6515 Medstation Automated Medication Dispensing Brand Name Or Equal

Tender Detail

36866427
36C25621Q0300
Self Funded
6515 Medstation Automated Medication Dispensing Brand Name Or Equal
ICB
Northern America
Asia-Pacific Economic Cooperation, APEC,G20
15-02-2021

Work Detail

View Changes Question Answer Reference Page 11 Delivery The Contractor Shall Ensure All Deliverables Are Shipped And Received By The Va Within 120 Days After Contract Award Unless Specified By The Contracting Office Representative Cor All Items Are To Be Shipped And Delivered To The Warehouse Building 100 At 2002 Holcombe Blvd Houston Tx 77030 Question Deliveries Will Be Scheduled To Support A Mutually Agreeable Project Delivery Timeline Bd Does Not Take Responsibility For Transport After Initial Delivery For Any Resulting Damage That Could Occur To Equipment Transported To Final Location For The Product Installation Is The Vahcs Houston Warehouse The Same Campus For Final Delivery Where The Installation Of The Product Takes Place Medvamc Response Yes This Will Be Main Delivery Location Through Approved Coordination Delivery Shall Be Made For Cabinets At Cbocs Keep In Mind A Complete Implementation Meeting Shall Be Conducted To Address All Aspects Of This Requirement Once Awarded Reference Page 12 Support Services The Contractor Shall For Each Applicable Deliverable Offer On Site Support Services For 12 Months At No Charge Which Shall Commence Upon Completion Of Installation By The Contractor And Subsequent Government Acceptance After 12 Months The Contractor Shall Provide Remote Assistance Services For A Period Of No Less Than 5 Years Question Does Customer Agree Remote And On Site Support Is Included During The Warranty Period And After The Warranty Period Remote And On Site Support Will Be Provided Under A Contracted Support Plan Or If No Support Plan It Will Be Provided On A Time And Material Basis Medvamc Response Government S Intent Is To Establish 5 Years Of Support After Initial Award Which Covers All Software And Hardware Issues Inclusive Of Preventive Maintenance Corrective Maintenance And Accidental Damage For 12 Months Option Years 1 4 Will Be Exercised In The Fiscal Year In Which The Period Of Performance Is Required Using Current Year Funds Reference Page 12 Warranty If The Media On Which Any Licensed Software Is Embodied Contains Material Defects The Contractor Shall Replace Such Media This Will Be The Contractor S Sole And Exclusive Obligation With Respect To Such Warranty For The Licensed Software Warranty Provision Begins 30 Days After The Date Of Government Acceptance Question Does Customer Accept That During The Warranty Period The Product Will Perform Substantially In Accordance With The Specifications Of Its User Guide And That The 12 Month Limited Warranty Will Commence Upon Customer Acceptance Of The Equipment Medvamc Response Customer Cannot Predict Whether Or Not The System Will Function In Accordance With The Manufacturer S Specifications The Warranty Statement Is To Safe Guard Against Material Defects Reference Tasks And Associated Deliverables Task 1 Project Management Plan Pmp The Pmp Shall Include The Contractor S Approach To Management Of The Project Schedule Resource Staffing Quality Control Risk Management Communications Configuration Management Change Management And Issues Log The Contractor Shall Provide An Implementation Plan Transition Plan To Remove The Old Units And Install The New Equipment A Cut Sheet Shall Be Provided Upon Reward Of Contract Equipment Must Not Be Shipped Until The Recognized Planned Date Question Due To Legal Liability Bd Employees Cannot Move Existing Equipment Existing Product Or Existing Trash Within Customer Facilities Bd Requests This Requirement Be Removed Medvamc Response Bd And Customer Shall Develop An Approve Transition Plan Then Incumbent Will Remove Their Equipment Iaw Implementation During Implementation Any Trash Shall Be Cleaned By That Vendor Reference Tasks And Associated Deliverables Task 2 Analysis Of Current Process And Recommendations Question Will Partnering With Contractor S Clinical Resources Partner During Pre Deployment To Discuss Current Workflow Challenges And Opportunities For Improvements In Efficiencies With Contractor S Technology Solutions Satisfy This Requirement Medvamc Response Yes Only If The Objectives Of Task 2 Are Met Reference Tasks And Associated Deliverables Task 5 Deliver New Process Training The Contractor Shall Deliver Training On The New Process On The Va Site For A Minimum Of 1 Year The Vendor Shall Provide Remote Assistance For A Period Of 5 Years The Contractor Shall Provide A Product Demonstration Question Bd Will Train Customer Super Users To Be Training Resources For Other End Users Considered Train The Trainer During Implementation Customers May Request Additional Training At An Additional Cost Is This Acceptable To The Customer Medvamc Response Train The Trainer Is Acceptable Reference Tasks And Associated Deliverables Task 6 Software Specifications Equipment Must Be Based On Operating Systems That Are Currently Supported By The Manufacturer Such As Microsoft Windows 10 And Microsoft Server 2016 All Software And Licenses Needed For Operation Must Be Included For The Life Of The Product No Less Than 7 Years System Shall Be Compatible With Electronic Medical Record Systems Vista And Cerner In Addition The System Shall Be Compatible With Pandora Analytics Va Bcma V3 0 Diversion Services System Manager Integration For Iv Pumps Swiss Log Box Picker Devices Shall Meet Fips 140 2 Requirements And Must Be Approved To Operate On The Va Network The System Shall Be Capable Of Running On Virtual Or Physical Servers The Offeror Must Have An Interconnection Service Agreement Mou Isa For Remote Support Of Devices Reporting Shall Be Accessible By An Unlimited Number Of Concurrent Users Via An Encrypted Web Gui Equipment Shall Integrate With Supplies Equipment Shall Include Dosage Tracking Software That Will Track The Process Of The Medicine Leaving From The Pharmacy Up To The Point Of The Medication Being Dispensed From The Device Question Will Contractor Be Required To Implement Va 6550 Rmf Process If Contractor Already Has Authorization For Medstation Es Through The Dha Rmf Medvamc Response Yes The Current 6550 Enterprise Risk Assessment Era Is Required Many Items From Multiple Manufacturers Are Already Approved If Proposed Items Or Configuration Will Differ From Those That Are Already Approved Or The Era Is Older Than 12 Months We Will Have To Complete This Process Reference B 2 Price Cost Schedule Item Information All Items Are Updated See Attcahed List Item 0010 Amp Item 0050 Listed As 43 Ea The Main Hospital Requires 36 Ea And The Cboc Requires 9 Ea For Total Of 45 Item 0014 Amp Item 0053 Listed As 45 Ea The Main Hospital Requires 38 Ea And The Cboc Requires 9 Ea For A Total Of 47 Item 0022 Amp Item 0061 This Item Is Not Needed Please Remove The Main Facility Will Host The Server And Therefore Will Not Require The Es Facility License Item 0023 Amp Item 0062 The Product Code And Description Listed Have Changed And Has Been Replaced With 134561 01 Cce Enterprise Sw Site License Please Change The Product Code And Description To 134561 01 Cce Enterprise Sw Site License For These Two Item Numbers Item 0024 Amp Item 0063 The Quantity Is Incorrect And Should Be Changed To 1 Each Please Change The Quantity To 1 Each For These Two Item Numbers Item 0030 Hosted Data Services Is An Incorrect Product Code Please Change The Product Code To 138603 01 This Is A Monthly Subscription And Will Be Priced Under Item 0069 As There Is Not A Purchase Price Available Item 0030 Can Be Removed Item 0031 Amp Item 0070 The Product Code And Description Have Changed And Replaced With 134157 01 Es S W Only Server Please Change The Product Code And Description To 134157 01 Es S W Only Server For These Two Item Numbers Item 0034 Amp Item 0073 The Product Code Listed Has Changed And Has Been Replaced With 801 Please Change The Product Code To 801 For These Two Item Numbers Item 0040 Amp Item 0079 The Product Code Listed Has Changed And Has Been Replaced With 134780 01 Sls Admin Tool S W App Regional License Please Change The Product Code And Description To 134780 01 Sls Admin Tool S W App Regional License For These Two Item Numbers Item 0015 Amp Item 0053 Item 0015 Medstation Es Aux Tower Dc Is Missing An Item Number For The Monthly Support Maintenance Fee It Is The Same Price As Item 0053 And That Quantity Can Be Increased By 1 For A Total Of 46 Each Item 0066 Amp Item 0067 Amp Item 0068 The Product Codes Listed Are Included With The System And Are No Longer Needed To Be Listed As Separate Line Items And Can Be Removed From The Item List Please Remove These Three Item Numbers Item 0069 Hosted Data Services Is An Incorrect Product Code Please Change The Product Code To 138603 01 And Quantity Of 12 Months For The Base Year This Is A Monthly Subscription Similar To Maintenance Support Item 0072 Listed As A Quantity Of 89 Each Please Update This Quantity To 12 To Match Item 0033 Item 0080 Amp Item 0085 137555 01 Pyxises Ref 5Cf Lhg 3 Std Bins Listed As 70 Ea The Main Hospital Requires 43 Ea And The Cboc Requires 18 Ea For A Total Of 61 Please Change Quantity To 61 On The Equipment List The Solicitation Requires Vendors Provide A Custom Design For Each Careline And Cboc Conducting An On Site Assessment Prior To Quotation Will Enable Vendors To Meet This Requirement Can Vendors Conduct An On Site Assessment To Fully Evaluate The Needs Of Each Careline Prior To Quotation This Will Ensure All Quotes Are Accurate To Fullest Extent And Not Over Or Under Quoted Medvamc Response Yes We Can Facilitate An On Site Assessment We Would Be Grateful For The Opportunity To Have A Discussion With Current Medvamc Users To Assess Performance Metrics To Ensure That We Are Able To Provide A Response That Most Accurately Fulfills The Solicitation S Mission Medvamc Response The Government Is Unable To Facilitate Any Discussion With Staff Members On Site Assessment Will Allow Vendors To Quote Iaw Solicitation The Solicitation Requires That Each Device Piece Of Equipment Can Be Constructed With 5 Of Extra Space For Inventory Can We Conduct An On Site Assessment Prior To Quotation To Determine Inventory Needs In Order To Properly Quote To Meet The Requirements Of The Solicitation Medvamc Response Yes We Can Facilitate An On Site Assessment 4 The Sow Doesn T Allow Vendors Other Than Bd The Opportunity To Quote Due To Inconsistencies With Product Descriptions And Quantities For Each Careline Please Provide A Detailed Location Equipment List That Describes Each Patient Care Area And The Needed Cabinets Or Towers To Support That Location Respectfully An Excel Template Has Been Provided For This Information Medvamc Response The Requirement Has Not Changed See Attached Spreadsheets See Attached Updated Item List Though The Requirement Is Being Solicited As A Brand Name Or Equal There Are A Few Areas Which Are Specific Only To Bd Pyxis Other Solutions Can Achieve The Same Central Mission Through Alternate Means Medvamc Response This Procurement Is Being Processed On A Brand Name Or Equal Basis In Accordance With Federal Acquisition Regulation 11 104 Bd Pyxis Is The Reference Brand For The Requirement Description The Following Schedule Of Supplies And Services Contract Line Items 0001 Through 0089 Represents The Acceptable Bd Pyxis Medication Dispensing System Solution Vendors Offering A Different Brand Solution Should Use The Schedule Of Supplies And Services Contract Line Items To Formulate Their Proposed Equal Solution Considering Equipment And Quantities As Long As A Proposed Equal Solution Has An Acceptable History For Successfully Meeting The Medication Dispensing System Needs Of A Hospital Of A Similar Size As Medvamc The Proposed Different Brand Solution Will Be Considered As Equal In Addition The System Shall Be Compatible With Alaris System Manager Integration For Iv Pumps A This Requirement Was Removed Via Amendment From The Original Solicitation As It Was Deemed To Be Too Specific All Of The Equipment Onsite Are Required To Connect Through Cerner Vista Alaris Is Specifically A Bd Application System Shall Be Compatible With Electronic Medical Record Systems Vista And Cerner In Addition The System Shall Be Compatible With Pandora Analytics Va Bcma V3 0 Diversion Services System Manager Integration For Iv Pumps Swiss Log Box Picker Devices Shall Meet Fips 140 2 Requirements And Must Be Approved To Operate On The Va Network The System Shall Be Capable Of Running On Virtual Or Physical Servers The Offeror Must Have An Interconnection Service Agreement Mou Isa For Remote Each Drawer Is Preferred To Include A Clear Top That Will Allow The End User To View The Medications When The Drawer Is Opened A This Aspect Was Removed Via Amendment Through The Original Solicitation As Bd Is The Only Manufacturer That Provides This Feature And It Is Not Recommended Because It Can Make It Easier To Divert Controlled Substances Medvamc Response Clear Top Is Not Mandatory And Will Not Disqualify A Solution If Not Provided

Key Value

Tender Value
Refer document

Attachment

FileName File Description
Global Tender Document Tender Notice
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail