Ht/Lt Network Improvement By Way Of Replacement Of Barbed Wire/Worn Out Poles/Trees In Various Feeders Under The Jurisdiction Of Electric Sub Division Chararisharief , Ed Budgam , Kpdcl . , Office of the Executive Engineer, ED Budgam, KPDCL-Jammu And Kashmir

Power Development Department has published Ht/Lt Network Improvement By Way Of Replacement Of Barbed Wire/Worn Out Poles/Trees In Various Feeders Under The Jurisdiction Of Electric Sub Division Chararisharief , Ed Budgam , Kpdcl . . Submission Date for this Tender is 15-02-2020. Transmission Line Tenders in Office of the Executive Engineer, ED Budgam, KPDCL Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

23377457
Ht/Lt Network Improvement By Way Of Replacement Of Barbed Wire/Worn Out Poles/Trees In Various Feeders Under The Jurisdiction Of Electric Sub Division Chararisharief , Ed Budgam , Kpdcl .
Open Tender
Indian
Jammu And Kashmir
Office of the Executive Engineer, ED Budgam, KPDCL
15-02-2020

Tender Details

Ht/Lt Network Improvement By Way Of Replacement Of Barbed Wire/Worn Out Poles/Trees In Various Feeders Under The Jurisdiction Of Electric Sub Division Chararisharief , Ed Budgam , Kpdcl .

Key Value

Document Fees
INR 1000 /-
EMD
INR 29120.0 /-
Tender Value
INR 14.56 Lakhs /-

BOQ Items

Name of Work: HT/LT network improvement by way of replacement of barbed wire/worn out poles/trees in various feeders under the jurisdiction of electric sub division Chrarisharief ED Budgam, KPDCL.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Work items identified for HT/LT network improvement 11111
2 1.01 Carraige from store upto site, Erection,testing and commisioning of 9mtr long Steel Tubular Poles complete with base plate(300x300x5mm), top cap, including digging of pit (1/6th of pole height) positioning etc, complete in all respect as per REC Standard. 111 75 Nos
3 1.02 Carraige from store upto site, Erection,testing and commisioning of 8 mtr long Steel Tubular Poles complete with base plate(300x300x5mm), top cap, including digging of pit (1/6th of pole height) positioning etc, complete in all respect as per REC Standard. 112 15 Nos
4 1.03 Carraige from store upto site,laying ,stringing,tensioning , binding of ACSR Conductor of sizes complete in all respects as per standards 113
5 1.04 100 Sqmm 114
6 1.05 50 Sqmm 115 10 Km.
7 1.06 30 sqmm 116 1.5 Km.
8 1.07 Supply,Carraige upto site,Installation,testing and Commissioning of Line Type 11KV linkset with current capacity 400 amps for sectionalization 117 6 Set
9 1.08 Supply,Carraige upto site and fixing of GI F Top with clamps duly fabricated as per site requirement including clamps(50x6 mm), GI Nuts & Bolts,washers etc complete in all respects as per REC standards 118 525 KGS
10 1.09 Supply,Carraige upto site and fixing of GI V Cross arm/5 Ft long GI cross arm (75*40*6) with suitable size of GI angle braces as per site requirement duly fabricated as including clamps(50x6 mm), GI Nuts & Bolts,washers etc complete in all respects as per REC standards 119 1275 KGS
11 1.1 Supply,Carraige upto site and fixing of GI channel iron Cross arm 9Ft long (75*40*6mm) duly fabricated including clamps(50x6 mm), GI Nuts & Bolts,washers etc complete in all respects as per REC standards 120 600 KGS
12 1.11 Supply,Carraige upto site,Carraige upto site,Installation,testing and Commissioning of 11 kV Disc Insulators (polymer) Complete with fitting(45KN),complete in all respects as per REC standards 121 20 Set
13 1.12 Supply,Carraige upto site,Installation,testing and Commissioning of 11 KV Pin Insulators (polymer) with Pins (5KN),complete in all respects as per REC standards 122 225 Set
14 1.13 Supply,Carraige upto site,Installation,testing and Commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2NO..), anchor plate (200x 200 x 6 mm), nut-bolts, 2 NO. turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete with all fittings as per REC Standards 123 6 Set
15 1.14 Supply,Carraige upto site and installation of Danger Plates with Clamps 124 75 NO.
16 1.15 Supply,Carraige upto site and installation of Anti Climbing devices 125 75 NO.
17 1.16 Supply,Carriage upto site of installation 50x6 mm GI Mukhi clamps along with GI Nuts & Bolts . 126 45 KGS
18 1.17 Supply,installation,testing and commissioning of 16 KN porceline schakle insulator 127 45 Nos
19 1.18 Cement bottoming of S T poles in 1:2:4 mix,up to 1/6th plantation depth of pole below ground, 9" above ground,circular with radius 6" around the pole girth/surface ,top surface tappered outwards as per the diagram given in technical specifications 128 90 JOB
20 1.19 Painting of Poles with two coats of Red Oxide and one coat of alimunium paint 129 90 JOB
21 1.2 Earthing of steel tubular poles using 8SWG GI wire (115 turn of 50mm dia spiral ) in 1.5 m deep pit as per REC specification 130 90 JOB
22 1.21 Branch Cutting of Trees coming in close proximity with HT/LT network 131 3 KMS
23 1.22 Dismantling/carriage up to stores of old D /W /PCC poles 132 40 Nos
24 1.23 Dismantling ,carriage up to stores of old diaplidated/barbed conductor 133 6 KMS
25 1.24 Dismantling ,relaying/re stringing /re binding of conductor of sizes for HT/LT Network 134 5 KMS
26 2 NOTE: \n\n1.The rates quoted by the bidder for all the line items shall be inclusive of GST/freight/insurance/storage/installation/testing and any other charges FOR various sites in the identified feeders for HT/LT network improvement under the jurisdiction of electric sub division Chararisharief\n\n
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail