Public Works Department-PWD has published Proposed Works Of Jorhat Engineering College , Jorhat Under The Tejasvi Navadhitamastu Edu-Infra Funds ( Tneif ) Under Sopd-Ods During The Year 2018-19 ( Construction Of G Plus 2 Library Building At Jorhat Engineering College ) . Submission Date for this Tender is 04-02-2020. Civil Work Tenders in Jorhat Assam. Bidders can get complete Tender details and download the document.
Name of Work: Proposed works of Jorhat Engineering College, Jorhat under the TEJASVI NAVADHITAMASTU EDU-INFRA FUNDS (TNEIF) under SOPD-ODS during the year 2018-19 (Construction of G+2 Library Building at Jorhat Engineering College) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(A) Up to a depth of 2.00m below the existing ground level.\n(a) In ordinary soil\n | item1 | 1623.31 | Cum |
2 | 2 | (B) Extra over item no.1.1(A) above for each 1m depth or part thereof beyond the initial depth of 2m | item2 | 1117.54 | Cum |
3 | 3 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\n(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. | item3 | 1088.74 | Cum |
4 | 4 | Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.\n(b) Other than Guwahati city\n | item4 | 1841.4 | Cum |
5 | 5 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop 1cement: 3 sand :6 coarse aggregate by volume\n | item5 | 76.38 | cum |
6 | 6 | Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. \nb) 50mm thick | item6 | 1375 | sqm |
7 | 7 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \n(I) Using Mixer Machine\n(A) In substructure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop. 1:1.5:3\n | item7 | 277.98 | cum |
8 | 8 | (B) In super structure from plinth level up to 1st floor level. i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. \nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop. 1:1.5:3\n\n | item8 | 834.46 | cum |
9 | 9 | Extra over item Nos. 6 above for each subsequent floor or part thereof above the 1st floor level. | item9 | 243.75 | cum |
10 | 10 | TIMBER SHUTTERING (FORMWORK)\nProviding form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\n(b) Using 25mm thick plank\n | item10 | 154.6 | Sqm |
11 | 11 | Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:\nColumns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face\n | item11 | 863.3 | Sqm |
12 | 12 | Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.\n(a) For depth not exceeding 1.0M.\n | item12 | 2078.09 | Sqm |
13 | 13 | Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.\n(a) Floors etc. upto 200mm in thickness.\n | item13 | 3048.25 | Sqm |
14 | 14 | Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. | item14 | 165.83 | Sqm |
15 | 15 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling.\n | item15 | 2191.92 | Sqm |
16 | 16 | Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.\n(I) In Sub-structure upto plinth level including dewatering if necessary\n(a) In proportion 1:3.\n | item16 | 103.23 | Cum |
17 | 17 | 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)\n(A) 112mm thick brick wall\n"(a) In cement mortar in proportion 1:4. \n(1 cement:4 sand)"\n | item17 | 2169.27 | Sqm |
18 | 18 | Extra for brick walling for each subsequent floor or part thereof above the 1st floor level.112mm thick brick/ R.B wal | item18 | 907 | Sqm |
19 | 19 | Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)\n"b) Executive range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make"\ni) Of size 800mmx800mm and above\n | item19 | 4743.75 | Sq.m |
20 | 20 | Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).\ni) Of size 300mmx600mm and above\n | item20 | 253.26 | Sq.m |
21 | 21 | Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade. | item21 | 638.87 | Sq.m |
22 | 22 | Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.\niii)Executive range-2 (Sizes 600 mm x600mm and above)\ni) Nitco made\na). Imperia Series- Gres Tiles\n | item22 | 151.02 | Sq.m |
23 | 23 | Providing polished tiles of approved quality, size, shape of specified thickness on pavers over a base of 100mm compacted sand gravel including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). \n(A) SUN ROCK HIGH CTS Tiles (Pavers)\n(a) Silicon (Pavers) 80 mm thick\n | item23 | 42 | Sq.m |
24 | 24 | 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.\nc) In cement mortar 1:5\n | item24 | 97.6 | Sq.m |
25 | 25 | Extra over item no 6.2.1 to 6.2.3 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed.\nc) In cement mortar 1:5\n | item25 | 97.6 | Sq.m |
26 | 26 | 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.\nb) In cement mortar 1:4\n | item26 | 5455.31 | Sqm |
27 | 27 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nB) On fair side(both sides of brick wall)\nb) In cement mortar 1:4\n | item27 | 5423.18 | Sqm |
28 | 28 | "Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. \n"\n12.50 mm thick\n | item28 | 4249.39 | sqm |
29 | 29 | "Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) \nTATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement"\n(iii) 0.50 mm thick\n | item29 | 1393.24 | Sqm |
30 | 30 | "Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete.\nTATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement"\n(iii) 0.50 mm thick\n | item30 | 45.8 | RM |
31 | 31 | Providing dressed wood work in post, walls,battens, post plate bressumers etc. includingsupplying and fixing with spikes, nails,bolt and nuts of 12mm dia(M.S) and required length etc.complete with kiricide oiling two coats to faces in contact with C.C or masonry (M.S flats, angle cleats and bolt and nuts required for flats,angle cleats wherever use shall be measured and paid separately) \n(a) With sal wood\n | item31 | 2.48 | Cum |
32 | 32 | Providing, fitting and fixing factory made wooden panelled doors with panel inserts of 75mm to 50mm width and 12mm to 20mm thickness,joined together with continous tongue and groove joints glued together with Movicol or other approved adhesive leaving a vertical groove of 7.5mm to 15mm between the inserts,the edges of panel inserts being feather tongue into styles and rails including providing three pairs of oxidised M.S butt hinges (100mm x75 mm x3.55mm) and furnishing with moulded timber beading of size 25mmx15mm around the panels complete as per drawing (moulded timber bead and all fittings except hinges to be paid separately) \na) With Teak wood / Sissu wood.\n(ii) 35 mm thick with panel inserts of 20mm thickness.\n | item32 | 39.69 | Sq.m. |
33 | 33 | Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. \na) Decorative type face panel and block board core.\n(b) 35mm thick\n | item33 | 60.8 | Sq.m. |
34 | 34 | Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.\nII Ornamental grill\n(c) Fixed to Brickwork/P.C.C/R.C.C. \n | item34 | 7234.39 | Kg |
35 | 35 | Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.\n(b)3 Track sliding window\n(iv) 5 mm clear glass\n | item35 | 152.55 | Sqm |
36 | 36 | (b)Fixed windows and ventilators\n(i)6mm clear glass\n | item36 | 136.83 | Sqm |
37 | 37 | Providing, fitting and fixing anodised aluminium partition walls of standard sections of approved brand, joints mitred and welded (manufactured to relevant I.S. specification) and providing and fitting angle cleat, rubber gasket, bolting device screws etc. at all levels.\n(i)Partly 6mm thick glass panes and 12mm prelaminated ply board\n | item37 | 675 | sqm |
38 | 38 | Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)\n(i) Thickness = 1.5 mm thick\n | item38 | 10878.1 | Sqm |
39 | 39 | Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.\n(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)\n | item39 | 10878.1 | Sqm |
40 | 40 | PAINTING ON WOOD AND WOOD WOOD BASED SURFACES \nApplying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. \n(b). With ready mixed paint , wood primer (white). \n | item40 | 191.69 | Sqm |
41 | 41 | Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.\n(i).Surfaces over 100mm in width or girth.\nb). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).\n | item41 | 191.69 | Sqm |
42 | 42 | Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.\na). With ready mixed "red-lead/ red oxide" primer.\n | item42 | 354 | Sqm |
43 | 43 | Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(i).Surfaces over 100mm in width or girth.\nb). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).\n | item43 | 354 | Sqm |
44 | 44 | Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )\nb) Tower bolts\ni) 300mm x 12mm\n | item44 | 82 | Each |
45 | 45 | c) Door handles\niii) 150mm\n | item45 | 82 | Each |
46 | 46 | m) Mortice lock vertical type\ni) 65mm( Godrej With handle(2 lever)\n | item46 | 41 | set |
47 | 47 | Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ).\na) Sliding door bolts\ni) 300mm x 16mm\n | item47 | 41 | Each |
48 | 48 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(i) TMT Corrosion resistant steel (CRS) reiforcement bar\n | item48 | 1439.14 | Qtl |
49 | 49 | Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. \na) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997\n | item49 | 487.63 | Qtl |
50 | 50 | Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint. | item50 | 14.4 | sq.m. |
51 | 51 | Providing, fitting and fixing Godrej SS 304 grade railing with pipes/glass for different staircase , cutous areas, balcony etc. with complete installation, acrylic finish etc.which is fitted with mild pipes and top pipes of good quality steel. Moreover depending with the requirement glass panels can also be fitted on specific railings. Good quality screws are provided for fixing up the railings.\nSS Railing Steel with Glass Balustrades Holders Sideways.\n | item51 | 1102.5 | kg |
52 | 52 | Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished. | item52 | 115.5 | Sqm |
53 | 53 | Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.\ni). 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm. | item53 | 154 | rm |
54 | 54 | Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.\n | item54 | 2625 | Sqm |
55 | 55 | Providing,Fixing, testing &Commissioning of Rain water Hervesting system for 1000 sq.feet roof area with 110 mm uPVC pipe of Class-3 conforming to IS:4985-200 (with uptodate amendment) with extra UV ray protection by Titanium Dioxide(TiO2) directing the Rainwater to Rainy filter/Pop-up raintap filter (Excluding Civil Works) | item55 | 2 | Each |
56 | 56 | Water storage tank ISI Marked, conforming to IS:12701/1996 (with uptodate amendment). (Excluding Civil Works) | item56 | 20000 | Ltr. |
57 | 57 | Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (5 KG) \nBRAND : FIRESTOP / FIREND / FIRE SHIELD | item57 | 20 | each |
58 | 58 | Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)\na) Parryware make\n(i) Universal Closet S Trap (Cat No.C0271) (Anglo Indian) (inclusive of seat cover)\n | item58 | 13 | Each |
59 | 59 | Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)\nA) Parryware make\n(i) Rios with Chorme Push Plate (Cat no.8174/ Cat. No.C813726)\n | item59 | 12 | Each |
60 | 60 | Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)\n\nTable Top Basin\n(A) Parryware Make\n(i) Vanice (Cat. No.C8411) (white/coloured)\n | item60 | 21 | Each |
61 | 61 | Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.\n(A) Parryware Make\n(a) White\n(i) New Magnum (Cat. No.C0575)\n | item61 | 12 | Each |
62 | 62 | Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.\n(i) Jaquar Make\n(a) Continental (Cat.No.ACN-1331N)\n | item62 | 20 | each |
63 | 63 | Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified.\n(i) Jaquar Make\n(a) Continental (Cat.No.ACN-1135N) (with glass bottle)\n | item63 | 20 | each |
64 | 64 | Providing, fitting and fixing CP towel rail complete as directed and specified.\n(a) Jaquar make \n(i) Continental 300mm for wash basin (Cat.No. ACN-1101N)\n | item64 | 12 | each |
65 | 65 | Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified.\n(a) Jaquar make \n(i) Continental towel ring square (Cat.No. ACN-1121)\n | item65 | 12 | each |
66 | 66 | Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified.\n(a) Jaquar make \n(i) Continental (Cat.No. ACN-1191N)\n | item66 | 12 | each |
67 | 67 | Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified.\n(a) Jaquar Make\n(i) 32mm (HT/FT) (Cat.No.ALD-705 / 709)\n | item67 | 21 | each |
68 | 68 | Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia.\n | item68 | 250 | each |
69 | 69 | (iv) 75mm dia. | item69 | 200 | each |
70 | 70 | Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia.\n | item70 | 85 | each |
71 | 71 | (iv) 75 mm dia. | item71 | 75 | each |
72 | 72 | Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\na) In exposed surfaces or in trenches. \n(ii) 110mm dia.\n | item72 | 75 | each |
73 | 73 | (iv) 75 mm dia. | item73 | 50 | each |
74 | 74 | Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia.\n | item74 | 75 | each |
75 | 75 | (iv) 75 mm dia. | item75 | 50 | each |
76 | 76 | Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia.\n | item76 | 100 | each |
77 | 77 | (iv) 75 mm dia. | item77 | 75 | each |
78 | 78 | Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(iv) 110 mm x 75mm\n | item78 | 100 | each |
79 | 79 | Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table. | item79 | 15 | Cum |
80 | 80 | Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified.\n(A) Exposed on walls\na) 50 mm dia (Medium)\ni) Using Tata make\n | item80 | 400 | RM |
81 | 81 | (B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure.\nd) 25 mm dia (Medium)\ni) Using Tata make\n | item81 | 450 | RM |
82 | 82 | Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) \nJaquare make \n(a)Continental /Clarion\n(i)Standard\n | item82 | 12 | Each |
83 | 83 | Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) \nI) Brass stop cock (heavy) of Sant make\n(i)15mm dia \n | item83 | 33 | Each |
84 | 84 | Supplying, fitting and fixing Chrome Plated (C.P.) basin mixer complete as directed. \nCrabtree Frattini make (For VIP use. Prior approval of Chief Engineer PWD (Bldg) must be taken before use)\na) Florence\ni)Central hole basin mixer without pop-up Cat No.21051 for wash basin \n | item84 | 21 | Each |
85 | 85 | Wiring for light/ fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete\n SP upto 3.00 metre length.\n | item85 | 134 | point |
86 | 86 | MP upto 6.00 metre length. | item86 | 250 | point |
87 | 87 | LP upto 10.00 metre length. | item87 | 350 | point |
88 | 88 | Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.\n SP upto 10.00 metre length.\n | item88 | 40 | point |
89 | 89 | MP upto 15.00 metre length. | item89 | 20 | point |
90 | 90 | LP upto 20.00 metre length. | item90 | 20 | point |
91 | 91 | Wiring for 5 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 2 mm thick 20 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) \n\n SP upto 10.00 metre length. | item91 | 12 | point |
92 | 92 | MP upto15.00 metre length. | item92 | 10 | point |
93 | 93 | LP upto 20.00 metre length. | item93 | 10 | point |
94 | 94 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.\nWith 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | item94 | 3050 | mtr |
95 | 95 | With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | item95 | 640 | mtr |
96 | 96 | With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | item96 | 400 | mtr |
97 | 97 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.\nWith 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | item97 | 280 | mtr |
98 | 98 | Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. | item98 | 32 | Each |
99 | 99 | Supplying including installation of socket outlet 6/10/16 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. | item99 | 80 | Each |
100 | 100 | Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. | item100 | 32 | Each |
101 | 101 | Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. | item101 | 814 | Each |
102 | 102 | Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.\n3 module | item102 | 30 | Each |
103 | 103 | 6 module | item103 | 32 | Each |
104 | 104 | 12 module | item104 | 36 | Each |
105 | 105 | Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.\n3 module | item105 | 30 | Each |
106 | 106 | 6 module | item106 | 32 | Each |
107 | 107 | 12 module | item107 | 36 | Each |
108 | 108 | Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. | item108 | 120 | Each |
109 | 109 | Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp | item109 | 18 | Each |
110 | 110 | Supplying,installation,testing and Commission of the following indoor Surface Mounted and Suspended Luminaires LED Luminaires complete with all accessories such as driver etc. and necessary connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department \nPhilips 15 W Astra Surface & wall mounted LED batten Model BN150W LED13S-6500 PSE OD GR or equivalent as approved by the Deptt. | item110 | 406 | Each |
111 | 111 | Supplying,installation,testing and Commission of the following LED lamp as directed by the department \nPhilips LED Tubes Model Essential LEDtube 600mm 10W840 T8 /Essential LEDtube 600mm 10W865 T8 /Essential LEDtube 600mm 10W865 T8 AP I or equivalent as approved by the Deptt. | item111 | 6 | Each |
112 | 112 | Philips LED bulbs non-dimmable 7 W or equivalent as approved by the Deptt. | item112 | 18 | Each |
113 | 113 | Supplying, installation, connection, testing and commissioning of the following surface/suspended twin LED luminaries complete with all accessories including driver in the ceiling/ wall by providing necessary mounting bracket etc, and necessary connection with 1.5 sq mm. PVC. insulated S.C. copper conductor as required and as directed by the department. \nPhilips 40 W model BN 208 C LED 40/ (DL/ CDL/ NW) L 1200 FR or equivalent as approved by the Deptt. (twin 1200mm) | item113 | 77 | Each |
114 | 114 | Supplying, installation, connection, testing and commissioning of the LED Bulkhead luminaries complete with all accessories on wall by providing necessary arrangement and connection with 1.5 sq mm. PVC. insulated S.C. copper conductor as required and as directed by the department. \nPhilips 10 W, model WT 202 W LED 6S CW PSU SI PC or equivalent as approved by the Deptt.. | item114 | 10 | Each |
115 | 115 | Supplying including installation with required bracket, connection cable, as approved by the Deptt. with 2x2.5 sqmm copper FR CABLE, testing and commissioning of the following street light/ FLOOD LIGHT on existing pole/ Structure including lamp, driver, ballast as required complete as directed and specified by the deptt.\nPhilips Flood lighting luminaire 210W with high power LED and unique flood optics to ensure uniform distribution Model BVP410 LED 210 CW HE NB FG S3 XT or equivalent as approved by the Deptt. | item115 | 8 | Each |
116 | 116 | Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete. | item116 | 4 | Each |
117 | 117 | Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required. | item117 | 4 | Each |
118 | 118 | Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete. | item118 | 80 | Mtr |
119 | 119 | Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)\nEnergy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make | item119 | 211 | Each |
120 | 120 | Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. \nPower Flow 225 mm sweep (ORIENT make) | item120 | 16 | Each |
121 | 121 | Supplying with installation testing and commissioning of Hi -- wall 5 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with copper pipe and electrical connection cable, as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department.\nMitsubishi make Heavy duty Hybrid AC Model SRK 71 HE - 2 HEATING + COOLING | item121 | 10 | Each |
122 | 122 | Supplying with fitting and fixing of Single Phase Modular Motor Starter switch of the following specification complete including making necessary connection as specified and directed by the deptt. \nOverload Relay Range 16 - 25 Amps in 3 Module | item122 | 10 | Each |
123 | 123 | Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUS make) \n 5.0 KVA Automatic Input 90-280 V Out put 200-240 V | item123 | 10 | Each |
124 | 124 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \nABB, Schneider MG, legrand, Hager make) \n12 way SPN double door | item124 | 2 | Each |
125 | 125 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \nABB, Schneider MG, legrand, Hager make)\n 4way TPN (4+12) double door | item125 | 7 | Each |
126 | 126 | Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series\n(Schneider MG, legrand, Hager make)\n6-32A | item126 | 110 | Each |
127 | 127 | Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n 100/300mA sensitivity 4P RCCB\n(ABB, Schneider MG, legrand, Hager make)\n40A | item127 | 2 | Each |
128 | 128 | Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n 100/300mA sensitivity 4P RCCB\n(ABB, Schneider MG, legrand, Hager make)\n63A | item128 | 5 | Each |
129 | 129 | Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n30mA sensitivity DP RCCB\n(ABB, Schneider MG, legrand, Hager make)\n40A | item129 | 2 | Each |
130 | 130 | Supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor/wall mounting compartmentalize panel board of size 1.35M X 1.20MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of Red Oxide metal primer and 2 coats of enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 250A 4pole MCCB or Switch Fuse Unit as incomer and provision for 6nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:\n1. 20mm X 3mm4 strip copper Bus-Bar 0.6 M length each \n2. Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 no\n3. Digital 3 Phase Ammeter Accuracy class 0.5 - 1 no\n4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no\n5. Voltmeter & Ammeter Selector Switch - 2 no\n6. 2 A Slide fuse unit - 3nos\n(Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately) | item130 | 1 | Each |
131 | 131 | Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved by the Deptt.),as specified and directed by the deptt.\n25 KA 415V 50 Hz 3P MCCB \n(Havells, HPL, Indo Asian make)\ni)63A | item131 | 7 | Each |
132 | 132 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)\n 3&1/2core A2XFY\n 95.00 Sq. mm.3 & 1/2 Core armoured U.G. cable | item132 | 150 | Mtr |
133 | 133 | Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)\n3&1/2core A2XWFY,A2XFY \n95.00 Sq.mm 3&1/2 Core U.G. cable in 65mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) | item133 | 50 | Mtr |
134 | 134 | Supplying including installation, testing and commissioning of Water Cooled Jackson Diesel Generator set coupled to suitable alternator of 415 V, AC, 3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF/Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the following Technical Specification.. (RANGE FROM 15 KVA TO 625 KV \nTECHNICAL DATA CJ125D5P\nGENERATOR SET SPECIFICATIONS 125/100\n3. No. of Phases. 3 phase.\n4. POWER FACTOR 0.8 LAG\nJACKSON ENGINE SPECIFICATION. \n1. make). Cummins\n2. Model. 6BTAA5.9G3\n3. No. of Cylinders. 6\n4. Aspiration. TURBO CHARGED AIR COOLED\n5. Cooling. Water Cooled.\n6. Governor. Mechanical\n7. Battery Capacity Rating. 12 Volt.\n8. FUEL CONSUMPTION LTR/HR @ 75% LOAD 20.8\nALTERNATOR SPECIFICATION. \n1. make). CGT (STAMFOR \n2. Voltage Regulation. +/- 1.0%\n3. Insulation. Class - H.\n4. Standard Enclosure. IP 23\n5. No. of Phases. 3 WITH AMF CONTROL PANEL | item134 | 1 | Each |
135 | 135 | Load security & meter security to be pad to APDCL authority. | item135 | 65 | KW |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy