Nctps I Es Circle C I Dn S Dn Iv Fsss Carrying Out Maintenance Activities Of Fsss Sadc Equipments Boiler Mill Plant Allied Areas Of Unit 3 For A Period Of 180 Days, NCTPS I-Tamil Nadu

Tamil Nadu Generation And Distribution Corporation Limited-TANGEDCO has published Nctps I Es Circle C I Dn S Dn Iv Fsss Carrying Out Maintenance Activities Of Fsss Sadc Equipments Boiler Mill Plant Allied Areas Of Unit 3 For A Period Of 180 Days. Submission Date for this Tender is 06-02-2020. Boiler Work Tenders in NCTPS I Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

23356591
Nctps I Es Circle C I Dn S Dn Iv Fsss Carrying Out Maintenance Activities Of Fsss Sadc Equipments Boiler Mill Plant Allied Areas Of Unit 3 For A Period Of 180 Days
Open Tender
Indian
Tamil Nadu
NCTPS I
06-02-2020

Tender Details

Nctps I Es Circle C I Dn S Dn Iv Fsss Carrying Out Maintenance Activities Of Fsss Sadc Equipments Boiler Mill Plant Allied Areas Of Unit 3 For A Period Of 180 Days

Key Value

Document Fees
Refer document
EMD
INR 3900.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: NCTPS-I – ES Circle – C&I Dn. – S.Dn. IV (FSSS) – Carrying out Maintenance activities of FSSS, SADC Equipments,boiler & mill plant allied areas of UNIT-3 for a period of 180 days
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Charges for removal of local pressure/ temperature gauges and refixing them after calibration in boiler, turbine and Generator areas. BI01010001010000000000000515BI0100001112 40 Nos
2 2 Charges for removal of pressure/ temperature/Vacuum/ Flow switches and re fixing them after calibration in boiler, turbine and Generator areas. BI01010001010000000000000515BI0100001113 38 Nos
3 3 Charges for removal of pressure/ temperature Transmitters including disconnecting the control cables, Removal of clamps & manifold and re fixing them after calibration in boiler, turbine and Generator areas. BI01010001010000000000000515BI0100001114 18 Nos
4 4 Charges for removing from field, Transporting to the lab, cleaning, handing over to the lab for calibration and re fixing after calibration of Air Regulator with Gauges. BI01010001010000000000000515BI0100001115 40 Nos
5 5 Charges for removing from field, Transporting to the lab, cleaning, handing over to the lab for calibration and re fixing after calibration of I/P converter. BI01010001010000000000000515BI0100001116 24 Nos
6 6 Charges for removing and refitting of accessories in pneumatic control valves & dampers such as I/P converters, air lock relay, air regulators, positioners and position feedback transmitters sending to lab for testing, and receiving the tested instruments from lab . BI01010001010000000000000515BI0100001117 38 Nos
7 7 Fixing the keltron pneumatic actuator in the new bed bolt assembly and refixing the accessories such as Air regulator, I/P converter with SS tubings and making alignment for the same. 16 Nos
8 8 Charges for releasing of Electronic cards from the racks, cleaning of panels & reinserting the cards, terminal tightness checking of FSSS, SADC, PRDS, Feeder, HYDRASTEP, 110 V AC & 220 V DC distribution panels and CHARGER Panels. 40 Panels
9 9 Removing the solenoids, air regulators and SS tubes for fixing field enclosure in APH soot blowing valve. 16 Nos.
10 10 Disconnecting the connectors of the flame scanners, removing from the Boiler guide pipe assembly, transporting to work bench, dismantling & Reassembling the scanner head assembly from scanners, removing, cleaning & re fixing the lenses, servicing and checking of flame scanners. 20 Nos
11 11 Removing the cotter pins, disconnecting the air lines, removing the positioners from the boiler wall mountings, transporting to work bench, cleaning, replacing seal kits and bellows with new seal kits and new bellows, checking and re-fixing of SADC, Positioners. 44 Nos
12 12 Charges for removing, cleaning solenoid valves, air filter cum lubricator & the air lines and replacing the ‘O’ rings in the solenoid valves and re fixing the solenoid valves, air filter cum lubricator & the air lines in the HAGs. BI01010001010000000000000515BI0100001118 14 Nos
13 13 Removing the terminal connections, replacing the broken terminal blocks and reconnecting the terminal connections and checking in various junction boxes at boiler and mill area. BI01010001010000000000000515BI0100001119 32 Nos
14 14 Charges for rectification and welding of broken doors in junction boxes. BI01010001010000000000000515BI0100001120 10 Nos.
15 15 Replacement of defective ½” ss instruments valves in various location. BI01010001010000000000000515BI0100001121 20 Nos
16 16 Replacing of broken studs in hydrastep. BI01010001010000000000000515BI0100001122 10 Nos