Military Engineer Services-MES has published Special Repair To Lt Ug Cable For Street Lights From Ganjulama Gate To Triangle Chowk And Other Sanctioned At New Mil Stn Gangtok. Submission Date for this Tender is 25-02-2020. Street Lighting Tenders in Gangtok Sikkim. Bidders can get complete Tender details and download the document.
Name of Work: SPL REPAIR TO LT UG CABLE FOR STREET LIGHTS FROM GANJULAMA GATE TO TRIANGLE CHOWK AND OTHER SANCTIONED AT NEW MIL STN GANGTOK | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | SCHEDULE 'A' PART-I (B/R WORKS) | BI01010001010000000000000515BI0100001113 | ||
2 | 1.01 | Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm and removing surplus soil to a distance n.exc 50 mtrs complete all as specified and directed by the Engr-in-Charge | BI01010001010000000000000515BI0100001114 | 25 | Each |
3 | 1.02 | Material & labour for PCC (1:3:6), type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified & as directed. | BI01010001010000000000000515BI0100001115 | 0.7 | Cum |
4 | 1.03 | Supply and fix 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheets of any colour and any pattern as approved having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as in roof complete all as specified and directed . | BI01010001010000000000000515BI0100001116 | 93 | Sqm |
5 | 1.04 | Supply and fix 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheets of any colour having tensile strength of 550 Mpa as in ridges, valley, eaves, etc fixed with self tapping screws complete all as specified and directed . | BI01010001010000000000000515BI0100001117 | 2 | Sqm |
6 | 1.05 | S&F for mild steel tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1998 grade St-240 including one shop coat of zinc chromate primer paint (including preparation of surface) at contractor's workshop before fabrication and fixing complete all as specified and as directed. | BI01010001010000000000000515BI0100001118 | 10 | KG |
7 | 1.06 | S&F Rolled section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters ,hand rails ,running rails and guides for sliding doors; fixed with angle cleat or other connecting plates confirming to Fe-290 (Gde-E-165) complete all as specified and as directed. | BI01010001010000000000000515BI0100001119 | 665 | KG |
8 | 1.07 | M&L for preparation of old or treated wooden steel surfaces of any description exc 10 cm width or grith and applying two coats of synthetic enamel paint complete all as directed.. | BI01010001010000000000000515BI0100001120 | 65 | Sqm |
9 | 1.08 | Excavation in trenches not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out as in soft/loose soil for foundation etc complete all as directed by the Engr-in-Charge. | BI01010001010000000000000515BI0100001121 | 106.81 | Cum |
10 | 1.09 | Excavation over areas, n.exc 1.5m deep and getting out in soft/loose soil complete all as directed. | BI01010001010000000000000515BI0100001122 | 2 | Cum |
11 | 1.1 | Material & labour for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete etc complete all as specified & as directed. | BI01010001010000000000000515BI0100001123 | 5.31 | Cum |
12 | 1.11 | Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cms in thick as in soft/loose soils complete all as directed by the Engr-in-Charge. | BI01010001010000000000000515BI0100001124 | 89.13 | Cum |
13 | 1.12 | Removing excavated material to a distance n.exceeding 50m and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as directed by the Engr-in-Charge. | BI01010001010000000000000515BI0100001125 | 21.03 | Cum |
14 | 1.13 | Material and labour for hardcore of gauge n.exc.63mm (using broken stone or boulders) deposited, spread and levelled in layers not exc.15cm thick, watered and rolled/rammed to a true surface complete all as directed. | BI01010001010000000000000515BI0100001126 | 3 | Cum |
15 | 1.14 | M&L for 30mm thick PCC (1:2:4), type B-1 (using 20 mm graded stone aggregate ) as in sub base of floor etc complete incl finish the surface even and rough to freceive the floor finish all as specified and as directed. | BI01010001010000000000000515BI0100001127 | 15 | Sqm |
16 | 1.15 | M&L for 75mm thick PCC (1:3:6), type C-2 (using 40 mm graded stone aggregate ) as in plinth protection; path / hardstanding etc laid in bays / panels not exc. 2.00 Sqm each including construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and smooth without using extra cement complete all as specified and as directed | BI01010001010000000000000515BI0100001128 | 16.1 | Sqm |
17 | 1.16 | Material and labour for Lacquer coated precast chequered cment concrete tiles made with grey cement and pigment of size 300 x 300 x 25 mm thick as in pavement / footpath, set and jointed in neat cement slurry and pointed with cement laid over and including screed bed/ bedding layer of 15mm thick in cement mortar (1:4) complete all as directed. | BI01010001010000000000000515BI0100001129 | 59 | Sqm |
18 | 1.17 | Material & labour for non skid coloured ceramic tiles of 7 to 8 mm thick (Square/ rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors etc conforming to IS- 13712, grade B-II - (a) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including cement screed bed / bedding layer of 15mm thick in cement mortar (1:6) complete all as specified and as directed.. | BI01010001010000000000000515BI0100001130 | 10 | Sqm |
19 | 1.18 | Materials & labour for coloured glazed ceramic tiles of size (300 mm x 200 mm / 350 mm x 250 mm / 450mm x 350mm ) x 7 mm thick as in vertical surfaces such as skirting/dado / riser to steps etc conforming to IS - 13712 grade IB-III set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including cement screed bed / backing layer of 10mm thick in cement mortar (1:4) complete all as specified and as directed. | BI01010001010000000000000515BI0100001131 | 4 | Sqm |
20 | 1.19 | M&L for mild steel TMT bars,10mm dia and over cut to length, bent to shape required including cranking ,bending spirally, hooping for columns, hookings ends and binding with and including MS wire(annealed) not less than 0.9 mm dia or securing with clips complete all as specified & as directed. | BI01010001010000000000000515BI0100001132 | 60 | KG |
21 | 1.2 | Material & labour for Mild steel TMT bars 6mm to 8mm dia as in stirrups, spacers and binders cut to length, bent to shape required, including cranking , bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified & as directed. | BI01010001010000000000000515BI0100001133 | 24 | Each |
22 | 1.21 | Material & labour for RCC 1:2:4, type B1 (using 20mm graded stone aggregate) as in, beams, cantilever, bressummers, lintel,column etc including necessary form work complete all as specified & as directed.\nNOTE : Re-inforcement shall be measured and paid separately. | BI01010001010000000000000515BI0100001134 | 1 | Cum |
23 | 1.22 | Material & labour for precast PCC 1:3:6 type C1 (by using 20mm graded stone aggregate) block masonry with solid blocks, exc 10 cm in width and setting in CM 1:6 complete all as specified and as directed by the Engr-in-Charge. | BI01010001010000000000000515BI0100001135 | 9.5 | Cum |
24 | 1.23 | Material & labour for rendering 15 mm thick in CM (1:3) with using water proofing compound @ of 3% by weight of cement on fair faces of brick or concrete surfaces, finished even & fair with using extra cement complete all as directed. | BI01010001010000000000000515BI0100001136 | 23 | Sqm |
25 | 1.24 | Material & labour for rendering 15 mm thick in CM (1:4) on other than fair faces of brick or concrete surfaces, finished even & fair with using extra cement complete all as directed. | BI01010001010000000000000515BI0100001137 | 48 | Sqm |
26 | 1.25 | Supply only water proofing compound all as directed. | BI01010001010000000000000515BI0100001138 | 2 | KG |
27 | 1.26 | M&L for preparation of newly plastered surfaces of walls and applying two coats of weather proof exterior emulsion paint white or tinted over a coat of primer over a coat of wall care putty of required thickness as per manufacturers instruction complete all as specified and directed. | BI01010001010000000000000515BI0100001139 | 23 | Sqm |
28 | 1.27 | M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion , white or tinted over a coat of wall care putty of required thickness as per manufacturers instruction complete all as specified and directed. | BI01010001010000000000000515BI0100001140 | 48 | Sqm |
29 | 1.28 | Materials & labour for 0.63mm thick CGI sheeting , ISI marked with 275 grams per sqm zinc coating with two corrugation side laps fixed with 'L' type or 'J' type or cranked hook bolt and washers in roof covering / walls etc etc complete all as specified & as dirceted. | BI01010001010000000000000515BI0100001141 | 115 | Sqm |
30 | 1.29 | S&F steel ventilator, with top hung shutter including hinges with fixed type MS handles , peg stay and tower bolt but with additional sash bars MS flats for fixing wire gauge complete all as specified & as directed. | BI01010001010000000000000515BI0100001142 | 1 | Sqm |
31 | 1.3 | S&F 3mm thick figured glass pin head type and glazing with oil putty including steel pin in square n.exc 0.5sq. m in each pane fixed to steel frame complete all as specified & as directed. | BI01010001010000000000000515BI0100001143 | 1 | Sqm |
32 | 1.31 | S&F Galvanised 0.63mm thick Plain mild steel sheeting in ridges, hips, valley gutter drip and straight flashing (length and grith as fixed) with grade of zinc coating 275 as in roof all as specified. | BI01010001010000000000000515BI0100001144 | 10 | Sqm |
33 | 1.32 | Supply & fix PVC SWR half round 150/160mm dia with round edges including all accessories like bend ,T etc for eaves gutter complete as specified and directed. | BI01010001010000000000000515BI0100001145 | 20 | RM |
34 | 1.33 | M&L for roughning surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust etc complete all as directed. | BI01010001010000000000000515BI0100001146 | 86 | Sqm |
35 | 1.34 | Material & labour for non skid coloured ceramic tiles of 7 to 8 mm thick (Square/ rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm as in vertical surfaces such as skirting/dado / riser to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including cement screed bed / backing layer of 10mm thick in cement mortar (1:4) complete all as specified and as directed. | BI01010001010000000000000515BI0100001147 | 37 | Each |
36 | 1.35 | Taking down cement plaster of any description on brick or stone walls, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by the Engr-in-Charge. | BI01010001010000000000000515BI0100001148 | 7 | Sqm |
37 | 1.36 | Material & labour for non skid coloured ceramic tiles of 7 to 8 mm thick (Square/ rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm as in vertical surfaces such as skirting/dado / riser to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including cement screed bed / backing layer of 10mm thick in cement mortar (1:4) complete all as specified and as directed. | BI01010001010000000000000515BI0100001149 | 7 | Sqm |
38 | 2 | SCHEDULE 'A' PART-II (E/M WORKS) | BI01010001010000000000000515BI0100001150 | ||
39 | 2.01 | Supply, Laying, jointing & testing 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium stranded conductor laid in trenches or passing through pipe of cross sectional area 16 sqmm 4.00 core with all fixing & connecting accessories complete all as specified & as directed.\nNote:- \n(i) Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this schedule.\n(ii) The rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes."\n | BI01010001010000000000000515BI0100001151 | 900 | Per RM |
40 | 2.02 | All as per Srl item No 2.01 here-in- before but for 10 Sqmm 4.00 Core complete all as specified and as directed. | BI01010001010000000000000515BI0100001152 | 690 | Per RM |
41 | 2.03 | Supply and laying DWC HDPE Pipe 50mm OD, SN-4 including fittings laid in trenches/ fixed to pole/laying under road crossing/fixed on pavement walls with clamps complete all as specified and as directed | BI01010001010000000000000515BI0100001153 | 1450 | RM |
42 | 2.04 | Supply and installation solar all-in-one street lighting with smart integrated solar street light with built in mono crystalline solar panel, Lithium Ferro phospate (LiFeP04) battery, MPPT charge controller and PIR Sensor with colour temperature range 6000-6500K of power rating 20 watt, panel capacity 50Wp and battery capacity 24 Ah, with autonomy of 2 days complete fixed in existing solar street light poles complete all as specified and as directed by engineer in charge Make:- Havells Cat No LHSTAKU7CBAF020 or equivalent make as specified. | BI01010001010000000000000515BI0100001154 | 4 | Each |
43 | 2.05 | Supply & Fix Street light control panel with timer , contactor rating 65 Amp 3 Pole/230V- Analog time switch, MCB rating 65Amp TPN, Max load 12KW, complete all as specified & directed.\nMake: INDOASAIN Cat No TL065AB0 or equivalent make as specified. | BI01010001010000000000000515BI0100001155 | 1 | Each Job |
44 | 2.06 | M& L for PCC (1:3:6) type C1 using 20mm graded stone aggregate as in coping and other similar bends including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and as directed. | BI01010001010000000000000515BI0100001156 | 1.5 | Per Cum |
45 | 2.07 | Supply and fixing GI tubing 100mm dia medium grade ISI Marked laid in trenches/laid under floor including all fittings such as elbow, union, reducer, tees, bends etc and short length complete all as specified and as directed by Engr In | BI01010001010000000000000515BI0100001157 | 318 | Per RM |
46 | 2.08 | S & F cast iron Sluice valves ,100mm dia ISI marked with IS 14846 complete suitable for 100mm bore of pipe, both ends flanged of class PN 1.6 and drilled stainless steel spindle, CI gate with brass ring and iron wheel handle cast iron cap stuffing box etc including joints and joining materials i.e. nuts, bolts, whshers, rubber insertion sheet etc all as specified and directed. | BI01010001010000000000000515BI0100001158 | 1 | Each |
47 | 2.09 | Supply & fix 50 mm bore Gun metal Gate valves, ISI Marked with iron wheel head, screwed both rends for GI pipe complete all as specified and as directed including taking down old one. | BI01010001010000000000000515BI0100001159 | 1 | Each |
48 | 2.1 | Supply and fix in repair, Street light cable junction box made of polycarbonate, ''halogen free and weather proof', for outdoor installation (with metric knockouts for cable entry) IP-66 protection including short cable entry gland tread type with lock nut, four way bakelite terminal with brass studs and nuts, GI flat strip clamps of size 25mm X 3mm with bolts, nuts and washers for fixing with MCB one 06 Amps inside the junction box complete all as specified & as directed. \n(Make: HENSEL Cat No. KG 9002 or equivalent model of as specified.) | BI01010001010000000000000515BI0100001160 | 15 | Each |