Repair And Renovation Works For Setting Up Of Ssk At Ghorsala Sc Repair And Renovation Works For Setting Up Of Ssk At Ghorsala Sc Msd, KANUPUR GP MURSHIDABAD-West Bengal

Health And Family Welfare Department has published Repair And Renovation Works For Setting Up Of Ssk At Ghorsala Sc Repair And Renovation Works For Setting Up Of Ssk At Ghorsala Sc Msd. Submission Date for this Tender is 07-03-2020. Building Repair Tenders in KANUPUR GP MURSHIDABAD West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

23717624
Repair And Renovation Works For Setting Up Of Ssk At Ghorsala Sc Repair And Renovation Works For Setting Up Of Ssk At Ghorsala Sc Msd
Open Tender
Indian
West Bengal
KANUPUR GP MURSHIDABAD
07-03-2020

Tender Details

Repair And Renovation Works For Setting Up Of Ssk At Ghorsala Sc Repair And Renovation Works For Setting Up Of Ssk At Ghorsala Sc Msd

Key Value

Document Fees
Refer document
EMD
INR 13146.0 /-
Tender Value
INR 6.57 Lakhs /-

BOQ Items

Name of Work:Repair and Renovation works for setting up of Su-Swasthya Kendra at Ghorsala Sub Centre, Kanupur GP, Raghunathganj-I Block, Murshidabad.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including remo ving, spreading or stacking the spoils within a lead of 75 m. as directed.(a) Depth of excavation not exceeding 1,500 mm. 0.09 cu.m
2 2 Earth work in filling in foundation tren ches or plinth with good earth, in lay ers not exceeding 150 mm. include ing watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work), With earth obtained from excavation 0.018 cu.m
3 3 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. 0.3 sq.m
4 4 I) Cement concrete with graded stone ballast (40 mm size excluding shuttering), (A) [Pakur Variety], (a) 1:3:6 proportion 0.455 cu.m
5 5 Repairing crack in wall by cement grout ing (1 : 2) including widening the crack on the surface (into V section) cleaning and packing the same with cement mortar (1 : 2) and finishing off to match with adjacent surface. (Cement-69 Kg/100 m), At Gr. Fl. 20.85 Rm
6 6 At 1st. Fl. 20.85 Rm
7 7 (A) Stitching crack in brick wall by carefully cutting out face brick 125 mm. deep into the wall, cleaning the gap and filling up the same with precast cement concrete block carefully set in cement mortar (1:3) including mending good damages and finishing the surface to match with adjacent areas complete as per direction.(i) With plain cement concrete blocks(1:1½:3) with stone chips.(a) Block size 250 x 125 x 75 mm., In GR.Fl 8 Nos
8 8 Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. A) Ceiling Gr.Fl 137.169 sq.m
9 9 B) In 1st Fl 114.447 sq.m
10 10 Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. a) In Gr. floor 51.0044 sq.m
11 11 In 1st Floor 45.0044 sq.m
12 12 Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In Ground Floor , Store wall, Exhaust, For pipe line, Groove 0.755 cu.m
13 13 In 1st Floor 0.755 cu.m
14 14 Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.In ground floor including roof.(a) upto 150 mm. thick 2.873 cu.m
15 15 In 1st Floor 0.322 cu.m
16 16 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes., a) Pakur Variety (42 Km), In Gr.Fl 2.55 cu.m
17 17 In 1st Fl 1.8 cu.m
18 18 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. In Gr.Fl, (i) Pakur Variety, Beam, Distance = 42 Km , Lab, Sitting area, Sink 0.285 Cu.m
19 19 In 1st Floor,Beam, Roof slab, Sitting area, Bathroom basin 0.378 Cu.m
20 20 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. Gr.Fl, i) Tor steel/Mild Steel,( Sail/Tata) 0.224 Qt.
21 21 In 1st Floor 0.297 Qt.
22 22 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straightincluding fitting, fixing and striking out after completion of works (upto roof of ground floor), (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In- Charge., \n 3.5775 sq.m
23 23 In 1st Floor 3.25875 sq.m
24 24 Brick work with 1st class bricks in cement mortar (1:6), (b) In superstructure, ground floor 0.7275 cu.m
25 25 (c) In superstructure, 1st floor 0.687 cu.m
26 26 125 mm. thick brick work with 1st class bricks set in cement, sand mortar (1:4) in ground floor. 3.075 sq.m
27 27 In 1st Floor 6.48 sq.m
28 28 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfer ing corners as directed , Gr.Fl, (i) With 1:4 cement mortar, (b) 10 mm thick plaster, 15.064 sq.m
29 29 (i) With 1:6 cement mortar, (c) 15 mm thick plaster, 70.456 sq.m
30 30 (i) With 1:6 cement mortar, (c) 20 mm thick plaster, 61.219 sq.m
31 31 In 1st Floor, (i) With 1:4 cement mortar, (b) 10 mm thick plaster, 10.043 sq.m
32 32 (i) With 1:6 cement mortar, (c) 15 mm thick plaster, 60.011 sq.m
33 33 (i) With 1:6 cement mortar, (c) 20 mm thick plaster, 44.393 sq.m
34 34 Artificial stone in floor, dado, staircase etc with cement\nconcrete (1:2:4) with stone chips, laid in panels as directed\nwith topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).(ii) 25 mm. thick, In Gr.Fl 6 sq.m
35 35 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.A) For Gr. Floor, With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick, (a) Area of each tile above 0.09 Sq.m, (i) Coloured decorative , 26.483 sq.m
36 36 B) In 1st Floor, Add for Lab 27.923 sq.m
37 37 C) In Gr. Floor, (a) Area of each tile upto 0.09 Sq.m, (i) Coloured decorative ,(a) Area of each tile upto 0.09 Sq.m, (i) Coloured decorative 21.4469 sq.m
38 38 In 1st Fl 18.6369 sq.m
39 39 Wall , With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick\ncement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(b) Area of each tile upto 0.09 Sq.m, In Ground Floor 30.345 sq.m
40 40 In 1st Floor 30.345 sq.m
41 41 Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary\npigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor.(iii) Area of each Slab/tile exceeding 0.60 sq.m but not, In 1st Floor 3.76 sq.m
42 42 Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately), (a) Upto area 2.5 Sq.m D, In Gr.Fl 8.88 sq.m
43 43 In 1st.Fl 11.82 sq.m
44 44 Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(h) Neem,Jam, In Gr.Fl 0.076 cu.m
45 45 (h) Neem, Jam, In 1st.Fl 0.076 cu.m
46 46 Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor.iii) 35mm thick shutters with19mm thick panel of size 30 to 45 cm. (b) Sishu, Gamar, Champ, 3.9 sq.m
47 47 (b) Sishu, Gamar, Champ, In 1st.Fl 3.18 sq.m
48 48 Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction. (Cost of concrete will be paid separately) , (b) 40mm X 6mm, 200mm Length 18 Nos
49 49 Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (vi) 100mm. X 50mm. X 1.25mm 12 Nos
50 50 i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (a) 200mm long 6 Nos
51 51 A) Iron door ring of approved quality fitted and fixed with nut and washer complete.(ii) 75mm dia. 16 Nos
52 52 Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete.(iv) 300mm x 19mm dia. bolt. 8 Nos
53 53 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (iii) 100 mm grip x 12 mm dia rod. 8 Nos
54 54 Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of\nall materials, taxes and , all other incidental charges complete. 14.94 Mtr.
55 55 Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm , shall be tapered on both sides to form lock rail. 4.41 sq.m
56 56 Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, \n10-12 Micron thickness Annodizing film Natural white, For 2-Track window : 37.62 Kg
57 57 Supplying, fitting and fixing windows & ventilators with or without integarted grills cionforming to I.S. 1038-1975 and manufactured from rolled steel sections conforming to I.S. 7452-1974 with non- friction projecting type hinges, glazing clips, lugs, locking bracket handle plate, handle, peg stay etc. I/c. hosting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect including glazing. Without integrated grills - in all floors, b) Openable steel windows as per I.S. sizes with side hung shutters and horizontal glazing bars, with or without fixed type ventilators ( the rate , In Gr. Fl, for V 0.506 sq.m
58 58 In 1st . Fl, for V1 0.731 sq.m
59 59 c) M.S integrated grill as per approved design integrated with steel window or ventilator, joints , continiously welded with M.S flats and bars., Gr.Fl 6.328 Kg
60 60 In 1st Floor 9.14062 Kg
61 61 Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than150mm apart complete in all respect as per design including cost of all labour and materials. In Gr. Floor 2.1 sq.m
62 62 In 1st Floor 1.4625 sq.m
63 63 (a) M.S.or W.I. Ornamental grill of approved design joints contin uously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg ./sq .mtr and up to 16 Kg./sq. mtr. In Gr.floor 24.783 Kg
64 64 In 1st floor 24.783 Kg
65 65 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. i) 4mm thick clear glass. 6.84 sq.m
66 66 Square or hexagonal mesh netting made with 18 B.W.G. galvanised wire, fitted and fixed complete as per design (excluding the supporting framework but including local sal wood battens of size 37.5mmx25mm).\nIn ground floor.. (b) 25mm mesh 6.84 sq.m
67 67 (b) 25mm mesh 6.84 sq.m
68 68 Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge), In Gr. Fl, Less Plaster 47.906 sq.m
69 69 In 1st Floor, 103.583 sq.m
70 70 (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. i) On Plastered surface , Gr.Fl.+1st Fl 477.854 sq.m
71 71 (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. 23.372 sq.m
72 72 (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : iv) Two coats (with any shade except white), On Plastered surface, Gr.Fl +1st 477.854 sq.m
73 73 On Timber surface, Gr.Fl +1st 44.07 sq.m
74 74 Other metal Surface, Windows, Grills Etc. 23.37 sq.m
75 75 Applying Exterior grade Acrylic primer of approved quality and\nbrand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish), a) One Coats, Gr. Fl 109.125 sq.m
76 76 1ST Fl. 147.975 sq.m
77 77 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat), a) Normal Acrylic Emulsion 109.125 sq.m
78 78 In 1st floor (Two Coat) 147.975 Sq.m
79 79 Labour for Chipping of concrete surface before taking up Plaster ing work. 1ST Fl. 58.8 sq.m
80 80 (a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification, 1ST Fl. 58.8 sq.m
81 81 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. 1st Fl. 2.94 cu.m
82 82 Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades. 1.848 Kg
83 83 1.5 mm thick Net cement finish in wall, dado, 58.8 sq.m
84 84 Base Prise for supplying & Installation of Water Purified R.O technology minimum 10 Ltr Capacity. 1 Nos
85 85 Main signage of Vinyle Board with ACP Boarder 1800X1200 mm 4.32 sq.m
86 86 10 nos Name plate ( 300x150mm) 10 Each
87 87 Construction of Circular Vat of Dia 1.25 m 1 Each
88 88 ElECTRICAL & Sanitary Plumbing Works 1 Each
89 89 GST 12 Percent 1 Each
90 90 Labour welfare charge 1 Percent 1 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail