Construction Of 3 Storied ( G Plus 2 ) Office Building Of Dig ( Baruipur Range ) Of Correctional Service , Wb And Executive Guest House Along With Allied Works At Presidency Jail Complex Of Baruipur , South 24 Parganas . ( 1St Call ) , Presidency Jail Complex of Baruipur-West Bengal

West Bengal State Police Housing Corporation Limited has published Construction Of 3 Storied ( G Plus 2 ) Office Building Of Dig ( Baruipur Range ) Of Correctional Service , Wb And Executive Guest House Along With Allied Works At Presidency Jail Complex Of Baruipur , South 24 Parganas . ( 1St Call ) . Submission Date for this Tender is 18-02-2020. Building Work Tenders in Presidency Jail Complex of Baruipur West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

23274161
Corrigendum : Construction Of 3 Storied ( G Plus 2 ) Office Building Of Dig ( Baruipur Range ) Of Correctional Service , Wb And Executive Guest House Along With Allied Works At Presidency Jail Complex Of Baruipur , South 24 Parganas . ( 1St Call )
Open Tender
Indian
West Bengal
Presidency Jail Complex of Baruipur
18-02-2020

Tender Details

Construction Of 3 Storied ( G Plus 2 ) Office Building Of Dig ( Baruipur Range ) Of Correctional Service , Wb And Executive Guest House Along With Allied Works At Presidency Jail Complex Of Baruipur , South 24 Parganas . ( 1St Call )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Feb-2020 Corrigendum 1 Date 18-02-2020

Key Value

Document Fees
Refer document
EMD
INR 531409.0 /-
Tender Value
INR 2.65 Crore /-

BOQ Items

Name of Work: Construction of 3 storied (G+2) office Building of DIG (Baruipur Range) of Correctional Service, WB and Executive Guest House along with allied works at Presidency Jail Complex of Baruipur, South 24 Parganas.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Civil works BI01010001010000000000000515BI0100001112
2 2 Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. BI01010001010000000000000515BI0100001113 590.835 SQM
3 3 Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. Depth of excavation not execeeding 1,500 mm BI01010001010000000000000515BI0100001114 956 CuM.
4 4 Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete.\nDepth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. BI01010001010000000000000515BI0100001115 132 CuM.
5 5 Earth work in filling in foundation trenches or plinth with good earth, in layer not exceeding 150mm including watering and ramming etc. layer by layer complete a) With earth obtained from excavation of foundation. BI01010001010000000000000515BI0100001116 396 CuM.
6 6 Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed and consolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity) BI01010001010000000000000515BI0100001117 271 CuM.
7 7 Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work). With carried earth arranged by the contractor within a radius exceeding 5 km. but not exceeding 10 km. including cost of carried earth. BI01010001010000000000000515BI0100001118 230 CuM.
8 8 Providing Bored Cast-in-situ using tripod, winches M25 grade R.C.C. pile in position as per specifications in all kinds of soil including cost of boring using drilling mud to stabilize the bore and flushing the bore of excess mud with freshly prepared drilling fluid by using pumps prior to placing concrete by tremie pipe in one continuous operation and including the cost of all materials and labour for placing of concrete and also including the cost of mobilization and hire charges of all equipment necessary for boring, welding of reinforcement cage as necessary and lowering of reinforcement cage, preparation and placing of concrete, including the cost of concrete but excluding the cost of reinforcement and labour for bending binding etc. complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. Work to be executed as per IS: 2911 (Part II Sec 2). b.iv. 450 mm dia Pile. BI01010001010000000000000515BI0100001119 1500 Mtr.
9 9 Integrity testing of Pile using Low Strain / Sonic\nIntegrity Test / Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerized equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-incharge. Within 50 km. radius from Raj-Bhavan BI01010001010000000000000515BI0100001120 25 Each
10 10 Removal of mud/sludge/slurry/liquid earth obtained during piling work from the working site and disposal of the same beyond the KMC/Municipal or any suitable area with conformity of Municipal Corporation Rules using tanker including loading and unloading the same with pump, clearing the site complete in all respect as per direction of the Engineer-in-charge. For 450mm Pile BI01010001010000000000000515BI0100001121 1500 Mtr.
11 11 Performing Lateral load test on two piles or two groups of piles by introducing a hydraulic jack with gauge between two piles or pile groups under test by applying horizontal loads in increments of about 20% of the estimated safe load at each stage and applying the next increment after the rate of displacement is nearer to 0.1 mm. per 30 minutes till the total displacement becomes, 12 mm at the cutoff level including the cost of arranging the entire set-up, hire charges of all implements including at least two dial gauges, preparing the pile head if necessary, and removal of all arrangement after completion etc. complete in all respect including cost of carriage of all materials and as per IS specification and direction of Engineer-in-charge. BI01010001010000000000000515BI0100001122 2 Each
12 12 Performing Vertical load test on single Pile in accordance with IS:2911(Part-IV) by hydraulic jacks on pile/piles with 1.5 times the design load including preparation of the head of piles with concrete of required strength for receiving the jacks with all ancillary arrangements for setting up gauges, construction of suitable platforms, keeping the loads and dismantling and removing all arrangement etc. complete as per IS specification and direction of Engineer-in-charge. Testing load up to 100 T. BI01010001010000000000000515BI0100001123 2 Each
13 13 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level, and filling joints with powered or local sand. BI01010001010000000000000515BI0100001124 105 SQM
14 14 Cement concrete with graded stone ballast(40 mm size) excluding shuttering . With Pakur Variety 1:3:6 proportion In ground floor and foundation. BI01010001010000000000000515BI0100001125 65.3 CuM.
15 15 Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]\nM 25 Grade. Pakur Variety. FOUNDATION & GROUND FLOOR BI01010001010000000000000515BI0100001126 36.8 CuM.
16 16 Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier]. In Ground Floor and Foundation. With approved concrete pump. FOUNDATION & GROUND FLOOR BI01010001010000000000000515BI0100001127 189 CuM.
17 17 Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier]. In Ground Floor and Foundation. With approved concrete pump.FIRST FLOOR BI01010001010000000000000515BI0100001128 75 CuM.
18 18 Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier]. In Ground Floor and Foundation. With approved concrete pump. SECOND FLOOR BI01010001010000000000000515BI0100001129 80 CuM.
19 19 Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier]. In Ground Floor and Foundation. With approved concrete pump. THIRD FLOOR BI01010001010000000000000515BI0100001130 18 CuM.
20 20 Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof of GF 9 to 12 mm thick approved quality ply board shuttering in any concrete work. FOUNDATION & GROUND FLOOR BI01010001010000000000000515BI0100001131 1295 SqM.
21 21 Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof of GF 9 to 12 mm thick approved quality ply board shuttering in any concrete work. FIRST FLOOR BI01010001010000000000000515BI0100001132 710 SqM.
22 22 Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof of GF 9 to 12 mm thick approved quality ply board shuttering in any concrete work. SECOND FLOOR BI01010001010000000000000515BI0100001133 710 SqM.
23 23 Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof of GF 9 to 12 mm thick approved quality ply board shuttering in any concrete work. THIRD FLOOR BI01010001010000000000000515BI0100001134 140 SqM.
24 24 Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. SAIL/ TATA/RINL. GROUND FLOOR BI01010001010000000000000515BI0100001135 47 M.T.
25 25 Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. SAIL/ TATA/RINL. FIRST FLOOR BI01010001010000000000000515BI0100001136 8.1 M.T.
26 26 Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. SAIL/ TATA/RINL. SECOND FLOOR BI01010001010000000000000515BI0100001137 8.8 M.T.
27 27 Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. SAIL/ TATA/RINL. THIRD FLOOR BI01010001010000000000000515BI0100001138 2 M.T.
28 28 Brick work with 1st class bricks in cement mortar (1:6). IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001139 88 CuM.
29 29 Brick work with 1st class bricks in cement mortar (1:6). GROUND FLOOR BI01010001010000000000000515BI0100001140 61 CuM.
30 30 Brick work with 1st class bricks in cement mortar (1:6). FIRST FLOOR BI01010001010000000000000515BI0100001141 46 CuM.
31 31 Brick work with 1st class bricks in cement mortar (1:6). SECOND FLOOR BI01010001010000000000000515BI0100001142 46 CuM.
32 32 Brick work with 1st class bricks in cement mortar (1:6). THIRD FLOOR BI01010001010000000000000515BI0100001143 21 CuM.
33 33 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in. GROUND FLOOR BI01010001010000000000000515BI0100001144 938 SqM
34 34 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in. FIRST FLOOR BI01010001010000000000000515BI0100001145 144.4 SqM
35 35 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in. SECOND FLOOR BI01010001010000000000000515BI0100001146 165 SqM
36 36 250 mm th. Autoclave aerated concrete block Work with size 625 mm x 250 mm x 125 mm- Grade-I, having drying Shrinkage less than 0.05% conforming to IS: 2185 (Part-3)-1984 made up of fly ash (conforming to IS: 3812-1981, with permissible loss on ignition upto 6% ), lime , cement and laid in Cement Mortar (1:6) complete in all respect as per direction & satisfaction of Engineer -in Charge . In Super Structure, Ground Floor. BI01010001010000000000000515BI0100001147 21.5 CuM.
37 37 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). BI01010001010000000000000515BI0100001148 30 SqM
38 38 Labour for Chipping of concrete surface before taking up Plastering work. BI01010001010000000000000515BI0100001149 1970 Sqm
39 39 Supplying fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core so as to import monolitaheic composite structure as per approved technology of Departmant of Science (DST) to satisfy IS : 4020 door testing performance . 66mm X 90 mm BI01010001010000000000000515BI0100001150 75 Mtr.
40 40 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.\n32 mm thick. GROUND FLOOR BI01010001010000000000000515BI0100001151 7.5 SqM
41 41 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.\n32 mm thick. FIRST FLOOR BI01010001010000000000000515BI0100001152 9.2 SqM
42 42 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.\n32 mm thick. SECOND FLOOR BI01010001010000000000000515BI0100001153 1.85 SqM
43 43 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.\n32 mm thick. THIRD FLOOR BI01010001010000000000000515BI0100001154 2.2 SqM
44 44 Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).\nSal : Malayasian. GROUND FLOOR BI01010001010000000000000515BI0100001155 0.68 Cu.M
45 45 Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).\nSal : Malayasian. FIRST FLOOR BI01010001010000000000000515BI0100001156 0.25 Cu.M
46 46 Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).\nSal : Malayasian. SECOND FLOOR BI01010001010000000000000515BI0100001157 0.33 Cu.M
47 47 Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wideeach and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneerscomplete, including fitting, fixing shutters inposition but excluding the cost of hinges andother fittings in ground floor.(a) 35 mm thick shutters (single leaf). GROUND FLOOR BI01010001010000000000000515BI0100001158 15 SqM
48 48 Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wideeach and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneerscomplete, including fitting, fixing shutters inposition but excluding the cost of hinges andother fittings in ground floor.(a) 35 mm thick shutters (single leaf).FIRST FLOOR BI01010001010000000000000515BI0100001159 12.8 SqM
49 49 Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wideeach and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneerscomplete, including fitting, fixing shutters inposition but excluding the cost of hinges andother fittings in ground floor.(a) 35 mm thick shutters (single leaf). SECOND FLOOR BI01010001010000000000000515BI0100001160 15 SqM
50 50 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface].\n (ii) With 1:4 cement mortar, \nb) 10 mm thick plaster. Ceiling Plaster. GROUND FLOOR BI01010001010000000000000515BI0100001161 255 SqM
51 51 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. \n(ii) With 1:4 cement mortar, \nb) 10 mm thick plaster. Ceiling Plaster.\n FIRST FLOOR BI01010001010000000000000515BI0100001162 255 SqM
52 52 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. \n(ii) With 1:4 cement mortar, \nb) 10 mm thick plaster. Ceiling Plaster. \nSECOND FLOOR BI01010001010000000000000515BI0100001163 265 SqM
53 53 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface].\n (ii) With 1:4 cement mortar,\n b) 10 mm thick plaster. Ceiling Plaster. \nTHIRD FLOOR AND MUMPTY ROOM BI01010001010000000000000515BI0100001164 28 SqM
54 54 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. \nWith 6:1 cement mortar \na) 20mm thick plaster.\n OUTSIDE. GROUND FLOOR BI01010001010000000000000515BI0100001165 1180 SqM
55 55 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. \nWith 6:1 cement mortar \na) 20mm thick plaster.\n FIRST FLOOR BI01010001010000000000000515BI0100001166 275 SqM
56 56 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. \nWith 6:1 cement mortar \na) 20mm thick plaster. \nSECOND FLOOR BI01010001010000000000000515BI0100001167 275 SqM
57 57 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface].\nWith 6:1 cement mortar\n a) 20mm thick plaster.\n THIRD FLOOR AND MUMPTY ROOM BI01010001010000000000000515BI0100001168 265 SqM
58 58 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. \nWith 6:1 cement mortar \nb) 15mm thick plaster. \nINSIDE GROUND FLOOR BI01010001010000000000000515BI0100001169 860 SqM
59 59 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. \nWith 6:1 cement mortar \nb) 15mm thick plaster. \nINSIDE FIRST FLOOR BI01010001010000000000000515BI0100001170 625 SqM
60 60 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. \nWith 6:1 cement mortar\n b) 15mm thick plaster. \nINSIDE. SECOND FLOOR BI01010001010000000000000515BI0100001171 780 SqM
61 61 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]. \nWith 6:1 cement mortar \nb) 15mm thick plaster.\n INSIDE. THIRD FLOOR AND MUMPTY ROOM BI01010001010000000000000515BI0100001172 90 SqM
62 62 Neat Cement Punning above 1.5mm thick in Wall dado, Window Sill Floor and Drain etc Note Cement 0.152 cum 100 Sqmts. ALL FLOOR BI01010001010000000000000515BI0100001173 190 SqM
63 63 Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) i) Water based interior grade Acrylic Primer.\nOne Coat, ALL FLOORS BI01010001010000000000000515BI0100001174 3160 SqM
64 64 Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :Standard Quality (Two coats) ALL FLOORS BI01010001010000000000000515BI0100001175 3160 SqM
65 65 Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) BI01010001010000000000000515BI0100001176 3160 SqM
66 66 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. \nGROUND FLOOR. Two coats BI01010001010000000000000515BI0100001177 2113 SqM
67 67 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. \nFIRST FLOOR . Two coats BI01010001010000000000000515BI0100001178 275 SqM
68 68 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.\n SECOND FLOOR . Two coats BI01010001010000000000000515BI0100001179 275 SqM
69 69 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. \nTHIRD FLOOR AND MUMPTY ROOM. \nTwo coats BI01010001010000000000000515BI0100001180 265 SqM
70 70 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Normal Acrylic Emulsion. \n GROUND (External surface ) \nTwo coats BI01010001010000000000000515BI0100001181 2073 SqM
71 71 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffol. Two coatsding and all incidental charges but excluding the cost of primer.a) Normal Acrylic Emulsion. \nFIRST FLOOR. \nTwo coats BI01010001010000000000000515BI0100001182 275 SqM
72 72 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Normal Acrylic Emulsion.\n SECOND FLOOR. \n Two coats BI01010001010000000000000515BI0100001183 275 SqM
73 73 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.\na) Normal Acrylic Emulsion.\n THIRD FLOOR AND MUMPTY ROOM. \n Two coats BI01010001010000000000000515BI0100001184 265 SqM
74 74 Primming One coat on Timber or Plaster surface with Synthetic Oil bound Primer of approved Quality inclusing smooting surface by sand Papering etc BI01010001010000000000000515BI0100001185 158 SqM
75 75 Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. BI01010001010000000000000515BI0100001186 135 SqM
76 76 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : \nOn timber or plastered surface :With super gloss (hi-gloss) - (iv) Two coats (with any shade except white) BI01010001010000000000000515BI0100001187 158 SqM
77 77 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : iv) On Steel and other Metal Surface.With super gloss (hi-gloss). Two coat with any shade except white BI01010001010000000000000515BI0100001188 135 SqM
78 78 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) WALL With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative at Wall. GROUND FLOOR BI01010001010000000000000515BI0100001189 105 SqM
79 79 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) WALL With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative at Wall. FIRST FLOOR BI01010001010000000000000515BI0100001190 105 SqM
80 80 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) WALL With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative at Wall. SECOND FLOOR BI01010001010000000000000515BI0100001191 90 SqM
81 81 Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). In Ground Floor: Sizes-300 mm x300mm x10 mm with breaking strength > 1200 N. GROUND FLOOR BI01010001010000000000000515BI0100001192 28 SqM
82 82 Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). Sizes-300 mm x300mm x10 mm with breaking strength > 1200 N.FIRST FLOOR BI01010001010000000000000515BI0100001193 58 SqM
83 83 Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). Sizes-300 mm x300mm x10 mm with breaking strength > 1200 N.. SECOND FLOOR BI01010001010000000000000515BI0100001194 55 SqM
84 84 Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) = 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick\ncement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of\nEngineer-in-Charge. (Note: This work should not be\nexecuted without specific permission of Superintending Engineer) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5\nmm thick). GROUND FLOOR BI01010001010000000000000515BI0100001195 160 SqM
85 85 Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) = 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) (size not Iess than 600mmX 600 mm X 9.5 mm thick) FIRST FLOOR BI01010001010000000000000515BI0100001196 142 SqM
86 86 Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) = 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick\ncement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of\nEngineer-in-Charge. (Note: This work should not be\nexecuted without specific permission of Superintending Engineer)(size not Iess than 600mmX 600 mm X 9.5 mm thick). SECOND FLOOR BI01010001010000000000000515BI0100001197 168 SqM
87 87 18 mm. to 22 mm. thick, kota stone slab setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigmentmatching the stone shade, including grinding & polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m] Extra cost of labour for prefinished and premoulded Nosing to treads of steps. GROUND FLOOR BI01010001010000000000000515BI0100001198 90 SqM
88 88 18 mm. to 22 mm. thick, kota stone slab setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigmentmatching the stone shade, including grinding & polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m] FIRST FLOOR BI01010001010000000000000515BI0100001199 25 SqM
89 89 18 mm. to 22 mm. thick, kota stone slab setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigmentmatching the stone shade, including grinding & polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m] SECOND FLOOR BI01010001010000000000000515BI0100001200 25 SqM
90 90 18 mm. to 22 mm. thick, kota stone slab setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigmentmatching the stone shade, including grinding & polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m] . THIRD FLOOR BI01010001010000000000000515BI0100001201 8 SqM
91 91 Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) includingmaking suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shade including grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]. GROUND FLOOR BI01010001010000000000000515BI0100001202 30 SqM
92 92 Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) includingmaking suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shade including grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]. FIRST FLOOR BI01010001010000000000000515BI0100001203 10 SqM
93 93 Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) includingmaking suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shade including grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]. SECOND FLOOR BI01010001010000000000000515BI0100001204 10 SqM
94 94 Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) includingmaking suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shade including grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]. THIRD FLOOR BI01010001010000000000000515BI0100001205 2.4 SqM
95 95 Extra cost of labour for pre finish and pre moulded nosing to treads of steps,railing,window sil etc of kota stone. BI01010001010000000000000515BI0100001206 135 RM
96 96 Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (iii) 35 mm. thick. GROUND FLOOR BI01010001010000000000000515BI0100001207 3 SqM
97 97 Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (iii) 35 mm. thick. FIRST FLOOR BI01010001010000000000000515BI0100001208 2.1 SqM
98 98 Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (iii) 35 mm. thick. SECOND FLOOR BI01010001010000000000000515BI0100001209 2.1 SqM
99 99 Supplying, fitting and fixing windows and ventilators with or with out integrated grills conforming to IS 1038 - 1975 and manufactured from rolled steel sections conforming to IS 7452 - 1974 with non -friction projecting type ,box type hinges , glazing clips ,lugs locking bracket , handle plat etc, including hoisting in position , straightening if required , fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Fixed type steel windows as per IS Sizes with horizontal glazing bars. GROUND FLOOR BI01010001010000000000000515BI0100001210 7.5 SqM
100 100 Supplying, fitting and fixing windows and ventilators with or with out integrated grills conforming to IS 1038 - 1975 and manufactured from rolled steel sections conforming to IS 7452 - 1974 with non -friction projecting type ,box type hinges , glazing clips ,lugs locking bracket , handle plat etc, including hoisting in position , straightening if required , fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Fixed type steel windows as per IS Sizes with horizontal glazing bars. FIRST FLOOR BI01010001010000000000000515BI0100001211 7.45 SqM
101 101 Supplying, fitting and fixing windows and ventilators with or with out integrated grills conforming to IS 1038 - 1975 and manufactured from rolled steel sections conforming to IS 7452 - 1974 with non -friction projecting type ,box type hinges , glazing clips ,lugs locking bracket , handle plat etc, including hoisting in position , straightening if required , fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Fixed type steel windows as per IS Sizes with horizontal glazing bars. SECOND FLOOR BI01010001010000000000000515BI0100001212 7.45 SqM
102 102 Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) i) 4mm thick.All Floor BI01010001010000000000000515BI0100001213 24 SqM
103 103 Extra for fixing glass panes in steel window. BI01010001010000000000000515BI0100001214 24 SqM
104 104 Supplying,fitting & fixing of 2-Track / 3-Track Aluminium slidingWindow of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film. Natural white. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. BI01010001010000000000000515BI0100001215 198 Kg
105 105 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 4mm thick coloured / tinted / smoke glass. BI01010001010000000000000515BI0100001216 30 SqM
106 106 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 6mm thick coloured / tinted / smoke glass. BI01010001010000000000000515BI0100001217 58 SqM
107 107 Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. For sliding windows. U' shaped EPDM gasket for frames. BI01010001010000000000000515BI0100001218 190 Mtr.
108 108 Supplying maruti lock (100mm) BI01010001010000000000000515BI0100001219 32 Pair
109 109 Supplying PVC rollers for sliding windows as per direction of Engineer\nin charge. BI01010001010000000000000515BI0100001220 48 Each
110 110 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). Movable door shutter. Door frame. (Top & sides). BI01010001010000000000000515BI0100001221 82 Mtr.
111 111 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). Movable door shutter. Shutter : Top rail. BI01010001010000000000000515BI0100001222 20 Mtr.
112 112 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). Movable door shutter. Shutter : Bottom rail. BI01010001010000000000000515BI0100001223 20 Mtr.
113 113 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). Movable door shutter. Shutter : Lock rail BI01010001010000000000000515BI0100001224 20 Mtr.
114 114 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). Movable door shutter. Shutter : Door vertical. BI01010001010000000000000515BI0100001225 84 Mtr.
115 115 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). Movable door shutter. Shutter : Glazing clip. BI01010001010000000000000515BI0100001226 260 Mtr.
116 116 Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units: (A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixingglass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers. 3 /4 track sliding window. BI01010001010000000000000515BI0100001227 30 SqM
117 117 Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units: (B) Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking rangement, flush bolt, glazing clips and all other necessary fittings, fixtures, adhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry set neoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge. The rate includes the hire charge of all tools and plants, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded alumium sections, glass, panel boards neoprene / EPDM gasket, locking arrangement, weather gasket / wool pile, floor spring, top pin, handle, tower bolt, glazing clips etc. (10% rate reduction has to be made for swing doors or partitions where floor sping is not used. 10% enhancement of rate is to be made where door frame of extruded aluminium sections has to be fitted and fixed to masonry wall. 5% rate enhencement may be allowed for double leaf swing door. Payment shall be made for the shutter area only exept where door frame is fixed the entire opening shall be taken to consideration.Payment for door frame\nsections are to be paid seperately). BI01010001010000000000000515BI0100001228 52 SqM
118 118 12mm thick cleared toughened glass coforming to IS: 2553-1992 (Part-II) BI01010001010000000000000515BI0100001229 6.2 SqM
119 119 Supplying heavy duty hydraulic double action floor spring along with top pin/set of pivots conforming to IS: 6315 or any approved make as per direction of Engineer in charge. BI01010001010000000000000515BI0100001230 2 Each set
120 120 Supplying heavy duty top pin/set of pivots of local make and approved by the Engineer-in-charge. (This item to be provided where floor spring not used). BI01010001010000000000000515BI0100001231 2 pair
121 121 a) M.S. or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq. Mtr . GROUND FLOOR BI01010001010000000000000515BI0100001232 5.8 Qntl
122 122 a) M.S. or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq. Mtr . FIRST FLOOR BI01010001010000000000000515BI0100001233 5.6 Qntl
123 123 a) M.S. or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq. Mtr . SECOND FLOOR BI01010001010000000000000515BI0100001234 5.6 Qntl
124 124 Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. IN GROUND FLOOR BI01010001010000000000000515BI0100001235 14 SqM
125 125 Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately). 40mm X 6mm, 250mm Length BI01010001010000000000000515BI0100001236 42 Each
126 126 Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately). 40mm X 6mm, 125mm Length BI01010001010000000000000515BI0100001237 150 Each
127 127 Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark . 100mm X 50mm X 1.25mm BI01010001010000000000000515BI0100001238 80 Each
128 128 Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark . 75mm X 47mm X 1.70mm BI01010001010000000000000515BI0100001239 30 Each
129 129 Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. 250mm long BI01010001010000000000000515BI0100001240 42 Each
130 130 Anodised aluminium floor door stopper\n BI01010001010000000000000515BI0100001241 10 Each
131 131 Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. 150 mm long X 10mm dia bolt. BI01010001010000000000000515BI0100001242 20 Each
132 132 Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. 300 mm long X 10mm dia bolt. BI01010001010000000000000515BI0100001243 85 Each
133 133 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal / Round rod). 125 mm grip x 12 mm dia rod. BI01010001010000000000000515BI0100001244 24 Each
134 134 Godrej Hydraulic door closer fitted and fixed complete.(b) Medium type BI01010001010000000000000515BI0100001245 20 Each
135 135 Supplying 'Godrej' mortice lock chromium plated with keys 6 levers includin fitting & fixing complete. BI01010001010000000000000515BI0100001246 12 Each
136 136 Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required) BI01010001010000000000000515BI0100001247 409 SqM
137 137 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety BI01010001010000000000000515BI0100001248 27.5 CuM.
138 138 M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. I) For structural members of specified sections weighing less than 22.5 Kg./m BI01010001010000000000000515BI0100001249 0.56 MT
139 139 Plumbing & Sanitary. Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made. (a) For Exposed Work -- PVC Pipes (Dia). 50 mm BI01010001010000000000000515BI0100001250 30 Mtr.
140 140 Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made. (a) For Exposed Work -- PVC Pipes (Dia). 32mm BI01010001010000000000000515BI0100001251 60 Mts
141 141 Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made. (a) For Exposed Work -- PVC Pipes (Dia). 25 mm BI01010001010000000000000515BI0100001252 35 Mtr.
142 142 Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made.(b) For Concealed work. 15 mm BI01010001010000000000000515BI0100001253 130 Mtr.
143 143 Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made. (b) For Concealed work. 20 mm BI01010001010000000000000515BI0100001254 85 Mtr.
144 144 Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made. (b) For Concealed work. 25 mm BI01010001010000000000000515BI0100001255 30 Mtr.
145 145 Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 40mm BI01010001010000000000000515BI0100001256 4 Each
146 146 Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 32 mm BI01010001010000000000000515BI0100001257 20 Each
147 147 Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 25 mm BI01010001010000000000000515BI0100001258 25 Each
148 148 Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. With 'P' trap BI01010001010000000000000515BI0100001259 10 Each
149 149 Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.E.W.C. Plastic (hallow type) white BI01010001010000000000000515BI0100001260 10 Each
150 150 Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.White BI01010001010000000000000515BI0100001261 10 Each
151 151 Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(ii) 450 mm X 300 mm size BI01010001010000000000000515BI0100001262 15 Each
152 152 Supplying, fitting and fixing pedestal of approved make for wash basin (white) BI01010001010000000000000515BI0100001263 15 Each
153 153 Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only \n(ii) 630X550X180 mm BI01010001010000000000000515BI0100001264 6 Each
154 154 Supplying, fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. Polythene Flush Pipe. BI01010001010000000000000515BI0100001265 10 Each
155 155 Supplying, fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with coupling at one end fitted with necessary clamps. 1050 mm long BI01010001010000000000000515BI0100001266 23 Each
156 156 Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iv) 750 mm long BI01010001010000000000000515BI0100001267 16 Each
157 157 Supplying ,fitting and fixing 15 mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510 & 510 (A) Model - Tropical / Sumthing Special of ESSCO or similar brand). BI01010001010000000000000515BI0100001268 8 Each
158 158 Chromium plated Bib Cock (angular shape with wall flange) (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar brand). BI01010001010000000000000515BI0100001269 10 Each
159 159 Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). BI01010001010000000000000515BI0100001270 18 Each
160 160 Chromium plated concealed Stop Cock heavy duty (Equivalent to Code No. 5083 & Model - Florentine of Jaquar or similar brand). BI01010001010000000000000515BI0100001271 10 Each
161 161 Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.i) 635 mm X 395 mm X 420 mm BI01010001010000000000000515BI0100001272 2 Each
162 162 Supplying, fitting and fixing porcelain partition wall of approved make of size 618 mm X 310 mm complete in all respect. BI01010001010000000000000515BI0100001273 2 Each
163 163 Supplying, fitting and fixing urinal flush pipe fittings of approved brand.(a) C.P. urinal flush pipe fittings range of one BI01010001010000000000000515BI0100001274 3 Each
164 164 Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm BI01010001010000000000000515BI0100001275 10 Each
165 165 Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar\nor similar brand). BI01010001010000000000000515BI0100001276 10 Each
166 166 Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). BI01010001010000000000000515BI0100001277 10 Each
167 167 Supplying, fitting and fixing towel rail with two brackets. C.P. over brass 25 mm dia. and 600 mm long BI01010001010000000000000515BI0100001278 20 Each
168 168 Suppling fitting fixing liquid soap container b) PTMT (Prayag or Equivelent) BI01010001010000000000000515BI0100001279 10 Each
169 169 Suppling fitting fixing soap holder a) PTMT (Prayag or Equivelent) BI01010001010000000000000515BI0100001280 12 Each
170 170 Supplying fitting fixing PTMT smart shelf of approved make of size 300 mm BI01010001010000000000000515BI0100001281 12 Each
171 171 Supplying, fitting and fixing C.I. round grating. (ii) 150 mm dia BI01010001010000000000000515BI0100001282 19 Each
172 172 Supplying, fitting and fixing C.I. square jalli. (ii) 150 mm BI01010001010000000000000515BI0100001283 10 Each
173 173 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length. b) 110 mm BI01010001010000000000000515BI0100001284 145 Mtr.
174 174 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length. (i) Door Tee (110 mm) BI01010001010000000000000515BI0100001285 20 Each
175 175 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length. (ii) Door Y (LH) & (RH).(110 MM) BI01010001010000000000000515BI0100001286 18 Each
176 176 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length. (iii) Door Bend T.S 110 mm BI01010001010000000000000515BI0100001287 15 Each
177 177 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length. (iv) Plain Tee 110 mm BI01010001010000000000000515BI0100001288 18 Each
178 178 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length. (v)Bend 45 Degree 110 mm BI01010001010000000000000515BI0100001289 12 Each
179 179 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length. (vi) Pipe Clip 110 mm BI01010001010000000000000515BI0100001290 144 Each
180 180 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length. c) 160 mm BI01010001010000000000000515BI0100001291 65 metre
181 181 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length. (i) Door Tee (160 mm) BI01010001010000000000000515BI0100001292 12 Each
182 182 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length. (ii) Door Bend T S.(160 MM) BI01010001010000000000000515BI0100001293 18 Each
183 183 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length.(iv) Plain Tee (160 mm) BI01010001010000000000000515BI0100001294 18 Each
184 184 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length. (v) Bend 87.5 Degree (160 mm) BI01010001010000000000000515BI0100001295 20 Each
185 185 Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992. (A) (i) Single Socketed 3 Mtr. Length. (vi) Pipe Clip 160 mm BI01010001010000000000000515BI0100001296 75 Each
186 186 Labour for fitting and fixing U.P.V.C pipes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials). (A) Above ground (ii) 110 mm BI01010001010000000000000515BI0100001297 145 Mtr.
187 187 Labour for fitting and fixing U.P.V.C pipes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials). (A) Above ground (iii) 160 mm BI01010001010000000000000515BI0100001298 20 Mtr.
188 188 Labour for fitting and fixing U.P.V.C pipes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials). (B) Below Ground. (iii) 160 mm BI01010001010000000000000515BI0100001299 45 Mtr.
189 189 Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer 2000 litre capacity BI01010001010000000000000515BI0100001300 2 Each
190 190 Labour for hoisting plastic water storage tank. (ii) Above 1500 litre upto 5000 litre capacity. litre capacity. BI01010001010000000000000515BI0100001301 2 Each
191 191 Labour for punching hole in plastic water storage tank upto 50 mm dia BI01010001010000000000000515BI0100001302 8 Each
192 192 Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external\nsurfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Pakur variety. (SAIL/TATA/RINL) BI01010001010000000000000515BI0100001303 12 Each
193 193 Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. With Pakur variety. (SAIL/TATA/RINL). For 30 users. BI01010001010000000000000515BI0100001304 1 Each
194 194 Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary. Depth up to 300mm. BI01010001010000000000000515BI0100001305 525 SqM
195 195 Construction of granular sub-base by providing graded material, mixing by mix in place method with Rotavator at OMC, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants including cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).(ii) Grading – II BI01010001010000000000000515BI0100001306 105 CuM.
196 196 60 mm thick interlocking designer concrete paver block M- 35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.(ii) Coloured Decorative BI01010001010000000000000515BI0100001307 220 Sqm
197 197 Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409 of Specifications for Road & BridgeWorks of MoRT&H (5th Revision). (The rate is inclusive of cost of all materials, labour, hire and usage charges of machinery and all incidental charges in this connection.)A) Using Concrete Mixer BI01010001010000000000000515BI0100001308 215 Mtr.
198 198 Supplying and fixing grasses tiles of grass Maxican Carpet/Selection No. 1 Healthy & fresh grasses (size 1'x1' or bigger) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from wees and fit for mowing including supplying good earth as required by Engineer-in-charge. (Rate includes supply of labour, tools & plants including materials) BI01010001010000000000000515BI0100001309 250 SqM
199 199 Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20%, one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary watering and finally fine dressing, levelling etc., including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5m complete. This includes supply of labour, tools & plants including materials. Planting hedge plants in two rows at 30cm apart BI01010001010000000000000515BI0100001310 60 SqM
200 200 ELECTRICAL WORKS(Part -A ) Scheduled item. \nSupply & Fixing 415V 125A TPN (LT) switch in suitable SS enclosure with HRC fuses on LS & NL on angle iron frame on wall incl. earthing attachment.(Pwd page-D3 Item no. 4 (a) BI01010001010000000000000515BI0100001311 1 set
201 201 Supply & Fixing 415V 63A TPN (LT) switch in suitable SS enclosure with HRC fuses on LS & NL on angle iron frame on wall incl. earthing attachment.(Pwd page-D3 Item no. 4 (a) BI01010001010000000000000515BI0100001312 2 set
202 202 Supply & Fixing 415V 125A Four pole on load change over switch in suitable SS enclosure (Make L&T) on angle iron frame on wall incl. earthing attachment.(Pwd page-D2 Item no. 3 (a)) BI01010001010000000000000515BI0100001313 1 set
203 203 Supply & Fixing 415V 32 A TPN (LT) switch in suitable SS enclosure with HRC fuses on LS & NL on angle iron frame on wall incl. earthing attachment.(pump )(Pwd page-D3 Item no. 4 (a) BI01010001010000000000000515BI0100001314 1 set
204 204 Supplying & fixing 415V 315A sheet metal (16 SWG) Iron Clad Busbar chambers of on angle iron frame on wall, incl. earthing attachment and painting as required ( CU. BAR BOX-500 X 150 MM. CU BAR- 40 X 4MM(4 BAR)(Pwd page-D13 Item no. 19 (b) BI01010001010000000000000515BI0100001315 0.8 mtr
205 205 Supply & fixing of 240V 32A DP MCB (Legrand) in DP SS enclosure (Legrand) incl earthing attachment. ( FOR ROOF LIGHTING )(Pwd page-D6,9 Item no.7;11) BI01010001010000000000000515BI0100001316 5 set
206 206 Supply & fixing double door 4 way Vertical TPN MCB DB (Legrand) with IP 42/43 protection SS enclosure ressed in wall & mending good the damages to original finish incl. interconnection with suitable size of copper wire, neutral link & earthing attachment comprising of the following accessories (Pwd page-D 6;8;11 Item no. 10) \na) 100A Four pole thermal magnetic MCCB- 1 no (25 KA/35KA)\nb) 63A TP MCB ---2 nos\nc)16 A to 32A SP MCB --- 6 nos BI01010001010000000000000515BI0100001317 1 set
207 207 Supply & fixing way double door Horizontal 6 wayTPNMCB DB (legrand ) concealed in wall incl inter connection with suitable copper wire, neutral link & earthing attachment comprising of the followings (All Legrand)(Pwd page-D 6;5 Item no. 7;6) (3nos EMR & 1 no normal)\na) 100A four pole MCB isolater --- 1 no\nb) 16 to 32A (as reqd.) SP MCB --- 18 nos BI01010001010000000000000515BI0100001318 2 set
208 208 Supply & Fixing (2+8) way SPN MCBDB (Legrand ) with IP-42/43 protection Concealed in wall & mending good the damages to original finish incl. Interconnection with suitable copper wire & nuetral link incl. earthing attachment comprising with the following (All Legrand):(Pwd page-D 6;9 Item no. 7,13)(4nos EMR)\na) 40A DP MCB isolator & necy. connection --- 1 no\nb) 6 to 16A SP MCB as required breaking capacity \n 10KA & C characteristic ---- 8 nos BI01010001010000000000000515BI0100001319 7 set
209 209 Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed(Pwd page-F2 Item no. 1 (a) 4 x 35 sq mm BI01010001010000000000000515BI0100001320 50 mtr
210 210 Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed(Pwd page-F2 Item no. 1 (a) 4 x 16 sq mm BI01010001010000000000000515BI0100001321 40 mtr
211 211 Laying of the following Alu. armoured cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed(Pwd page-F2 Item no. 1 (a) 2 x 6 sq mm BI01010001010000000000000515BI0100001322 180 mtr
212 212 Laying of the following XLPE Al armoured cable after cutting floor /pavement / wall and making holes incl, embedding tha cable at an average depth as below & mending good the damages to original finish:-(Pwd page-F 3 Item no. 5) 2 x6 sq mm BI01010001010000000000000515BI0100001323 40 mtr
213 213 Supply & laying medium gauge G.I.Pipe(ISI-Medium) for cable protection (Pwd page-F6 Item no. 11) \n 40 mm dia BI01010001010000000000000515BI0100001324 80 mtr
214 214 Supply & laying medium gauge G.I.Pipe(ISI-Medium) for cable protection (Pwd page-F6 Item no. 11) \n 80 mm dia for pole BI01010001010000000000000515BI0100001325 20 mtr
215 215 Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable:(Pwd page-F 4;5 Item no.7;8) 4 x 35 sq mm BI01010001010000000000000515BI0100001326 6 set
216 216 Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable:(Pwd page-F 4;5 Item no.7;8) 4 x 16 sq mm BI01010001010000000000000515BI0100001327 6 set
217 217 Supply & fixing compression type gland with brass gland brass ring incl. socketing the ends off by crimping method incl. S/F solderless socket (Dowels make) & jointing ,materials etc. Of the following XLPE/A cable:(Pwd page-F 4;5 Item no.7;8) 2 x 6 sq mm BI01010001010000000000000515BI0100001328 12 set
218 218 Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through alkathene pipe recessed in wall. (Pwd page-E9 Item no. 1 & E3) 4x10+2x6 sq mm though 25mm Alka Pipe(VTPN TO TPN ) BI01010001010000000000000515BI0100001329 20 mtr
219 219 Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through alkathene pipe recessed in wall. (Pwd page-E9 Item no. 1) 4x6+2x4 sqmm though 25mm Alka Pipe for BI01010001010000000000000515BI0100001330 50 mtr
220 220 Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through alkathene pipe recessed in wall. (Pwd page-E9 Item no. 1) 2x4+1x2.5 sq mm though 25mm Alka Pipe(SPNDB & AC ) BI01010001010000000000000515BI0100001331 120 mtr
221 221 Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through alkathene pipe recessed in wall. (Pwd page-E9 Item no. 1) 2x2.5+1x1.5 sqmm through 19mm Alka.pipe ( P/P) BI01010001010000000000000515BI0100001332 250 mtr
222 222 Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through alkathene pipe recessed in wall. (Pwd page-E9 Item no. 1) \n3x1.5 sq mm through 19mm Alkathene pipe BI01010001010000000000000515BI0100001333 100 mtr
223 223 Distn. wiring in 3 x 1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/ fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish (Avg 9 mtr):(Pwd page-E20 Item no.1) BI01010001010000000000000515BI0100001334 316 Pts
224 224 Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded 'FR' PVC insulated & unsheathed copper wire (brand approved by EIC) in 19mm bore, 3mm thickpolythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pin modular type plug socket & modular type switch(Brand appr. by EIC) incl. S&F earth continuity wire fixed on 4 module GI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. (on board)(Pwd page-E20 Item no.3) BI01010001010000000000000515BI0100001335 35 Pts
225 225 Distribution wiring in 1.1 KV grade 3 x 1.5 sq mm single core stranded 'FR' PVC insulated & unsheathed copper wire (brand approved by EIC) in 19mm bore, 3mm thickpolythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240V 6A 3 pin modular type plug socket & modular type switch(Brand appr. by EIC) incl. S&F earth continuity wire fixed on 4 module GI switch board with 3/4 module top cover plate flushed in wall incl mending good damage to original finish. (Ave run 4.5 mtr)(Pwd page-E20 Item no.3) BI01010001010000000000000515BI0100001336 10 Pts
226 226 Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light points with 2 no. 2 way Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish.(Average run 9mtr)(Pwd page no E-24,item no-2.a) BI01010001010000000000000515BI0100001337 12 Pts
227 227 Supply & fixing of Modular type computer plug board of 8module GI box with cover plate recessed in wall comprising of the following(All cabtree): \na) 16A socket ---1 set b) 16 a switch --- 2 set\nb) 6A socket --- 2 sets BI01010001010000000000000515BI0100001338 18 set
228 228 Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu\nwire and earth continuity wire etc(Pwd page-E19 Item no.17) BI01010001010000000000000515BI0100001339 10 set
229 229 Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wirE (AC)(Pwd page-E17 Item no.5(a)\n BI01010001010000000000000515BI0100001340 10 set
230 230 Supply & fixing of Modular type 16A 3 pin modular type plug socket (Brand approved by EIC) with 16 A Modular type switch without plug top on of 4 module GI box with cover plate recessed in wall comprising of the following (All cabtree): (Pwd page-E18 Item no.9(b) a) 16A switch ---1 set \nb)16A socket - - 1 set BI01010001010000000000000515BI0100001341 17 set
231 231 Fixing only singal / twin fluorescent light complete with all accessories directly on wall/ceilinh/HW round block and suitable size of MS fastener,ceiling plate, nipples etc. as required(Pwd page-C 2 Item no.14(D) BI01010001010000000000000515BI0100001342 74 set
232 232 Supply & Fixing louver AL shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as following diameter(Pwd page-D14 Item no.32(a) \n 9" Exhaust fan(23cm) BI01010001010000000000000515BI0100001343 17 each
233 233 Supply & Fixing louver AL shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as following diameter(Pwd page-D14 Item no.32(a) \n12" Exhaust fan(30cm) BI01010001010000000000000515BI0100001344 2 each
234 234 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:(Pwd page-c4 Item no.28) 9" Exhaust fan(23cm) BI01010001010000000000000515BI0100001345 17 each
235 235 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:(Pwd page-c4 Item no.28) \n 12" Exhaust fan(30cm) BI01010001010000000000000515BI0100001346 2 each
236 236 Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering tha box(Pwd page-D14 Item no.31) BI01010001010000000000000515BI0100001347 58 set
237 237 Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.(Pwd page-E18 Item no.10) BI01010001010000000000000515BI0100001348 58 each
238 238 Erection of up to9.00 m ST bend pole with sole plate in CC foundation (600x600x150mm) thick CC (4:2:1) base block below sole plate with hard jhama metal incl CC (6:3:1) muffing 0.30 m dia 03.0 m above ground level incl 3mm thick neat cemented finish and GI earth bolt after making drilled hole on pole for earth bolt & carriage upto 1.6 Km from store to work site in cluding filling up the the exacavated earth pit with shifted soil.(pwd page H-1, Item No-1) BI01010001010000000000000515BI0100001349 12 set
239 239 Painting the up to 9.00 m ST pole with two coats of aluminium paint of approved make over one coat of R.O primer incl preparation of surface by sand paper/emery incl cleaning etc. For receving fresh coat of paint.(Pwd page-h-2,Item no-4) 1st coat of aluminium paint over 1 coat of RO priming & 2nd coat of aluminium paint over 1st coat) BI01010001010000000000000515BI0100001350 12 item
240 240 Earthing the the Installation by 50 mm dia G.I. Pipe (ISI -M) 3.64 mtr long & 1x4 SWG G.I.(Hot dip) wire (4 mtr long) with suitable nuts, bolts & washer etc. Incl S/F 15 mm dia GI protection pipe (1 mtr long) to be filled with bitumen partly under ground level & partly under ground level driven to an depth of 3.65 mtr below the ground level. .(Pwd page-G 1 Item no.2(a) BI01010001010000000000000515BI0100001351 8 set
241 241 S & F earth busbar of galvanized (Hot Dip) MS flat 25mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required (Pwd page-G 2 Item no.4(a) BI01010001010000000000000515BI0100001352 3 mtr
242 242 S&F GI waterproof type looping cable box size 200x15x100 mm deep having 4 mm thick comprising of one 250 v 15 A kit-kat fuse unit, one NL on procelain insulator. One compression type brass cable gland for upto 2 core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machane screws etc. earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick. MS claps with bolts, nuts etc. including painting with anticorrosive paint(Pwd page-H 5 Item no.5) BI01010001010000000000000515BI0100001353 10 each
243 243 Fixing only outdoor / street light type light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting(Pwd page-C3 Item no.19)(10 nos for poles and 10 nos for buliding) BI01010001010000000000000515BI0100001354 22 each
244 244 Electrical work NON Scheduled item Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Brand approved by EIC) 4 x 35 sq mm BI01010001010000000000000515BI0100001355 50 mtr
245 245 Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Brand approved by EIC 4 x 16 sq mm BI01010001010000000000000515BI0100001356 40 mtr
246 246 Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Brand approved by EIC 2 x 6 sq mm BI01010001010000000000000515BI0100001357 220 mtr
247 247 Supply of Ceiling Fan(make Brand approved by EIC) complete with all acessaries copper flex wire. 1200mm sweep BI01010001010000000000000515BI0100001358 50 set
248 248 Supply of Ceiling Fan(make Brand approved by EIC) complete with all acessaries copper flex wire. 1400mm sweep fan BI01010001010000000000000515BI0100001359 8 set
249 249 Supply of the following Heavy duty Exhaust Fan mening good the damages make(make- EPC / Orinet ) 9" Exhaust fan(230 mm) BI01010001010000000000000515BI0100001360 17 set
250 250 Supply of the following Heavy duty Exhaust Fan mening good the damages make(make- EPC / Orinet ) 12" sweep exhaust fan(300 mm) BI01010001010000000000000515BI0100001361 2 set
251 251 S/F 9W LED Lamp (make -(make Brand approved by EIC) ) on batten light on round block on wall / ceiling BI01010001010000000000000515BI0100001362 10 set
252 252 Supply and delivery of LED recessed full open 2x2 Tile, glare free uniform illumination (make Brand approved by EIC) BI01010001010000000000000515BI0100001363 18 set
253 253 Supply of 1ft 7 watt sleek LED mirror light with Extruded aluminium body, PMMA diffuser giving glare free illumination & smooth light distribution, & pre-wired with high effiency electronic driver, System Lumens > 525, IP 20 or better(make Brand approved by EIC) BI01010001010000000000000515BI0100001364 13 set
254 254 Supply of 12 watt Round Surface LED flat Panel with Die Cast Aluminium Heat Sink, white PMMA diffuser for uniform light distribution, High efficiency driver and 2KV Surge Protection, IP 20, Class I(make Brand approved by EIC) BI01010001010000000000000515BI0100001365 36 set
255 255 Supply of 18 watt Round Surface LED flat Panel with Die Cast Aluminium Heat Sink, white PMMA diffuser for uniform light distribution, High efficiency driver and 2KV Surge Protection, IP 20, Class I(make Brand approved by EIC) BI01010001010000000000000515BI0100001366 68 set
256 256 Supply & fixing Bulk Head light fitting with LED lamp (make Brand approved by EIC) BI01010001010000000000000515BI0100001367 8 set
257 257 Supply and delivery of 4' single LED type tube light fitting complete with all acessaries directly on ceiling with HW round block & suitable size of MS fastener (make Brand approved by EIC) BI01010001010000000000000515BI0100001368 69 set
258 258 Supply and delivery of 4' twin LED type tube light fitting complete with all acessaries directly on ceiling with HW round block & suitable size of MS fastener (make Brand approved by EIC) BI01010001010000000000000515BI0100001369 5 set
259 259 New LED spot lighting and design configuration to ensure consistent colour point within a lighting application. Availabl in black and wite colour option in 5700k (make Brand approved by EIC) BI01010001010000000000000515BI0100001370 6 set
260 260 Gate lighting decorative post top 360 degree indirect light with IP 65 protection.Resistant to impact and corrosion. (make Brand approved by EIC) BI01010001010000000000000515BI0100001371 2 set
261 261 Supply and delivery of 72 W LED STREET LIGHT (make Brand approved by EIC) BI01010001010000000000000515BI0100001372 16 set
262 262 Supply and delivery of 45 W LED STREET LIGHT (make Brand approved by EIC) BI01010001010000000000000515BI0100001373 4 set
263 263 Graden light IP 66 prtection LED pressure die cast power coated housing with PC diffuser. BI01010001010000000000000515BI0100001374 4 set
264 264 Supply & fixing of 3 Phase kWh Trivector Meter Class 1 whole current meter Energy Meter (LT) (model ER300P Class 1 cat no-WR300BC7300) description (3Ph, 4W TVM 240 V 10 - 60A BM ) to be fixed on board (Office-1, Residence-1) BI01010001010000000000000515BI0100001375 1 nos
265 265 SUPPLY & INSTALLATION OF AC MACHINES Supplying 2.0 TR/6000 Kcal/hr High Wall 3 star rated Non inverter split unit.(free 3 mtr refrigerant piping) Make HITACHI, model number-RMZ324 HCDO Non Inverter R-32 with rotary type compressor with copper condensor , rated power supply 230/50/1 Volts/Hz/Phase.One complete set BI01010001010000000000000515BI0100001376 8 set
266 266 Supplying & erecting soft drawn copper pipe suitable for\nrefrigeration system having 22 SWG thickness and innerdia / size 22 mm complete per meter BI01010001010000000000000515BI0100001377 80 mtr
267 267 Supplying & errection Drainage Pipe per meter BI01010001010000000000000515BI0100001378 80 mtr
268 268 Supplying & errection Iron Stand per set. BI01010001010000000000000515BI0100001379 8 set
269 269 Supply & fixing 5Kg Capacity ABC stored pressure type Fire Extinguisher of approved make with discharge hose & nozzle on wall with suitable iron bracket. including all accessories of approved make. BI01010001010000000000000515BI0100001380 5 set
270 270 PUMP & MOTOR SET Supply of singal phase 240V 2Hp (1.5 Kw) open well monoblock submersible pump motor set suitable for U.g Resorvoir having overrall head of (12 mtr to 19 mtr & discharge capacity of (258 LPM to 132 LPM). The discharge outlet size will be 40mm (1.5" inch) (Make kirloskar / KSB / crompton) BI01010001010000000000000515BI0100001381 1 set
271 271 Supply & Fixing of control panel suitable for single -Phase 2 HP Submersible Pump motor set comprising of DOL starter, dual Ammeter & Voltmeter, indicator lamp to be fixed on wall incl making connection & necy. earthing attachment. (make Brand approved by EIC) BI01010001010000000000000515BI0100001382 1 set
272 272 Supply & Laying 3 core 2.5 sqmm flat submersible cable \n(Finolex)incl. 3/4" PVC HD PVC pipe through U.G. trench with necy Jointing materials incl. S/Laying PVC HD PVC pipe (Oriplast)\n BI01010001010000000000000515BI0100001383 120 mtr
273 273 Labour charger for testing & commissioning of the above pump-motor set along with starter BI01010001010000000000000515BI0100001384 1 item
274 274 LAN & CCTV\nSupply and installation of 9U Wall mounted Rack with cooling fan and other relevant accessories.)(make-Valrack/HCL/dlink) BI01010001010000000000000515BI0100001385 1 No
275 275 Supply of 24Port CAT 6 Patch Panel-1.5mm thickness with Black (RAL9005) color painted,Housing ABS, UL94(Dlink/Molex) BI01010001010000000000000515BI0100001386 1 No
276 276 UTP CAT 6 Patch Cord - 2M(Legrand/Molex/Dlink) BI01010001010000000000000515BI0100001387 50 Nos
277 277 UTP CAT 6 Patch Cord - 1M(Legrand/Molex/Dlink) BI01010001010000000000000515BI0100001388 50 Nos
278 278 Dual port Cat5 & cat6 utp information outlet with british-american style face plate (Molex/Batton/Dlink/schneider)(Molex/Batton/Dlink) BI01010001010000000000000515BI0100001389 50 Nos
279 279 Supply of 24 Port 10/1000 Ethernet switch(Dlink/Batton/Netgear) BI01010001010000000000000515BI0100001390 1 No
280 280 Supply of UPS - 600VA (APC/Microtek/Emerson) BI01010001010000000000000515BI0100001391 1 No
281 281 Supplying & Drawing LAN cable (CAT6) (Brand approved by\nEIC) in prelaid PVC rigid conduit/ in polythene pipe embeded\nin wall.(SOR, PWD, ELECTRICAL.2017; PAGE 63, ITEM-21) BI01010001010000000000000515BI0100001392 1500 Mtr
282 282 Supplying & Drawing 2-pair Telephone cables with high\ndensity polyethylene insulated solid annealed high conductivity\nbare copper of dia 0.5mm in prelaid PVC rigid conduit/ in\npolythene pipe embeded in wall.(SOR, PWD, ELECTRICAL.2017; PAGE 63, ITEM-23) BI01010001010000000000000515BI0100001393 1000 Mtr
283 283 Supply and laying of 5 Pair telephone cable through pvc conduit embeded in wall(25 mm dia, pvc conduit) BI01010001010000000000000515BI0100001394 500 Mtr
284 284 supply and fixing of 10 pair DB with original krone module-conceiled BI01010001010000000000000515BI0100001395 2 No
285 285 Supply Installation Testing Commissioning of 8 channel NVR-WITH POE(Hikvision/Honeywell/Bosch/Dahua ) BI01010001010000000000000515BI0100001396 1 No
286 286 Supply Installation Testing Commissioning of 2MP IP IR Dome Camera, Res: (1920 x 1080), 30M IR Range,Focal Length(mm) 3.6,Dual compressed stream,Image Sensor Type- CMOS;Image Sensor Size 0.357 inch; Day/Night Capable; IR illumination Range:(mtr) 30 Focal Length(mm) 2.8; UL certified\n(Honeywell/Bosch/Dahua/CPPlus/Hikvision ) BI01010001010000000000000515BI0100001397 2 No
287 287 Supply Installation Testing Commissioning of 2MP IR Bullet Camera-Image Sensor Type CMOS; Image Sensor Size -0.357 inch; Camera Image Sensing capacity : 2MP;\nResolution Full HD (1920 x 1080 Pixel) Day/Night Capable IR illumination Range(mtr) 30 Focal Length(mm) 3.6 Video Streaming Dual compressed stream; UL certified(Honeywell/Bosch/Dahua/Avigilion/HIKVISION ) BI01010001010000000000000515BI0100001398 2 No
288 288 Supply Installation Testing Commissioning of Surveillance Hard Disk 4 TB; Interface Type:SATA;Synchronous Transfer Rate (Maximum) (MB/s) :150 ;\nMake: WD/Seagate BI01010001010000000000000515BI0100001399 1 No
289 289 Supply Installation Testing Commissioning of 19" LED Monitor; Min Resolution: 1366 x 768; 200 nit.\nLG/Samsung BI01010001010000000000000515BI0100001400 1 No
290 290 Supply Installation Testing Commissioning of 6U Equiment Rack-loaded with necessary accessories\nvalrack/HCL BI01010001010000000000000515BI0100001401 1 No
291 291 Supply of 3 Core Power Cable (Min-1.5mm)\nFinolex/Molex/havells BI01010001010000000000000515BI0100001402 200 Mtr
292 292 Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make]\non wall, ceiling with saddles and other accessories as required\nand mending good damages to building works(20mm size)(SOR-2017; Page-60) BI01010001010000000000000515BI0100001403 1500 Mtr
293 293 Cable Laying , Fitting, Fixing, Termination & Installation, commissioning Charges(1Electrical and 1Electronic technician for 20 days)(CPWD SOR 2018: page-82 ) BI01010001010000000000000515BI0100001404 1 Job
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail