Military Engineer Services-MES has published Repair / Maintenance / Servicing Of Automatic Power Factor Correction Panels , Fixed Capacitor Panels And Allied Electric Works At Naval Base Kochi. Submission Date for this Tender is 08-02-2020. Electrification Work Tenders in Nava Base Kochi Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 24-Jan-2020 | critical_date | Date | 30-01-2020 |
2 | 31-Jan-2020 | critical_dates-1 | Date | 04-02-2020 |
3 | 05-Feb-2020 | Corrigendum_3 | Date | 08-02-2020 |
Name of Work : REPAIR / MAINTENANCE / SERVICING OF AUTOMATIC POWER FACTOR CORRECTION PANELS, FIXED CAPACITOR PANELS AND ALLIED ELECTRIC WORKS AT NAVAL BASE KOCHI | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | M & L Monthly General Servicing of Automatic Power Factor Correction (APFC) panel of capacity 100 kVAr comprising of heavy duty capacitors having low watt loss, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge. | 55 | Each Job | |
2 | 2 | M & L Monthly General Servicing of Automatic Power Factor Correction (APFC) panel of capacity 125 kVAr comprising of heavy duty capacitors having low watt loss, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge. | 88 | Each Job | |
3 | 3 | M & L Monthly General Servicing of Automatic Power Factor Correction (APFC) panel of capacity 250 kVAr comprising of heavy duty capacitors having low watt loss, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge. | 110 | Each Job | |
4 | 4 | M & L Monthly General Servicing of Automatic Power Factor Correction (APFC) panel of capacity 300 kVAr comprising of heavy duty capacitors having low watt loss, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge. | 33 | Each Job | |
5 | 5 | M & L Monthly General Servicing of Automatic Power Factor Correction (APFC) panel of capacity 375 kVAr comprising of heavy duty capacitors having low watt loss, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge. | 77 | Each Job | |
6 | 6 | M & L Monthly General Servicing of Automatic Power Factor Correction (APFC) panel of capacity 500 kVAr comprising of heavy duty capacitors having low watt loss, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge.\nNote for item No 1 to 6.\n(i) The quoted rate shall be deemed to include the cost of replacement of nut, bolt & washers, thimbles used while servicing the APFC panels or in any working time as directed by the Engr-in-charge.\n(ii) The quoted rate shall be deemed to include the cost of rent of the tools using.\n(iii) Spares for unserviceable components to be replaced shall be measured and paid separetely. \n(iv) If the contractor is failed to carried out the monthly servicing of the panel, a panality of double the quoted rate shall be recovered.\n(v) Contractor shall be ensured that the APFC panel functional through out the contract period and power factor reading shall not be fall under 0.95 PF.\n(vi) If any APFC panel found not functional or the power factor falls to 0.94 or low PF, a penal recovery of Rs.500.00 per day shall be recovered. In this connection, Accepting officer's decision shall be final.\n(vii) Contractor shall be submitted a monthly maintenance programme with location to the Engr-in-charge and the maintenance shall be carried put in the presence of JE / Engr-in-Charge without fail. | 33 | Each Job | |
7 | 7 | Supply only Heavy duty capacitors 3 to 25 kVAr, voltage 440 volt, 3 Phase, cylindrical, having operating losses 0.35 W/kVAr complete all as specified.\nMake L&T / MEHAR/Havells/C&S/ABB. | 500 | Per kVAr | |
8 | 8 | Supply only APFC relay, 4 Stage, auto set function, having digital display complete all as specified.\nMake L&T / BLR-CX/Havells/C&S/ABB | 8 | Each | |
9 | 9 | Supply only APFC relay, 6 Stage, auto set function, having digital display complete all as specified.\nMake L&T / BLR-CX/Havells/C&S/ABB | 8 | Each | |
10 | 10 | Supply only APFC relay, 8 Stage, auto set function, having digital display complete all as specified.\nMake L&T / BLR-CX/Havells/C&S/ABB | 5 | Each | |
11 | 11 | Supply only APFC relay, 12 Stage, auto set function, having digital display complete all as specified.\nMake L&T / BLR-CX/Havells/C&S/ABB | 2 | Each | |
12 | 12 | Supply only thyrister switching module, 440 volt, 50 Hz, having high peaking inverse voltage of 2.2 kV suitable for 10 kVAr rating complete all as specified.\nMake : L&T/Schnieder/ABB/Havells | 1 | Each | |
13 | 13 | Supply only thyrister switching module, 440 volt, 50 Hz, having high peaking inverse voltage of 2.2 kV suitable for 25 kVAr rating complete all as specified.\nMake : L&T/Schnieder/ABB/Havells | 2 | Each | |
14 | 14 | Supply only thyrister switching module, 440 volt, 50 Hz, having high peaking inverse voltage of 2.2 kV suitable for 50 kVAr rating complete all as specified.\nMake : L&T/Schnieder/ABB/Havells | 2 | Each | |
15 | 15 | Supply only capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO, suitable for upto 5 kVAr complete all as specified.\nMake : L&T/Schnieder/ABB/Havells/C&S | 10 | Each | |
16 | 16 | Supply only capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO, suitable for upto 12.5 kVAr complete all as specified.\nMake : L&T/Schnieder/ABB/Havells/C&S | 2 | Each | |
17 | 17 | Supply only capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO, suitable for kVAr rating upto 15 kVAr \nMake :L&T/Schnieder/ABB/Havells/C&S | 11 | Each | |
18 | 18 | Supply only capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO, suitable for kVAr rating upto 20 kVAr \nMake :L&T/Schnieder/ABB/Havells/C&S | 20 | Each | |
19 | 19 | Supply only capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO, suitable for kVAr rating upto 25 kVAr\nMake : L&T/Schnieder/ABB/Havells/C&S | 15 | Each | |
20 | 20 | Supply only capacitor duty contactor, 415 volt, 3 phase, 50 Hz, 1 NO, suitable for kVAr rating upto 50 kVAr \nMake : L&T/Schnieder/ABB/Havells/C&S | 15 | Each | |
21 | 21 | Supply only 3 pole contactor 70 Amp, type MNX 70, 415 volt, 3 phase, 50 Hz, 2 NO+2NC.\nMake : L&T/Schnieder/ABB/Havells/C&S | 6 | Each | |
22 | 22 | Supply only 3 pole contactor 110 Amp, type MNX 110, 415 volt, 3 phase, 50 Hz, 2 NO+2NC.\nMake : L&T/Schnieder/ABB/Havells/C&S | 6 | Each | |
23 | 23 | Supply only 3 pole contactor 140 Amp, type MNX 140, 415 volt, 3 phase, 50 Hz, 2 NO+2NC.\nMake : L&T/Schnieder/ABB/Havells/C&S | 6 | Each | |
24 | 24 | Supply only electronic time switch \nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 6 | Each | |
25 | 25 | Supply only side mounting Add-On block on auxiliary contact block suitable for MOC, 1NO+1NC\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 4 | Each | |
26 | 26 | Supply only HRC fuse, DIN type fuse links, 250 Amps \nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 4 | Each | |
27 | 27 | Supply only HRC fuse, DIN type fuse links, 160 Amps \nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 8 | Each | |
28 | 28 | Supply only HRC fuse, DIN type fuse links, 125 Amps \nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 6 | Each | |
29 | 29 | Supply only HRC fuse, DIN type fuse links, 80 Amps \nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 6 | Each | |
30 | 30 | Supply only Auto /Manual three position selector switch \nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 20 | Each | |
31 | 31 | Supply only LED indicator lamp (RED, YELLOW, GREEN)\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 75 | Each | |
32 | 32 | Supply only LED indicator lamp (AMBER, BLUE)\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 25 | Each | |
33 | 33 | Supply only push button actuator with carrier any colour.\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 12 | Each | |
34 | 34 | Supply only PVC Cooling fan for APFC panel 6" Sweep as per sample | 6 | Each | |
35 | 35 | Supply only 3 phase VAF+PF meter, 96 x 96 mm, flush mounting having accuracy 1.0, 5 Amp, 80-300V AC, \nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 8 | Each | |
36 | 36 | Supply only 3 phase Voltmeter, 96 x 96 mm, Flush mounting with inbuilt selector switch having accuracy Class 1.0.\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 8 | Each | |
37 | 37 | Supply only 3 ph Ammeter, 96 x 96 mm, Flush mounting with inbuilt selector switch having accuracy Class 1, 5Amp\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 8 | Each | |
38 | 38 | M & L Preparing the surfaces of APFC Panel, thoroughly cleaning the surface to remove dirt, grease, oil stains and applying two coats of synthetic enamel paint to APFC panel using spray gun after isolating the electric supply including re-connection of electric supply complete all as specified and directed by Engineer-in-Charge. | 400 | Sqm | |
39 | 39 | S & F MCCB, 3 Pole, 800 Amps, 415 Volts, having breaking capacity 50 kA, thermal-magnetic release, isolation funtion, roto active double break mechanism, Ics = 100% Icu including taking down old MCCB complete all as specified.\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 1 | Each | |
40 | 40 | S & F MCCB, 3 Pole, 630 Amps, 415 Volts, having breaking capacity 50 kA, thermal-magnetic release, isolation funtion, roto active double break mechanism, Ics = 100% Icu including taking down old MCCB complete all as specified.\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 2 | Each | |
41 | 41 | S & F MCCB, 3 Pole, 400 Amps, 415 Volts, having breaking capacity 50 kA, thermal-magnetic release, isolation funtion, roto active double break mechanism, Ics = 100% Icu including taking down old MCCB complete all as specified.\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 5 | Each | |
42 | 42 | S & F MCCB, 3 Pole, 250 Amps, 415 Volts, having breaking capacity 36 kA, thermal-magnetic release, isolation funtion, roto active double break mechanism, Ics = 100% Icu including taking down old MCCB complete all as specified.\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 5 | Each | |
43 | 43 | S & F MCCB, 3 Pole, 200 Amps, 415 Volts, having breaking capacity 36 kA, thermal-magnetic release, isolation funtion, roto active double break mechanism, Ics = 100% Icu including taking down old MCCB complete all as specified.\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 5 | Each | |
44 | 44 | S & F MCCB, 3 Pole, 160 Amps, 415 Volts, having breaking capacity 36 kA, thermal-magnetic release, isolation funtion, roto active double break mechanism, Ics = 100% Icu including taking down old MCCB complete all as specified.\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 10 | Each | |
45 | 45 | S & F MCCB, 3 Pole, 125 Amps, 415 Volts, having breaking capacity 36 kA, thermal-magnetic release, isolation funtion, roto active double break mechanism, Ics = 100% Icu including taking down old MCCB complete all as specified.\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 10 | Each | |
46 | 46 | S & F MCCB, 3 Pole, 63/80/100 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, isolation funtion, roto active double break mechanism, Ics = 100% Icu including taking down old MCCB complete all as specified.\nMake : L&T/Legrand/GIC/C&S/ABB/HPL | 20 | Each | |
47 | 47 | M&L Sub main wiring on wall/ceiling with 2 runs of 2.5 Sqmm single core PVC cable as per IS 694-1990(third revision) insulated unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including surface PVC conduit pipe of medium grade with all accessories such as Tees, elbows, junction box etc.as required of not less than 25mm dia and 1 run of 2.5 Sqmm single core PVC insulated unsheathed 1100 Volts grade, multistranded copper conductor FRLS cable as earth continuity conductor and connecting to existing earth dolly with suitable size thimble and making good the disturbed surface to match with the existing including taking down of old sub main wiring complete all as specified. \nNote : 3 runs of 2.5 Sqmm wire and one run of PVC conduit with accesories shall be measured as one unit. | 25 | RM | |
48 | 48 | M&L Sub main wiring on wall/ceiling with 2 runs of 4.0 Sqmm single core PVC cable as per IS 694-1990(third revision) insulated unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including surface PVC conduit pipe of medium grade with all accessories such as Tees, elbows, junction box etc.as required of not less than 25mm dia and 1 run of 4.0 Sqmm single core PVC insulated unsheathed 1100 Volts grade, multistranded copper conductor FRLS cable as earth continuity conductor and connecting to existing earth dolly with suitable size thimble and making good the disturbed surface to match with the existing including taking down of old sub main wiring complete all as specified. \nNote : 3 runs of 4.0 Sqmm wire and one run of PVC conduit with accesories shall be measured as one unit. | 25 | RM | |
49 | 49 | M&L Sub main wiring on wall/ceiling with 2 runs of 6.0 Sqmm single core PVC cable as per IS 694-1990(third revision) insulated unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including surface PVC conduit pipe of medium grade with all accessories such as Tees, elbows, junction box etc.as required of not less than 25mm dia and 1 run of 6.0 Sqmm single core PVC insulated unsheathed 1100 Volts grade, multistranded copper conductor FRLS cable as earth continuity conductor and connecting to existing earth dolly with suitable size thimble and making good the disturbed surface to match with the existing including taking down of old sub main wiring complete all as specified. \nNote : 3 runs of 6.0 Sqmm wire and one run of PVC conduit with accesories shall be measured as one unit. | 25 | RM | |
50 | 50 | S & F in repair MCB, DP, 0.5 to 4 Amps, 240 Volt, C curve, having breaking capacity 10 kA, complete all as specified.\nMake : L&T / ABB / SIEMENS / C&S / HPL | 6 | Each | |
51 | 51 | S & F in repair MCB, DP, 6 to 32 Amps, 240 Volt, C curve, having breaking capacity 10 kA, complete all as specified.\nMake : L&T / ABB / SIEMENS / C&S / HPL | 6 | Each | |
52 | 52 | S & F in repair MCB, DP, 40 to 63 Amps, 240 Volt, C curve, having breaking capacity 10 kA, complete all as specified.\nMake : L&T / ABB / SIEMENS / C&S / HPL | 4 | Each | |
53 | 53 | S & F in repair MCB, TP, 0.5 to 4 Amps, 240 Volt, C curve, having breaking capacity 10 kA, complete all as specified.\nMake : L&T / ABB / SIEMENS / C&S / HPL | 4 | Each | |
54 | 54 | S & F in repair MCB, TP, 6 to 32 Amps, 240 Volt, C curve, having breaking capacity 10 kA, complete all as specified.\nMake : L&T / ABB / SIEMENS / C&S / HPL | 3 | Each | |
55 | 55 | S & F in repair MCB, TP, 40 to 63 Amps, 240 Volt, C curve, having breaking capacity 10 kA, complete all as specified.\nMake : L&T / ABB / SIEMENS / C&S / HPL | 6 | Each | |
56 | 56 | S & F in repair MCB, FP, 40 to 63 Amps, 240 Volt, C curve, having breaking capacity 10 kA, complete all as specified.\nMake : L&T / ABB / SIEMENS / C&S / HPL | 6 | Each | |
57 | 57 | M & L Earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to galvanized earth strip 32X6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer nuetral/body/ LT panel etc. and testing on completion, including taking old unserviceable earth plate complete all as directed. | 10 | Each | |
58 | 58 | M & L 32x6mm size Galvanised iron strip as Earth continuity conductor or main earthing strip fixed to wall or recess or chases or buried in ground including drawn through 40mm GI pipe or any other indicated situation etc as required, all joints shall be properly welded including taking down old unserviceable earth continuity conductor complete all as specified. | 50 | RM | |
59 | 59 | Supply only MPP heavy duty capacitors 5 to 15 kVAr, 440 volt, 3 phase, box type, resin filled having operating losses 0.35 W/kVAr, complete all as specified.\nMake : L&T/ABB/C&S | 150 | Per kVAr | |
60 | 60 | Supply only MPP heavy duty capacitors 20 to 50 kVAr, 440 volt, 3 phase, box type, resin filled having operating losses 0.35 W/kVAr, complete all as specified.\nMake : L&T/ABB/C&S | 650 | Per kVAr | |
61 | 61 | Shifting of APFC panels / LT panels of any capacity from one substation to another substation by using necessary vehicle, crane, men power etc \nNote :- \n(a) Contractor shall take care of the equipment while shifting, if any damage found shall be rectified at his own risk.\n(ii) The rate quoted shall deem to include the labour charge for disconnecting / connecting the panels. | 4 | Each Job | |
62 | 62 | M & L Servicing of LT fixed cpacitor panel of any capacity by replacing unserviceable capacitor, MCCB, checking of each component, tightening of all connections, including replacement of unserviceable parts, thimbles, nut, bolt & washers etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge.\nNote :- MCCB, MCB and capacitor if replaced, shall be measured and paid seperately as supply only. | 10 | Each Job | |
63 | 63 | Supply and fix in replacement 25 sqmm, fibre glass insulated flexible copper cable duly varnished class 'F' single core complete all as specified. | 50 | RM | |
64 | 64 | Supply and fixing in replacement 2 core, 2.5 sqmm, flexible copper cable, multistranded, 1100 volt grade as per IS 694 : 1990, including necessary tags, clips, etc complete all as specified. | 50 | RM | |
65 | 65 | Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors,1100 volts grade of of size 185 Sqmm 3.5 core including necessary glands, lugs, nuts and bolts after fitting to to required length as per site requirement including taking down old unserviceable cable complete all as specified. | 100 | RM | |
66 | 66 | Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors,1100 volts grade of of size 240 Sqmm 3.5 core including necessary glands, lugs, nuts and bolts after fitting to to required length as per site requirement including taking down old unserviceable cable complete all as specified. | 100 | RM | |
67 | 67 | Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors,1100 volts grade of of size 300 Sqmm 3.5 core including necessary glands, lugs, nuts and bolts after fitting to to required length as per site requirement including taking down old unserviceable cable complete all as specified. | 100 | RM | |
68 | 68 | Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors,1100 volts grade of of size 400 Sqmm 3.5 core including necessary glands, lugs, nuts and bolts after fitting to to required length as per site requirement including taking down old unserviceable cable complete all as specified. | 100 | RM | |
69 | 69 | Supply, install, testing and commissioning of indoor panel with 40 mm x 40 mm x 5mm angle iron Pedestal suitable for APFC 150 kVAR, 6 step (2X5+3x25+1 x 50) (One 15 kVAR capacitor should be directly connected), having IP42 protection, auto switching, indoor, bottom cable entry floor mounted including one set Phase indicating lamp and one No Digital VAF meter and all necessary control wiring with space for Heavy duty MPP capacitor non compartmentalised, space for suitable APFC relay and space for MCCBs and capacitor duty contactors etc . The Panel shall be made up of 2mm thick CRCA steel sheet, powder coated as per RAL 7032 with , CTs, digital meters, phase indicating lamp, suitable aluminium bus bar with support and provision for cooling fan, overload and short circuit protection and space for suitable rated relay complete all as specified.\nNote:- MCCBs, capacitors, Contactors, timers and cooling fans will be paid seperately. | 2 | Each | |
70 | 70 | S & F CT 1000/5 Amp, insulated, class 1.0 \nMake : PGR/C&S/HCL/AE/ | 3 | Each | |
71 | 71 | S & F CT 800/5 Amp, insulated, class 1.0 \nMake : PGR/C&S/HCL/AE/ | 3 | Each | |
72 | 72 | S & F CT 500/5 Amp, insulated, class 1.0 \nMake : PGR/C&S/HCL/AE/ | 6 | Each | |
73 | 73 | S & F CT 400/5 Amp, insulated, class 1.0 \nMake : PGR/C&S/HCL/AE/ | 10 | Each | |
74 | 74 | S & F CT 200/5 Amp, insulated, class 1.0 \nMake : PGR/C&S/HCL/AE/ | 7 | Each | |
75 | 75 | S & F CT 100/5 Amp, insulated, class 1.0 \nMake : PGR/C&S/HCL/AE/ | 8 | Each | |
76 | 76 | S & F in repair ACB, 3 pole,1600 Amp, manual fixed type having breaking capacity 50 kA, microprocessor release, 415 volt AC at 50 Hz with inbuilt 2NO+2NC aux contact complete all specified.\nMake: Siemens / ABB / C&S / L&T | 1 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail