}

Repair/Maintenance Of Fire Fighting Systems , Fire Panels/Equipment , Smoke Detctors With Allied Services At Hqtc , Bangalore, CH (AF) BANGALORE-Karnataka

Military Engineer Services-MES has published Repair/Maintenance Of Fire Fighting Systems , Fire Panels/Equipment , Smoke Detctors With Allied Services At Hqtc , Bangalore. Submission Date for this Tender is 06-02-2020. Spare Part Tenders in CH (AF) BANGALORE Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

22484688
Corrigendum : Repair/Maintenance Of Fire Fighting Systems , Fire Panels/Equipment , Smoke Detctors With Allied Services At Hqtc , Bangalore
Open Tender
Indian
Karnataka
CH (AF) BANGALORE
06-02-2020

Tender Details

Corrigendum - Repair / Maintenance Of Fire Fighting Systems , Fire Panels / Equipment , Smoke Detctors With Allied Services At Hqtc , Bangalore , Periodical Maintenance And Servicing Of Fire Smoke Detectors Consisting Of Bentel Panel , Smoke Detectors 8 Nos Each In A System , Fm200 Cylinder With 57 Kg Fm200 Gas , Realease Switches , Control Switches Etc , Complete By Making Regular Servicing Of The System To Ensure Proper Functioning Including Replacement Of Spare Materials All As Directed . Location :- Af Net Site-I . , Maintenance And Servicing Of 10 Hp Pump Sets 09 Numbers Fixed In Map Pocket I&Ii Complete With Motor And Starter / Panel Board For Trouble Free Operation Including Checking The Insulation Resistance And Electrical Contacts And Setting Right The Loose Electrical Contacts / Connection , Lubricating The Pump Set , Replacement / Tightening Of Gland Packing , Arresting Leakages In Suction / Delivery Lines Etc . Including Provision Of Necessary Consumables Complete All As Specified And As Directed . Notes :- ( I ) The Spares Like Bearings , Bushes , Impellors , Couplings , Etc , Wherever Required For Replacement Shall Be Measured And Paid Separately Under Relevant Items Of This Schedule . ( Ii ) The Rate Quoted Deemed To Include For Replacement Of Minor Spare Parts Costing Upto Rs . 200 / - Each . ( Ii ) The Contractor Shall Be Responsible For Trouble Free Operation Of All The Pumpsets During The Currency Of The Contract And Shall Maintenance And Repairs Carried Out And Spares Replaced Shall Be Warranted During The Contract Period . , Servicing And Testing Of Ceasefire Smoke Detection Control Panel - 28 Wireless Zones , 2 Hardwired Zone , Tamper Alert , Passcode Protected , Rf Jamming Recognition , Diagnostic Feature For Rf Signal Strength Between Panel And Each Detector , Event Reporting Using Pstn Telephone Line , Dialing Upto 4 Telephone Numbers , Event Reporting As Per Users Choice , Remote Control Using Telephone Line , Lcd Screen Display , Intuitive Graphic And Audible User Interface , Two Way Voice Interaction , Battery Backup Stand By Time Upto 12 Hrs For 2 Nos And In Each All As Specified And As Directed . Location :- Armoury , Periodical Maintenance And Servicing Of Fire Smoke Detectors Consisting Of Bentel Panel , Smoke Detectors 8 Nos Each In A System , Fm200 Cylinder With 34 Kg Fm 200 Gas , Realease Switches , Control Switches Etc , Complete By Making Regular Servicing Of The System To Ensure Proper Functioning Including Replacement Of Spare Materials All As Directed By Engineer-In-Charge ( At Af Net Site-Ii ) , Periodical Servicing Of Zone Panel And Testing Of Smoke Detector - Fully Supervised Smoke Detector Wire Less Repeater , Long Life 9 Volt Alkaline Or Lithium Battery , Simple Ceiling Mount Installtion With Separate Installation Bracket For 9 Nos In Each All As Specified And As Directed . Location :- Command It Section . Note For Sl Item No . 1 To 5 :- Defect Shall Be Rectified Within 24 Hours Of Complaint Raised . In Any Case Rectification Beyond The Stipulated Time , Penalty Shall Be Levid Rs . 500 / - Per Day . , Supply And Fixing Of 12V , 7Ah Battery For Panels In Repalcement Of Old Unserviceable Batteries All As Specified And As Directed . Make: Exide , Supply And Fix Mcp ( Manual Call Point ) Glass In Replacement Of Old Broken / Damaged Glass All As Specified And As Directed . , Supply And Refilling In Cylinder / Replacing Gas With Fm200 Gas In Cylinder All As Specified And As Directed . , Supply And Fix Wire Less Smoke Detector Of Type 1Sd12 , Operated On 9 Volts Dc Battery Complete All As Directed . Make :- Cease Fire , Supply And Fix Heat Detector For Max Operating Temp Of 68 Degree Centigrade , In Repair , Complete All As Directed . , Supply And Fix Fire Alarm Panel Suitable For Fm 200 Gas Extinguishing System , Cross Zone Operated Complete Testing And Commissioning All As Directed And Specified . Make: 5S , Supply And Fix 1 . 5 Sqmm , 2 Core Flexible Armoured Copper Cable For Fire Detectors Comminication Compete All As Directed And Specified . , Supply And Fix Transformer 50 Va , Dry Type , Air Cooled , For 12 Zone Fire Alarm Conventional Panel Complete All As Directed And Specified . Make: Mini Max , Supply And Fix Alkaline Dry Battery 9 Volts , Pp3 Size , With Dura Lock Complete All As Directed . Make: Duracell Or Equivalent . , Supply And Fix Timer Unit For Automatic Fire Control Panel Opereated On Single Phase 230 Volts , Ac , 50Hz Complete Fixed In Repair All As Directed And Specified . Make: Selecktron Model-800S . , Supply And Fix Thermal Over Load Relay Of 10A With Max Fuse Rating At 32A Complies To Is:9224 Operated On Single Phase 230 Volts , Ac , 50Hz Complete In Repair All As Directed And Specified . , Supply And Fix Contactor , Continous Current Rating 40 A , 3 Phase , 440 Volts Complete In Repair All As Directed And Specified . Make: C&S . , Replacement Of Manual Call Point Duly Painted In Red Colour With Front Glass ( To Be Broken In Case Of Fire ) Complete With Test Key To Check He Response Without Breaking The Glass And Die Cast Aluminium Housing With Ifd Indicator All As Specified . , Replacement Of Zone Cards . , Spray Painting Of Fire Fighting Equipment By Applying One Coat Of Primer And Two Coats Of Synthetic Enamel Paint Of Red Colour ( Post Office Colour ) All As Specified & Directed . , Supply & Fix In Replacement Of First Aid Hose Fire Reel Wall Mounted Type Fitted With Of Dia 20 Mm And 30 Mtr Length , Hose With Isi Marked Ss Shut Of Nozzle And Connection Of 20Mm Gate Valve And Pipe Complete All As Specified And Directed . , Rewinding Of Motor Up To 10 Hp Capacity With Super Enameled Copper Winding Wire Of Suitable Gauge And Size , Providing Insulating Materials Such As Fibre Glass Tape , Varnishing , Heating Up Assembling In The Electric Motor , Testing And Commissioning Complete Including Replacement Of Bearings / Bushes By Using Hydraulic Press For Testing To Full Load All As Specified And As Directed Including Dismantling & Taking To Work Shop And Bring Back And Re Assembling All As Directed . , Supply And Fix Ball Bearing Both End Sealed Suitable To Fix With Electric Motor Of 10 Hp Capacity Fixed In Repairs All As Specified And As Directed . , Magnetic Sensor Suitable For Micro Processor Based Digital Water Level Indicator Fixed At Different Levels Inside Sump / Over Head Reservoir For Sensing Level Of Water Including Dismantling Old Unserviceable Sensor All As Directed , Pvc Insulated Copper Conductor Cable , 12 Core X 0 . 6Mm Gauge , Superior Quality Suitable For Carrying Signals From Sensor To Digital Water Level Indicator Of Approved Make Including Taking Down Existing Un-Serviceable Cable All As Specified And Directed . Make: Sunrich , Supply And Fix Fire Alarm Isi Marked Including Taking Down Old Unserviceable All As Directed . , Supply And Fix Single Phase Preventer Suitable For Any Capacity Upto 20 Hp Pump Sets Including Dismantling And Taking Up Old Unserviceable All As Specified And Directed . Make: L&T / Minilac , Supply And Instal Digital Water Level Indicator Fitted On 25000 Ltr Capacity Fire Tanks On Airmen Map Pocket -I &Ii Complete Including Necessary Accessories Connecting Cables , Digital Display Etc All As Specified And Directed . , Supply & Fix In Replacement Of Gun Metal Coupling Assembly With Lug ( Locking Pin ) For Hydrant Valve Complete E All As Specified And Directed . , Supply And Fix Water Pressure Guage 100Mm Dia Ranging 0-14 Kg / Sqcm Including Dismantling Unserviceable Exisitng Pressure Guage Complete All As Specified And Directed . Make: Accurate , Supply And Fix In Replacement Of Gun Metal One Way Fire Hydrant Landing Valve Of Size 63Mm Dia Isi Marked Complete With Instantaneous Coupling Complete All As Specified And

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Jan-2020 Change date. Date 07-01-2020
2 08-Jan-2020 Corrigendum date Date 16-01-2020
3 17-Jan-2020 Change date.. Date 23-01-2020
4 24-Jan-2020 Change of_date Date 30-01-2020
5 31-Jan-2020 Change.date. Date 06-02-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 25000.0 /-
Tender Value
INR 12.50 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail