West Bengal State Police Housing Corporation Limited has published Repair , Renovation And Up-Gradation Of 220 Nos . Ls Quarters In 7Th Bn . , Kalyanpur Under Assansol-Durgapur Police Commissionerate . ( 1St Call ) . Submission Date for this Tender is 18-02-2020. Building Repair Tenders in 7th Bn., Kalyanpur West Bengal. Bidders can get complete Tender details and download the document.
Name of Work: Repair, renovation and up-gradation of 220 nos. LS Quarters in 7th Bn., Kalyanpur under Assansol-Durgapur Police Commissionerate. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Civil works | BI01010001010000000000000515BI0100001112 | ||
2 | 2 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed Inside plaster | BI01010001010000000000000515BI0100001113 | 42625 | Sq.m |
3 | 3 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed outside plaster | BI01010001010000000000000515BI0100001114 | 13220 | Sq.m |
4 | 4 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. Ground floor | BI01010001010000000000000515BI0100001115 | 20.4 | Cu.M |
5 | 5 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. First Floor | BI01010001010000000000000515BI0100001116 | 20.35 | Cu.M |
6 | 6 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. Second Floor | BI01010001010000000000000515BI0100001117 | 20.18 | Cu.M |
7 | 7 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. Third Floor & mumpty | BI01010001010000000000000515BI0100001118 | 16.5 | Cu.M |
8 | 8 | Dismantling artificial stone flooring upto 50 mm.\nthick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. (a) In ground floor including roof. Ground floor | BI01010001010000000000000515BI0100001119 | 2114.53 | Sq.M |
9 | 9 | Dismantling artificial stone flooring upto 50 mm.\nthick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. (a) In ground floor including roof. First Floor | BI01010001010000000000000515BI0100001120 | 2110 | Sq.M |
10 | 10 | Dismantling artificial stone flooring upto 50 mm.\nthick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. (a) In ground floor including roof. Second Floor | BI01010001010000000000000515BI0100001121 | 2110 | Sq.M |
11 | 11 | Dismantling artificial stone flooring upto 50 mm.\nthick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. (a) In ground floor including roof. Third Floor & mumpty | BI01010001010000000000000515BI0100001122 | 1045 | Sq.M |
12 | 12 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof. Ground Floor | BI01010001010000000000000515BI0100001123 | 50 | Cu.M |
13 | 13 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof. 1st Floor | BI01010001010000000000000515BI0100001124 | 25 | Cu.M |
14 | 14 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof. 2nd Floor | BI01010001010000000000000515BI0100001125 | 25 | Cu.M |
15 | 15 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof. 3rd Floor | BI01010001010000000000000515BI0100001126 | 54 | Cu.M |
16 | 16 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof..a) upto 150 mm. thick Ground Floor | BI01010001010000000000000515BI0100001127 | 10 | Cu.M |
17 | 17 | Dismantling carefully terraced floor only (including floor finish if any) or lime terracing in\nground floor roof and removing rubbish as directed within a lead of 75 m.(a) In Ground Floor including roof. | BI01010001010000000000000515BI0100001128 | 461.25 | Cu.M |
18 | 18 | Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. | BI01010001010000000000000515BI0100001129 | 2400 | Sq.M |
19 | 19 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal /Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge | BI01010001010000000000000515BI0100001130 | 2810 | Cu.M |
20 | 20 | Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge). | BI01010001010000000000000515BI0100001131 | 985 | Sq.m |
21 | 21 | Scraping and removing greasy soot from walls or ceiling of kitchen or similar smoke affected rooms and preparing the surface. | BI01010001010000000000000515BI0100001132 | 1535 | Sq.m |
22 | 22 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge. | BI01010001010000000000000515BI0100001133 | 170 | Sq.M |
23 | 23 | Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] | BI01010001010000000000000515BI0100001134 | 170 | Sq.M |
24 | 24 | Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface). | BI01010001010000000000000515BI0100001135 | 170 | Sq.M |
25 | 25 | Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge. | BI01010001010000000000000515BI0100001136 | 4538 | Sq.M |
26 | 26 | (a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification | BI01010001010000000000000515BI0100001137 | 9400 | Sq.M |
27 | 27 | Uprooting and removing plants from the surface of walls parapet etc and making good damages. Repairing of damages to be paid separately. (b) Medium size plant of girth of exposed stem above 75 mm. but not exceeding 150 mm. lift upto 6 mtr. | BI01010001010000000000000515BI0100001138 | 120 | Each |
28 | 28 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works. a) 25mm to 30mm thick wooden shuttering as per decision and direction of E.I.C Ground floor | BI01010001010000000000000515BI0100001139 | 2090 | SqM |
29 | 29 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works. a) 25mm to 30mm thick wooden shuttering as per decision and direction of E.I.C First Floor | BI01010001010000000000000515BI0100001140 | 1606 | SqM |
30 | 30 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works. a) 25mm to 30mm thick wooden shuttering as per decision and direction of E.I.C Second Floor | BI01010001010000000000000515BI0100001141 | 1410.5 | SqM |
31 | 31 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works. a) 25mm to 30mm thick wooden shuttering as per decision and direction of E.I.C Third Floor and Mumpty Room | BI01010001010000000000000515BI0100001142 | 550 | SqM |
32 | 32 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. Ground floor | BI01010001010000000000000515BI0100001143 | 8.637 | M.T. |
33 | 33 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. First Floor | BI01010001010000000000000515BI0100001144 | 7.325 | M.T |
34 | 34 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. Second Floor | BI01010001010000000000000515BI0100001145 | 7.175 | M.T |
35 | 35 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. Third Floor and Mumpty Room | BI01010001010000000000000515BI0100001146 | 3.85 | M.T |
36 | 36 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur Varity Ground floor | BI01010001010000000000000515BI0100001147 | 60.6 | CuM. |
37 | 37 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur Varity First Floor | BI01010001010000000000000515BI0100001148 | 28.71 | CuM. |
38 | 38 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur Varity Second Floor | BI01010001010000000000000515BI0100001149 | 29.2 | CuM. |
39 | 39 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur Varity Third Floor and Mumpty Room | BI01010001010000000000000515BI0100001150 | 23.75 | CuM. |
40 | 40 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur variety | BI01010001010000000000000515BI0100001151 | 214.5 | cum. |
41 | 41 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur variety (1st floor) | BI01010001010000000000000515BI0100001152 | 123.75 | CuM. |
42 | 42 | Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cement including the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge.a) 20 mm thick | BI01010001010000000000000515BI0100001153 | 448 | Sq.m |
43 | 43 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and\nconsolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on\nmeasurement of finished quantity) | BI01010001010000000000000515BI0100001154 | 93.75 | Cu.M |
44 | 44 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur Varity | BI01010001010000000000000515BI0100001155 | 35.325 | CuM. |
45 | 45 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4). Ground floor | BI01010001010000000000000515BI0100001156 | 180 | SqM |
46 | 46 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4). First Floor | BI01010001010000000000000515BI0100001157 | 133.95 | SqM |
47 | 47 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4). Second Floor | BI01010001010000000000000515BI0100001158 | 136.875 | SqM |
48 | 48 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4). Third Floor | BI01010001010000000000000515BI0100001159 | 88 | SqM |
49 | 49 | Plaster (to wall, floor, ceiling etc.)with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chamfering etc. including throating, nosing and drip course where necessary.Ground floor With 1:4 cement mortar b) 10 mm thick plaster (inside) | BI01010001010000000000000515BI0100001160 | 4015 | SqM |
50 | 50 | Plaster (to wall, floor, ceiling etc.)with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chamfering etc. including throating, nosing and drip course where necessary.Ground floor With 6:1 cement mortar b) 15mm thick plaster (inside) | BI01010001010000000000000515BI0100001161 | 8025 | SqM |
51 | 51 | Plaster (to wall, floor, ceiling etc.)with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chamfering etc. including throating, nosing and drip course where necessary.Ground floorWith 6:1 cement mortar a) 20mm thick plaster (outside) | BI01010001010000000000000515BI0100001162 | 4165 | SqM |
52 | 52 | Plaster (to wall, floor, ceiling etc.)with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chamfering etc. including throating, nosing and drip course where necessary In first floor With 1:4 cement mortar b) 10 mm thick plaster (inside) | BI01010001010000000000000515BI0100001163 | 3795 | SqM |
53 | 53 | Plaster (to wall, floor, ceiling etc.)with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chamfering etc. including throating, nosing and drip course where necessary In first floor With 6:1 cement mortar b) 15mm thick plaster (inside) | BI01010001010000000000000515BI0100001164 | 8080 | SqM |
54 | 54 | Plaster (to wall, floor, ceiling etc.)with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chamfering etc. including throating, nosing and drip course where necessary In first floor With 6:1 cement mortar a) 20mm thick plaster (outside) | BI01010001010000000000000515BI0100001165 | 4165 | SqM |
55 | 55 | Plaster (to wall, floor, ceiling etc.)with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chamfering etc. including throating, nosing and drip course where necessary Second floor With 1:4 cement mortar b) 10 mm thick plaster (inside) | BI01010001010000000000000515BI0100001166 | 4345 | SqM |
56 | 56 | Plaster (to wall, floor, ceiling etc.)with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chamfering etc. including throating, nosing and drip course where necessary Second floor With 6:1 cement mortar b) 15mm thick plaster (inside) | BI01010001010000000000000515BI0100001167 | 8080 | SqM |
57 | 57 | Plaster (to wall, floor, ceiling etc.)with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chamfering etc. including throating, nosing and drip course where necessary Second floor With 6:1 cement mortar a) 20mm thick plaster (outside) | BI01010001010000000000000515BI0100001168 | 4885 | SqM |
58 | 58 | Plaster (to wall, floor, ceiling etc.)with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chamfering etc. including throating, nosing and drip course where necessary Third floor With 1:4 cement mortar b) 10 mm thick plaster (inside) | BI01010001010000000000000515BI0100001169 | 1485 | SqM |
59 | 59 | Plaster (to wall, floor, ceiling etc.)with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chamfering etc. including throating, nosing and drip course where necessary Third floor With 6:1 cement mortar b) 15mm thick plaster (inside) | BI01010001010000000000000515BI0100001170 | 2585 | SqM |
60 | 60 | Plaster (to wall, floor, ceiling etc.)with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface by chamfering etc. including throating, nosing and drip course where necessary Third floor With 6:1 cement mortar a) 20mm thick plaster (outside) | BI01010001010000000000000515BI0100001171 | 2750 | SqM |
61 | 61 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor /Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy\ngrout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied\nby the contor) (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (B) Light Colour Ground floor | BI01010001010000000000000515BI0100001172 | 1005 | SqM |
62 | 62 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor /Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy\ngrout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied\nby the contor) (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (B) Light ColourFirst Floor | BI01010001010000000000000515BI0100001173 | 1005 | SqM |
