Kolkata Municipal Corporation-KMC has published Beautification Of Lighting System At The Around Of 201A Nsc Bose Road Opposite Of Naktala Post Office In Ward No 100 Br-X .. Submission Date for this Tender is 03-02-2020. Decoration Work Tenders in NAKTALA POST OFFICE West Bengal. Bidders can get complete Tender details and download the document.
Name of Work:BEAUTI FICATION OF LIGHTING SYSTEM AT THE AROUND OF 201A NSC BOSE ROAD OPPOSITE OF NAKTALA POST OFFICE IN WARD NO 100 BR-X. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole CAP etc Supplying of Swaged Steel Tubular pole as per IS 2713, Pt. II, 1980 for following designation and of following dimensions.(Outside dia & thickness are given in Annexture -1) ii) 5.0 Mtr., 45 Kg. | item1 | 50 | EA |
2 | 2 | Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole CAP etc. Erection of Minipole of height 3.25 M to 5.0 M in C.C. foundation 460 mm x 460 mm x 900 mm depth of 1:2:4 cement concrete with stone metal including muffing of 300 mm x 300 mm x 300 mm painting the pole with 2 coats of Aluminium paint over a coat of red oxide. | item2 | 50 | EA |
3 | 3 | SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe. | item3 | 50 | SET |
4 | 4 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 13. Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. fixing only loop box if necessary (a) Without Loop Box | item4 | 50 | EA |
5 | 5 | Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole CAP etc.Supply & Fixing projected lamp bracket made 50mm dia G.I. Pipe (TATA Medium) of 1.85 Meter in length of which 0.9 Meter in projection having an angle of 105 degree with clamps, M.S. angles, bolts, nuts & clamps, etc. as required and as per direction of Engineer-In-Charge. | item5 | 50 | EA |
6 | 6 | Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole CAP etc. Painting steel tubular pole including projected arm bracket (Upto 1.5 Meter Bracket Length) with one coat of red oxide primer and two coats with Aluminium paint and numbering the pole with cellulose enamel paint in black back ground and white number etc. (Scraping where necessary). (excluding numbering) Upto 7.0 mtr. length and above 5 mtr. | item6 | 50 | EA |
7 | 7 | Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. | item7 | 50 | EA |
8 | 8 | Supplying and fixing Sheet steel Main Switches on angle iron frame on wall 415V TPN with fuse on L&N 100/125 A Havells | item8 | 2 | EA |
9 | 9 | Bus-Bar Chambers : Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required ... ( As per Drawing no. 470 of PWD Specification Book ... May 1991) Dimension 4 x 100x15mm ofAl. bars[85mm long) Rate / Mt.of completechamberDimension 500x150mm ofSheet MetalBox 415 V, 1000 A | item9 | 2 | EA |
10 | 10 | Supply and/or Fixing Item Supplying of 1.1 KV. Grade PVC insulated armored Aluminum Conductor of following cables( make: Polycab/ Gloster/Havells/Finolex): Size in Sq. mm 10 No & dia. Of wire in mm 1/3.55 No of Core 4 | item10 | 992 | RGM |
11 | 11 | Supply and/or Fixing Item Supplying of 1.1 KV. Grade PVC insulated armored Aluminum Conductor of following cables( make: Polycab/ Gloster/Havells/Finolex): Size in Sq. mm 25 No & dia. Of wire in mm 7/2.24 No of Core 4 | item11 | 31 | RGM |
12 | 12 | Laying through Floor/ Pavement/Wall.Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish.(ii)Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc. | item12 | 495 | RGM |
13 | 13 | Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. | item13 | 528 | EA |
14 | 14 | SUPPLY AND DELEVERY 40 WATT LED FITTINGS | item14 | 50 | EA |
15 | 15 | Estimated amount | item15 | ||
16 | 16 | 12% GST | item16 | 1 | Nos |
17 | 17 | 1% CESS | item17 | 1 | Nos |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy