E Tender For Procurement Of Different Types Of Pacemakers For The Two Years From The Date Of Award Of Contract ( Aoc ), KOLKATA-West Bengal

Health And Family Welfare Department has published E Tender For Procurement Of Different Types Of Pacemakers For The Two Years From The Date Of Award Of Contract ( Aoc ). Submission Date for this Tender is 15-07-2021. Cardiac Pacemakers and Related Products Tenders in KOLKATA West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

22720497
Corrigendum : E Tender For Procurement Of Different Types Of Pacemakers For The Two Years From The Date Of Award Of Contract ( Aoc )
Open Tender
Indian
West Bengal
KOLKATA
15-07-2021

Tender Details

E Tender For Procurement Of Different Types Of Pacemakers For The Two Years From The Date Of Award Of Contract ( Aoc )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Jan-2020 CORRIGENDUM-3 Date 20-02-2020
2 28-Jan-2020 CORRIGENDUM-4 Date 11-03-2020
3 14-Feb-2020 CORRIGENDUM-5 Date 06-04-2020
4 13-Mar-2020 CORRIGENDUM-6 Date 06-05-2020
5 15-Apr-2020 CORRIGENDUM-7 Date 24-07-2020
6 30-Jun-2020 CORRIGENDUM-8 Date 25-09-2020
7 24-Aug-2020 CORRIGENDUM-9 Date 06-11-2020
8 01-Dec-2020 CORRIGENDUM-11 Date 19-02-2021
9 29-Jan-2021 Corrigendum-12 Date 16-04-2021
10 30-Mar-2021 CORRIGENDUM-13 Date 15-07-2021

Key Value

Document Fees
Refer document
EMD
INR 200000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: e TENDER FOR PROCUREMENT OF DIFFERENT TYPES OF PACEMAKERS FOR THE TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)
Sl. No. Item Description-- GROUP - VIII Cat No. Quantity Accounting Unit
1 8 CARDIAC RESYNCHRONIZATION WITH DEFRIBILATION THERAPY – CRT-D BIVENTRICULAR PACEMAKER + ICD WITH ALL LEADS AND ACCESSORIES BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITH ATRIAL, RV, CORONARY SINUS ( LV )LEADS AND ALL ACCESSORIES RQUIRED DURING IMPANTATION. Must have separate programmable RV, LV lead amplitude, pulse width and VV delay. The leads should be steroid eluting and should be both bipolar and unipolar configuration. RV lead must be 9F or less in sizeand DF-4 compatible. The size of RA & LV leads should be 7F or less. Should have both active and passive fixation RA & RV endocardial leads. Must have RV, RA and LV capture management. Monitor the integrity of lead and switch polarity in case of issue. Must have SVT discrimination in VF zone. All basic programmable parameters with Shock Reduction Technology comprising of T-Wave, RV-Noise discrimination features. Must have atrial tachycardia management algorithm. Must have remote patient management capability. Must monitor the lead integrity and notify in case of a suspected failure. \n\n\n THS 289
2 8.01 Pulse generator X4 DF4 [For CARDIAC RESYNCHRONIZATION WITH DEFRIBILATION THERAPY – CRT-D BIVENTRICULAR PACEMAKER + ICD WITH ALL LEADS AND ACCESSORIES BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITH ATRIAL, RV, CORONARY SINUS ( LV )LEADS AND ALL ACCESSORIES RQUIRED DURING IMPANTATION. Must have separate programmable RV, LV lead amplitude, pulse width and VV delay. The leads should be steroid eluting and should be both bipolar and unipolar configuration. RV lead must be 9F or less in sizeand DF-4 compatible. The size of RA & LV leads should be 7F or less. Should have both active and passive fixation RA & RV endocardial leads. Must have RV, RA and LV capture management. Monitor the integrity of lead and switch polarity in case of issue. Must have SVT discrimination in VF zone. All basic programmable parameters with Shock Reduction Technology comprising of T-Wave, RV-Noise discrimination features. Must have atrial tachycardia management algorithm. Must have remote patient management capability. Must monitor the lead integrity and notify in case of a suspected failure. ] THS 289(a) 1 Single Unit
3 8.02 RA Brady Lead [For CARDIAC RESYNCHRONIZATION WITH DEFRIBILATION THERAPY – CRT-D BIVENTRICULAR PACEMAKER + ICD WITH ALL LEADS AND ACCESSORIES BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITH ATRIAL, RV, CORONARY SINUS ( LV )LEADS AND ALL ACCESSORIES RQUIRED DURING IMPANTATION. Must have separate programmable RV, LV lead amplitude, pulse width and VV delay. The leads should be steroid eluting and should be both bipolar and unipolar configuration. RV lead must be 9F or less in sizeand DF-4 compatible. The size of RA & LV leads should be 7F or less. Should have both active and passive fixation RA & RV endocardial leads. Must have RV, RA and LV capture management. Monitor the integrity of lead and switch polarity in case of issue. Must have SVT discrimination in VF zone. All basic programmable parameters with Shock Reduction Technology comprising of T-Wave, RV-Noise discrimination features. Must have atrial tachycardia management algorithm. Must have remote patient management capability. Must monitor the lead integrity and notify in case of a suspected failure. ] THS 289(b) 1 Single Unit
4 8.03 RV DF4 ICD Lead [For CARDIAC RESYNCHRONIZATION WITH DEFRIBILATION THERAPY – CRT-D BIVENTRICULAR PACEMAKER + ICD WITH ALL LEADS AND ACCESSORIES BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITH ATRIAL, RV, CORONARY SINUS ( LV )LEADS AND ALL ACCESSORIES RQUIRED DURING IMPANTATION. Must have separate programmable RV, LV lead amplitude, pulse width and VV delay. The leads should be steroid eluting and should be both bipolar and unipolar configuration. RV lead must be 9F or less in sizeand DF-4 compatible. The size of RA & LV leads should be 7F or less. Should have both active and passive fixation RA & RV endocardial leads. Must have RV, RA and LV capture management. Monitor the integrity of lead and switch polarity in case of issue. Must have SVT discrimination in VF zone. All basic programmable parameters with Shock Reduction Technology comprising of T-Wave, RV-Noise discrimination features. Must have atrial tachycardia management algorithm. Must have remote patient management capability. Must monitor the lead integrity and notify in case of a suspected failure. ] THS 289(c) 1 Single Unit
5 8.04 X4 LV Lead Acuity X4 [For CARDIAC RESYNCHRONIZATION WITH DEFRIBILATION THERAPY – CRT-D BIVENTRICULAR PACEMAKER + ICD WITH ALL LEADS AND ACCESSORIES BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITH ATRIAL, RV, CORONARY SINUS ( LV )LEADS AND ALL ACCESSORIES RQUIRED DURING IMPANTATION. Must have separate programmable RV, LV lead amplitude, pulse width and VV delay. The leads should be steroid eluting and should be both bipolar and unipolar configuration. RV lead must be 9F or less in sizeand DF-4 compatible. The size of RA & LV leads should be 7F or less. Should have both active and passive fixation RA & RV endocardial leads. Must have RV, RA and LV capture management. Monitor the integrity of lead and switch polarity in case of issue. Must have SVT discrimination in VF zone. All basic programmable parameters with Shock Reduction Technology comprising of T-Wave, RV-Noise discrimination features. Must have atrial tachycardia management algorithm. Must have remote patient management capability. Must monitor the lead integrity and notify in case of a suspected failure. ] THS 289(d) 1 Single Unit
6 8.05 LV Lead Delivery System - Acuity Pro (Accessories) [For CARDIAC RESYNCHRONIZATION WITH DEFRIBILATION THERAPY – CRT-D BIVENTRICULAR PACEMAKER + ICD WITH ALL LEADS AND ACCESSORIES BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITH ATRIAL, RV, CORONARY SINUS ( LV )LEADS AND ALL ACCESSORIES RQUIRED DURING IMPANTATION. Must have separate programmable RV, LV lead amplitude, pulse width and VV delay. The leads should be steroid eluting and should be both bipolar and unipolar configuration. RV lead must be 9F or less in sizeand DF-4 compatible. The size of RA & LV leads should be 7F or less. Should have both active and passive fixation RA & RV endocardial leads. Must have RV, RA and LV capture management. Monitor the integrity of lead and switch polarity in case of issue. Must have SVT discrimination in VF zone. All basic programmable parameters with Shock Reduction Technology comprising of T-Wave, RV-Noise discrimination features. Must have atrial tachycardia management algorithm. Must have remote patient management capability. Must monitor the lead integrity and notify in case of a suspected failure. ] THS 289(e) 1 Single Unit
7 8.06 CS Guidewire (Accessories) [For CARDIAC RESYNCHRONIZATION WITH DEFRIBILATION THERAPY – CRT-D BIVENTRICULAR PACEMAKER + ICD WITH ALL LEADS AND ACCESSORIES BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITH ATRIAL, RV, CORONARY SINUS ( LV )LEADS AND ALL ACCESSORIES RQUIRED DURING IMPANTATION. Must have separate programmable RV, LV lead amplitude, pulse width and VV delay. The leads should be steroid eluting and should be both bipolar and unipolar configuration. RV lead must be 9F or less in sizeand DF-4 compatible. The size of RA & LV leads should be 7F or less. Should have both active and passive fixation RA & RV endocardial leads. Must have RV, RA and LV capture management. Monitor the integrity of lead and switch polarity in case of issue. Must have SVT discrimination in VF zone. All basic programmable parameters with Shock Reduction Technology comprising of T-Wave, RV-Noise discrimination features. Must have atrial tachycardia management algorithm. Must have remote patient management capability. Must monitor the lead integrity and notify in case of a suspected failure. ] THS 289(f) 1 Single Unit
8 8.07 Introducer Sheath (PLI) [For CARDIAC RESYNCHRONIZATION WITH DEFRIBILATION THERAPY – CRT-D BIVENTRICULAR PACEMAKER + ICD WITH ALL LEADS AND ACCESSORIES BIVENTRICULAR PACEMAKER + ICD (COMBO DEVICE) WITH ATRIAL, RV, CORONARY SINUS ( LV )LEADS AND ALL ACCESSORIES RQUIRED DURING IMPANTATION. Must have separate programmable RV, LV lead amplitude, pulse width and VV delay. The leads should be steroid eluting and should be both bipolar and unipolar configuration. RV lead must be 9F or less in sizeand DF-4 compatible. The size of RA & LV leads should be 7F or less. Should have both active and passive fixation RA & RV endocardial leads. Must have RV, RA and LV capture management. Monitor the integrity of lead and switch polarity in case of issue. Must have SVT discrimination in VF zone. All basic programmable parameters with Shock Reduction Technology comprising of T-Wave, RV-Noise discrimination features. Must have atrial tachycardia management algorithm. Must have remote patient management capability. Must monitor the lead integrity and notify in case of a suspected failure. ] THS 289(g) 1 Single Unit