Outsourcing Of Ac/Refrigerator Mechanic/ Electrician For 3 X 60 Tr Chiller Plant At Signal Enclave, 3 X 115 Tr Chiller Plant At Hq Cams & Asdc (2 X 40 Tr), Cicp, Adp At Cod & Nbce Lab, Logistic Section At 505 Abw, Oss Building Re-Coil Section, Striping Ba, DELHI CANTT-Delhi

Military Engineer Services-MES has published Outsourcing Of Ac/Refrigerator Mechanic/ Electrician For 3 X 60 Tr Chiller Plant At Signal Enclave, 3 X 115 Tr Chiller Plant At Hq Cams & Asdc (2 X 40 Tr), Cicp, Adp At Cod & Nbce Lab, Logistic Section At 505 Abw, Oss Building Re-Coil Section, Striping Ba. Submission Date for this Tender is 27-02-2020. Refrigerators Tenders in DELHI CANTT Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

23336977
Corrigendum : Outsourcing Of Ac/Refrigerator Mechanic/ Electrician For 3 X 60 Tr Chiller Plant At Signal Enclave, 3 X 115 Tr Chiller Plant At Hq Cams & Asdc (2 X 40 Tr), Cicp, Adp At Cod & Nbce Lab, Logistic Section At 505 Abw, Oss Building Re-Coil Section, Striping Ba
Open Tender
Indian
Delhi
DELHI CANTT
27-02-2020

Tender Details

Outsourcing Of Ac / Refrigerator Mechanic / Electrician For 3 X 60 Tr Chiller Plant At Signal Enclave, 3 X 115 Tr Chiller Plant At Hq Cams & Asdc ( 2 X 40 Tr ) , Cicp, Adp At Cod & Nbce Lab, Logistic Section At 505 Abw, Oss Building Re-Coil Section, Striping Bay And Ard & Erg 3 Eth At 505 Abw, Hq Delhi Area Signal Centre, Das / Dps Unit And Aor Of Ge ( U ) P & M Under Ge ( U ) P&M Delhi Cantt-10.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Feb-2020 Corrigendum No 1 Date 15-02-2020
2 07-Feb-2020 Corrigendum No 2 Date 22-02-2020
3 22-Feb-2020 Corrigendum No 3 Date 27-02-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 81380.0 /-
Tender Value
INR 40.69 Lakhs /-

BOQ Items

NAME OF WORK:- OUTSOURCING OF AC/REFRIGERATOR MECHANIC/ ELECTRICIAN FOR 3 X 60 TR CHILLER PLANT AT SIGNAL ENCLAVE, 3 X 115 TR CHILLER PLANT AT HQ CAMS & ASDC (2 X 40 TR), CICP, ADP AT COD & NBCE LAB, LOGISTIC SECTION AT 505 ABW, OSS BUILDING RE-COIL SECTION, STRIPING BAY AND ARD & ERG 3 ETH AT 505 ABW, HQ DELHI AREA SIGNAL CENTRE, DAS / DPS UNIT AND AOR OF GE (U) P & M UNDER GE(U) P&M DELHI CANTT-10.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 (A) Providing services for outsourcing of AC / refrigerator mechanic for 3 x 60 TR AC Plant & 2 x 40 TR Central type AC Plant installed at Signal Enclave, Delhi Cantt-10, round the clock in three shifts including Sundays and Holidays including provisioning of daily, weekly, monthly, quarterly and half yearly maintenance as per maintenance schedule stipulated and specified to the entire satisfaction of Engineer-in-Charge. The plant will be operated by three AC / refrigerator Mechanics (Skilled Labour) in three shifts by one mechanic in each shift in the following manner complete all as directed by Engr-in-Charge. \n(a) The details of mechanics and shifts are as under :-\n(i) 1st shift of 8 hours with timings 0600 hrs to 1400 hrs.-1 AC/ Refrigerator Mechanic in each shift\n(ii) 2nd shift of 8 hours with timings 1400 hrs to 2200 hrs.-1 AC/ Refrigerator Mechanic in each shift\n(iii) 3rd shift of 8 hours with timings 2200 hrs to 0600 hrs.-1 AC/ Refrigerator Mechanic in each shift\n Total = 03 AC/ Refrigerator Mechanic ................ (i) \n(b) 3 x 60 TR AC plant comprises of the following :-\n(i) Water Cooled chiller package capacity 60 TR complete with condensor – 03 Nos. Make - Voltas.\n(ii) Mono block pump set capacity 10HP for Condenser – 02 Nos. Make - Kirloskar.\n(iii) Mono block pump set capacity 10HP for chiller pump 2900 RPM – 02 Nos. Make - Kirloskar.\n(iv) AHU complete 15000 CFM 4 RD Coil - 01 No. Make - Waves.\n(v) AHU complete 20000 CFM 4 RD Coil - 01 No. Make - Waves.\n(vi) Switch Board (LT Panel) for main plant - 01 No. Make L&T.\n(vii) Switch Board (LT Panel) for AHU complete - 02 Nos. Make L&T.\n(viii) Cooling tower complete with electric motor 5 HP - 01 No & Sintex tank of capacity 3000 ltr. Make-Mihir.\n(c) 2 x 40 TR Central type AC plant comprises of the following :-\n(i) Reciprocating type compressor - 02 Nos. Make - Voltas.\n(ii) Compressor motor 50 HP, 3 phase, 50 C/S - 02 Nos.\n(iii) Condensor shell and tube 40 TR cap – 02 Nos.\n(iv) Condensor water pump set 5 HP - 02 Nos.\n(v) AHU with coiling coil D x type and blower motor complete - 01 No.\n(vi) Electric control panel in plant room complete - 01 No. (vii) Control line device such as expansion valve, thermostat, solenoid valve, HP/LP cut off, oil failure gauge installed making electrical connection, testing and commissioning - 01 No. (viii) Cooling tower - 01 No. Make-Mihir.
2 2 (B) Providing services for outsourcing of AC / refrigerator mechanic for 3 x 115 TR AC Plant installed at HQ CAMS Delhi Cantt, having chilled water cooled type chilled plant including chilled water pump in two shifts excluding Sundays and Holidays including provisioning of daily, weekly, monthly, quarterly and half yearly maintenance as per maintenance schedule stipulated and specified to the entire satisfaction of Engineer-in-Charge. The plant will be operated by two AC / refrigerator Mechanics (Skilled Labour) in two shifts in the following manner, complete all as directed by Engr-in-Charge:-\n(a) The details of mechanics and shifts are as under :-\n(i) 1st shift of 8 hours with timings 0600 hrs to 1400 hrs. - 1 AC/ Refrigerator Mechanic in each shift\n(ii) 2nd shift of 8 hours with timings 1400 hrs to 2200 hrs. - 1 AC/ Refrigerator Mechanic in each shift\n Total = 02 AC/ Refrigerator Mechanic ................ (ii) \n(b) The plant comprises of the following :-\n(i) Water Cooled chilled plant cap 115 TR complete with condensor – 03 Nos. Make - Voltas. \n(ii) Weather making unit with blower and blower motor - 06 Nos. Make - ABB. \n(iii) Cooling coil - 06 Nos.\n(iv) Pre-filter - 06 Lots. Make - Athletic. \n(v) FHP Pump for humidification - 06 Nos. Make - Jyoti. \n(vi) PVC tank for humidification - 06 Nos. \n(vii) Strip heaters of 3 KW for winter heating - 01 Lot. \n(viii) GI/MS 'B Class' ERW pipes and fittings for chilled water piping insulation - 01 Lot. \n(ix) Thermostat - 06 Nos. (x) Humidistat - 06 Nos. \n(xi) Pumping set for condenser water circulation - 02 Nos. Make - Beacon. \n(xii) Pumping set for chilled water circulation - 02 Nos. Make - Beacon. \n(xiii) Cooling tower cap 3 x 115 TR - 01 No. \n(xiv) GI sheet for fabricated ducts including duct insulation- 01 Lot.\n(xv) MS supply / return fresh air diffusers - 01 Lot.\n(xvi) LT Panel board complete - 01 No. (xvii) Electrical fittings - 01 Lot.\n(xviii) Material for electrical wiring - 01 Lot. (xix) PVC tank cap 5000 Ltr. Make-Sintex.\n(xx) Water softening Plant - 01.\n(xxi) MS expansion tank for chilled water of cap 1000 ltrs - 02 Nos.
3 3 (C) Providing services for outsourcing of AC / refrigerator mechanic for 2 x 25 TR AC Plant installed at ARD 3 ETH, 2 X 7.5 TR package type AC plant installed at FVGCE & 2X7.5 TR package type AC plant installed at Re-coil section, 505 ABW Delhi Cantt for one shift excluding Sunday / Gazetted Holidays including provisioning of daily, weekly, monthly, quarterly and half yearly maintenance as per maintenance schedule stipulated and specified to the entire satisfaction of Engineer-in-Charge. The plant will be operated by one AC / refrigerator Mechanics (Skilled Labour) in one shifts in the following manner, complete all as directed by Engr-in-Charge:-\n(a) The details of mechanics and shifts are as under :-\n(i) One shift of 8 hours with timings 0830 hrs to 1630 hrs. - 1 AC/ Refrigerator Mechanic in each shift\n Total = 01 AC/ Refrigerator Mechanic ................ (iii) \n(b) The plant comprises of the following :-\n(i) Scroll water chiller 25 TR – 02 Nos.\n(ii) Condenser pump 3 HP – 02 Nos.\n(iii) Hot water pump 3 HP – 02 Nos.\n(iv) Chilled Water pump 5 HP – 02 Nos.\n(v) AHU from 1500 CFM to 5000 CFM – 07 Nos.\n(vi) Hot Water Generator 30 KW – 01 No.\nPackage type AC Plant of Cap 2 x 7.5 TR at FVGCE, 505 ABW\n(vii) Reciprocating type Compressor Make - Voltas - 02 Nos.\n(viii) Condensing unit complete module DCU SH 75, Make - Voltas -02 Nos.\n(ix) AHU with cooling coil & Blower Motor 3 HP - 01 No.\n(x) Electric control panel in plant room - 01 No.\nPackage type AC Plant of Cap 2 x 7.5 TR at Re-Coil Section, 505 ABW\n(xi) Compressor Reciprocating type Model ADC PU ASPI 75 P Make - Voltas - 02 Nos.\n(xii) Condensing unit , Make - Voltas -02 Nos.\n(xiii) AHU with cooling coil & Blower Motor 3 HP-02 Nos.\n(xiv) Electric control panel in plant room - 01 No.\n(xv) Voltage Stabilizer 20 KVA - 01 No.
4 4 (D) Providing services for outsourcing of AC / refrigerator mechanic for 2 x 24 TR AC Plant installed at ERG, 3 ETH, 505 ABW Delhi Cantt having chilled water cooled type chilled plant including chilled water pump in one shift from 0830 hours to 1630 hours excluding Sunday/ Gazetted Holidays with complete including provisioning of daily, weekly, monthly, quarterly and half yearly maintenance as per maintenance schedule stipulated and specified to the entire satisfaction of Engineer-in-Charge. The plant will be operated by one AC / refrigerator Mechanics (Skilled Labour) in one shifts in the following manner, complete all as directed by Engr-in-Charge:-\n(a) The details of mechanics and shifts are as under :-\n(i) One shift of 8 hours with timings 0830 hrs to 1630 hrs. - 1 AC/ Refrigerator Mechanic in each shift\n Total = 01 AC/ Refrigerator Mechanic ................ (iv) \n(b) The plant comprises of the following :-\n(i) Scroll water chiller 24 TR – 02 Nos.\n(ii) Condenser pump 3 HP – 02 Nos.\n(iii) Hot water pump 3 HP – 02 Nos.\n(iv) Chilled Water pump 5 HP – 02 Nos.\n(v) AHU from 1500 CFM to 5000 CFM – 07 Nos.\n(v) Hot Water Generator 30 KW – 01 No.\n
5 5 (E) Providing services for outsourcing of electrician (Skilled) for attending day to day complaints of internal electrification of all natures such as repair / replacement of point wiring, switches, socket, ceiling rose, light fitting, fan regulator, MCCB, LT panel and cables of all sizes and of any other left over items pertaining to internal electrification as directed by Engr-in-Charge at DAS / DPS unit complete all as specified and directed by Engineer-in-Charge. One electrician shall be deployed in one shift excluding sunday & holidays in the following manner, complete all as specified and directed by Engr-in-Charge. \n(i) One Shift : 0900 hrs to 1700 hrs - 01 Electrician (Skilled Labour) in each shift\n\n(F) Out sourcing of electrician (Skilled) for attending day to day complaints of external electrification of all natures such as repair / replacement of MCB, MCCB, LT panel, AMF Panel, APFC panel, cables of all sizes and of any other left over items pertaining to external electrification as directed by Engr-in-Charge under AOR of GE (U) P & M Delhi Cantt complete all as specified and directed by Engineer-in-Charge. One electrician shall be deployed in one shift excluding sunday & holidays in the following manner, complete all as specified and directed by Engr-in-Charge. \n(i) One Shift : 0900 hrs to 1700 hrs - 01 Electrician (Skilled Labour) in each shift\n Total = 01 + 01 = 02 Electrician (Skilled Labour) ........ (v)
6 6 (G) Providing services for outsourcing of AC / refrigerator mechanic for 3 x 8 TR AC Plant installed at HQ Delhi Area Signal Centre three shifts including Sundays and Gazetted Holidays including provisioning of daily, weekly, monthly, quarterly and half yearly maintenance as per maintenance schedule stipulated and specified to the entire satisfaction of Engineer-in-Charge. The plant will be operated by one AC / refrigerator Mechanics (Skilled Labour) in one shifts in the following manner, complete all as directed by Engr-in-Charge:-\n(a) The details of mechanics and shifts are as under :- \n(i) 1st shift of 8 hrs i:e from 0600 Hrs to 1400 Hrs -- 01 AC/Refrigerator Mechanic (Skilled Labour) per shift \n(ii) 2nd shift of 8 hrs i:e from 1400 Hrs to 2200 Hrs -- 01 AC/Refrigerator Mechanic (Skilled Labour) per shift.\n(iii) 3rd shift of 8 hrs i:e from 2200 Hrs to 0600 Hrs -- 01 AC/Refrigerator Mechanic (Skilled Labour) per shift. Total = 03 AC/ Refrigerator Mechanic ............ (vi) \n(b) The plant is comprising of the following :-\n(i) Reciprocating type Compressor Make- Acces/ Sebroe Model No. SMC 3-65 – 03 Nos.\n(ii) Compressor motor 10HP 3 phase 50 C/S AC – 03 Nos.\n(iii) Condenser shell & tube 8 TR Cap – 03 Nos.\n(iv) Condenser water pump set 3 HP – 02 Nos.\n(v) AHU with cooling coil & Blower Motor 3 HP - 01 No.\n(vi) Electric control panel in plant room - 01 No.\n(vii) Cooling tower FRP with water make up tank - 01 No.\n(viii) Humidity pump -01 No.
7 7 (H) Providing services for outsourcing of AC/ Refrigerator mechanic for Central AC Plants located at CICP COD Complex Delhi Cantt-10, of Capacity (3 x 15 TR) including provisioning of daily, weekly, monthly, quaterly and half yearly maintenance schedule all as per detail stipulated and specified to the entire satisfaction of Engineer-in-Charge to ensure maintaining temperature and humidity conditions as required according to the climatic conditions by deploying one AC/ Refrigerator mechanic (skilled labour) for each shift of 8 hrs in One shift per day basis excluding Sundays & Gazetted holidays. \n(a) The details of mechanics and shifts are as under :-\n(i) 1st shift of 8 hours with timings 0800 hrs to 1600 hrs. - 1 AC/ Refrigerator Mechanic in each shift\n Total = 01 AC/ Refrigerator Mechanic (Skilled Labour)......... (vii) \n\n (b) The plant details are comprising of following :-\n(i) Compressor SMC-4-65, Make - Accel, - 03 Nos.\n(ii) Compressor motor 20 HP 1440 RPM, - 03 Nos. Make - Crompton Greaves\n(iii) Shell and tube tyupe condenser - 03 Nos.\n(iv) Monoblock pumping set 5 HP, 450 LPM at 25 metre head Make - Jyoti - 02 Nos.\n(v) AHU Complette with electric motor 10 HP , 3 Phase 415 Volts Make - Kirloskar - 01 Set.\n(vi) FHP pump for humidification with PVC tank - 01 Set.\n(vii) MS/GI Pipe work with accessories such as gate/stop valves etc.\n(viii) GI ducting for supply/return air complete with accessories.\n(ix) FRP cooling tower complete with make up tank Make - Mihir.\n(x) Main LT Electric Panel cubical type comprising of MCCB, Voltmeter, Ammeter, KWH Meter etc complete - 01 Lot.
8 8 (J) Providing services for outsourcing of AC/ Refrigerator mechanic for Central AC Plants located at ADP COD Complex Delhi Cantt -10, of Capacity (3 x 22.5 TR) round the clock in three shift including sundays and gazatted holidays, including provisioning of daily, weekly, monthly, quaterly and half yearly maintenance schedule all as per detail stipulated and specified to the entire satisfaction of Engineer-in-Charge to ensure maintaining temperature and humidity conditions as required according to the climatic conditions by deploying one AC/ Refrigerator mechanic (skilled labour) for each shift of 8 hrs in three shift per day basis. \n(a) The details of mechanics and shifts are as under :-\n(i) 1st shift of 8 hours with timings 0600 hrs to 1400 hrs. - 1 AC/ Refrigerator Mechanic in each shift\n(ii) 2nd shift of 8 hours with timings 1400 hrs to 2200 hrs. - 1 AC/ Refrigerator Mechanic in each shift\n(iii) 3rd shift of 8 hours with timings 2200 hrs to 0600 hrs. - 1 AC/ Refrigerator Mechanic in each shift\n Total = 03 AC/ Refrigerator Mechanic (Skilled Labour) ....... (viii) \n(b) The plant details are comprising of following :-\n(i) Compressor SMC-8-65 Cap 22.5 TR (Make - Accel - 03 Nos).\n(ii) Compressor motor - 03 Nos.\n(iii) shell and tube type condenser - 03 Nos.\n(iv) Cooling coils - 02 Nos .\n(v) Blower Motor 7.5 HP - 02 Nos.\n(vi) Condenser pump Monoblock (Kirlosker) 02 Nos.\n(vii) Chilled water pump Monoblock (Kirlosker ) 02 Nos.\n(viii) Ahu complete unit - 01 Set.\n(ix) Main Lt electric panel board comprising MCCB, Volts Meter, Ammeter, bus bars, single phase preventer & other accessories fitted in the panel board for smooth functioning of the assets.\n(x) MS/GI Pipe work complete with accessories such as gate/stop valves etc - 01 Lot.\n(xi) GI ducting for supply/return air compete - 01 Lot.\n(xii) FRP cooling tower complete with make up tank and tower motor Make - Mihir - 01 Set.
9 9 (K) Providing services for outsourcing of AC/ Refrigerator mechanic for Package type AC Plant located at Logistic Section, 505 ABW of 3 x 11 TR Capacity round the clock in three shifts including sundays and gazatted holidays,including provisioning of daily, weekly, monthly, quarterly and half yearly maintenance schedule all as per detail stipulated and specified to the entire satisfaction of Engineer-in-Charge to ensure maintaining the specified temperature and R.H to 20-80% respectively by deploying, the plant will be operated by one AC/Refrigerator Mechanic (Skilled Labour) for each shift of 8 hours in three shifts per day basis. \n(a) The details of mechanics and shifts are as under :-\n(i) 1st shift of 8 hours with timings 0600 hrs to 1400 hrs. - 1 AC/ Refrigerator Mechanic in each shift\n(ii) 2nd shift of 8 hours with timings 1400 hrs to 2200 hrs. - 1 AC/ Refrigerator Mechanic in each shift\n(iii) 3rd shift of 8 hours with timings 2200 hrs to 0600 hrs. - 1 AC/ Refrigerator Mechanic in each shift\n Total = 03 AC/ Refrigerator Mechanic (Skilled Labour) ....... (ix) \n (b) The plant details are comprising of following :-\n(i) Hermetic Compressor, Make- Denfoss – 03 Nos\n(ii) Humidity Pump – 01 No\n(iii) Condenser Unit 11 TR Cap - 03 Nos.\n(iv) Electric control panel in plant room - 01 Nos.\n(v) AHU with cooling coil and blower motor 3 HP - 01 Nos.
10 10 (L) Providing services for outsourcing of AC/ Refrigerator mechanic for Central AC Plants located at NBCE Lab 505 ABW Delhi Cantt-10, of Capacity (3 x 30 TR) any season including provisioning of daily, weekly, monthly, quaterly and half yearly maintenance schedule all as per detail stipulated and specified to the entire satisfaction of Engineer-in-Charge to ensure maintaining temperature and humidity conditions as required according to the climatic conditions by deploying one AC/Refrigerator mechanic (skilled labour) for one shift per day basis excluding Sundays & gazetted holidays. \n(a) The details of mechanics and shifts are as under :-\n(i) 1st shift of 8 hours with timings 0800 hrs to 1600 hrs. - 1 AC/ Refrigerator Mechanic in each shift\n Total = 01 AC/ Refrigerator Mechanic ................ (x) \n(b) The plant details are comprising of following :-\n(i) Water cooled chilling unit Cap 30 TR with shell and tube type condenseer Make -ABB -03 Set.\n(i) Compressor motor , 40 HP, 1440 RPM - 03 Nos, Make - voltas 03 Sets.\n(iii) Condenser water pump Set (Monoblock) and chilled water pump set with 7.5 HP Electric motor, 2800 RPM, Model - KDs - 830 Make - Kirloskar - 04 Sets.\n(iv) AHU complete floor mounted Cap 15000 CFM with 10 HP Blower motor, Make ABB-01 Set\n(v) AHU Complete ceiling mounted type Cap 2800 CFM with 2 HP Blower motor Make - ABB - 01 Nos.\n(vi) FRP cooling tower complete with make up water tank Make - Delta, - 01 Nos.\n(vii) Microprocessor control panel - 03 Nos.\n(viii) LT switch board panels with MCCBs voltmeter, Ammeter, selector Switch KWH etc - 01 Nos.\n(ix) MS/GI Pipe work with accessories such as gate/stop valves etc.\n(x) GI ducting for supply/ return Air complete with accessories.
11 11 Total AC/ Refrigerator Mechanic and Electrician (Skilled Labour) per day against above ten locatios = (i) + (ii) + (iii) + (iv) + (v) + (vi) + (vii) + (viii) + (ix) + (x) = 20 Nos AC/ Refrigerator Mechanic & Electrician.\nRates required to be quoted for execution of the work as described in Serial No. 1.00 to 10.00 here-in-before:-
12 12 Refrigerator/ AC Mechanic/ Electrician (Skilled) per person as per existing rates. 3384 Per shift per Mechanic
13 13 Employees Provident Fund as per existing rates as applicable. 3384 Per shift per Mechanic
14 14 Employees State Insurance as per existing rates as applicable. 3384 Per shift per Mechanic
15 15 Contribution of Bonus as per existing rates as applicable. 3384 Per shift per Mechanic
16 16 Over Head & Profit on total of Srl No. 12.00 to 15.00 as applicable. 3384 Per shift per Mechanic
17 17 Labour Welfare Cess (LWC) on total of Srl No.12.00 to 16.00 as applicable. 3384 Per shift per Mechanic
18 18 GST as per existing rates on total of Srl No. 12.00 to 17.00 as applicable. 3384 Per shift per Mechanic
19 19 Notes applicable to BOQ Srl item No 1 to 10 :- \n(a) In case of any leakage of refrigerant gas due to mishandling of plant by the operator / mechanic, topping up of Refrigerant gas and finding of leakage including repairing shall be the responsibility of the contractor.\n(b) General cleanliness and upkeeping existing plants and vegetation within the premises of the plant by deploying additional manpower with T&P if required at any time and all as directed by Engineer-in-Charge.\n(c) Contractor shall made payment through authorised bank and photocopy of receipt of payment shall be attached with RAR/FB.\n(d) Contractor shall monitor the duties of all AC/ refrigerator mechanic ands submit report to concerned Engr-in-Charge/JE E/M regarding availability of manpower and also monitor for watch and guard of installation . Any loss of damage to the plant equipment installed and Govt property in the E/M installation premises shall be made good by the Contractor. Rates quoted by the Contractor are deemed to be included for this clause.\n(f) Duty roster will be submitted by the contractor before commencement of the month for obtaining the approval of JE and Engineer-in-charge. Any change the duty roster will be made by the contractor, only after approval of Engineer-in-charge.\n(g) Contractor should arrange proper uniform with name plate displayed in shirt for the mechanics and its cost shall be deemed to be inclusive in the quoted rate.\n(h) The mechanics shall also be responsible to inform any complaint of non functioning of AC Plant to the Engr-In-Charge. \n(j) The contractor shall provide reliever of AC/ Refrigerator mechanic/Electrician as per labour rules & regulations and the rates for which are deemed to be included in the quoted rate.
20 20 Notes applicable to BOQ Srl item No 1 to 10 (Contd...):- \n(k) Contractor shall be responsible to monitor the duties of all AC/ Refrigerator mechanic/Electrician during change of shift and submit report to concerned Engr-in-Charge/ JE E/M the cost of same is deemed to be included in the quoted rate. \n(l) The rate quoted shall not be less than minimum wages as notified by Govt of India/ State Govt/ Local body whichever is higher as per Schedule ‘A’ (BoQ) i.e. minimum labour wages, EPF, ESIC, bonus, OH & Profit, LWC, Taxes, etc and rate of GST as applicable on the last due date of bid submission. In case of quoted rates are found less than minimum wages as per the existing Govt notification including above factors, it shall be treated as non bonafide bids and will be rejected. \n(m) In such case, the lowest tender shall be determined by the lowest amount amongst valid/ bonafide bids only.\n(n) 'NIL' or 'Zero' Quoting against OH & Profit shall be render the bids as 'Non-bonafide' and will be rejected.\n(o) Contractor is required to quote only upto two digit after decimal place (as per IS No. 2 : 1960) or otherwise it will be considered by rounding off to two digits after decimal place. \n(p) In case of tie amongst bidders, following criteria shall be applied to decide the lowest bidder for acceptance:-\n(aa) When tie is amongst MES enlisted firms, order of acceptance shall be as given below:- \n(i) Bidder of highest class will be considered for acceptance.\n(bb) In MES in case of tie between two or more same class bidder.\n(i) Highest class bidders having average marks in the performance reports stage II of last 5 completed works. (Contractor to submit Affidavit, Work Order, Completion Certificate as & when required)\n(ii) Bidder having highest amount of working capital \n(cc) When tie involves unlisted firm also:-\n(i) Bidder having highest amount of working capital.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail