Tenders Are Invited For Integrity Test, Remaining Life Assessment And Fitness For Service

Tender Detail

51916363
2332201084
Self-Funded
Tenders Are Invited For Integrity Test, Remaining Life Assessment And Fitness For Service
ICB
Western Asia
Arab World,Gulf Cooperation Council, GCC,Middle East,Middle East and North Africa, MENA
08-06-2022

Work Detail

Quotation Are Invited For Integrity Test, Remaining Life Assessment And Fitness For Service. Integrity Inspection, Remaining Life Assessment And Fitness For Service Certification For Fuel Oil Day Tanks At H Station Al-Awee R. Technical And General Specification Of Fuel Oil Day Tank Of Emergency Diesel Generator For Integrity Analysis At H-Station, Al-A Weer Power Station. 1.#Introduction: Integrity Analysis Of Instrument Air Receiver Tank As Per Api 510, Dcd & Dac Guidelines. Inte Grity Analysis To Be Done By Api Authorized Inspector Under The Guidelines Of Dcd & Dac. Total Qty. 2 Nos. As Per Below Detail 1.#P Hase-1: Fuel Oil Day Tank Of Emergency Diesel Generator 1.1.#Capacity: 5000 Liters; Diameter: 1600 Mm & Length: 2820 Mm 2.#Period O F Work: 2 Days/Tank 3.#Scope Of Work: 3.1.#Scope Of Work Include, But Not Limited To The Following 3.1.1.#The Contractor Shall Visi T The Site And Make Himself Fully Familiar With The Work Scope, Plant Access, Facilities, Complexities, Safety Measures Etc., Before He Submit His Bid. 3.1.2.#Check Condition Suitable To Carry Out Work. Conduct Site Survey And Safety Inspection To Assess The Worki Ng Environment. 3.1.3.#If Working Environment Is Safe Proceed The Following Steps. 3.1.4.#Mobilize The Api/Asme And Civil Defense Li Cense Holder Authorized Inspector With Suitable Inspection Tools, Ppes And Consumables, Etc. On 2 Days# Notice Period. 3.1.5.#To Pro Vide Services Of Experienced And Certified Inspectors. 3.1.6.#All Equipment Necessary To Execute Inspection And Measurement Shall Be The Scope Of Contractor. 3.1.7.#Contractor Shall Carry Out Integrity Assessment And Rla. 3.1.8.#To Collect Data On Original Design And Fabrication Practices, The Material Of Construction, And The Service History. 3.1.9.#Develop Integrity Management Plan (Imp) 3.1 .10.#Prepare Inspection Test Protocol (Itp) To Implement Imp And To Collect Nde Data On Present Condition Of The Asset Under Scope. 3.1.11.#Itp Shall Have Necessary Inspection-Related Information Detailing All The Components/Structures Without Any Exception, To Pl An The Activities During Shutdown Inspection. 3.1.12.#A Markup Drawing Shall Be Prepared Showing All The Cml Locations. A Unique Ide Ntification Has To Be Developed For Cmls. Copy Of Existing Drawings Shall Be Used To Mark Cml Points. 3.1.13.#All Nde Shall Be In Th E Scope Of Contractor Along With Their Test Equipment, Tools, Tackles, Consumables And Certified Personnel. Comparison Against Requi Rements Provided In The Drawings To Be Made By The Contractor. 3.1.14. All The Inspection/Certification Required Post Repair Is Also Part Of The Contractor Scope Of Work And Shall Be Performed After Dewa Completes Recommended Repairs. 3.1.15. Inspection Shall Be C Onducted Without Emptying Of Tank In Utmost Safe Manner. 3.2.#Tank Out Of Service Inspection: 3.2.1.#Determining The Condition And Integrity Of The Tank. 3.2.2.#The Authorized Inspector Who Is Responsible For Evaluation Of A Tank Must Conduct A Visual Inspection And Assure The Quality. 3.2.3.#A Complete Visual Inspection Shall Be Performed To Identify Any Surface Defect And Shall Take Account Of The Original Specification. 3.2.4.#The Inspection Methods Shall Be Capable Of Assessing The Thickness Of The Tank, In Combinatio N With Methods Capable Of Assessing Tank Integrity. 3.2.5.#The Authorize Inspector Shall Ensure The Competence Of Nondestructive Exa Mination (Nde) Results By Suitable Methods. 3.2.6.#Painting Or Coating Shall Be Visually Inspected, Defects Shall Be Identified And Recorded In The Report. 3.2.7.#The Tank Thickness Shall Be Ascertained By Non-Destructive Testing Like Ultrasonic Testing Or Any Oth Er Suitable Approved Technics. 3.2.8.#Gather The Data Necessary For The Minimum Thickness Assessments Detail. 3.2.9.#The Data And In Formation Collected Should Be Sufficient To Evaluate The Thickness, Corrosion Rate, And Integrity Of The Tank And Establish The Inte Rnal Inspection Interval, Based On Tank Thickness, Corrosion Rate, And Integrity, Utilizing The Standard Methods. 3.2.10.#The Author Ized Inspector Who Is Responsible For Evaluation Of A Tank Must Assure The Quality And Competence For The Inspection Method. 3.2.11. #Identify And Evaluate Any Tank Foundation Crack. 3.2.12.#The Condition And Functional Of Heat Detectors, Flame Detectors And Alarm System Equipment Shall Be Checked Thoroughly. 3.2.13.#Inspection Of Cp System & Earthling Terminal. 3.2.14.#Level Indicator, Valves And Other Tank Related Equipment Inspection. 3.2.15.#Recommendation For Repair Shall Be Made In Cases Of Severe Defects Or Uneven/Da Maged Surface Which May Cause High Stresses Or Threat To The Integrity Of The Tank. 3.2.16.#Where Documents Are Not Available, The I Nspector Shall Estimate The Original Thickness Of The Material Based On His Experience, Standard And The Type Of Tank. 3.2.17.#Out O F Service Inspection Report To Be Filled As Per Api Standard. 3.2.18.#The Tank Is Complete Insulated. Party Gas To Identify The Loca Tion As Per The Cml Drawing To Remove The Insulations From The Tanks 4.#Tank Repair If Required Appointed Api 510 Inspector / Contr Actor Shall Provide The Necessary Repairs Recommendations As Per The International Standard Requirements For Tank Bottom, Shell Repa Ir & Replacement. 5.#Reports And Report Contents For Out Of Service Inspection Performed, The Authorized Inspector Shall Prepare A Written Report. These Inspection Reports Along With Inspector Recommendations Qty: 2 Integrity Test, Remaining Life Assessment And Fitness For Service Certification; For Technical Detail Please Contact Zamir Alware On Zamir.Alware@Dewa.Gov.Ae / 04-8140304 Or 050-9152946 Or Sumit Mehta On Sumit.Mehta@Dewa.Gov.Ae 052-1052809 Or 04-8140306 Standard Terms & Conditions 1) Prices Should Be Ddp Delivery Duty Paid At Dewa Stores. 2) Quotation To Be Submitted Only In Local Currency U.A.E Dirhams 3) Dewa Standard Payment Terms Is 30 Days Credit From The Date Of Acceptance Of Material 4) No Dewa Staff Or His Or Her Relatives Up To Third Degree Should Have Ownership Or Partnership In Your Company, And Your Participation In Dewa Tenders / Rfqs Should Not Constitute A Conflict Or Perceived Conflict Of Interest. Tender Link : Https://Www.Dewa.Gov.Ae/Api/Rfxdownload/2332201084

Key Value

Tender Value
Refer document

Attachment

FileName File Description
Global Tender Document Tender Notice
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail