Providing 40 Kva Diesel Generator Set And Allied Items For Stp Manesar Distt . Gurugram, Gurugram-Haryana

Haryana Police Housing Corporation Limited has published Providing 40 Kva Diesel Generator Set And Allied Items For Stp Manesar Distt . Gurugram. Submission Date for this Tender is 03-03-2020. Diesel Generators Tenders in Gurugram Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

23713399
Providing 40 Kva Diesel Generator Set And Allied Items For Stp Manesar Distt . Gurugram
Open Tender
Indian
Haryana
Gurugram
03-03-2020

Tender Details

Providing 40 Kva Diesel generator Set And Allied Items For Stp Manesar Distt . Gurugram

Key Value

Document Fees
INR 1000 /-
EMD
INR 11000.0 /-
Tender Value
INR 11.11 Lakhs /-

BOQ Items

Name of Work: Providing 40 KVA DG set and allied items for STP manesar Distt. Gurugram
Sl. No. Item Description Item Code / Make Quantity Units
1 1 HSR ITEMS BI01010001010000000000000515BI0100001112
2 2 Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres. (HSR 6.6 +CP 425%) BI01010001010000000000000515BI0100001113 27.96 % Cum
3 3 Cement concrete 1 : 6 : 12 with brick ballast 40 mm Nominal size in foundation and plinth. (HSR 10.30+CP 450%) BI01010001010000000000000515BI0100001114 5.45 Cum
4 4 Cement concrete 1 : 1.5 : 3 with stone aggregate 20 mm Nominal sie in foundation and plinth.. (HSR 10.42+CP 450%) BI01010001010000000000000515BI0100001115 12.13 Cum
5 5 First class brick work laid in cement sand mortar 1:4 in foundation and plinth. (HSR 11.4 (C.P.@ 650 %) BI01010001010000000000000515BI0100001116 16.9 Cum
6 6 12 mm thick cement plaster 1:4. (HSR 15.5 +CP 600%) BI01010001010000000000000515BI0100001117 71.33 Sqm
7 7 Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 16.3+CP 230%) Ist quality BI01010001010000000000000515BI0100001118 71.33 Sqm
8 8 Applying priming coat with metal primer on New steel or iron work including preparation of surface. (HSR 16.9+CP 230%) Ist quality BI01010001010000000000000515BI0100001119 71.33 Sqm
9 9 Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12+CP 500%) BI01010001010000000000000515BI0100001120 7.74 Qtl
10 10 Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect. (HSR 18.33+CP 500%) BI01010001010000000000000515BI0100001121 49.9 Sqm
11 11 Supplying, hoisting and placing in position tubular trusses including runners, purlins, consisting of steel tubes conforming to I.S. specifications of tested quality duly welded with fillet welds 6 mm thick through-out including wind bracing. Open end of pipe sealed with 3 mm thick plate including the cost of nuts and bolts where bolts connections are specified at flange joints including one coat of ready mixed red oxide zink cromate primer of approved quality assembling and fixed in positon complete in all respect. (HSR 18.14+CP 500%) BI01010001010000000000000515BI0100001122 7.74 Qtl
12 12 EARTHING. (HSR 31.22+CP 350%) BI01010001010000000000000515BI0100001123
13 13 iii)Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as equired. BI01010001010000000000000515BI0100001124 4 Each
14 14 iv)Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) comlete as equired. BI01010001010000000000000515BI0100001125 2 Each
15 15 v)Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. BI01010001010000000000000515BI0100001126 6 Each
16 16 x) Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. BI01010001010000000000000515BI0100001127 6 Rmt
17 17 xi) Providing and fixing 25 mm x 5 mm GI strip in 40 mm dia G.I pipe from earth electrode as required. BI01010001010000000000000515BI0100001128 4 Rmt
18 18 xiv) Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material. BI01010001010000000000000515BI0100001129 12 Rmt
19 19 xv) Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material. BI01010001010000000000000515BI0100001130 27 Rmt
20 20 S/E of under ground cable loose in existing pipe or trenches including necessary connection, digging and refilling of trenches. (HSR 31.26+CP 140%) xxvii)50 Sq. mm 3.5 Core Cable (Armoured) BI01010001010000000000000515BI0100001131 150 Rmt
21 21 Supply and erection of suitable compression type brass cable glands for underground Cable. (HSR 31.28+CP 140%)iv) 70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core . iii) 25 Sqmm to 50 Sqmm Cable 2 to 4 BI01010001010000000000000515BI0100001132 6 Each
22 22 Miscellaneous. (HSR 31.35+CP 130%) (ix) Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. e) 25 sqmm . BI01010001010000000000000515BI0100001133 6 Each
23 23 g) 50 sqmm BI01010001010000000000000515BI0100001134 18 Each
24 24 Supply, installation,testing and commissioning of wall / free standing floor mounting dust and vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet, required hardware 3mm thick bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zinc / Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment / switch wear.Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3mm thick for separately cable alloey to BBC from switch chamber extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring ( copper) and fuse protection (Only outer area on all sides shall be measured) as per HSR 31.63 (C.P @ 0%) BI01010001010000000000000515BI0100001135 27.15 Sqm
25 25 Supplying and fixing of copper bus bar duly tinned by means of SMC/ DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respect as per HSR 31.64 (C.P @ 0%) BI01010001010000000000000515BI0100001136 18 Kg
26 26 Pdg. and fixing digital metering equipment for LT cubical Panel consisting of 96mmx96mm 0-500V, volt meter with selector switch, Amp. meter (of required ratio up to 600/5 amp.) with selector switch and required C.Ts 3 Nos., a set of 3 no phase indicating lamps RYB LED. HSR 31.65 (C.P @ 0%) BI01010001010000000000000515BI0100001137 1 Each
27 27 Supply & fixing of rotary handle for on / off operation of existing MCCB in the LT panel including fixing the same in position with all labour and material required to complete the job in all respect..HSR 31.66 (C.P @ 0%) i) Rotary handle up to 125A, MCCB BI01010001010000000000000515BI0100001138 3 Each
28 28 S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 mtr. below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-incharge of the work. (HSR 31.67+CP 0%) (ii) HDPE pipe 90 / 75 mm outer dia / inner dia. BI01010001010000000000000515BI0100001139 150 Rmt
29 29 Supply and erection of moulded case circuit breaker single pole/four pole on wall or on existing pedestal including bonding to earth and necessary connections. (HSR 31.69) (CP 0%) iv) Four Pole MCCB 6 to 63 Amp BI01010001010000000000000515BI0100001140 1 Each
30 30 v) Four Pole MCCB 100 Amp BI01010001010000000000000515BI0100001141 2 Each
31 31 S/E of heavy duty 4 pole ON LOAD Change load over breaker switch suitable for operation of 415 volt AC supply complete with handle assembling having door interlock and interlocking arrangement on existing panel i/c making necessary connections with petty material required to complete the job. HSR 31.74 (C.P @ 0%) ii) 100 amp 4 pole ON LOAD changeover switch BI01010001010000000000000515BI0100001142 1 Each
32 32 TOTAL HSR BI01010001010000000000000515BI0100001143
33 33 NS ITEM BI01010001010000000000000515BI0100001144
34 34 S/E of MS bucket stand suitable for 6 nos. fire buckets ( without buckets) made out of angle from of size 40 mm x 40 mm x 6mm i/c the cost of welding, labour and two coats of approved paint including one coat of red oxide. BI01010001010000000000000515BI0100001145 1 Each
35 35 S/E of fire buckets of 9 liters capacity made out of 24 gauge GI sheet& duly painted with one coat of red oxide and two coat of approved paint in red colour written with fire as per fire protection complete with necessary sand filling in the bucket and labour etc. BI01010001010000000000000515BI0100001146 6 Each
36 36 S/E of fire existingusher ISI marked C02 type of 4.5 kg capacity as per IS:7285 duly erected/hangs on wall with hooks i/c the cost of hook, screws etc with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer in charge of the work. BI01010001010000000000000515BI0100001147 1 Each
37 37 S/E of fire existingushers ISI marked dry chemical powder type of 4 KG capacity as per IS duly erected/hangs on wall with hooks i/c the cost of hook, screws etc with all labour and material required to complete the job in all respect to the entire satisfaction of the Engineer- in - Charge of the work. BI01010001010000000000000515BI0100001148 1 Each
38 38 Supply & Erection of of hi - rib profilrd sheeting 1000 - 1020 mm cover width 28.30 mm creast 200 - 150 mm centre to centre manufactured from 0.50 mm TCT Hi - Tensile bars galvalum sheet (AZ - 150 gm aluminium zink alloy metallic coating sheet) complete with all labour and petty material required to complete the job i/c carriage, loading , unloading, westage, fixing on existing MS structure with STSC screws, nuts, bolts & washers etc.as required upto entire staisfactrion of Engineer - In - Charge of work. BI01010001010000000000000515BI0100001149 83.5 sqmt
39 39 Supply, Installation, testing and commissioning of 40 KVA water cooled, silent diesel generating set complete with alternator rated at 3 phase, 415 volts, 0.8power factor, 50 cycle per second, 1500 RPM with AMF panel ( Outside the canopy) , Accoustic enclosure and battery charger etc. ( to be installed out door on existing plateform excluding cost of plateform) :- BI01010001010000000000000515BI0100001150 1 Each
40 40 (A)     Diesel Engine:-Engine multy cylinder, developing output BHP as per 40 KVA DG Set, at 1500 RPM, vertical totally enclosed water cooled, comprising compression ignition, electric start, 4 strok high speed diesel engine conforming to IS-4722, ISO – 3046, BS – 5514. The engine shall be complete with all standard and electrical accessories as per standard supply of manufactures. The engine shall be coupled with 3 phase 415 volts 50 cycle, 0.8 PF and 1500 RPM, alternator as per IS 4722/ BIS 2613 rated for 24 hours of continuous operation with 10 % over load capacity for one hour in every 12 hours in every 12 hours and comprising with:- BI01010001010000000000000515BI0100001151
41 41 a) AMF panel of required size complete with all accessories as required. BI01010001010000000000000515BI0100001152
42 42 b)  On/Off start keys BI01010001010000000000000515BI0100001153
43 43 c)   Lube oil pressure guage BI01010001010000000000000515BI0100001154
44 44 d)  Fuel tank having capacity to run the D G Set min. 8 hours in first fill. BI01010001010000000000000515BI0100001155
45 45 e)  Residential silencer of required size and length i/c all necessary material as required. BI01010001010000000000000515BI0100001156
46 46 f) 1 no. 12 volts, 130 AH, DC Mtc. Free batteries with leads and containers. BI01010001010000000000000515BI0100001157
47 47 g)  AVM pads fitted on base frame. BI01010001010000000000000515BI0100001158
48 48 h) The base frame would be fabricated from suitable M.S. channel suitable machined to perfect alignment of the engine and alternator with rigid construction and necessary reinforncement to ensure minimum viberation BI01010001010000000000000515BI0100001159
49 49 i)   Any other accessories to make the generating set functional shall be installed as per manufactures specification BI01010001010000000000000515BI0100001160
50 50 B) battery Charger :-Electronic battery charger shall be installed of required size and rating for charging of battery of D.G. set. BI01010001010000000000000515BI0100001161
51 51 C) Acoustic Enclosure:-It shall be provided as per Technical specification as follows:- BI01010001010000000000000515BI0100001162
52 52 1)   Construction and Painting:- BI01010001010000000000000515BI0100001163
53 53 i)        The enclosure shall be fabricated out of 1.60 mm thick ( 16 SWG ) CRCA sheet silent D.G.Set container shall be of modular construction with the provision to assemble and dismantle easily at site of work. BI01010001010000000000000515BI0100001164
54 54 ii) The base frame shall be made of ISMC of suitable section) BI01010001010000000000000515BI0100001165
55 55 iii) Durable industries system is to be provided on the doors and doors are fitted with high quality EPDM gasket to avoid leakage of sound . BI01010001010000000000000515BI0100001166
56 56 iv) Weather proof anti corrosion treatment to be provided to the entire structure with powder coating. BI01010001010000000000000515BI0100001167
57 57 v) Neutral / Body earthing points at the side of enclosure are to be provided. BI01010001010000000000000515BI0100001168
58 58 vi) Emergency stop push button shall be provided outside the container. BI01010001010000000000000515BI0100001169
59 59 vii) A tube fitting with tube rod for proper light inside canopy shall be provided. BI01010001010000000000000515BI0100001170
60 60 2)       Acoustic Insulation:- BI01010001010000000000000515BI0100001171
61 61 i) Sound proofing of the enclosure shall be done with quality rock wood/ Mineral wood conforming to IS-8133-1933 of 25 mm thickness and density at 30 Kg / M compressed along with 3 mm thick vinyl sheet and non ferrous sheet. BI01010001010000000000000515BI0100001172
62 62 ii) Exhaust pipe is to be thoroughly insulated by covering it with glass wool and further claded with aluminium sheet. BI01010001010000000000000515BI0100001173
63 63 75 db A noise level as per latest central Pollution Control Board (CPCB) BI01010001010000000000000515BI0100001174
64 64 Note:-Any other material required to complete the acoustic enclosure shall be installed as per manufactures specifications.(App. Dnit for Const. of Police station Rohrai Distt. Rewari). BI01010001010000000000000515BI0100001175
65 65 Total NS BI01010001010000000000000515BI0100001176
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail