Power Development Department has published Ht/Lt Network Improvement By Way Of Replacement Of Barbed Wire/Worn Out Poles/Trees In Various Feeders Under The Jurisdiction Of Electric Sub Division Chadoora , Ed Budgam , Kpdcl . . Submission Date for this Tender is 15-02-2020. Transmission Line Tenders in Chadoora Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Name of Work: HT/LT network improvement by way of replacement of barbed wire/worn out poles/trees in various feeders under the jurisdiction of electric sub division Chadoora ED Budgam, KPDCL. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Work items identified for HT/LT network improvement | 11111 | ||
2 | 1.01 | Carraige from store upto site, Erection,testing and commisioning of 9mtr long Steel Tubular Poles complete with base plate(300x300x5mm), top cap, including digging of pit (1/6th of pole height) positioning etc, complete in all respect as per REC Standard. | 111 | 113 | Nos |
3 | 1.02 | Carraige from store upto site, Erection,testing and commisioning of 8 mtr long Steel Tubular Poles complete with base plate(300x300x5mm), top cap, including digging of pit (1/6th of pole height) positioning etc, complete in all respect as per REC Standard. | 112 | 33 | Nos |
4 | 1.03 | Carraige from store upto site,laying ,stringing,tensioning , binding of ACSR Conductor of sizes complete in all respects as per standards | 113 | ||
5 | 1.04 | 100 Sqmm | 114 | 9 | Km. |
6 | 1.05 | 50 Sqmm | 115 | 10 | Km. |
7 | 1.06 | 30 sqmm | 116 | 5 | Km. |
8 | 1.07 | Supply,Carraige upto site,Installation,testing and Commissioning of Line Type 11KV linkset with current capacity 400 amps for sectionalization | 117 | 20 | Set |
9 | 1.08 | Supply,Carraige upto site and fixing of GI F Top with clamps duly fabricated as per site requirement including clamps(50x6 mm), GI Nuts & Bolts,washers etc complete in all respects as per REC standards | 118 | 791 | KGS |
10 | 1.09 | Supply,Carraige upto site and fixing of GI V Cross arm/5 Ft long GI cross arm (75*40*6) with suitable size of GI angle braces as per site requirement duly fabricated as including clamps(50x6 mm), GI Nuts & Bolts,washers etc complete in all respects as per REC standards | 119 | 1921 | KGS |
11 | 1.1 | Supply,Carraige upto site and fixing of GI channel iron Cross arm 9Ft long (75*40*6mm) duly fabricated including clamps(50x6 mm), GI Nuts & Bolts,washers etc complete in all respects as per REC standards | 120 | 2000 | KGS |
12 | 1.11 | Supply,Carraige upto site,Carraige upto site,Installation,testing and Commissioning of 11 kV Disc Insulators (polymer) Complete with fitting(45KN),complete in all respects as per REC standards | 121 | 20 | Set |
13 | 1.12 | Supply,Carraige upto site,Installation,testing and Commissioning of 11 KV Pin Insulators (polymer) with Pins (5KN),complete in all respects as per REC standards | 122 | 339 | Set |
14 | 1.13 | Supply,Carraige upto site,Installation,testing and Commissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2NO..), anchor plate (200x 200 x 6 mm), nut-bolts, 2 NO. turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete with all fittings as per REC Standards | 123 | 6 | Set |
15 | 1.14 | Supply,Carraige upto site and installation of Danger Plates with Clamps | 124 | 113 | NO. |
16 | 1.15 | Supply,Carraige upto site and installation of Anti Climbing devices | 125 | 113 | NO. |
17 | 1.16 | Supply,Carriage upto site of installation 50x6 mm GI Mukhi clamps along with GI Nuts & Bolts . | 126 | 99 | KGS |
18 | 1.17 | Supply,installation,testing and commissioning of 16 KN porceline schakle insulator | 127 | 99 | Nos |
19 | 1.18 | Cement bottoming of S T poles in 1:2:4 mix,up to 1/6th plantation depth of pole below ground, 9" above ground,circular with radius 6" around the pole girth/surface ,top surface tappered outwards as per the diagram given in technical specifications | 128 | 146 | JOB |
20 | 1.19 | Painting of Poles with two coats of Red Oxide and one coat of alimunium paint | 129 | 146 | JOB |
21 | 1.2 | Earthing of steel tubular poles using 8SWG GI wire (115 turn of 50mm dia spiral ) in 1.5 m deep pit as per REC specification | 130 | 146 | JOB |
22 | 1.21 | Branch Cutting of Trees coming in close proximity with HT/LT network | 131 | 3 | KMS |
23 | 1.22 | Dismantling/carriage up to stores of old D /W /PCC poles | 132 | 80 | Nos |
24 | 1.23 | Dismantling ,carriage up to stores of old diaplidated/barbed conductor | 133 | 10 | KMS |
25 | 1.24 | Dismantling ,relaying/re stringing /re binding of conductor of sizes for HT/LT Network | 134 | 8 | KMS |
26 | 2 | NOTE: \n\n1.The rates quoted by the bidder for all the line items shall be inclusive of GST/freight/insurance/storage/installation/testing and any other charges FOR various sites in the identified feeders for HT/LT network improvement under the jurisdiction of electric sub division Chadoora.\n\n |