}

Rate Contract For Pressure Testing And Vacuum Testing Of Ac And Ref Plants In Vessels Rate Contract For Pressure Testing And Vacuum Testing Of Ac And Ref Plants In Vessels, NAVAL DOCKYARD VISAKHAPATNAM-Andhra Pradesh

Indian Navy-IN has published Rate Contract For Pressure Testing And Vacuum Testing Of Ac And Ref Plants In Vessels Rate Contract For Pressure Testing And Vacuum Testing Of Ac And Ref Plants In Vessels. Submission Date for this Tender is 06-02-2020. Gaskets Tenders in NAVAL DOCKYARD VISAKHAPATNAM Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

23202443
Rate Contract For Pressure Testing And Vacuum Testing Of Ac And Ref Plants In Vessels Rate Contract For Pressure Testing And Vacuum Testing Of Ac And Ref Plants In Vessels
Open Tender
Indian
Andhra Pradesh
NAVAL DOCKYARD VISAKHAPATNAM
06-02-2020

Tender Details

Rate Contract For Pressure Testing And Vacuum Testing Of Ac And Ref Plants In Vessels Rate Contract For Pressure Testing And Vacuum Testing Of Ac And Ref PlantsIn Vessels , Compressor ( Snf-Ac Plant ) : ( A ) Undertake Alignment Of Compressor With Motor Using Laser Tool . ( B ) Undertake Pt Of Compressor Per 24 Hours After Leak Rectification ( C ) Undertake Vt Of Compressor As Per Main Top . , Compressor ( Snf-Ref Plant ) : ( A ) Undertake Alignment Of Compressor With Motor Using Laser Tool . ( B ) Undertake Pt Of Compressor Per 24 Hours After Leak Rectification ( C ) Undertake Vt Of Compressor As Per Main Top . , Condenser ( Snf-Ac Plant ) : ( A ) Pressure Shell Side With Nitrogen After Removing End Cover And Pipe Lines . ( B ) Undertake Leak Test With Soap Solution . ( C ) Repair Leaking Tubes Relief Valves . ( D ) Undertake Pt For 24 Hours . , Condenser ( Snf-Ref Plant ) : ( A ) Pressure Shell Side With Nitrogen After Removing End Cover And Pipe Lines . ( B ) Undertake Leak Test With Soap Solution . ( C ) Repair Leaking Tubes Relief Valves . ( D ) Undertake Pt For 24 Hours . , Chiller ( Snf-Ac Plant ) : ( A ) Pressure Shell Side With Nitrogen After Removing End Cover And Pipe Lines . ( B ) Undertake Leak Test With Soap Solution . ( C ) Repair Leaking Tubes Relief Valves . ( D ) Undertake Pt For 24 Hours . , Chiller ( Snf - Ref Plant ) : ( A ) Pressure Shell Side With Nitrogen After Removing End Cover And Pipe Lines . ( B ) Undertake Leak Test With Soap Solution . ( C ) Repair Leaking Tubes Relief Valves . ( D ) Undertake Pt For 24 Hours . , Ots/ Oil Separator/ Receiver ( Snf - Ac Plant ) : Close Valves , Pressurize The Container With Nitrogen , Spot The Leak With Soap Solution , Release The Nitrogen , Rectify The Leak By Insitu Welding . , Ots/ Oil Separator/ Receiver ( Snf -Ref Plant ) : Close Valves , Pressurize The Container With Nitrogen , Spot The Leak With Soap Solution , Release The Nitrogen , Rectify The Leak By Insitu Welding . , Gas Line System ( Snf - Ac Plant ) : ( A ) Pressurize The System With Nitrogen As Maintops . ( B ) Identify And Repair Leakage By Brazing/ Welding/ Gasket Renewal Etc . ( C ) Replace Gauge Line Of Leakage . ( D ) Proove Pt Of Complete System . , Gas Line System ( Snf - Ref Plant ) : ( A ) Pressurize The System With Nitrogen As Maintops . ( B ) Identify And Repair Leakage By Brazing/ Welding/ Gasket Renewal Etc . ( C ) Replace Gauge Line Of Leakage . ( D ) Proove Pt Of Complete System . , Vacuum Test ( Snf - Ac Plant ) : Vacuum Is To Be Raised And Proved For A Period Of 24 Hours , Vacuum Test ( Snf - Ref Plant ) : Vacuum Is To Be Raised And Proved For A Period Of 24 Hours , Compressor ( P17-Ac Plant ) : ( A ) Undertake Alignment Of Compressor With Motor Using Laser Tool . ( B ) Undertake Pt Of Compressor Per 24 Hours After Leak Rectification ( C ) Undertake Vt Of Compressor As Per Main Top . , Compressor ( P17-Ref Plant ) : ( A ) Undertake Alignment Of Compressor With Motor Using Laser Tool . ( B ) Undertake Pt Of Compressor Per 24 Hours After Leak Rectification ( C ) Undertake Vt Of Compressor As Per Main Top . , Condenser ( P17-Ac Plant ) : ( A ) Pressure Shell Side With Nitrogen After Removing End Cover And Pipe Lines . ( B ) Undertake Leak Test With Soap Solution . ( C ) Repair Leaking Tubes Relief Valves . ( D ) Undertake Pt For 24 Hours . , Condenser ( P17-Ref Plant ) : ( A ) Pressure Shell Side With Nitrogen After Removing End Cover And Pipe Lines . ( B ) Undertake Leak Test With Soap Solution . ( C ) Repair Leaking Tubes Relief Valves . ( D ) Undertake Pt For 24 Hours . , Chiller ( P17-Ac Plant ) : ( A ) Pressure Shell Side With Nitrogen After Removing End Cover And Pipe Lines . ( B ) Undertake Leak Test With Soap Solution . ( C ) Repair Leaking Tubes Relief Valves . ( D ) Undertake Pt For 24 Hours . , Chiller ( P17-Ref Plant ) : ( A ) Pressure Shell Side With Nitrogen After Removing End Cover And Pipe Lines . ( B ) Undertake Leak Test With Soap Solution . ( C ) Repair Leaking Tubes Relief Valves . ( D ) Undertake Pt For 24 Hours . , Ots/ Oil Separator/ Receiver ( P17 - Ac Plant ) : Close Valves , Pressurize The Container With Nitrogen , Spot The Leak With Soap Solution , Release The Nitrogen , Rectify The Leak By Insitu Welding . , Ots/ Oil Separator/ Receiver ( P17 -Ref Plant ) : Close Valves , Pressurize The Container With Nitrogen , Spot The Leak With Soap Solution , Release The Nitrogen , Rectify The Leak By Insitu Welding . , Gas Line System ( P17- Ac Plant ) : ( A ) Pressurize The System With Nitrogen As Maintops . ( B ) Identify And Repair Leakage By Brazing/ Welding/ Gasket Renewal Etc . ( C ) Replace Gauge Line Of Leakage . ( D ) Proove Pt Of Complete System . , Gas Line System ( P17- Ref Plant ) : ( A ) Pressurize The System With Nitrogen As Maintops . ( B ) Identify And Repair Leakage By Brazing/ Welding/ Gasket Renewal Etc . ( C ) Replace Gauge Line Of Leakage . ( D ) Proove Pt Of Complete System . , Vacuum Test ( P17- Ac Plant ) : Vacuum Is To Be Raised And Proved For A Period Of 24 Hours . , Vacuum Test ( P17- Ref Plant ) : Vacuum Is To Be Raised And Proved For A Period Of 24 Hours . , Compressor ( P25/P25a -Ac Plant ) : ( A ) Undertake Alignment Of Compressor With Motor Using Laser Tool . ( B ) Undertake Pt Of Compressor Per 24 Hours After Leak Rectification ( C ) Undertake Vt Of Compressor As Per Main Top . , Compressor ( P25/P25a -Ref Plant ) : ( A ) Undertake Alignment Of Compressor With Motor Using Laser Tool . ( B ) Undertake Pt Of Compressor Per 24 Hours After Leak Rectification ( C ) Undertake Vt Of Compressor As Per Main Top . , Condenser ( P25/P25a -Ac Plant ) : ( A ) Pressure Shell Side With Nitrogen After Removing End Cover And Pipe Lines . ( B ) Undertake Leak Test With Soap Solution . ( C ) Repair Leaking Tubes Relief Valves . ( D ) Undertake Pt For 24 Hours . , Condenser ( P25/P25a -Ref Plant ) : ( A ) Pressure Shell Side With Nitrogen After Removing End Cover And Pipe Lines . ( B ) Undertake Leak Test With Soap Solution . ( C ) Repair Leaking Tubes Relief Valves . ( D ) Undertake Pt For 24 Hours . , Chiller ( P25/P25a -Ac Plant ) : ( A ) Pressure Shell Side With Nitrogen After Removing End Cover And Pipe Lines . ( B ) Undertake Leak Test With Soap Solution . ( C ) Repair Leaking Tubes Relief Valves . ( D ) Undertake Pt For 24 Hours . , Chiller ( P25/P25a -Ref Plant ) : ( A ) Pressure Shell Side With Nitrogen After Removing End Cover And Pipe Lines . ( B ) Undertake Leak Test With Soap Solution . ( C ) Repair Leaking Tubes Relief Valves . ( D ) Undertake Pt For 24 Hours . , Ots/ Oil Separator/ Receiver ( P25/P25a -Ac Plant ) : Close Valves , Pressurize The Container With Nitrogen , Spot The Leak With Soap Solution , Release The Nitrogen , Rectify The Leak By Insitu Welding . , Ots/ Oil Separator/ Receiver ( P25/P25a -Ref Plant ) : Close Valves , Pressurize The Container With Nitrogen , Spot The Leak With Soap Solution , Release The Nitrogen , Rectify The Leak By Insitu Welding . , Gas Line System ( P25/P25a -Ac Plant ) : ( A ) Pressurize The System With Nitrogen As Maintops . ( B ) Identify And Repair Leakage By Brazing/ Welding/ Gasket Renewal Etc . ( C ) Replace Gauge Line Of Leakage . ( D ) Proove Pt Of Complete System . , Gas Line System ( P25/P25a -Ref Plant ) : ( A ) Pressurize The System With Nitrogen As Maintops . ( B ) Identify And Repair Leakage By Brazing/ Welding/ Gasket Renewal Etc . ( C ) Replace Gauge Line Of Leakage . ( D ) Proove Pt Of Complete System . , Vacuum Test ( P25/P25a -Ac Plant ) : Vacuum Is To Be Raised And Proved For A Period Of 24 Hours . , Vacuum Test ( P25/P25a -Ref Plant ) : Vac

Key Value

Document Fees
Refer document
EMD
INR 520000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail