Jodhpur Vidyut Vitaran Nigam Limited has published Construction Of 33 Kv S/S Building And Boundary Wall At Industria Iv Phase Balotra. Submission Date for this Tender is 14-02-2020. Substation Tenders in Balotra Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work: Construction of 33 KV Sub Station Building & Boundary Wall at RIICO IA IV Phase Balotara | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Earth work in exacavation in foundation trenches or drains including dresing of sides and ramming of bottoms, lift up to 1.5 Mtr.. Including taking out the excavated soil and depositing and refilling or jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soil (B-2/1.8) | 156 | P.Cum | |
2 | 2 | Providing and laying in position cement cocrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). (B-15/3.2.8) | 28 | P.Cum | |
3 | 3 | Random Rubble stone masonry for foundation and plinth in Cement Sand mortar above 30 CM thick wall in : cement Mortar 1:6: (1 Cement : 6 Sand). ( B-36/6.1.7) | 32 | P.Cum | |
4 | 4 | Random Rubble stone masonry for superstructure above plinth level one storey height above 30cm. Thick walls in: Cement Mortar 1:6 (1- Cement : 6 - sand) Extra over item No. 6.1 & 6.2 for: Wal upto 30cm. And less thickness. (B-41&42/6.2.7+6.3.2) | 61 | P.Cum | |
5 | 5 | A extra for facing as per design and detailed specification incl additionl cost of stone Carse rubble facing 1 st sort.(B-36/6.4.1) | 152 | P.Sqm | |
6 | 6 | A extra for facing as per design and detailed specification incl additionl cost of stone Carse rubble facing 2nd sort.(B-36/6.4.2) | 125 | P.Sqm | |
7 | 7 | Add extra for rock facing using Jodhpur white sand stone with porper projection and chisal dressing of edges of stone 2 line dressing for building corners,jambs including uniform joints.(B-37/6.4.8) | 152 | P.Sqm | |
8 | 8 | Providing and laying in position specified grade of reinforced cement concrete including curing, compactino, finishing with rendering in cement sand mortar 1:3 and making good the joints excluding the cost of centering, shuttering and reinforcement -All work up to plinth level: 1:1.5:3 (1cement :1.5coarse sand :3graded stone aggregate 20mm nominal size) ( B-19/4.1.2) | 39 | P.Cum | |
9 | 9 | -do- Add extra for respective grade of RCC work CC 1:1.5:3 M-20 grade mix in lintels, chajjas, shelves, vertical, horizontal individually or forming box, louvres, bands, roof, suspended floor & fabrics and fins etc. up to floor three level (B-20/4.3.1) | 4 | P.Cum | |
10 | 10 | Add extra for respective grade of RCC work CC 1:1.5:3 M-20 grade mix for suspended floors, roofs griders, blocks, sill and beams etc, upto floor three level (B-20/4.3.1) | 21 | P.Cum | |
11 | 11 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of columns etc, up to plinth level. (B-21/4.11) | 180 | P.Sqm | |
12 | 12 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways with woodan members and removal of forms for super structure upto 4.5 m height above plinth level, for pillasters builtresses, plinth and striing course (B-22/ 4.12.2) | 200 | P.Sqm | |
13 | 13 | P & Fabrication steel rainforcement for RCC work including cutting, bending placing in position and binding complete including cost of binding wire in founcatino, etc. upto plinth level. cold twisted (IS:1786) bars. Up to floor three level (B-23/4.13.2) | 6400 | P.Kg | |
14 | 14 | Providing and laying cement concrete including curing, compaction etc. complete CC 1:3:6 using stone aggregate 20mm nominal size in super structure excl. cost of centering and shuttering. (B-15/3.2.4+B-17/3.4.(1) | 6 | P.Cum | |
15 | 15 | Providing and laying cement concrete including curing, compaction etc. complete CC 1:3:6 using stone aggregate 20mm nominal size up to P.L. excl. cost of centering and shuttering. (B-15/3.2.4 | 1 | P.Cum | |
16 | 16 | Half Brick masonry in superstructure with bricks of class designation 75 with nominal hoop reinforcement (2 Nos. 6 mm MS bar) at every 4 th course in for hoop rejnforcement 1 Sqm. 6 mm MS bar 2X2X1.00=4.00 Cement Motar 1:6 Half brick masonary (B-32/5.8.4+5.9) | 38 | P.Sqm | |
17 | 17 | Brick work in partition in super structure up to third storey 7 Cm. thick (brick on edges) using bricks of class designation 75 with nominal hoop rainforcement (2 Nos 6mm MS bar) at every fourth course in (B-32&33/5.10.3) | 8 | P.Sqm | |
18 | 18 | Supplying and fixing in walls machine cut and polished stone shelves, tands and sills in CM 1:3 with machine cut edges: Kota stone 25 to 30 mm thick. (B-39&40/6.16.4) | 40 | P.Sqm | |
19 | 19 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm, long embedded in cement concrete block 15x10x10cm. Of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain galss panes 4 mm thick with coper glazing clips and special metal sash putty of approved make or mental beading with screws complete including priming coat of approval steel primer, exdluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung (openable) (B-91/9.28.3) | 16 | P.Sqm | |
20 | 20 | Fixed (B-91/9.28.2) | 1 | P.Sqm | |
21 | 21 | Supplying and fixing fixed wire gauge of 14mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance. (B-92/9.31) | 16 | P.Sqm | |
22 | 22 | Providing and fixing Square bars or other flat welded to window, ventilatiors etc. (B-92/9.32) | 75 | P.Kg | |
23 | 23 | Deep groove pointing on stone masonry in white cement sand mortar (1:3) with colour pigment of approved shade for all type of masonry incl. racking of joint as per specification complete in all respect. (B-131&132/12.43(a) | 152 | P.Sqm | |
24 | 24 | Plaster on new surface on walls in cement sand moprtar 1:6 including racking of joint etc. complete fine finished: 25 mm thick. (B-127/12.9.1) | 300 | P.Sqm | |
25 | 25 | Plaster on new surface on walls in cement sand moprtar 1:6 including racking of joint etc. complete fine finished: 20 mm thick.(B-127/12.9.2) | 65 | P.Sqm | |
26 | 26 | 6 mm thick plaster to ceiling in C M 1:3 (B-129/12.22) | 215 | P.Sqm | |
27 | 27 | Providing and laying 20 to 25 mm glazed tiles pieces over roofs treatment having colour and shades appd by Engg Incharge over 25 mm thick under layer in cement sand mrotar 1:4 with app of cement sullery I/e finishing of joints with ordinary cement , curring ets comp in all resp.washing with acid (B-109/10.53) | 115 | P.Sqm | |
28 | 28 | Providing & fixing precast cement concrete copying 1:2:4 mis 50mm thick complete as per specification : -- 50mm - (B-156/15.6.1) | 30 | P.Sqm | |
29 | 29 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10 cm long embedded in cement concrete bl,ocks 15x10x10 cm of 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) or with wooden plugs and screws or rawl plugs and screws or with fixing clups or with bolts and nuts as require including fixing or necessary butt hinges and screws and applying a priming coast of approval steel primer. (B-187/9.13) | 110 | P.Kg | |
30 | 30 | Providing & laying Chequerred coloured plain cement concrete embossed of specially manufactured non slipping tiles of approved make 20 mm thick laid on 20 mm thick bed of cement mortar 1:6 jointed with neat cement slurry complete. (B-119/11.33+11.34) | 6 | P.Sqm | |
31 | 31 | Providing and fixing unplasticized Poly Vinyl Chloride (UPVC) SWR pipes type `B' for sciland waste dischareg system (IS : 13592: 1992 marked) of approved quality/ make.110mm dia (S-47/3.45.2) | 33 | PRM | |
32 | 32 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal, dehydreresin in glue both sides with approved steel fittings complete as per Annexure ‘A’Commercial Veneer both side 30 mm thick shutter (B-74/8.18.2) | 10 | P.Sqm | |
33 | 33 | Polished other than Blue Kota stone slab in steps, walls pillars having fine machine cut edges laid on 12 mm (Av.) thick cement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match the polishing complete 30 mm thick slab area 2001 to 5000 sq. Cm. (B-120/11.37.3 - 11.37.4) | 6 | P.Sqm | |
34 | 34 | Polished other then Blue Kota Stone flooring skirting, laid over 20 mm thick base of C.M. 1:4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :For area of each slab up to 2000 to 5000 Sq. Cm :(A) 30 mm thick slab.(B-119&120/11.35.3B-11.37.4) | 100 | P.Sqm | |
35 | 35 | 20 mm thick slab area upto 900 Sq.Cm.(B-120/11.37.1-11.37.4)| | 9 | P.Sqm | |
36 | 36 | Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20x10x2mm and brackets with flat iron diagonals 20x5mm, size with top and bottom rail of T-iron 40x40x6mm, with 40 mm dia steel pulleys / ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension).With 100 mm opening when closed. (B-89/9.20.2) | 7 | P.Sqm | |
37 | 37 | Providing and fixing Ist quality standard White Ivory Glazed Tiles ISI marked [IS:13753] of size 300mm x 200mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster).Category-I : Kajariya, Jhonson, Orient, Somani make etc. (B-56/7.3A) | 26 | P.Sqm | |
