through A Maximum 6F Sheath ( The 12 Mm Od Balloon Should Pass Through A Maximum 7F Sheath ) N• Should Have A Shaft Lengths 80-135 Cm N 592 Peripheral Balloon Catheter – N• Should Be 0.014 / 0.018” Compatible N• Should Over The Wire N• Should Have Hydrophilic Coating N• Should Be Available In Various Balloon Diameters N• Should Be Available In Various Lengths Of The Balloon N• Should Be Available In Various Shaft Lengths 80-150 Cm 593 Peripheral Balloon Catheter – N• Should Be 0.014 / 0.018” Compatible N• Should Over The Wire N• Should Be Controlled / Semi-Compliant Type N• Should Have Hydrophilic Coating N• Should Be Available In Ods Of 2-7 Mm N• Should Be Available In All Balloon Lengths Of 2-4 Cm N• Should Be Available In Shaft Lengths Of 80-150 Cm N 594 Peripheral Balloon Catheter – N• Should Be 0.014 / 0.018” Compatible N• Should Be Rapid Exchange Type N• Should Have Hydrophilic Coating N• Should Be Available In Various Outer Balloon Diameters N• Should Be Available In All Balloon Lengths N• Should Be Available In Shaft Lengths N 595 Peripheral Cutting Balloon Catheter – N• Should Be Available In Balloon Od Of 3-6 Mm N• Should Have Upto 15 Mm Or Upto 20 Mm Working Length N• Catheter Shaft Length Should Be Upto 140 Cm N 596 Nspecial Catheters For Af, Flutter Etc ( Items 1-9 ) N ( Quote All Diameters, French Size, Different Electrodes Like Platinum, Palladium Or Stainless Steel ) Nall Items Should Be Compatible With Existing Ep / Tracer Machine At Rnt Medical College, Udaipur N

Key Value

Document Fees
INR 400 /-
EMD
INR 800000.0 /-
Tender Value
INR 4 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail