Special Repair To Bldg No T-5, T-8, T-9, T-13, T-17 & T-32 Of 5 Inf Bde At Along Mil Stn, Likabali-Arunachal Pradesh

Military Engineer Services-MES has published Special Repair To Bldg No T-5, T-8, T-9, T-13, T-17 & T-32 Of 5 Inf Bde At Along Mil Stn. Submission Date for this Tender is 16-03-2020. Building Repair Tenders in Likabali Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

23606752
Corrigendum : Special Repair To Bldg No T-5, T-8, T-9, T-13, T-17 & T-32 Of 5 Inf Bde At Along Mil Stn
Open Tender
Indian
Arunachal Pradesh
Likabali
16-03-2020

Tender Details

Special Repair To Bldg No T-5, T-8, T-9, T-13, T-17 & T-32 Of 5 Inf Bde At Along Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Feb-2020 DRT Extended Date 09-03-2020
2 02-Mar-2020 DRT Extended1 Date 16-03-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR TO BLDG NO T-5, T-8, T-9, T-13, T-17 & T-32 OF 5 INF BDE AT ALONG MIL STN
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Dismantling of plain or corrugated steel sheeting, any gauge, thickness including any pattern roof coverings complete all as specified and as directed. 21032A 249.61 Sqm
2 2 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. 11017A 238.31 Sqm
3 3 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. 11018A 11.3 Sqm
4 4 Dismantling of wrought or mild steel work of any description not otherwise described into primary parts. 21028A 13 Quintal
5 5 S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed. 10046A 1300 Kg
6 6 Preparation of old steel surface of any description not exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge 17033C 5 10 Running Metre
7 7 Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge 17029A 25 Sqm
8 8 Dismantling of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified. 21042B 96.3 sqm
9 9 S & F prelaminated particle board (decorative lamination on one side and other side balancing lamination), 9 mm thick, grade I or II & type IV (Designation PLB-14 or PLB-24), made out of medium density particle board (flat pressed-three layer or multilayer and graded (grade I or grade II), bonded with BWR adhesive), fixed with screws to timber/ steel frame work in ceiling, flat or sloping complete all as specified and as directed. 12050A 96.3 Sqm
10 10 Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm centre to centre to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications and as directed by Engineer-in-charge. 10094A 96.3 Sqm
11 11 Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge. 21004A 20.02 Cum
12 12 M & L for precast cement concrete solid block masonry of grade C(5.0) with concrete M7.5 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate exceeding 10 cm in width and set in cement mortar (1:4) complete all as specified and as directed. 04030A 11.35 Cum
13 13 M & L for precast cement concrete solid block masonry of grade C(5.0) with concrete M7.5 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, 10 cm in width and set in cement mortar (1:4) complete all as specified and as 04036A 86.71 Cum
14 14 Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed. 14001R 234.88 Sqm
15 15 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately. 14011H 61.47 Sqm
16 16 Supply only integral water proofing compound. 04099A 2.62 Kg
17 17 M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed 15009H 100.75 Sqm
18 18 M & L for preparation of new plaster surface of wall and applying two coats of cement base paint complete all as specified and as directed. 15010C 61.47 Sqm
19 19 Demolition of lime concrete of any description and in any position not otherwise specifically provided for 21017A 16.73 Cum
20 20 M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection all as specified and as directed. 13034P 16.73 Sqm
21 21 M & L for filling in position 80/25 industrial grade bitumen mix filler of proportion 80 kg of hot bitumen, 1 kg of cement and 0.25 cubic metre of coarse sand for expansion joints complete all as specified and as directed. 11043B 240 Per cm depth per cm width per Running Metre
22 22 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises 13109A 156.98 Sqm
23 23 Dismantling timber scantlings in framed works, 40 sqcm and over in section, in any position 21020B 0.48 Cum
24 24 M & L for non skid, rectified, colour ceramic floor tiles (group B II), area of each tile exceeding 0.12 sqm but not exceeding 0.22 sqm, length more than 340 mm but less than 460 mm, minimum 8 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed. 13082K 33 Sqm
25 25 M & L for ceramic fully vitrified tiles, coloured ceramic tiles (group B Ia), area of each tile exceeding 0.22 sqm but not exceeding 0.40 sqm, length more than 460 mm but less than 650 mm, minimum 10 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar(1:4) set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed. 13086N 80.25 Sqm
26 26 M & L for glazed, colour ceramic wall tiles (group B III), area of each tile exceeding 0.12 sqm but not exceeding 0.22 sqm, length more than 340 mm but less than 460 mm, minimum 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed. 13081K 43.73 Sqm
27 27 M & L for Makrana doogri marble work 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed. 06117C 1 Sqm
28 28 Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed 08069D 4 Each
29 29 Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed 08072D 5 Each
30 30 Taking down steel windows/ ventilators of any size 10070E 13 Each
31 31 S & F powder coated, minimum thickness 50 micron, aluminium sections for doors, windows, ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame complete all as specified. \r\nNote : (i) Glass panes, wire mesh & handle will be measured & paid separately . \r\n(ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and not paid separately.\r\n(iii) All other minor details including cost of locking arrangement shall be included in the quoted rate. 10089C 485 Kg
32 32 S & F mortice lock, vertical type, mild steel, 4 levers, vertical type, 100 mm size including protective coating of painting fixed in position complete all as specified and directed. 09097B 8 Each
33 33 S & F exposed type hydraulically regulated door closers, universal closer, bottle type (type A), Designation No. 3, suitable for 61 kg to 80 kg mass of doors & 851 mm to 1000 mm width of door, aluminium alloy non porous body and black plate, aluminium alloy piston or pack piston/ pillion, anodized finish not be less than Grade AC 15 of IS 1868 : 1996 with transparent anodic film as per IS 3564: 1995 complete all as specified and as directed. 09154B 8 Each
34 34 Supply & fix sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. 16001F 7.2 Sqm
35 35 S & F solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and as directed. 16015A 25.01 Sqm
36 36 Supply & fix sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty or fixed with beads in square exceeding 0.5 Sqm in each pane complete all as specified and directed. 16002F 17.61 Sqm
37 37 Supply & fix sheet glass, ordinary quality, ground or obscured or frosted, 4.8 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. 16005E 2.75 Sqm
38 38 Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed. 16020A 2.75 Sqm
39 39 S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. 09028F 3 Each
40 40 S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 125 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. 09004C 1 Each
41 41 S & F mild steel sliding door bolts, type I (plate type), size 150 mm, stove enamelled black finish to back plate, straps and staple, electroplated finish with nickel and chromium to hasp and bolt, bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed. 09017A 1 Each
42 42 S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 09083C 2 Each
43 43 S & F in repairs galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed. 09157C 2 Sqm
44 44 S & F floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 140 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 30 & 35 mm thickness of door shutter, fixed in floor complete all as specified and as directed. 09149A 8 Each
45 45 S & F in repairs 20 mm dia harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc. complete all as specified and as directed. 09143C 20 Running Metre
46 46 Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. 18059B 20 Running Metre
47 47 Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 18050B 20 Running Metre
48 48 Demolition of reinforced cement concrete of any description (reinforcement cut as required to facilitate demolition) and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed. 21019C 0.43 Cum
49 49 M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. 10034F 7.42 Kg
50 50 M & L for formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of concrete complete all as specified and as directed. 07009A 0.75 Sqm
51 51 M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. 04041B 0.43 Cum
52 52 Dismantling water tanks capacity exceeding 500 litres but not exceeding 1000 Litres and keeping aside for credit complete all as specified and as directed. 18080H 1 Each
53 53 S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed. 18082D 1 Each
54 54 S & F in repairs 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete 18104K 1 Each
55 55 S & F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed by the Engineer-in-Charge. 18128G 1 Each
56 56 Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. 18059A 30 Running Metre
57 57 Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 18050A 30 Running Metre
58 58 S & F in repairs shower panel as per Model No. C841U99 of Parryware or equivalent of Make as mentioned under Appendix "B" complete all as specified and as directed. 18527A 1 Each
59 59 S & F in repairs angle shower enclosure as per Model No. C840799 of Parryware or equivalent of Make as mentioned under Appendix "B" complete all as specified and as directed. 18527B 1 Each
60 60 S & F in repairs European water closet and seat cover as per Model No. C8906 of Parryware or equivalent of Make as mentioned under Appendix "B" complete all as specified and as directed. 18527C 1 Each
61 61 S & F in repairs health faucet as per Model No. T9941A1 of Parryware or equivalent of Make as mentioned under Appendix "B" complete all as specified and as directed. 18527D 1 Each
62 62 S & F in repairs 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. 18096G 1 Each
63 63 S & F in repairs 15 mm nominal size, nonrising spindle type fancy concealed stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed 18103J 1 Each
64 64 M & L in repairs for cast iron floor trap 50 mm nominal diameter with grating including jointing to waste pipe with lead joints and including necessary concreting in M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 18212G 3 Each
65 65 S & F in repairs toilet paper holder of vitreous china, box type, white fixed to walls with chromium plated brass screws complete all as specified and as directed. 18249B 1 Each
66 66 S & F in repairs wash basin as per Model No. C0462 of Parryware or equivalent of Make as mentioned under Appendix "B" complete all as specified and as directed. 18527E 1 Each
67 67 S & F in repairs 32 mm bore brass chromium plated bottle trap for wash basin with inlet and outlet screwed for pipes or connection including necessary packing, union and caps etc. complete all as specified and as directed by Engineer-in-Charge. 18211A 1 Each
68 68 S & F in repairs pillar cock as per Model No. T2022A1 of Parryware or equivalent of Make as mentioned under Appendix "B" complete all as specified and as directed. 18527F 1 Each
69 69 M & L in repairs for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed. 18150I 2 Each
70 70 Taking down eaves gutters and rainwater pipes (any size or pattern), soil waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store or taken on schedule of credit (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed. 11125A 10 Running Metre
71 71 S & F UPVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge. 18185A 3 Each
72 72 S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge. 18181A 10 Running Metre
73 73 S & F in repairs 600 mm X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. 18337C 1 Each
74 74 S & F in repairs soap dispenser as per Model No. T6413A1 of Parryware or equivalent of Make as mentioned under Appendix "B" complete all as specified and as directed. 18527G 1 Each
75 75 S & F in repairs towel rack as per Model No. T6408A1 of Parryware or equivalent of Make as mentioned under Appendix "B" complete all as specified and as directed. 18527H 1 Each
76 76 Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge. 08095A 4.95 Running Metre
77 77 S & F factory made solid PVC moulded door shutter, 28 to 30 mm thick (stiles) with particle board core, with 2, 4, or 6 raised panel design with 2 mm thick Moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing. 08101A 1.56 Sqm
78 78 M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge. 04029C 8 Cum
79 79 S & F in repairs sinks with drainage board made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers and 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes overall size 915 mm X 460 mm bowel size 410 mm X 330 mm X 160 mm complete all as specified and as directed. 18278B 1 Each
80 80 S & F flexible (coil shaped) PVC waste pipe for sink and wash basin 40 mm dia with length not less than 700 mm connected to PVC waste fittings complete all as specified and as directed. 18372D 1 Each
81 81 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. 19303A 64 Point
82 82 Taking down carefully without point wiring by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) 19304A 10 Each
83 83 M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 19320A 46 Point
84 84 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 19326A 8 Point
85 85 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 19328A 10 Point
86 86 S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 19386A 64 Each
87 87 S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. 19415A 18 Each
88 88 M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 19329A 4 Point
89 89 S & F in repairs step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed. 19505D 8 Each
90 90 M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 19334A 4 Point
91 91 S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 19417A 8 Each
92 92 S & F in repairs ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. 19469D 46 Each
93 93 S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed. 19385A 10 Each
94 94 S & F buzzer, din dong, suitable for single phase, AC, 240 volts complete all as specified and as directed. 19396A 2 Each
95 95 S & F in repairs bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 19394D 2 Each
96 96 Taking down ceiling fan/ exhaust fans, any sweep including disconnection of electric connection and removing the blades in safe for reinstalling complete all as specified and as directed. 19499K 8 Each
97 97 Taking down ceiling fan/ exhaust fany, any sweep by unscrewing the U clamp, cleaning the ceiling fan with moist cloth with detergent powder, scrubbing the old paint with sand paper and painting it with super quality synthetic enamel paint of white colour including filling cavities with filler and rehanging the same after replacing the flexible copper conductor of suitable dia complete all as specified and as directed. 19499J 4 Each
98 98 S & F exhaust fan, AC, 50 Hz, single phase 230 V, 230 mm sweep, 4 pole, heavy duty with louvers, metal body, 4 Nos blades, Insulation Class A, 5 star rated as per Bureau of Energy Efficiency (BEE) including capacitor to ensure power factor more than 0.9 complete all as specified and as directed. 19615E 2 Each
99 99 S & F ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, minimum air delivery 200 m³ per minute, minimum service value 4 m³ per minute per watt, maximum power input 50 watt, 3 Nos metal blades protected with corrosion resistance paints, class I type with double insulation, insulation class A for temperature rise, ISI marked including capacitor to ensure power factor more than 0.9, five star rating as per Bureau of Energy Efficiency complete all as specified and directed by Engineer-in-charge. 19617B 8 Each
100 100 S & F suitable size fan hook made of mild steel including suitable size of clamp for mounting ceiling fan to be attached with RCC roof, truss roof etc. complete all as specified and directed. 19741H 6 Each
101 101 Taking down old unserviceable submain wiring 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface to match the existing surface complete all as specified and as directed. 19507I 75 Running Metre
102 102 Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 2.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good complete all as specified and directed by Engineer-in-charge. (Note 1- Two runs of 4 sqmm cable, one run of 2.5 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) 19509L 75 Running Metre
103 103 S & F heavy mechanical stresses class and -5 temperature class PVC casing/capping of size 25 mm X 16 mm including accessories complete all as specified and as directed. 19817C 50 Running Metre
104 104 S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 19455M 3 Each
105 105 S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 19446J 3 Each
106 106 S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 19445J 18 Each
107 107 S & F in repairs PVC rectangular block for mounting DBs, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 350 mm X 300 mm and 50 mm deep complete all as specified and as directed. 19468C 3 Each
108 108 S & F sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SPN 20 Amps 240 volts complete all as specified and as directed. 19452D 2 Each
109 109 M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge. 19471A 2 Each
110 110 S & F LED tube light fittings nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2000, lumen efficacy of minimum 100 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120° clear, THD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, epoxy powder coated white extruded aluminium channel housing, life span of minimum 50000 working hours as per catalogue No. LHEWEBP7IN1W020 of Havells or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed. 19801Y 15 Each
111 111 S & F LED panel light recess mounted nominal power 28 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 3240, lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, beam angle of 120° clear, THD below or less than 15%, CW available CCT of 4000K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours as per catalogue No. PLUTONEO2X2PLR28WLED840S of Havells or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed. 19918H 15 Each
112 112 S & F LED Bulb/ lamp non-dimmable type 10 watts with high power LEDs as light source and electronic driver complete all as specified and as directed. 19601E 10 Each
113 113 Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. 03006A 27 Cum
114 114 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. 03009A 17 Cum
115 115 Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point 03029A 10 Cum
116 116 Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly. 03019C 8.5 Cum
117 117 Supply & laying unreinforced precast concrete cable cover class LV type 2, flat shape, dimension 300 mm X 180 mm X 40 mm as per IS 5820: 1970 complete all as specified and directed. 19223A 507 Each
118 118 Disconnecting, taking out old unserviceable under ground cable of rated voltage 1100 V, nominal cross sectional area of main conductor 10 sqmm, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) all as specified and directed by the Engineer-in-Charge. 19240E 145 Running Metre
119 119 Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. 19240C 145 Running Metre
120 120 Supply, installation, commissioning and testing in repair factory made, CPRI approved, outdoor type LT panel board of suitable size, made of mild steel sheet of 3.15 mm thick, powder coated, dust & vermin proof, front and rear double doors, compartmentalized, general construction confirming to IS: 8623 (Part 1): 1993, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 100 Amps rated copper bus bar, including mounting on angle iron frame made using angle iron 40 mm X 40 mm X 6 mm complete all as specified and as directed and shall be comprising the followings: - \r\n(a) MCB, four pole with three protected pole (TPN), C-type instantaneous tripping, Rated current 63 A-1 No\r\n(b) MCB, two pole with one protected pole (SPN), C-type instantaneous tripping, Rated current 63 A- 3 Nos\r\n\r\n(Note: The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 40 mm X 40 mm X 6 mm of length 750 mm.) 19920A 1 Each
121 121 Taking down existing old fluorescent tube light fittings/ bulk head light fittings/ ceiling light fittings/ building light fittings including lamp any capacity, any type complete all as specified and as directed. 19801X 30 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail