Repair/Maintenance Of Lt Cable , Lt Panel Board And Connected Items In Domestic Area At Af Stn Phalodi, PHALODI-Rajasthan

Military Engineer Services-MES has published Repair/Maintenance Of Lt Cable , Lt Panel Board And Connected Items In Domestic Area At Af Stn Phalodi. Submission Date for this Tender is 11-02-2020. Bolts Tenders in PHALODI Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

23227175
Corrigendum : Repair/Maintenance Of Lt Cable , Lt Panel Board And Connected Items In Domestic Area At Af Stn Phalodi
Open Tender
Indian
Rajasthan
PHALODI
11-02-2020

Tender Details

Repair / Maintenance Of Lt Cable , Lt Panel Board And Connected Items In Domestic Area At Af Stn Phalodi -1 Excavation In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth Or N Exc 10 Sqm On Plan And N Exc 1.5 M In Depth & Getting Out, For Pole Foundation, Etc. Or For Laying Underground Cable, Pipe Lines Etc. In Soft / Loose Soil, Complete All As Specified & Directed. 2 Excavation In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth Or N Exc 10 Sqm On Plan And N Exc 1.5 M In Depth & Getting Out, For Pole Foundation, Etc. Or For Laying Underground Cable, Pipe Lines Etc. In Hard / Dense Soil, Complete All As Specified & Directed. 3 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cms Thick In Soft / Loose Or Hard Dense Soil Complete All As Specified And Directed. 4 Removing Excavated Surplus Material To A Distance Not Exceeding 50 Mtr And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And Directed. 5 Cutting Of Road / Hardstanding Upto A Size Not Exceeding 20 Cm In Width And Not Exceeding 60 Cm In Depth For Laying Of Lt Ug Cable Protection Pipe Line, Making Good The Disturbed Portion So As To Match Existing Finishing Or With Pcc 1:2:4 Type B1 Complete All As Specified And Directed. 6 Laying Only, Connecting, Testing, Commisioning And Jointing Xlpe Insulated, Armoured, Heavy Duty Electric Power Cables With Stranded Aluminum Conductors, 1100 Volts Grade, Laid In Trenches, Ducts, Pipes, Drawn Across The Roads / Paths / Drains / Along Poles / Walls / Floors / Equipment Etc Including Jointing Materials And Including Disconnecting & Taking Out Old Unserviceable Lt Ug Cables Of Any Size / Type Complete All As Specified And Directed For Following Cross Sectional Areas Of Cables :- Nnotes For Srl Item Nos. 6.10 To 6.40 :- ( I ) Lt Ug Xlpe Cables Will Be Issued Under Sch B Free For Laying / Fixing Only. N ( Ii ) Excavation, Earth Work, Sand Cushioning, Cable Protection Cover & Gi Pipes Shall Be Measured And Paid For Separately Under Respective Items Of Boq. 7 Cross Sectional Area Of Cable 120 Sqmm, 3.5 Core 8 Cross Sectional Area Of Cable 150 Sqmm, 3.5 Core 9 Cross Sectional Area Of Cable 185 Sqmm, 3.5 Core 10 Cross Sectional Area Of Cable 240 Sqmm, 3.5 Core 11 Supplying, Laying, Jointing, Testing And Commisioning Xlpe Insulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Power Cable ( Heavy Duty ) With Multistranded Aluminum Conductors, 1100 Volt Grade, Laid In Trenches / Ducts / Encased In Gi Pipe / Fixed To Pole / Wall With Necessary Angle Iron Support, Clamp, Nut , Bolts Etc And Including Taking Down Old Unserviceable Cables Complete All As Specified And Directed For Following Cross Sectional Areas Of Cables :- Nnotes For Srl Item Nos. 7.10 To 7.50 :- Excavation, Earth Work, Sand Cushioning, Cable Protection Cover & Gi Pipes Shall Be Measured And Paid For Separately Under Respective Items Of Boq. 12 Cross Sectional Area Of Cable 16 Sqmm, 4 Core 13 Cross Sectional Area Of Cable 25 Sqmm, 3.5 Core 14 Cross Sectional Area Of Cable 35 Sqmm, 3.5 Core 15 Cross Sectional Area Of Cable 50 Sqmm, 3.5 Core 16 Cross Sectional Area Of Cable 95 Sqmm, 3.5 Core 17 M & L For Dry Tibba Sand Cushioning To Pvc Under Ground Cable With Screened And Washed Sand And Punning To Provide A Required Cover To Cable All As Per Standard Schedule Rates Part-I ( 2009 ) Complete All As Specified And Directed. Nnote:- Thickness After Punning Shall Be Considered For Payment. 18 Supplying And Laying In Renewal For Un-Reinforced Precast Cement Concrete Cable Cover, Class Lv, Type-2, Flat, Size 300 Mm X 180Mm X 40Mm Laid Dry And Abuting Each Other With Gap Between Adjecent Cover Not Exceeding 10Mm Over Ug Cable For Protection Complete All As Specified And Directed. 19 Demolition Of Cement Concrete ( Un-Reinforced ) Of Any Description And In Any Position Not Otherwise Specifically Provided As Coping To Poles, Flood Lights, Tarmac Light, Foundation Etc Complete All As Specified And Directed. 20 M & L For Cement Concrete Pcc 1:4:8 Type D-2 Using 40Mm Graded Crushed Stone Aggregate As In Pole Foundation And Like Complete All As Specified And Directed. 21 S & F In Renewal Of Aluminium Cable Lugs Complete All As Specified And Directed Of The Following Sizes :- Nmake : Dowells / Jainson Or Equivalent. 22 25 Sqmm Size 23 35 Sqmm Size 24 50 Sqmm Size 25 70 Sqmm Size 26 95 Sqmm Size 27 120 Sqmm Size 28 150 Sqmm Size 29 185 Sqmm Size 30 240 Sqmm Size 31 300 Sqmm Size 32 S & F In Renewal Of Aluminium Crimping Connectors Complete All As Specified And Directed Of The Following Sizes :- Nmake : Dowells / Jainson Or Equivalent. 33 25 Sqmm Size 34 35 Sqmm Size 35 50 Sqmm Size 36 70 Sqmm Size 37 95 Sqmm Size 38 120 Sqmm Size 39 150 Sqmm Size 40 185 Sqmm Size 41 240 Sqmm Size 42 300 Sqmm Size 43 M & L For Preparation Of Old Painted Steel Surfaces Of Any Description Over 10 Cm Width Or Girth By Scrubbing The Existing Painted Surfaces And Applying Two Coats Of Synthetic Enamel Paint Over And Including A Coat Of Red Oxide Primer For Lt Panel Board / Feeder Pillar Box Of Any Size And Shape Complete All As Specified And Directed. 44 S & F In Renewal For Mccb, Four Pole, 415 Volts, 63 Amp, Ultimate Breaking Capacity 16 Ka, Ics = 75% Lcu ( Icu = 16 Ka ) , 50 Hz, Ac And Confirming To Iec: 60947- Ii / Is - 13947-Ii With Adjustable Thermal And Adjustable Magnetic Setting, Complete All As Specified And Directed. 45 S & F In Renewal For Mccb, Four Pole, 415 Volts, 125 Amp, Ultimate Breaking Capacity 16 Ka, Ics = 75% Lcu ( Icu = 16 Ka ) , 50 Hz, Ac And Confirming To Iec: 60947- Ii / Is - 13947-Ii With Adjustable Thermal And Adjustable Magnetic Setting, Complete All As Specified And Directed. 46 S & F In Renewal For Mccb, Four Pole, 415 Volts, 160 Amp, Ultimate Breaking Capacity 25 Ka, Ics = 75% Lcu ( Icu = 25 Ka ) , 50 Hz, Ac And Confirming To Iec: 60947- Ii / Is - 13947-Ii With Adjustable Thermal And Adjustable Magnetic Setting, Complete All As Specified And Directed. 47 S & F In Renewal For Mccb, Four Pole, 415 Volts, 200 Amp, Ultimate Breaking Capacity 36 Ka, Ics = 75% Lcu ( Icu = 36 Ka ) , 50 Hz, Ac And Confirming To Iec: 60947- Ii / Is - 13947-Ii With Adjustable Thermal And Adjustable Magnetic Setting, Complete All As Specified And Directed. 48 S & F In Renewal For Mccb, Four Pole, 415 Volts, 250 Amp, Ultimate Breaking Capacity 36 Ka, Ics = 75% Lcu ( Icu = 36 Ka ) , 50 Hz, Ac And Confirming To Iec: 60947- Ii / Is - 13947-Ii With Adjustable Thermal And Adjustable Magnetic Setting, Complete All As Specified And Directed. 49 S & F In Renewal For Mccb, Four Pole, 415 Volts, 315 Amp, Ultimate Breaking Capacity 36 Ka, Ics = 75% Lcu ( Icu = 36 Ka ) , 50 Hz, Ac And Confirming To Iec: 60947- Ii / Is - 13947-Ii With Adjustable Thermal And Adjustable Magnetic Setting, Complete All As Specified And Directed. 50 S & F In Renewal For Mccb, Four Pole, 415 Volts, 630 Amp, Ultimate Breaking Capacity 50 Ka, Ics = 75% Lcu ( Icu = 50 Ka ) , 50 Hz, Ac And Confirming To Iec: 60947- Ii / Is - 13947-Ii With Adjustable Thermal And Adjustable Magnetic Setting, Complete All As Specified And Directed. 51 S & F In Renewal Of Volt Meter 0-500 Volt, Digital Type Of Size 96Mm X 96 Mm Square, Flush Mounted Type Having Lamp Accuracy Glass --1 Complete All As Specified And Directed. Nmake :- Ae / Enercon / Imp / Hpl / Havells. 52 S & F In Renewal Of Ammeter 0-200 Amp, Digital Type Of Size 96Mm X 96 Mm Square, Flush Mounted Type Having Lamp Accuracy Glass --1 Complete All As Specified And Directed. Nmake :- Ae / Enercon / Imp / Hpl / Havells. 53 S & F In Renewal Of Current Transformer ( Ct ) Coil Suitable For Ampere Meter 100 / 5 Amp Complete All As Specified And Directed. Nmake :- Ae / Enercon / Epcos. 54 M & L For Renewal To Outdoor / Indoor Type Feeder Pillar Box Of Any Capacity / Size By Replacing Pitted Portion Not Exc 1 Sqm With As Per Existing / Suitable Gauge Of Ms Sheet, Cutting To Shape, Welding Work, Renewal Of Unserviceable Door Hinges And Locking Arrangement, Necessary Electrical Connections Etc And Incl Painting With Two Coats Of Synthetic Enamel Paint Over And Incl A Coat Of Red Oxide Primer Complete All As Specified And Directed. 55 S & F In Renewal Of Indicating Lamp Set Ryb For Phase Indication Operating On 240 Volt, 50 Hz, Ac With New One Led Panel, Mounting Type To Match Existing One Complete All As Specified And Directed. Nmake :- L&T / C&S / Abb. 56 Supply, Installation, Testing & Commissioning Of Factory Made Lt Panel Of Size 1200Mm X 800Mm X 450Mm, Outdoor Type, ( Kiosk ) Cpri Approved, Cubical Type, Floor Mounted, Powder Coated Made Of 3.15Mm Thick Ms Sheet Dust And Vermin Proof, Protection Class Ip 65 With 300 Amps Aluminium Bus Bars, Front & Back Opened With Locking Door With Hinges, Arrangements Lt Panel Mounted On Angle Iron ( 40X40x6mm ) Frame Work, Powder Coated Finish With Two Coats Sythetic Enameled Paint Over And Including A Coat Of Red Oxide Primer, Front & Rear Opening Type, With Aprons For Cable Entry, With Double Door Shutter And Locking Arrangement ( Including Provn Of 65Mm Godrej ( Freedom ) Lock With 2 Keys, Internal Wiring With Pvc Insulated, Multistranded Copper Conductor, Frls Cables, Is-694 Marked Of Adequate Size But Not Less Than 4 Sqmm And Base Frame With Legs Grouted In Suitable Pcc ( 1:2:4 ) Type B1 Block Upto 45Cm In Ground & 45 Cm Height From Ground Level & Including Taking Down Old Unserviceable Existing Lt Panel Of Any Type / Size & New Panel Comprising Of The Following Accessories Complete All As Specified And Directed :- Nincoming :- N ( A ) Mccb, Four Pole, 200 Amp, 415 Volts, Ac, 50 Hz, 25 Ka, Ics=100 %Icu, Fixed Thermal & Fixed Megnetic – 02 Nos. ( 01 Spare ) Nout Going :- N ( A ) Mccb, Four Pole, 100 Amp, 415 Volts, Ac, 50 Hz, 16 Ka, Ics=100 %Icu, Fixed Thermal & Fixed Megnetic – 05 Nos ( 01 Spare ) . N ( B ) Amp Meter Digital Type With Selector Switch ( 0-250 Amp ) - 01 No. N ( C ) Volt Meter Digital Type With Selector Switch ( 0-500 Volts ) - 01 No N ( D ) Led Indicator ( Ryb ) - 01 Set. Nnote :- The Cost Of Earth Work, Platform / Foundation With Pcc Shall Deemed To Be Included In The Quoted Rates.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Feb-2020 Date Corrigendum Date 11-02-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 38400.0 /-
Tender Value
INR 19.20 Lakhs /-
Disclaimer :