63 | 63 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor /Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy\ngrout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied\nby the contor) (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (B) Light Colour Second Floor | BI01010001010000000000000515BI0100001174 | 1005 | SqM |
64 | 64 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m. | BI01010001010000000000000515BI0100001175 | 4420 | Sq.M |
65 | 65 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats Ground Floor | BI01010001010000000000000515BI0100001176 | 12425 | SqM |
66 | 66 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats First Floor | BI01010001010000000000000515BI0100001177 | 12425 | SqM |
67 | 67 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats Second Floor | BI01010001010000000000000515BI0100001178 | 12975 | SqM |
68 | 68 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats Third Floor and Mumpty Room | BI01010001010000000000000515BI0100001179 | 4950 | SqM |
69 | 69 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats Ground Floor | BI01010001010000000000000515BI0100001180 | 4165 | SqM |
70 | 70 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two CoatsFirst Floor | BI01010001010000000000000515BI0100001181 | 4165 | SqM |
71 | 71 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats Second Floor | BI01010001010000000000000515BI0100001182 | 4885 | SqM |
72 | 72 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats Third Floor and Mumpty Room | BI01010001010000000000000515BI0100001183 | 2750 | SqM |
73 | 73 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Premium 100% Acrylic Emulsion Ground floor | BI01010001010000000000000515BI0100001184 | 4165 | SqM |
74 | 74 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Premium 100% Acrylic Emulsion First Floor | BI01010001010000000000000515BI0100001185 | 4165 | SqM |
75 | 75 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Premium 100% Acrylic Emulsion Second Floor | BI01010001010000000000000515BI0100001186 | 4735 | SqM |
76 | 76 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Premium 100% Acrylic Emulsion Third Floor and Mumpty Room | BI01010001010000000000000515BI0100001187 | 2750 | SqM |
77 | 77 | Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts), reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, | BI01010001010000000000000515BI0100001188 | 1847.5 | Sq.M |
78 | 78 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malayasian Ground floor | BI01010001010000000000000515BI0100001189 | 5.515 | Cu.M |
79 | 79 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malayasian First Floor | BI01010001010000000000000515BI0100001190 | 5.725 | Cu.M |
80 | 80 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malayasian Second Floor | BI01010001010000000000000515BI0100001191 | 5.805 | Cu.M |
81 | 81 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Malayasian Third Floor | BI01010001010000000000000515BI0100001192 | 1.65 | Cu.M |
82 | 82 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made) (iii) 35mm thick shutters with 19mm thick\npanel of size 30to 45 Cm..(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. Ground Floor | BI01010001010000000000000515BI0100001193 | 34.65 | Sq.M |
83 | 83 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made) (iii) 35mm thick shutters with 19mm thick\npanel of size 30to 45 Cm..(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. First Floor | BI01010001010000000000000515BI0100001194 | 27.5 | Sq.M |
84 | 84 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made) (iii) 35mm thick shutters with 19mm thick\npanel of size 30to 45 Cm..(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. Second Floor | BI01010001010000000000000515BI0100001195 | 27.5 | Sq.M |
85 | 85 | Supplying solid flush type doors of commercial quality (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: (a) 35mm thick shutters (single leaf) Ground floor | BI01010001010000000000000515BI0100001196 | 331.5 | SqM |
86 | 86 | Supplying solid flush type doors of commercial quality (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: (a) 35mm thick shutters (single leaf) First Floor | BI01010001010000000000000515BI0100001197 | 331.5 | SqM |
87 | 87 | Supplying solid flush type doors of commercial quality (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: (a) 35mm thick shutters (single leaf) Second floor | BI01010001010000000000000515BI0100001198 | 331.5 | SqM |
88 | 88 | Supplying solid flush type doors of commercial quality (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: (a) 35mm thick shutters (single leaf) Third Floor | BI01010001010000000000000515BI0100001199 | 110 | SqM |
89 | 89 | Styles and rails of wooden shutters fitted and fixed complete.(Payment to be made on area of new work only). In Ground Floor: (ii) 35mm Thick shutter.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak Ground floor | BI01010001010000000000000515BI0100001200 | 44 | Sq.m |
90 | 90 | Styles and rails of wooden shutters fitted and fixed complete.(Payment to be made on area of new work only). In Ground Floor: (ii) 35mm Thick shutter.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak First Floor | BI01010001010000000000000515BI0100001201 | 44 | Sq.m |
91 | 91 | Styles and rails of wooden shutters fitted and fixed complete.(Payment to be made on area of new work only). In Ground Floor: (ii) 35mm Thick shutter.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak Second Floor | BI01010001010000000000000515BI0100001202 | 44 | Sq.m |
92 | 92 | Fixed louver shutters of doors and windows as per design,including fitting & fixing same in position but excluding the cost of hinges and other fittings in (iii) 35mm thick shutters with 12mm thick valve. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. First Floor | BI01010001010000000000000515BI0100001203 | 10.55 | Sq.M |
93 | 93 | Fixed louver shutters of doors and windows as per design,including fitting & fixing same in position but excluding the cost of hinges and other fittings in (iii) 35mm thick shutters with 12mm thick valve. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. Second Floor | BI01010001010000000000000515BI0100001204 | 10.55 | Sq.M |
94 | 94 | Fixed louver shutters of doors and windows as per design,including fitting & fixing same in position but excluding the cost of hinges and other fittings in (iii) 35mm thick shutters with 12mm thick valve. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. Mumpty Room | BI01010001010000000000000515BI0100001205 | 10.55 | Sq.M |
95 | 95 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria..(i) 66mm x 90mm | BI01010001010000000000000515BI0100001206 | 1067 | Mtr. |
96 | 96 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.\nIn ground floor.(ii) 32 mm thick Ground floor | BI01010001010000000000000515BI0100001207 | 104.5 | Sq.M |
97 | 97 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.\nIn ground floor.(ii) 32 mm thick First Floor | BI01010001010000000000000515BI0100001208 | 104.5 | Sq.M |
98 | 98 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.\nIn ground floor.(ii) 32 mm thick Second Floor | BI01010001010000000000000515BI0100001209 | 121 | Sq.M |
99 | 99 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.\nIn ground floor.(ii) 32 mm thick Third Floor | BI01010001010000000000000515BI0100001210 | 66 | Sq.M |
100 | 100 | MS or WI Ornamental grill of approved design joint continiously welded with MS .,WI flats and bars of windows,railings etc.Grill weighing above 10 kg/sqm and upto 16 kg/sqmtr. Ground Floor | BI01010001010000000000000515BI0100001211 | 9.9 | Qntl. |
101 | 101 | MS or WI Ornamental grill of approved design joint continiously welded with MS .,WI flats and bars of windows,railings etc.Grill weighing above 10 kg/sqm and upto 16 kg/sqmtr. First Floor | BI01010001010000000000000515BI0100001212 | 10.5 | Qntl. |
102 | 102 | MS or WI Ornamental grill of approved design joint continiously welded with MS .,WI flats and bars of windows,railings etc.Grill weighing above 10 kg/sqm and upto 16 kg/sqmtr. Second Floor | BI01010001010000000000000515BI0100001213 | 9.9 | Qntl. |
103 | 103 | MS or WI Ornamental grill of approved design joint continiously welded with MS .,WI flats and bars of windows,railings etc.Grill weighing above 10 kg/sqm and upto 16 kg/sqmtr. Third floor | BI01010001010000000000000515BI0100001214 | 7.15 | Qntl. |
104 | 104 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket,\nhandle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] Ground Floor | BI01010001010000000000000515BI0100001215 | 27.5 | SqM |
105 | 105 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket,\nhandle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] First Floor | BI01010001010000000000000515BI0100001216 | 27.5 | SqM |
106 | 106 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket,\nhandle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] Second Floor | BI01010001010000000000000515BI0100001217 | 27.5 | SqM |
107 | 107 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket,\nhandle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] Third floor | BI01010001010000000000000515BI0100001218 | 27.5 | SqM |
108 | 108 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (i) 4 mm thick | BI01010001010000000000000515BI0100001219 | 1133 | SqM |
109 | 109 | (a) Fixed type steel windows as per IS sizes with horizontal glazing bars. Ground floor | BI01010001010000000000000515BI0100001220 | 32 | Sq.m |
110 | 110 | (a) Fixed type steel windows as per IS sizes with horizontal glazing bars. First Floor | BI01010001010000000000000515BI0100001221 | 32 | Sq.m |
111 | 111 | (a) Fixed type steel windows as per IS sizes with horizontal glazing bars. Second Floor | BI01010001010000000000000515BI0100001222 | 32 | Sq.m |
112 | 112 | (a) Fixed type steel windows as per IS sizes with horizontal glazing bars. Third floor | BI01010001010000000000000515BI0100001223 | 16.5 | Sq.m |
113 | 113 | Two point nose aluminium handle including fitting and fixing. | BI01010001010000000000000515BI0100001224 | 770 | Each |
114 | 114 | steel peg stay 300 mm long including fitting and fixing. | BI01010001010000000000000515BI0100001225 | 770 | Each |
115 | 115 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering | BI01010001010000000000000515BI0100001226 | 2145 | SqM |
116 | 116 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering | BI01010001010000000000000515BI0100001227 | 4433 | SqM |
117 | 117 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white) | BI01010001010000000000000515BI0100001228 | 4433 | SqM |
118 | 118 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On Metal Surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) | BI01010001010000000000000515BI0100001229 | 2145 | SqM |
119 | 119 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (a) 40mm X 6mm, 250mm Length | BI01010001010000000000000515BI0100001230 | 3560 | Each |
120 | 120 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 100mm X 50mm X 1.25mm | BI01010001010000000000000515BI0100001231 | 1905 | Each |
121 | 121 | i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. 250mm long | BI01010001010000000000000515BI0100001232 | 748 | Each |
122 | 122 | Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. 300 mm long X 10mm dia bolt. | BI01010001010000000000000515BI0100001233 | 924 | Each |
123 | 123 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal / Round rod). (v) 125 mm grip x 12 mm dia rod. | BI01010001010000000000000515BI0100001234 | 924 | Each |
124 | 124 | Supplying fitting approved type ventilator in position after cutting holes in walls setting in cement mortar mending damages to wall and plaster and two coats of paint of approved brand of any shade. Payment of mending good damages of wall & plaster and painting to be made separately.(b) R.C.C ventilator of 20 mm. thick,(ii) Above 0.10 sq.m. area | BI01010001010000000000000515BI0100001235 | 55 | Sq.m |
125 | 125 | Godrej Hydraulic door closer fitted and fixed complete.Medium Type | BI01010001010000000000000515BI0100001236 | 108 | Each |
126 | 126 | (ii) Door stopper (Anodised aluminium) | BI01010001010000000000000515BI0100001237 | 276 | Each |
127 | 127 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including\nsmooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).\nUsing grey cement (iii) 35 mm. thick Ground Floor | BI01010001010000000000000515BI0100001238 | 400 | SqM |
128 | 128 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including\nsmooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).\nUsing grey cement (iii) 35 mm. thick 1stFloor | BI01010001010000000000000515BI0100001239 | 400 | SqM |
129 | 129 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including\nsmooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).\nUsing grey cement (iii) 35 mm. thick 2nd Floor | BI01010001010000000000000515BI0100001240 | 400 | SqM |
130 | 130 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including\nsmooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).\nUsing grey cement (iii) 35 mm. thick 3rd Floor | BI01010001010000000000000515BI0100001241 | 400 | SqM |
131 | 131 | Supplying dividing strip fitted and fixed with cement mortar (1:3) in mosaic or patent stone floor, dado etc. complete as per direction of the Engineer-in-charge. (i) Glass - 3mm. Thick (c) 37 mm. wide strip | BI01010001010000000000000515BI0100001242 | 3000 | Mtr. |
132 | 132 | Supplying dividing strip fitted and fixed with cement mortar (1:3) in mosaic or patent stone floor, dado etc. complete as per direction of the Engineer-in-charge. (i) Glass - 3mm. Thick (c) 25 mm. wide strip | BI01010001010000000000000515BI0100001243 | 2000 | Mtr. |
133 | 133 | Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour,scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] Ground floor | BI01010001010000000000000515BI0100001244 | 176 | Sq.M |
134 | 134 | Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour,scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] First Floor | BI01010001010000000000000515BI0100001245 | 176 | Sq.M |
135 | 135 | Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour,scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] Second Floor | BI01010001010000000000000515BI0100001246 | 176 | Sq.M |
136 | 136 | Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour,scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] Third Floor & mumpty | BI01010001010000000000000515BI0100001247 | 82.5 | Sq.M |
137 | 137 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] Ground floor | BI01010001010000000000000515BI0100001248 | 220 | SqM |
138 | 138 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] First Floor | BI01010001010000000000000515BI0100001249 | 220 | SqM |
139 | 139 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] Second Floor | BI01010001010000000000000515BI0100001250 | 220 | SqM |
140 | 140 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] Third Floor & mumpty | BI01010001010000000000000515BI0100001251 | 110 | SqM |
141 | 141 | Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone. | BI01010001010000000000000515BI0100001252 | 2740 | Mtr. |
142 | 142 | Extra cost of labour for grinding Kota Stone Floor in treads and riser of Steps. | BI01010001010000000000000515BI0100001253 | 2770 | SqM |
143 | 143 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m(i) Coloured decorative Ground floor | BI01010001010000000000000515BI0100001254 | 1270.5 | SqM |
144 | 144 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m(i) Coloured decorative First Floor | BI01010001010000000000000515BI0100001255 | 1270.5 | SqM |
145 | 145 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m(i) Coloured decorative Second Floor | BI01010001010000000000000515BI0100001256 | 1270.5 | SqM |
146 | 146 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m(i) Coloured decorative Third Floor | BI01010001010000000000000515BI0100001257 | 1122 | SqM |
147 | 147 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Wall With Sand Cement Mortar (1:3) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative Ground floor | BI01010001010000000000000515BI0100001258 | 1252.5 | SqM |
148 | 148 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Wall With Sand Cement Mortar (1:3) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative First Floor | BI01010001010000000000000515BI0100001259 | 1252.5 | SqM |
149 | 149 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Wall With Sand Cement Mortar (1:3) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative Second Floor | BI01010001010000000000000515BI0100001260 | 1252.5 | SqM |
150 | 150 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Wall With Sand Cement Mortar (1:3) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative Third Floor | BI01010001010000000000000515BI0100001261 | 495 | SqM |
151 | 151 | Construction of Plinth Protection with drain | BI01010001010000000000000515BI0100001262 | 1500 | Mtr. |
152 | 152 | Removing corroded worn out portion of reinforcement (when the area of bar is damaged by more than 25%) by cutting and replacing the same by a new plain round bar of requisite diameter by binding with required lap / welding\nwith old bar, including cost of reinforcement, complete in all respect including removing unserviceable materials from site as per direction of the Engineer - in - charge. Note : Payment on weight (Kg.) of new reinforcement. | BI01010001010000000000000515BI0100001263 | 799 | KG |
153 | 153 | Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-in-charge. (This item should be executed only after prior approval of the Engineer-in-charge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly. a) 3.90 metre height | BI01010001010000000000000515BI0100001264 | 35 | Each |
154 | 154 | Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-in-charge. (This item should be executed only after prior approval of the Engineer-in-charge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly. \nExtra for additional 3.6 height or part thereof | BI01010001010000000000000515BI0100001265 | 84 | Each |
155 | 155 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. | BI01010001010000000000000515BI0100001266 | 69.5 | Sq.m |
156 | 156 | For paver block road \n Earthwork in excavation in all sorts of soil trimming and dressing sides of pits, levelling, dressing and ramming the bottom as required complete as per drawing and direction including removing upto 75 metres, spreading or stacking the spoils at work site as directed. Rate should also include all work to prevent entry of water to excavated area and for bailing out of subsoil water, rain water, damaged sewer, water mains etc. as per direction during excavation of earth and concreting work in progress. a) Depth of excavation not exceeding 1.5 M. | BI01010001010000000000000515BI0100001267 | 431.5 | CuM |
157 | 157 | Brick work with 1st class bricks in cement mortar (1:6). (a) In foundation and plinth | BI01010001010000000000000515BI0100001268 | 127.5 | CuM |
158 | 158 | Brick work with 1st class bricks in cement mortar (1:6). (b) In superstructure, ground floor | BI01010001010000000000000515BI0100001269 | 101 | CuM |
159 | 159 | Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all\nrespect with all labour and material. [Border concrete if necessary to be paid separately].(c) 60 mm thick interlocking designer concrete paver block M- 35 grade for light-traffic zone, commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course &\n250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.) Coloured Decorative | BI01010001010000000000000515BI0100001270 | 1050 | Sq.M |
160 | 160 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size)including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone\nchips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour andmaterials.\nWith 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (SAIL/TATA/RINL) | BI01010001010000000000000515BI0100001271 | 6 | Each |
161 | 161 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation\nearth in all sorts of soil, shoring, bailing out and pumping out water as necessary, rammin, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevantI.S.Code. (iv) For 50 users\nA) With Pakur variety. (SAIL/TATA/RINL | BI01010001010000000000000515BI0100001272 | 2 | Each |
162 | 162 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fitting (tested to 21 kg per sq. cm.).(vi) 40 mm dia | BI01010001010000000000000515BI0100001273 | 100 | Each |
163 | 163 | d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). | BI01010001010000000000000515BI0100001274 | 550 | Each |
164 | 164 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made (a) For Exposed Work -- PVC Pipes 40mm | BI01010001010000000000000515BI0100001275 | 750 | Mtr |
165 | 165 | Dismantling H.C.I. pipe with fittings including melting lead caulked joints. (iii) 100 mm | BI01010001010000000000000515BI0100001276 | 4483.5 | Mtr |
166 | 166 | Dismantling wash basin with brackets with or without waste fittings | BI01010001010000000000000515BI0100001277 | 154 | Each |
167 | 167 | Dismantling sink with brackets with or without waste fittings (i) Upto 450 mm length | BI01010001010000000000000515BI0100001278 | 154 | Each |
168 | 168 | Dismantling Indian W.C. including taking out base concrete as necessary. | BI01010001010000000000000515BI0100001279 | 154 | Each |
169 | 169 | Dismantling Orissa pattern W.C. including taking out of base concrete, if necessary, complete. | BI01010001010000000000000515BI0100001280 | 154 | Each |
170 | 170 | Dismantling flush pipe of water closet. | BI01010001010000000000000515BI0100001281 | 154 | Each |
171 | 171 | Labour for dismantling G.I. pipe with fittings. (i) 15 mm | BI01010001010000000000000515BI0100001282 | 2220 | Mtr |
172 | 172 | Labour for dismantling G.I. pipe with fittings. (iii) 25 mm | BI01010001010000000000000515BI0100001283 | 1355 | Mtr |
173 | 173 | Labour for dismantling G.I. pipe with fittings. (vi) 50 mm | BI01010001010000000000000515BI0100001284 | 1355 | Mtr |
174 | 174 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made (a) For Exposed Work -- PVC Pipes 25 mm | BI01010001010000000000000515BI0100001285 | 2293 | Mtr. |
175 | 175 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made (a) For Exposed Work -- PVC Pipes 32mm | BI01010001010000000000000515BI0100001286 | 1925 | Mtr |
176 | 176 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made (a) For Exposed Work -- PVC Pipes (Dia) 50 mm | BI01010001010000000000000515BI0100001287 | 600 | Mtr. |
177 | 177 | Supplying, fitting and fixing CPVC (Chlorinated\nPolyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost\nof all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including\nall specials. No separate payment will be made for accesories, specials.(a) For Concealed work 15 mm | BI01010001010000000000000515BI0100001288 | 1845 | Mtr. |
178 | 178 | Supplying, fitting and fixing CPVC (Chlorinated\nPolyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost\nof all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including\nall specials. No separate payment will be made for accesories, specials.(a) For Concealed work 20 mm | BI01010001010000000000000515BI0100001289 | 2660 | Mtr. |
179 | 179 | Supplying, fitting and fixing CPVC (Chlorinated\nPolyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost\nof all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including\nall specials. No separate payment will be made for accesories, specials.(a) For Concealed work 25 mm | BI01010001010000000000000515BI0100001290 | 1795 | Mtr. |
180 | 180 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Mtr. Length a) 160 mm | BI01010001010000000000000515BI0100001291 | 3070 | Mtr. |
181 | 181 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Mtr. Length b)110 mm | BI01010001010000000000000515BI0100001292 | 2200 | Mtr. |
182 | 182 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (i) Door Tee (160 mm) | BI01010001010000000000000515BI0100001293 | 275 | Each |
183 | 183 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (i) Door Tee (110 mm) | BI01010001010000000000000515BI0100001294 | 770 | Each |
184 | 184 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (ii)Bend 87.5 dig. (160 mm) | BI01010001010000000000000515BI0100001295 | 275 | Each |
185 | 185 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (iii)Bend 87.5 dig. (110 mm) | BI01010001010000000000000515BI0100001296 | 440 | Each |
186 | 186 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (iii) Door Bend 160 mm | BI01010001010000000000000515BI0100001297 | 330 | Each |
187 | 187 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (iv) Vent Cowl 160 mm | BI01010001010000000000000515BI0100001298 | 84 | Each |
188 | 188 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (iv) Vent Cowl 110 mm | BI01010001010000000000000515BI0100001299 | 198 | Each |
189 | 189 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (ii) Plain Tee (b) 110 mm | BI01010001010000000000000515BI0100001300 | 703 | Each |
190 | 190 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (ii) Plain Tee (c) 160 mm | BI01010001010000000000000515BI0100001301 | 495 | Each |
191 | 191 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 (v) Plain Y (b) 110 mm | BI01010001010000000000000515BI0100001302 | 420 | Each |
192 | 192 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992 Bend 45 Dig. (b) 110 mm | BI01010001010000000000000515BI0100001303 | 915 | Each |
193 | 193 | Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials) (A) Above ground (i) 160 mm | BI01010001010000000000000515BI0100001304 | 1050 | Mtr. |
194 | 194 | Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials) (A) Above ground (ii) 110 mm | BI01010001010000000000000515BI0100001305 | 1980 | Mtr. |
195 | 195 | Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials) (B) Under ground (i) 160 mm | BI01010001010000000000000515BI0100001306 | 2020 | Mtr. |
196 | 196 | Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials) under ground (ii) 110 mm | BI01010001010000000000000515BI0100001307 | 220 | Mtr. |
197 | 197 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm | BI01010001010000000000000515BI0100001308 | 220 | Each |
198 | 198 | Supplying, fitting and fixing towel rail with two brackets. (a) (ii) C.P. over brass 25 mm dia. and 600 mm long | BI01010001010000000000000515BI0100001309 | 220 | Each |
199 | 199 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap | BI01010001010000000000000515BI0100001310 | 220 | Each |
200 | 200 | Supplying, fitting and fixing shower of approved brand and make (a) (i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model -\nTropical / Sumthing Special of ESSCO or similar brand). | BI01010001010000000000000515BI0100001311 | 220 | Each |
201 | 201 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.White | BI01010001010000000000000515BI0100001312 | 220 | Each |
202 | 202 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete.\n(a) E.W.C. (ii) Plastic (hallow type) white | BI01010001010000000000000515BI0100001313 | 220 | Each |
203 | 203 | Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(ii) 450 mm long | BI01010001010000000000000515BI0100001314 | 220 | Each |
204 | 204 | Supplying, fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with coupling at one end fitted with necessary clamps. 1050 mm long | BI01010001010000000000000515BI0100001315 | 220 | Each |
205 | 205 | Supplying, fitting and fixing vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 32 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size | BI01010001010000000000000515BI0100001316 | 220 | Each |
206 | 206 | Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets.\n(i) 530 mm X 430 mm x 180 mm | BI01010001010000000000000515BI0100001317 | 220 | Each |
207 | 207 | Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground\nFloor. (a) Slab Thickness 20 to 25 mm Ground floor | BI01010001010000000000000515BI0100001318 | 111.7 | Sq.m |
208 | 208 | Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground\nFloor. (a) Slab Thickness 20 to 25 mm First Floor | BI01010001010000000000000515BI0100001319 | 111.7 | Sq.m |
209 | 209 | Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground\nFloor. (a) Slab Thickness 20 to 25 mm Second Floor | BI01010001010000000000000515BI0100001320 | 111.7 | Sq.m |
210 | 210 | Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground\nFloor. (a) Slab Thickness 20 to 25 mm Third Floor | BI01010001010000000000000515BI0100001321 | 38.5 | Sq.m |
211 | 211 | Supplying ,fitting and fixing bib cock or stop cock (b) (ii) Chromium plated Concealed Stop Cock (Equivalent to Code No. 514(A) & Model - Tropical / Sumthing Special of ESSCO or similar). | BI01010001010000000000000515BI0100001322 | 220 | Each |
212 | 212 | (c) (i) Chromium plated Bib Cock (angular shape with wall flange) (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar). | BI01010001010000000000000515BI0100001323 | 660 | Each |
213 | 213 | (b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar | BI01010001010000000000000515BI0100001324 | 110 | Each |
214 | 214 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity | BI01010001010000000000000515BI0100001325 | 44 | Each |
215 | 215 | Labour for hoisting plastic water storage tank.(ii) Above 1500 litre upto 5000 litre capacity. | BI01010001010000000000000515BI0100001326 | 22 | Each |
216 | 216 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fitting (tested to 21 kg per sq. cm.).(iv) 50 mm dia | BI01010001010000000000000515BI0100001327 | 80 | Each |
217 | 217 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fitting (tested to 21 kg per sq. cm.).(vi) 32 mm dia | BI01010001010000000000000515BI0100001328 | 170 | Each |
218 | 218 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fitting (tested to 21 kg per sq. cm.).(vii) 25 mm dia | BI01010001010000000000000515BI0100001329 | 176 | Each |
219 | 219 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete\n(1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary\nreinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.i) With Pakur variety. | BI01010001010000000000000515BI0100001330 | 74 | Each |
220 | 220 | Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed.(c) Upto 50 users:-(ii) Beyond a lead of 150 metre and outside the Municipal limit | BI01010001010000000000000515BI0100001331 | 20 | Each |
221 | 221 | Cleaning soak pit by removing the top slab and replacing inner filling with jhama bats and repairing the pit as necessary including fitting the slab. | BI01010001010000000000000515BI0100001332 | 18 | Each |
222 | 222 | ELECTRICAL SCHEDULE ITEM\nSupply & fixing 415 volt 63 A TPN switch in S.S. enclosure with HRC fuses onLS & NL to be fixed on angle frame on wall including earthing attachment.(LT/Seimens)(PS) | BI01010001010000000000000515BI0100001333 | 22 | set |
223 | 223 | Supplying & fixing 415V,100A,sheet metal (16 SWG) Iron Clad Busbar chambers having dimension of 500x150mm having 4 no of cu bar of each 4x15x3mm on angle iron frame on wall, incl. earthing attachment and painting as required.\n | BI01010001010000000000000515BI0100001334 | 22 | mtr |
224 | 224 | Connecting & dressing Meter looping system with 2 x 6 + 1 x 4 sq mm PVC insulated copper wire duly layed on the Ply board by 25 MM dia PVC rigid conduict from Bus Bar to Meters & Meters to DP MCBs (Ave 3 meters) | BI01010001010000000000000515BI0100001335 | 660 | mtr |
225 | 225 | Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through 19 mm alkathene pipe recessed in wall.\n2x6+1x4 sqmm (SPNDB) | BI01010001010000000000000515BI0100001336 | 4400 | mtr |
226 | 226 | Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through 19 mm alkathene pipe recessed in wall.\n2x2.5+1x1.5 sqmm (P/P Plug & Computer Plug) | BI01010001010000000000000515BI0100001337 | 6600 | mtr |
227 | 227 | CSupply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through 19 mm alkathene pipe recessed in wall. 3x1.5 sqmm (roof light & Compound Light) | BI01010001010000000000000515BI0100001338 | 2420 | mtr |
228 | 228 | Finishing of the 2x6+1x4 PVC insulated wire ends by socketing with pin/ring type copper sockets and insulated tapes etc. including supplying sockets and tapes. | BI01010001010000000000000515BI0100001339 | 924 | set |
229 | 229 | Supply & fixing of 240V 25 A DP MCB (Legrand) in DP SS enclosure (Legrand) incl earthing attachment. | BI01010001010000000000000515BI0100001340 | 99 | set |
230 | 230 | Supply & fixing of 240V 32 A DP MCB (Legrand) in DP SS enclosure (Legrand) incl earthing attachment. | BI01010001010000000000000515BI0100001341 | 78 | set |
231 | 231 | Supply & fixing of 240V 40 A DP MCB (Legrand) in DP SS enclosure (Legrand) incl earthing attachment. | BI01010001010000000000000515BI0100001342 | 65 | set |
232 | 232 | Supply & Fixing (2+8 ) way SPN MCBDB with IP-42/43 protection Concealed in wall & mending good the damages to original finish incl. Interconnection with suitable copper wire & nuetral link incl. earthing attachment comprising with the following (Legrand/Seimens)\na) 40 A DP MCB isolator & necy. connection --- 1 no\nb) 6 to 25A SP MCB as required breaking capacity \n 10KA & C characteristic ---- 8 nos | BI01010001010000000000000515BI0100001343 | 220 | set |
233 | 233 | Distn. wiring in 3X22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick poly pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2\nno. suitable size “Ph & N” copper bar flushed in wall incl. mending good damages to original finish (ave run 6 mtr) | BI01010001010000000000000515BI0100001344 | 2240 | Pts |
234 | 234 | Distn. wiring in 3X22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2\nno. suitable size “Ph & N” copper bar flushed in wall incl. mending good damages to original finish (ave run 8 mtr) | BI01010001010000000000000515BI0100001345 | 840 | Pts |
235 | 235 | Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded 'FR' PVC insulated & unsheathed copper wire (brand approved by EIC) in 19mm bore, 3mm thickpolythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pin modular type plug socket & modular type switch(Brand appr. by EIC) incl. S&F earth continuity wire fixed on 4 module GI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. (on board) | BI01010001010000000000000515BI0100001346 | 660 | Pts |
236 | 236 | Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded 'FR' PVC insulated & unsheathed copper wire (brand approved by EIC) in 19mm bore, 3mm thickpolythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pin modular type plug socket & modular type switch(Brand appr. by EIC) incl. S&F earth continuity wire fixed on 4 module GI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. (Ave run 3 mtr) | BI01010001010000000000000515BI0100001347 | 616 | Pts |
237 | 237 | Supply & fixing of Modular type computer plug board of 8module GI box with cover plate recessed in wall comprising of the following(All cabtree):\na) 16A socket &switch ---1 set \nb) 6A socket & switch --- 2 sets | BI01010001010000000000000515BI0100001348 | 220 | set |
238 | 238 | Supply & fixing of Modular type 16A 3 pin modular type plug socket (Brand approved by EIC) with 16 A Modular type switch without plug top on of 4 module GI box with cover plate recessed in wall comprising of the following (All cabtree): a) 16A switch ---1 set \nb)16A socket - 1 set | BI01010001010000000000000515BI0100001349 | 440 | set |
239 | 239 | Fixing only singal / twin fluorescent light complete with all accessories directly on wall/ceilinh/HW round block and suitable size of MS fastener,etc. as required. | BI01010001010000000000000515BI0100001350 | 154 | set |
240 | 240 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. | BI01010001010000000000000515BI0100001351 | 660 | each |
241 | 241 | S & F earth busbar of galvanized (Hot Dip) MS flat 25mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required | BI01010001010000000000000515BI0100001352 | 11 | mtr |
242 | 242 | Supply & Fixing 240 V, 16 A,Modular type switch, on 2 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. | BI01010001010000000000000515BI0100001353 | 20 | each |
243 | 243 | Fixing only outdoor / street light type light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting. | BI01010001010000000000000515BI0100001354 | 99 | each |
244 | 244 | S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) | BI01010001010000000000000515BI0100001355 | 110 | each |
245 | 245 | Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works | BI01010001010000000000000515BI0100001356 | 1870 | mtr |
246 | 246 | Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work | BI01010001010000000000000515BI0100001357 | 792 | mtr |
247 | 247 | Making soldered joints between conductor/ down pipes / other metallic objects by 7/10 stranded GI (Hot Dip) wire incl. supply of jointing materials & painting with 2 (two) coats of Bituminous paint. | BI01010001010000000000000515BI0100001358 | 264 | mtr |
248 | 248 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. | BI01010001010000000000000515BI0100001359 | 308 | mtr |
249 | 249 | Earthing the installation by 50 mm dia. G.I. Pipe (ISI-M) of 3.64 mtr. Long driven to an depth of 3.65 mtr. Below the ground level including S/F 1X4 SWG. G.I. Earth wire (4 mtr. Long) with nuts bolts & washers. | BI01010001010000000000000515BI0100001360 | 88 | set |
250 | 250 | Extra for providing masonary on the top of the earth electrode of overall size ( 86.36 cm x 86.36 cm. x 46 mm depth) below GL, Complete with cemented brick work 1:6 of 25 cm. width duly plastered with cement morter inside CI locking arrangement, GI reducer incl. drilling of 46 nos. 12 mm dia holes on GI Pipe. | BI01010001010000000000000515BI0100001361 | 88 | Item |
251 | 251 | ELECTRICAL NON-SCHEDULE ITEM\nSupply & fixing 12mm thick water & vermin proof super quality ply wood of size (6' ft x 4' ft) to be fixed on wall with suitable long screws fastener etc after painting the rear side with black japan paint.(pwd civil page no 173 item no 2(iv )Rs1709/sqmtr,with GST 1914/ sq mtr | BI01010001010000000000000515BI0100001362 | 49.06 | sq mtr |
252 | 252 | Supply 4' single LED type tube light fitting complete with all acessaries directly on ceiling with HW round block & suitable size of MS fastener (Crompton, cat no - DIJB12LT8-20, LLT8-8 | BI01010001010000000000000515BI0100001363 | 154 | set |
253 | 253 | Supply of 45 W LED light fitting (make Crompton, cat no - LSTS-45-CDL/Havells/Nordusk cat no KN-STL-FM -45W) | BI01010001010000000000000515BI0100001364 | 99 | set |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy