Construction Of Substation Building At Chora 7/9 Colliery Under Kenda Area . , CHORA 7,9 PIT KENDA AREA-West Bengal

Eastern Coal Fields Ltd-ECL has published Construction Of Substation Building At Chora 7/9 Colliery Under Kenda Area . . Submission Date for this Tender is 03-02-2020. Substation Tenders in CHORA 7,9 PIT KENDA AREA West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

23367292
Construction Of Substation Building At Chora 7/9 Colliery Under Kenda Area .
Open Tender
Indian
West Bengal
CHORA 7,9 PIT KENDA AREA
03-02-2020

Tender Details

Construction Of Substation Building At Chora 7/9 Colliery Under Kenda Area .

Key Value

Document Fees
Refer document
EMD
INR 34600.0 /-
Tender Value
INR 27.60 Lakhs /-

BOQ Items

Name of Work:
Sl. No. Item Description Item Code / Make Quantity Units
1 1.01 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m - All kinds of soil. BI01010001010000000000000515BI0100001113 141.882 cum
2 1.02 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. BI01010001010000000000000515BI0100001114 144.944 cum
3 1.03 Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (Payment to be made on measurement of finished quantity) BI01010001010000000000000515BI0100001115 16.588 cum
4 1.04 Single Brick soling with picked jhama bricks including preparation of bed as necessary with brick joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling BI01010001010000000000000515BI0100001116 328.118 sqm
5 1.05 P/L P.C.C. excluding the cost of centering and shuttering - All work up to plinth level - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001117 14.349 cum
6 1.06 Brick work with common burnt clay F.P.S. bricks of class designation 7.5 in foundation and plinth in- Cement mortar 1:6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001118 34.021 cum
7 1.07 Brick work with common burnt clay F.P.S. bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001119 75.349 cum
8 1.08 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level- Cement mortar 1:4 (1 cement :4 coarse sand) BI01010001010000000000000515BI0100001120 66.166 sqm
9 1.09 Providing and laying in position specified grade of RCC, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001121 27.477 cum
10 1.1 RCC work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001122 7.83 cum
11 1.11 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). BI01010001010000000000000515BI0100001123 45.533 cum
12 1.12 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001124 39.15 sqm
13 1.13 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers BI01010001010000000000000515BI0100001125 205.402 sqm
14 1.14 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform BI01010001010000000000000515BI0100001126 246.872 sqm
15 1.15 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts BI01010001010000000000000515BI0100001127 165.88 sqm
16 1.16 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level : Thermo-Mechanically Treated bars BI01010001010000000000000515BI0100001128 7275.6 kg
17 1.17 CEMENT PLASTER (IN FINE SAND) 12mm thick cement plaster of mix 1:6 (1 cement: 6 fine sand) BI01010001010000000000000515BI0100001129 573.9 sqm
18 1.18 6mm thick cement plaster in ceiling 1:3 (1 cement : 3 fine sand) BI01010001010000000000000515BI0100001130 257.792 sqm
19 1.19 CEMENT PLASTER (IN COARSE SAND) 12 mm cement plaster of mix - 1:6 (1 cement: 6 coarse sand) BI01010001010000000000000515BI0100001131 393.282 sqm
20 1.2 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer- Using flats 30x6mm for diagonal braces and central cross piece BI01010001010000000000000515BI0100001132 110.7 sqm
21 1.21 P/F M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete : Fixed to steel windows by welding BI01010001010000000000000515BI0100001133 494.64 kg
22 1.22 40 mm thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with Net Cement Punning BI01010001010000000000000515BI0100001134 194.28 sqm
23 1.23 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. BI01010001010000000000000515BI0100001135 52.5 sqm
24 1.24 Colour washing to give an even shade :New work (two or more coats) with a base coat of whiting BI01010001010000000000000515BI0100001136 831.692 sqm
25 1.25 Finishing walls with Acrylic Smooth exterior paint of required shade- New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) BI01010001010000000000000515BI0100001137 393.282 sqm
26 1.26 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade- One or more coats on old work BI01010001010000000000000515BI0100001138 265.68 sqm
27 1.27 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. BI01010001010000000000000515BI0100001139 120 kg
28 1.28 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group A BI01010001010000000000000515BI0100001140 26 Point
29 1.29 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire BI01010001010000000000000515BI0100001141 260 Metre
30 1.3 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps BI01010001010000000000000515BI0100001142 4 Each
31 2 Total impact of GST for the purpose of CTC BI01010001010000000000000515BI0100001177 1 Nos