Construction Of Primary Processing Centre On Tomato For Golaghat Tomato Farmer Producer Company Ltd At Vill Rupkolia Po Barpatharua Furkatinh Golaghat 02 Dist Golaghat Group No 3, Rupkolia Golaghat-Assam

Assam Industrial Infrastructure Development Copr-AIIDC has published Construction Of Primary Processing Centre On Tomato For Golaghat Tomato Farmer Producer Company Ltd At Vill Rupkolia Po Barpatharua Furkatinh Golaghat 02 Dist Golaghat Group No 3. Submission Date for this Tender is 07-03-2020. Building Work Tenders in Rupkolia Golaghat Assam. Bidders can get complete Tender details and download the document.




Tender Notice

23734003
Construction Of Primary Processing Centre On Tomato For Golaghat Tomato Farmer Producer Company Ltd At Vill Rupkolia Po Barpatharua Furkatinh Golaghat 02 Dist Golaghat Group No 3
Open Tender
Indian
Assam
Rupkolia Golaghat
07-03-2020

Tender Details

Construction Of Primary Processing Centre On Tomato For Golaghat Tomato Farmer Producer Company Ltd At Vill Rupkolia Po Barpatharua Furkatinh Golaghat 02 Dist Golaghat Group No 3

Key Value

Document Fees
INR 850 /-
EMD
INR 82567.0 /-
Tender Value
INR 41.28 Lakhs /-

BOQ Items

Name of Work: Construction of Primary Processing Centre on Tomato for Golaghat Tomato Farmer Producer Company Ltd. at Vill- Rupkolia, P.O. Barpatharua, Furkatinh, Golaghat-02, Dist.- Golaghat, Group No.3
Sl. No. 48893 Item Code / Make Quantity Units
1 1 CIVIL WORKS: Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc., providing shoring & shuttering where necessary and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.- Upto a depth of 2.0 m below the existing ground level -- in ordinary soil. item1 130 Cu.m.
2 2 Earth/ sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. -- with river sand or silt (predominantly non plastic) by truck carriage including loading at quarry /source, transport by truck, unloading at site, spreading, watering to obtain optimum moisture content, compacting to obtain 90% Proctor's density, complete as directed and as specfied. item2 160 Cu.m.
3 3 Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling. item3 375 Cu.m.
4 4 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In proportion 1 cement : 3 sand : 6 coarse aggregate 40 mm down by volume. item4 13 Cu.m.
5 5 Providing and laying 25mm thick damp proof course with cement concrete in proportion 1:1.5:3 with graded stone aggregate of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. item5 19 Sq.m
6 6 Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (A) In substructure up to plinth level: Foundation, footing, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick.Grade of concrete M15 (1:2:4 ) item6 32 Cu.m.
7 7 Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B) In super structure from plinth level up to 1st floor level: Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, chajja, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing. item7 50 Cu.m.
8 8 Providing formwork with timber planking so as to give a rough finish, including centreing, shuttering, strutting & propping, and removal of formwork after completion of work: Foundations, footings, bases of columns, sides of plinth /tie beams and mass concrete works etc. -- with 38 mm planks item8 19 Sq.m
9 9 Providing formwork with 12 mm thick plywood board so as to give a rough finish, including centreing, shuttering, strutting & propping, and removal of formwork after completion of work -- work from plinth to 1st floor level: Columns, pillars, posts & struts at all levels -- square, rectangular, polygonal in plan or any shape like Tee/ L etc. having plane vertical face item9 120 Sq.m
10 10 Providing formwork with 12 mm thick plywood board so as to give a rough finish, including centreing, shuttering, strutting & propping, and removal of formwork after completion of work -- work from plinth to 1st floor level: Sides & soffits of beams, beam haunchings, cantilever girders, bressumers, lintels & horizontal ties -- depth of beam not exceeding 1.0 m. item10 155 Sq.m
11 11 Providing formwork with 12 mm thick plywood board so as to give a rough finish, including centreing, shuttering, strutting & propping, and removal of formwork after completion of work -- work from plinth to 1st floor level: Flat surfaces such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas, balconies, staircases and the like -- slabs up to 200mm in thickness. item11 15 Sq.m
12 12 Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete, work at all levels -- TMT bars Grade Fe415 of approved brand. item12 100 Qtl
13 13 Steel work welded in built up sections, framed work including cutting, hoisting and fixing in positions and applying priming coat of red-lead paint including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. item13 90 Qtl
14 14 Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) - TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement- 0.50 mm thick item14 340 Sq.m
15 15 Providing Pre Painted Galvalume Sheet (PPGL) accessories (Ridges / Valley / Gutter / Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete.- TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement- 0.50 mm thick item15 25 Sq.m
16 16 Providing plain Polycarbonate transparent sheet roofing at all levels with self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) 1.00 mm thick item16 35 Sq.m
17 17 Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level in cement mortar proportion 1 cement : 5 coarse sand in superstructure upto plinth level. item17 23 Cu.m
18 18 112 /115 mm (half brick) thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding rebars in columns, if any, to be embeded in cement mortar and will be measured and paid separately) - in cement mortar in proportion 1 cement : 5 coarse sand. item18 285 Sq.m
19 19 Providing and laying 65mm thick C.C. floor with metallic concrete hardener topping under layer of 50 mm thick cement concrete 1:2:4 (1cement:2 coarse sand:4 coarse aggregate of 20 mm and down) and top layer of 15mm thick of metallic cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 stone aggregate 6 mm and down) by volume with which metallic hardening compound of approved quality is mixed in the ratio of 4:1 (4 parts of cement: 1 part of metallic floor hardening compound of approved quality by weight) including finishing with curing complete as directed. item19 300 Sq.m
20 20 15mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and /or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed -- in cement mortar 1:4. item20 275 Sq.m.
21 21 20mm thick cement plaster in two coats, backing coat 15mm and finishing coat 5mm thk on rough side of single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and /or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed -- in cement mortar 1 cement : 4 coarse sand. item21 220 Sq.m.
22 22 Providing, fitting and fixing steel door (openable) of standard rolled steel sections as per relevant I.S. Code, joints mitred and welded with 15mm x 13mm x 100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device, handles, pegs, stays of 300mm long etc. complete including providing 2nos. of 12mmx12mm sq. bars (horizontal) duly welded to steel frame and applying a priming coat of red oxide paint etc. complete as per drawing. item22 3.5 Sq.m.
23 23 Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire lenth and jointed together at the ends by end-locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation complete including cost of wire, spring and hood cover for the shutters. item23 15 Sq.m.
24 24 Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.- Two track sliding,(2/3) Shutter item24 25 Sq.m
25 25 Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. item25 425 Kg
26 26 Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (i) Thickness = 1.5 mm thick item26 275 Sq.m.
27 27 Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. item27 275 Sq.m.
28 28 Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials. item28 220 Sq.m.
29 29 Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300 mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.- With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water, i.e. 1% solution. item29 295 Sq.m.
30 30 Installation of Hand Tube Well, Construction of MS Stagging 3.00 m height with RCC foundation, one no. 1000 litre capacity PCVC tank including placing over the stagging, 1 HP Motor Pump set, necessary pipe line, etc. complete as required and as per drawing and specification and as directed. item30 1 Job
31 31 ELECTRICAL WORKS: CIRCUIT WIRING: Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.- With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. item31 160 RM
32 32 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.- With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. item32 80 RM
33 33 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.- With 2 x 10 sq. mm. + earth continuity with 1x6 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. item33 25 RM
34 34 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.- With 4 x 6 sq. mm. + earth continuity with 2x4 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. item34 90 Metre.
35 35 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.- With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. item35 30 Metre.
36 36 Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan. item36 1 Each
37 37 Wiring to 5 Aa pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.- Medium point up to 6.00 metre. Length. item37 1 Each
38 38 Wiring to 5 Aa pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.- Long point up to 10.00 metre. Length. item38 2 Each
39 39 Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)- Long point up to 10.00 metre. Length. item39 8 Each
40 40 Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete- Short point up to 3.00 metre. length. item40 8 Each
41 41 Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete- Medium point up to 6.00 metre. Length. item41 13 Each
42 42 Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete- Long point up to 10.00 metre. Length. item42 7 Each
43 43 MODULAR SWITCH: Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.: 1-2 module type Metal item43 3 Each
44 44 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.: 3 module type Metal item44 3 Each
45 45 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.: 4-5 module type Metal item45 8 Each
46 46 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.: 6-8 module type Metal item46 1 Each
47 47 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.: 10 module type Metal item47 1 Each
48 48 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.:- 12-16 module type Metal item48 1 Each
49 49 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.- 2 module item49 3 Each
50 50 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.- 3 module item50 3 Each
51 51 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.- 4 module item51 8 Each
52 52 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.- 6 module item52 1 Each
53 53 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.- 10 module item53 1 Each
54 54 Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.- 16 module item54 1 Each
55 55 Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE complete as per direction of department. item55 6 Each
56 56 Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. item56 8 Each
57 57 Supplying including installation of socket outlet 6 Amps 3 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. item57 4 Each
58 58 Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. item58 8 Each
59 59 Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. item59 32 Each
60 60 SWITCH GEAR & PROTECTION: Supplying fitting and fixing industrial Plug & Socket in surface mounting TPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of 4P MCB complete with making necessary connection etc. as specified and directed by the Deptt.- ABB, Schneider MG, legrand, Hager make)- 30/32A Capacity. item60 4 Each
61 61 MCB IN-COMER TPN (HORIZONTAL DB): Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. - ABB, Schneider MG, legrand, Hager make)- 12 way SPN double door item61 1 Each
62 62 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. - ABB, Schneider MG, legrand, Hager make)- 8 way TPN (4+24) double door item62 1 Each
63 63 MCB, MCCB, RCCB, RCBO: Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.- C Series- (Schneider MG, legrand, Hager make)- 6 to 32A item63 20 Each
64 64 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.- C Series- (ABB, Schneider MG, legrand, Hager make)- 40A item64 1 Each
65 65 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.- 100/300mA sensitivity DP RCCB- (ABB, Schneider MG, legrand, Hager make)- 40A item65 1 Each
66 66 Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.- C Series (ABB, Schneider MG, legrand, Hager make)- 6 to 32 A item66 4 Each
67 67 Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.- C Series (ABB, Schneider MG, legrand, Hager make)- 63A item67 1 Each
68 68 EARTHING: Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . item68 2 Each
69 69 Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. item69 2 Each
70 70 Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. item70 60 Metre.
71 71 Supplying & laying of 25 x 5mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt. item71 30 R.M.
72 72 U. G. CABLE AND CABLE WORKS: Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make).- 3 & 1/2 Core A2XFY- 120.00 Sq. mm.3 & 1/2 Core armoured U.G. cable item72 40 Metre
73 73 Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)- Core - 3 & 1/2 A2XWY A2XFY- 120.00 Sq.mm 3&1/2 Core U.G. cable in 65 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) item73 10 Metre
74 74 Supplying including installation of cast iron cable marker as specified and directed by the deptt. item74 5 Each
75 75 OVER HEAD LINE: Supplying and fitting fixing of H.T./L.T. danger plate complete as required and as directed by the department. item75 2 Each
76 76 Supplying, installation, testing and Commission of the following indoor Decorative Surface mounted 2' x 2' LED down lighter luminaries of model no-SM365C LED 32 -6500 PSU OD GR / SM365C LED 32 -6500 PSU OD GH / SM365C LED 32 -6500 PSU OD GR /SM365C LED 32 -6500 PSU OD WH/ LSVR01S036SC / LSVR01S0365SN / LSVR01S0365SW/ CRCO10S038HP57G1 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / Jaquar / Wipro make). [CLT] item76 22 Each
77 77 Supplying, installation, testing and Commission of the following indoor Decorative Recess mounted LED down lighter luminaries of model no-LESP01R009XC / LESP01R009XN /LESP01R009XW / L00957R000 / L00940R000 / L00930R000 /LD90-111 - XXX-65-XX complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Jaquar / LT / Wipro make). [CL] item77 5 Each
78 78 NON-SCHEDULE ITEM: LT PANEL: Supplying and installation of metal enclosed wall/floor mounted front operated cubical type switch gear panel suitable for indoor installation conforming to IS: 8623 (Part I & II). Panel should be made of sheet steel and thickness not less than 2mm and structural steel having light section. The panel shall be completely dust tight and vermin proof and shall be painted with anti corrosive and anti condensation type two coats of primer and two coats of paint. All wiring shall be PVC insulated and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of out going feeders from the bottom of the panel. The panel shall be incorporated with double busbar system. The bus bar shall be of high quality copper of uniform cross section. The panel shall consist of the following items (viz. Voltmeter, Ammeter, CT, indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel.- Incommer: - 200A 4P 25 KA MCCB - 1 No. - Bus-Bars: 400 A TPN Electrolytic Copper Bus Bar of Size (30mmX10mm) – 1 set- Digital Panel Mounted Energy (Kwh) Meter- 1No.- Digital Panel mounted Voltmeter - 1 No. - Digital panel mounted Ammeter - 1 No. - Voltmeter Selector Switch - 1 No. - Ammeter Selector Switch - 1 No. - Indicating Lamps - 3 Nos. - CT - 3 Nos. - Fuse holders & Fuse bases suitable for Cylindrical / DIN fuse-links and Fuse - 6 Nos. - Outgoing:- 63 A 4P MCB - 3 Nos.- 40 A 4P MCB - 3 Nos.- 40 A DP MCB - 3 Nos. item78 1 Set
79 79 Supplying, installation, testing and Commission of the following indoor LED Decorative Surface/Pendant mounted type totallly enclosed LED luminaries complete with all accessories such as ballast, starter etc. directly on wall/ceilling including connection mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department. - Superior finish extruded white powder coated pressure die cast aluminium body with High transmitivity, non Yellowing PMMA diffuser with driver and accessories pre-wired upto terminal block assembly. LED Luminaires of make Crompton Cat No. SUPRA-I LWV12-35-CDL LED 35W or equivalent inlcuding lamps etc. complete. [CH] item79 1 Each
80 80 Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade item80 2 Sq.m
81 81 Supply, Fitting Fixing of Shock Treatment Chart item81 2 Each