38 | 38 | Providing and fixing Ist quality MAT finished ceremic tile size 300x300mm confirming to IS : 13753 colour such as white, grey, ivory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slsurry including nicely finished joints using water proof joint filler power (Untile or Roffe make) and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete incl. 20 mm thick plaster in CSM 1:4 the cost of cement plaster). (B-59/7.4)+Note I | 5 | P.Sqm | |
39 | 39 | Suppling and fixing of rolling shutters of approved make, made of 80x1.25mm ms laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangments for in side and out side locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3 cm long wire spring grade No 2 and ms top cover 1.25 mm thick for rolling shutters as per design (Clear openable area to be measured for payment.).(B-90/9.23) | 8 | P.Sqm | |
40 | 40 | Supply & fixing steel shutter (Almirah type) with 18 gauge steel border & steel shutter including locking arrangement and painting etc. complete fixed on wall with joint fast (iron clip) (B-99/9.65) | 6 | P.Sqm | |
41 | 41 | Structural steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level up to 4.5 Mtr. height in R.S. Joists flats, tees, angles and channels.(B-86/9.4) | 500 | P.Kg | |
42 | 42 | Providing corrugated asbestos cement 6 mm thick sheet roofing and fixing with GI, J or L-hooks, bolts and nuts 8 mm dia GI plain and bitumen washers complete excluding the cost of purlines, rafters and trusses :Upto 600 pitch.(b-104/10.34.1) | 14 | P.Sqm. | |
43 | 43 | Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering =All up to plinth leve1:2:4 (1Cement :2 Course Sand 4 Graded stone aggregate 20 mm nominal size (B-15/3.2.3) | 0.5 | P.Cum | |
44 | 44 | P&F wind ties of reqd. flat iron section incl. making holes as reqd. duly painted with red oxide paint complete.(b-105/10.37) | 16 | P.Kg | |
45 | 45 | Providing batta (gola) 75mm x 75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design. (B-101./10.8) | 10 | P.Rmtr. | |
46 | 46 | Making grooves as per design in plaster 10mm to 20mm wide. (B-128/12.20) | 62 | P.Rmtr | |
47 | 47 | White washing with whiting to give an even shade including all scafforlding: New work (three or more coats): (B-133/12.44.1) | 500 | P.Sqm | |
48 | 48 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer. (B-12.51.1) | 40 | P.Sqm | |
49 | 49 | Painting with weather coat paint (Asin paint/ I.C.I./Berger or eq. ISI make paint) two or more coat to give an even shade on new work.(b-141/12.88) | 75 | P.Sqm | |
50 | 50 | Painting with enamel paint of apprived brand and manufacture to give an even shade: Two or more coats on new work. (B-137/12.68.1) | 115 | P.Sqm | |
51 | 51 | Providing & fixing anodizing alumium work (Anodizing to be got done from approved Anodizer) for doors, windows, ventilators and partition with extruded built up standard tubular and other sections of approved make confirming to IS : 733 and IS : 1285 anodised transparent 81 dyed to required shade according to IS : 1868 (Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gas at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required inlcuding cleat angle Aluminum snap beading for glazing/paneling, C.P. Brass/ Stainless Steel screws, Al. Tower bolt & Al. handle & Al. Aldrop etc. all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and peneling to be paid for separately). For Fixed portion (B-173/16.1.1) | 50 | P.Kg. | |
52 | 52 | For shutters of doors, windows & ventilators incl. providing and fixing hinges/ rollers etc. and making provision for fixing of fittings wherever reqd. (lockes shall be paid for separately).(B-173/16.1.2) | 40 | P.Kg. | |
53 | 53 | Providing and fixing glazing in aluminium door, window, vintilator shutters and partitions etc. with PVS/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (Cost. of aluminium snap beading shall be paid in basic item.)with glass panes of 5.0 mm thickness (weight not less than 13.75 Kg/Sqm) as per IS : 2835 (B-174/16.3.2) | 7 | P.Sqm | |
54 | 54 | P&F double action hydraulic floor spring of approved brand and manufacture to aluminium door shutter confirming to IS : 6315 incl. costof cutting floors as reqd. embedding in floor and cover plate etc. complte as per direction of Engineer in charge. (B-174/16.4) | 2 | Each | |
55 | 55 | P&F expanded grill made of anodised aluminium as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminium window/ vent with reqd. screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.(B-174/16.5) | 7 | P.Sqm | |
56 | 56 | Providing and fixing brass lock without handle for aluminium door, or approved quality, make & design as directed by Engineer inc harge (B-174/16.6) | 1 | Each | |
57 | 57 | P/L 60 mm thick factory made plastic coating designer cememt concrete interlocking paver block of strength as per I.S. code made by block making machine with strong vibratory compation and approved size and shape/design laid in required colour and pattern over and incl. 20 mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer -in-charge (Appd. by SE (Civil) Jodhpur | 35 | P.Sqm | |
58 | 58 | Filling in plinth with locally available river shingle under floors including watering ramming consolidating and dressing complete including cost of shingles sand.with all led & lift.(B-8/1.33+G-48/5.1) | 105 | P.Sqm | |
59 | 59 | Supply and fixing chittar or equivalent stone slab perchits with making edges and top surface level in cement mortar 1:3 complete finishedUpto 2.15m span white ashlar (B-46/6.50.1) | 2 | PSqm | |
60 | 60 | Providing and laying damp-proof course with cement concrete grade M-150 (1:2:4) mortar prepared with 1 % solution of water-proof compound) including two coats of hot blown bitumen (2 Kg. Per Sqm.) complete as per specification with glass strip 3 mm thick at a distance of 1 Meter interval :50 mm thick.(B-156 & 157/ 15.2-(15.8+15.9) | 5 | PSqm | |
61 | 61 | P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (I.S. : 2556 Mark) with 100mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm. (S-1/1.2.2) | 1 | Each | |
62 | 62 | P & F European type white glazed vitreous china Ist quality W.C. pan (IS:2556 Mark) with P or S trap including cutting and making good the wall and floor.(S-1/1.4) | 1 | Each | |
63 | 63 | P & F Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall : PVC with PVC bend as per IS 7231(S-4/1.22.2) | 1 | Each | |
64 | 64 | P&F water cover closer seat covers with brass hinges complete Solid PVC [ISI marked] grade-1 white for EWC (S-2/1.8.2) | 1 | Each | |
65 | 65 | P&F Jet spray for water closet with C.P. copper tube flange of approved make(S-13/1.62) | 1 | Each | |
66 | 66 | P & F WVC wsh basin (Ist quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (I.S. : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make. 25 mm G.I. waste pipe complete including cutting & making good the wall. : Size 510 mm x 440mm (S-6/1.39.2) | 2 | Each | |
67 | 67 | P & F G.I. pipes (Internal Work) with G.I. fittings (IS: 1239 Mark) & MS clamps including cutting and making good the walls and floors: B class Exposed on wall 15 mm nominal bore exposed on wall (S-15/2.1.1) | 50 | P.Rmtr. | |
68 | 68 | P & F G.I. pipes (Internal Work) with G.I. fittings (IS: 1239 Mark) & MS clamps including cutting and making good the walls and floors: B class Exposed on wall 25 mm nominal bore (S-15/2.1.3) | 20 | P.Rmtr. | |
69 | 69 | P & F G.I. pipes (External Work) with G.I. fittings (IS: 1239 Mark) & MS clamps including cutting and making good the walls and floors: B class 15 mm dia (S-15/2.2.1) | 75 | P.Rmtr. | |
70 | 70 | P & F Bib Cock (IS:8931 Mark) Superior quality of approved make : Brass 400 gm. 15 mm nominal bore.(S-17/2.7.1) | 1 | Each | |
71 | 71 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make C.P. Brass bib cock, 15 mm nominal bore.(S-17/2.7.3) | 4 | Each | |
72 | 72 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15 mm Brass (IS:8931 marked).(S-18/2.12.1) | 4 | Each | |
73 | 73 | P & F Ball Cock ( IS : 1703 Mark) with Rod & P.V.C. Ball complete: Brass wt. 400 gm., 15mm. (S-18/2.11.1) | 1 | Each | |
74 | 74 | P & F 15 mm. Dia Connection Pipe of approved quality/make: PVC pipe with C.P. Brass nuts upto length. 450 mm. (S-19/2.13.3) | 3 | Each | |
75 | 75 | P & F Flush Cock/Flush Valve (IS: 9758 Mark) for WC of approved quality make: Brass / Gun metel Half-turn wt. 1 kg. of approved quality/ make, 25 mm nominal bore (S-20/2.14.9) | 1 | Each | |
76 | 76 | P & F Full-way Value (IS: 778 Mark) or wheet valve of approved make. Gun - metal 25 mm nominal bore. (S-20/2.15.3) | 1 | Each | |
77 | 77 | P & F Full-way Value (IS: 778 Mark) or wheet valve of approved make. Gun - metal 15 mm nominal bore. (S-20/2.15.1) | 1 | Each | |
78 | 78 | P & F PVC Storege Tank (IS : 12701 marked indicating the BIS license No.), of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 ltr. capacity (S-23/2.26.3) | 1 | Each | |
79 | 79 | P & F UPVC SWR. pipes grade 'B' for sciland wast discharge system (IS :13592-1992 marked) of approved make (S-44/3.45) 75 mm dia (S-47/3.45.1) | 10 | P.Mtr. | |
80 | 80 | P & F UPVC SWR. pipes grade 'B' for sciland wast discharge system (IS :13592-1992 marked) of approved make 110 mm dia (S-47/3.45.2) | 30 | P.Mtr. | |
81 | 81 | P & F UPVC SWR. pipes grade 'B' for sciland wast discharge system (IS :13592-1992 marked) of approved make (S-47/3.46) 100 mm dia cowel (S-48/ 3.46.30) | 1 | Each | |
82 | 82 | P & F UPVC SWR. pipes grade 'B' for sciland wast discharge system (IS :13592-1992 marked) of approved make 100 mm dia Tee with door ( S-48/3.46.17) | 2 | Each | |
83 | 83 | P & F UPVC SWR. pipes grade 'B' for sciland wast discharge system (IS :13592-1992 marked) of approved make 110 mm dia bend 87.5 dg. (S-57/3.46.4 ) | 15 | Each | |
84 | 84 | P & F UPVC SWR. pipes grade 'B' for sciland wast discharge system (IS :13592-1992 marked) of approved make 110 mm dia shoe coupler (S-47/13.46.1 ) | 15 | Each | |
85 | 85 | P & F Square - month gully trap 'A' grade (IS: marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40 mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type. Trap size 150 x 100 mm, R.C.C. cover with frame, Internal Chamber size 300 x 300mm. (S-41/3.5.1- S-41/3.33+3.35.7)) | 2 | Each | |
86 | 86 | Construction of manhole in all type of soil inner size 90x60 cm. thick masonary in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring making channels, 80mm thick stone slab covering with 40 mm thick M-15 grade C.C. flooring R.C.C cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50mtr. lead. Depth up to 0.5 M (S-36/3.21.1 - S-41/3.33+3.35.4) | 3 | Each | |
87 | 87 | Construction of soakage well in all type of soil 300mm thick dry masonry, top and bottom 300mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1:3, Ralthal, Kharanja, 40mm thick M-15 grade C.C. flooring, earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr. : Size 240 cm. dia outside & 240 Cm. Depth. (S-38/3.24.3) | 1 | Each | |
88 | 88 | Construction of septic tank in all type sof soil with 40cm thick masonry in CM 1:6 15cm thick CC bed of 1:5:10 M-15 grade CC flooring & over stone slab covering, 80mm thick slab jointing of slab in CM 1:3, Ralthal, Kharanja, 50mm thick stone partiton walls, 20mm thick plaster in CM 1:6 finished with neat floating cement, 4Nos C.I. foot rests of approved design, two No. 450mm dia RCC cover with frame, earth work etc. complete as per approed drawing incl. disposal of surplus earth wtihin a lead of 50mtr. IS 2470 (Part-I) 1985. Size 200x100x130cm (for 10users)(S-40/3.29-S-41/3.33+S-42/3.35.2)) | 1 | Each | |
89 | 89 | Const of CC chamber 125 mm dia on with stainless steel grating ( S-45/ 3.40.4 ) | 4 | Each | |
90 | 90 | Making connection to G I main to Distibution i/c all fitting upto 25 mm dia ( S-16/2.3.1) | 1 | Each | |
91 | 91 | P&F looking mirror of PVC frame of appd make ( Atul or eq ) size 500x400 mm (S-9/1.48.1) | 2 | Each | |
92 | 92 | P&F towel rail or ring of appd quality or make Cp brass towel rail with bracket 600X20 mm heavy duty. (S-10/ 1.50.4) | 1 | Each | |
93 | 93 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make on surface/ recessed ISI marked MMS ( IS:9537 P - III ) PVC condute & it's accessories, round tiles,18 SWG M.S. box with earth terminal, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required.(E020100) Short poing (upt 3 mtr.)(E020101 Gr-II | 8 | P.Point | |
94 | 94 | Medium point (Upto 6.0 Mtr.)(E020102) | 13 | P.Point | |
95 | 95 | Long point (Upto to 10.0 Mtr.)(E020103) | 12 | P.Point | |
96 | 96 | Supplying and drawing FR PVC insulated and unsheathed flexible copper conductor (IS:694) of 1.1 kv grade of approved make in exisisting surface or recessed conduit/casing capping including making connections etc. as required. Group-2 (E040100) 2x2.5 sq.mm +1X1.5 sq mm (E040108) | 100 | P.Rmtr. | |
97 | 97 | 2x4.0 sq. mm+1x2.5 sq. mm (E040117) | 90 | P.Rmtr. | |
98 | 98 | Wiring of 3 pin 6amp. Light plug point with 1.5 sqm. FR PVC insulated unsheathedstd fiexible copper conductor 1.1.kv grade and 1.5 mm nmninal size FR PVC insulated unsheathedstd fiexible copper earth conductor 1.1.kv grade (IS:694) of approved make in surface / recessed ISI marked MMS (IS:9537 P-III) PVC conduct & its accessoreis, 18 swg M.S. box with earthing terminal 6A swith 3.0 mm thick phenolic laminated sheet, zinc planted brass screws, cup washers, making connections, testing etc. as required. group 2 on board. (E020701) | 15 | P.Point | |
99 | 99 | Supply & fixing of power plug point accessories on 18 SWG metal box of size 175x100x60 mm on surface or in recessed with suitable size phenolic laminated sheet cover including cost cost of 6 pin 16amp. Switch & socket out let making connection etc. as required (E040500) Group 2) | 6 | Each | |
100 | 100 | P & F surface/recessed type 10mm thick Teack wood board duly antitermite treated, varnished and fixed by using guttes/PVC fasterners of following size as required. 375x450mm Group-1 (E050905) | 2 | Each | |
101 | 101 | P & F IP-65 / IP-66 protected LED street light luminaire on existing bracket. Fixture made from powder coated single piece pressure die cast aluminium housing with Heat dissipation fins on housing with High Power LEDs of CREE / NICHIA / OSRAM / PHILIPS make. DIffuser / Glass cover for ensuring IP65 protection for Lamp & control gear compartment, System Lumen output of 1500 - 8500 High Power LED. Integrated Driver shall be high efficiency having efficiency > 85% and in compliance to IEC standards System life of 25,000 Burning Hours with 70% of initial Lumens maintained. Fixture shall be in CE Compliance. LED street light fixture 20-25 watt Gr-1 (E203411) | 4 | Each | |
102 | 102 | P & F strip type fluorscent tube fitting fabficated from CRCA sheet and fninshed with powder coating/stove enamel paint /(extruded non corrosive UV resist EP chennel) complete with accessories low loss copper chowk , starter, starter seat / Electronic chock with terminal block duly prewired with copper conductor including making connection, testing etc. as required. (without tube) 1x28watts group-1 with EB (E190104) | 8 | Each | |
103 | 103 | P & F fluorescent tube-light rod in existing fixture.triphosphos coated (Min 5 star ratting) 28 watt group -1 (E190732) | 8 | Each | |
104 | 104 | Pipe Earthing as per IS:3043 with perforated 3.0 Mtr.. Long, 40mm dia, 'B' class GI Pipe including all accessories like nut, bolts, reducer, nipple, wiremeshed funnel and CC finished chamber covered with hinged type with locking arrangement CI cover, C.I. Frame of size 300mmx300mm and embodying the pipe complete with alternate layers salt and coke / charcoal , testing of earth resistance as required. (E150100) | 1 | Each | |
105 | 105 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required. group-1 0.5 A to 5 A rating E060111 | 4 | Each | |
106 | 106 | 6 A to 32 A rating E060112 | 4 | Each | |
107 | 107 | P&F 240/415 V isolator conforming to IS:13947-III/ IEC 60947-3 on existing board / sheet including making connections with lugs , testing etc. as required. Double pole Isolator 30 A / 40 A rating E060231 group-1 | 2 | Each | |
108 | 108 | P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. Single door (single phase)12 Way E060514 group-1 | 1 | Each | |
109 | 109 | S & L following sizes of earth wire / strip in horizontal or vertical run in ground / surface /recess incl. rivrting soldering saddles making connection complete etc. As reqd. 10 swg. GI wire( hot dipped ) wire (E-150706) | 10 | P.Rmtr. | |
110 | 110 | P&F 18 swg. M.S. Recessed fan box hexagonal/round of size 130 mm dia. Depth 75mm, 12mm dia rod fan hook with 100mm length extended on each side. Group-1 (E170600) | 8 | Each | |
111 | 111 | SITC of ISI mark (IS:8472) self priming monoblock pump set of approved make. TEFC, permanent split capacitor type (PSC), fitted with thermal overload protection, mechanical seal, 1440/1500 RPM, single phase (180 to 240 V) including cost of harware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively. 0 .50 HP, 1-# (6-28) Mtr.(52-12) LPM Texmo make Group-1(E260813) | 1 | Each | |
112 | 112 | S & F double ball bearing capasitor start, Aluminium body and blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm PVC insulated flesible copper conductor Making connection , testing etc. as reqd. 1200 mm sweep. group-1 E170403 | 8 | Each | |
113 | 113 | P & F socket size flush type 120/280 watt rotary 5 step fan regulator I/C making connection testing etc.as reqd.group-1( E072200) | 8 | Each | |
114 | 114 | S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required. 25 mm | 30 | P.Rmtr. | |
115 | 115 | S & F of Street light bracket made out from following size of ' B ' class GI pipe with heavy duty pole clamp, Saddles suitable fastners etc. as required. 32 mm Dia. (E203903) Gr.1 | 4 | P.Rmtr. | |
116 | 116 | P & F ISI marked ding dong/musical chime bell including making connection testing etc. as required.E 072700 Gr II | 1 | Each | |
117 | 117 | P & F of decorative round/square shape surface mounting ceilng fitting complete with holder,aluminium anodized back plate glass globe of approved design,prewired terminal block making connection,testing etc. as required as approved by Engineer in charge 250 mm E 192003 Gr I | 1 | Each | |
118 | 118 | P & F two pin energy efficient compact fluorscent lamp in existing holder/fixture as required. 11 watt (E191901) Gr.1 | 1 | Each | |
119 | 119 | P & F of ventilating fans, Capacitor start, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required.E171103 Gr.II | 2 | Each | |
120 | 120 | Earth wok in excavation in founcation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr.. Including taking out the excavated soil and depositing and refilling or jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soil (B-2/1.8) | 202 | P.Cum | |
121 | 121 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering. All work up to plinth level. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). (B-16//3.2.8) | 58 | P.Cum | |
122 | 122 | Random Rubble stone masonary for foundation and plinth in Cement Sand mortar for above 30 CM thick wall in: Cement sand mortar 1:6 (B-41/6.1.7) | 85 | P.Cum | |
123 | 123 | Random Rubble stone masonary for Super structure in Cement Sand mortar 1:6 for upto 30 CM thick wall in: B-41&42(6.2.7+6.3.2) | 111 | P.Cum | |
124 | 124 | (b)…do... For above 30 cm thickness | 5 | P.Cum | |
125 | 125 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished: 25mm thick in CSM 1:6 (B-142/12.9.1) | 329 | P.Sqm | |
126 | 126 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished: 25mm thick in CSM 1:4 ( B-142/12.8.1) | 14 | P.Sqm | |
127 | 127 | Pointing on stone maosnry in cemen sand mortar 1:3 (1 cement : 3 sand) Flush & rulled pointing (B-146/12.36.1) | 506 | P.Sqm | |
128 | 128 | Pointing on stone maosnry in cemen sand mortar 1:3 Deep Groved pointing (B-146/12.36.4) | 86 | P.Sqm | |
129 | 129 | P&F precast cement concrete copying 1:2:4 mix 50 mm thick complete as per specification. (B-177/15.6.1) | 90 | P.Sqm | |
130 | 130 | Painting with weather coat paint (Asin paint/ I.C.I./Berger or eq. ISI make paint) two or more coat to give an even shade on new work.(B-141/12.88) | 352 | P.Sqm | |
131 | 131 | Painting with enamel paint of apprrived brand and manufacture to give an even shade: Two or more coats on new rok.(B-152/12.68.1) | 128 | P.Sqm | |
132 | 132 | P&F steel gate grating & grills made of angle, tee, square bar or other flates black pipe with holdfast and fittings completes as per design and drawing including cutting welding and fabrication with priming coat of red oxide (B-99/9.19) | 1702 | P.Kg | |
133 | 133 | Cement concrete flooring grade 1:2:4 (1 - cement : 2 coarse sand : 4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complte: 50mm thick with 20mm thick nominal size aggregate (B-126/11.3.3) | 5 | P.Sqm | |
134 | 134 | Providing stone slab covering over drains including filling of joints in cement sand mortar 1:3 with 35 mm thick cement concrete flooring 1:2:4 mix complete with good finish with: Stone slab 60 to 75 mm thick average. (B-116/10.17.2) | 9 | P.Sqm | |
135 | 135 | P & F and fixing 1 mm thick M.S. sheet garrage door shutters with frame of 40x40 x 6 mm. Angle iron 3 mm M.S. gusset plates at the junction and corners including all fitting and applying a coat of approved steel primer. (Excluding cost of frames) Using flats 30x6mm for diagonal braces and central cross piece. (B-100/9.22.3) | 1 | P.Sqm | |
136 | 136 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 15cm deep and disposal of rubbish lead up to 50mtr. And lift up to 1.5 mtr. All kind of soil. (B-6/1.34.1) | 3000 | P.Sqm | |
137 | 137 | Structural steel work in single section fixed without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level up to 4.5 mtr. height in R.S. joist flats, tees, angles and channels.(B-98/9.1) | 280 | Kg | |
138 | 138 | Add for using gavlvanized barbed wire instead of black barbed wire. (B-105/9.59+9.61) | 658 | Mtr. | |
139 | 139 | Providing batta gola 75mmx75mm in CC 1:2:4 I/C finished with cement morter in CM 1:3 B-115/10.8) | 15 | P Rmt | |
140 | 140 | Fining with neat cement (punning)(B-143/12.15) | 18 | P.Sqm | |
141 | 141 | P&L CC i/c curring compection etc comp. Mix 1:2:4 ( B-21 / 4.1.3 ) Up to plingth | 1 | P,Cum | |
142 | 142 | P&L CC i/c curring compection etc comp. Mix 1:2:4 for super structure | 0.5 | P,Cum | |
143 | 143 | Add extra for piller masonery i/c bed plates as per spcification ( Bed plates tobe paid saperately ( B-42/ 6.3.3) | 9 | P,Cum | |
144 | 144 | Add extra for facing as per design and detailed specification i/c add cost of stones C R II sort ( B-42/6.4.2) | 290 | P.Sqm | |
145 | 145 | Filling in plinth with locally available river shingle under floors including watering ramming consolidating and dressing complete including cost of shingles sand.with all led & lift.(B-8/1.33) | 26 | P.Cum | |
146 | 146 | Providing and laying in position specified grade of reinforced cement concrete including curing, compactino, finishing with rendering in cement sand mortar 1:3 and making good the joints excluding the cost of centering, shuttering and reinforcement -All work up to plinth level: 1:1.5:3 (1cement :1.5coarse sand :3graded stone aggregate 20mm nominal size) ( B-19/4.1.2) | 21 | P.Cum | |
147 | 147 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of columns etc, up to plinth level. (B-21/4.11) | 68 | P.Sqm | |
148 | 148 | P & Fabrication steel rainforcement for RCC work including cutting, bending placing in position and binding complete including cost of binding wire in founcatino, etc. upto plinth level. cold twisted (IS:1786) bars. Up to floor three level (B-23/4.13.2) | 1700 | P.Kg | |
149 | 149 | Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 (3.5.(i)) | 59 | P.Cum | |
150 | 150 | S&F of interloking Conc. blocks pavements having thickness 80mm as per drawing & tech sp. clause 1503( 6.7.1) | 391 | P.Sqm | |
151 | 151 | S/F of office steel table size 4'x2'6"x2'6" with 3 drawers having separate lock and partitions below each drawers sheet 22g, squre pipe 1", 16g . Top of table having 18mm ISI marked particle board with teak wood beading and polish and fixed on squre pipe 1" and one footrest of same section. | 1 | Each | |
152 | 152 | Supply and fixing of standard size steel office chair full arm with Maharashtra Cane seat back in tubular pipe 1" 16g 6 sut pipe inserted in 1" pipe at every turn or pipe . Seat of size 430x380 resting over pipe & back to be holded on pipe dully painted with enamel paint of superior quality. | 3 | Each | |
153 | 153 | Supply of steel 3 seated chair set made of iron 62" in length and each seat of size 17"x18" with hand rest structure made of round pipe 2" and square pipe 2"x1" and half inch round pipe frame in which perforated sheet 20g is fixed which is duly painted with red oxide and enamel paint of suprior qua;lity. | 1 | Each | |
154 | 154 | S/F of steel stool 12"x12"x18" with 19mm board sunmica top with beading pipe 1", 18g with angle frame. | 1 | Each | |
155 | 155 | S/F of precast hydraulic pressed precast kerb stone after excavating reqd. section over 20mm th. base of CM1:6 incl. painting black/white alternating, jointing/pointing in CM1:4 of cross section size 15cmx27cm M-15 concrete mix one corner edge having rounding. | 220 | PRm | |
156 | 156 | Supply and planting of different varities of tree/shurbs etc. by making pit of size 600x600x600mm incl.removal of rubbish, stone and refill with good earth. Watering of plant as per requirement and ensuring its servival upto 3 months taking all safety/precautionary measures complete in all respect as desired and directed by Engineer Incharge Neem/ Sharesh having size 900 to 1500mm | 10 | Each | |
157 | 157 | Bonganinvilear of different varieties having ht 600mm to 900mm | 40 | Each | |
158 | 158 | Suppling& laying and Trans. Of gravel mooram binding material -do- complete all lead and lift | 30 | P Cum | |
159 | 159 | Supply & fixing direction and place identification board made out of 2mm thick MS sheet framed to angle iron 40X40X5 mm and two vertical posts of angel iron of size 65x65x6 mm 3 m long with hold fast stove enameled paint reflective letter symbol complete of size 90cmX60cm. | 1 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail