Supply Reto Fitting And Commissioning Of Electronic Hooter Alarm System Suitable For Various Control And Relay Panels At 220/132/33 Kv S/S Sarh Unde Etd-Ii Kanpur, Kanpur-Uttar Pradesh

Uttar Pradesh Power Transmission Corporation Limited-UPPTCL has published Supply Reto Fitting And Commissioning Of Electronic Hooter Alarm System Suitable For Various Control And Relay Panels At 220/132/33 Kv S/S Sarh Unde Etd-Ii Kanpur. Submission Date for this Tender is 07-02-2020. Alarm Systems Tenders in Kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

23317581
Corrigendum : Supply Reto Fitting And Commissioning Of Electronic Hooter Alarm System Suitable For Various Control And Relay Panels At 220/132/33 Kv S/S Sarh Unde Etd-Ii Kanpur
Open Tender
Indian
Uttar Pradesh
Kanpur
07-02-2020

Tender Details

Supply Reto Fitting And Commissioning Of Electronic Hooter Alarm System Suitable For Various Control And Relay Panels At 220 / 132 / 33 Kv S / S Sarh Unde Etd-Ii Kanpur , Supply , Supply , Retro Fitting & Commissioning Of Electronic Hooter Of Reputed Make ( Minilic / Sk / Tekmec / Equivalent Etc ) Suitable For Control And Relay Panels Of Various Lines And T / Fs Available At Control Room Of 220 Kv S / S Naubasta Kanpur , To Be Wired With Protection Tripping Signals , As Per The Availability Of D / C Sources At S / S , Aux Input 90-250Vdc , Flush Mounting Of Size 96X96mm:- I ) Necessary Cutout And Mounting Will Be Done At Panel . Ii ) Necessary Wiring As Per The Existing Protection Scheme Will Be Done In The Hooter . Iii ) Relays Signals Will Be Checked As Per The Scheme Required Fourth Termination Of Following Size Of Cable As Per Schematics Including Making Necessary Holles In Gland Plate , If Required . Supply And Fixing Of Ferrules And Cable Mark For Each Core As Required And Termination With Proper Size Of Lugs . ( To Be Provided By The Agency If Self ) V ) Beside Above , This Also Includes Of Any Other Supply Are Supply Reto Fitting And Commissioning Of Electronic Hooter Alarm System Suitable For Various Control And Relay Panels At 220 / 132 / 33 Kv S / S Sarh Unde Etd-Ii Kanpur Required To Be Carried Out W . R . T . Commissioning Electronic Hooters . , Note:-I ) The Agency Shall Also Insure The Trouble- Free Functioning Of Above Electronic Hooter Alarm System For A Period Of One Year From The Date Of Its Commission Without Any Additional Charges . Ii ) The Agency Shall Be Execute The Above Supply Reto Fitting And Commissioning Of Electronic Hooter Alarm System Suitable For Various Control And Relay Panels At 220 / 132 / 33 Kv S / S Sarh Unde Etd-Ii Kanpur Without Any Loss / Damaged To Any Other Existing Equipment Installed At The S / S And In Case , Any Loss / Damaged Is Reported / Observed , An Fir Shall Be Lodged Against The Agency Including Termination Of Contract Of Agency .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Feb-2020 Date Date 07-02-2020

Key Value

Document Fees
INR 236 /-
EMD
INR 4000.0 /-
Tender Value
INR 1.90 Lakhs /-

BOQ Items

Name of Work: FOR SUPPLY RETO FITTING AND COMMISSIONING OF ELECTRONIC HOOTER ALARM SYSTEM SUITABLE FOR VARIOUS CONTROL AND RELAY PANELS AT 220/132/33 KV S/S SARH UNDE ETD-II KANPUR
Sl. No. Item Description Item Code / Make Qty Units
1 1 Supply BI01010001010000000000000515BI0100001112
2 1.1 Supply , Retro fitting & commissioning of Electronic Hooter of reputed Make (Minilic/SK/TEKMEC/EQUIVALENT etc) suitable for control and relay panels of various lines and T/Fs available at control room of 220 KV S/S Naubasta Kanpur ,To be wired with protection tripping signals, as per the availability of D/C Sources at S/S, AUX Input 90-250VDC,Flush mounting of size 96x96mm:-\ni) Necessary cutout and mounting will be done at panel.\nii) Necessary wiring as per the existing protection scheme will be done in the hooter.\niii) Relays Signals will be checked as per the scheme required fourth termination of following size of cable as per schematics including making necessary holles in gland plate, if required. Supply and fixing of ferrules and cable mark for each core as required and termination with proper size of lugs. ( To be provided by the agency if self)\nv) Beside above,this also includes of any other supply are work required to be carried out w.r.t. commissioning electronic hooters.\n BI01010001010000000000000515BI0100001114 22 Nos
3 1.2 Note:-i)The agency shall also insure the trouble- free functioning of above Electronic Hooter alarm system for a period of one year from the date of its commission without any additional charges.\nii)The agency shall be execute the above work without any loss / damaged to any other existing equipment installed at the s/s and in case, any loss /damaged is reported / observed, an FIR shall be lodged against the agency including termination of contract of agency.\n BI01010001010000000000000515BI0100001118
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail