Y1dz Project 561 18 180 Correct Fca D Amp F Deficiencies Boiler Plant Bldg 8 Actionable Package 09 14 L Current Phase I Requirements Complete Proposals Bids Due Tbd Proposed Award 12 15 L Comments Date 09 14 Received

Tender Detail

36073221
36C24220B0062
Self Funded
Y1dz Project 561 18 180 Correct Fca D Amp F Deficiencies Boiler Plant Bldg 8 Actionable Package 09 14 L Current Phase I Requirements Complete Proposals Bids Due Tbd Proposed Award 12 15 L Comments Date 09 14 Received
ICB
Northern America
Asia-Pacific Economic Cooperation, APEC,G20
24-11-2020

Work Detail

Page 1 Of 1 This Notice Is For Solicitation Number 36C24220b0062 Project Number 561 18 180 Correct Fca D Amp F Deficiencies Boiler Plant Bldg 8 At The Va East Orange Campus At 385 Tremont Ave East Orange Nj 07018 This Shall Be A Service Disabled Veteran Owned Small Business Set Aside Sdvosb As A Result All Sdvosb s May Submit A Bid Which Will Be Considered By The Agency This Project Is Classified Under Naics Code 236220 And Has A Size Standard Of 36 5 Million The Cost Estimate Range For This Project Is 1 00 000 00 To 2 000 000 00 Scope Of Work Correct Fca Deficiencies Project Involves Mechanical Electrical Plumbing And Structural Work As Depicted In The Project Drawings And Specifications A Item I General Construciton Correct Fca Deficiencies Project Involves Mechanical Electrical Plumbing And Structural Work As Depicted In The Project Drawings And Specifications Completion For Bid Item I Shall Be Within A Maximum Of 180 Days This Work Includes But Is Not Limited To The Following General Outline 1 Pre Demolition Preparatory Work Including Installation Of A Temporary Boiler Blowdown System Consisting Of Boiler Blowdown Piping Domestic Water Piping Temporary Blowdown Separator And Drain Piping To The Existing Underground Site Sanitary System 2 Installation Of A New Boiler Blowdown Piping System Including New Blowdown Separator Vent Piping Blowdown Cooler With Domestic Water Feed And Connection To Existing Underground Sanitary Line Outside The Building Existing Boiler Blowdown Piping To Be Demolished 3 Replacement Of Approx 150Lf Of Boiler Room Pipe Trench Including New Grating Covers 4 Demolition Of Existing Boiler Room Roof Mounted Gravity Intakes Makeup Air Heaters And Associated Steam And Condensate Piping And Accessories 5 Installation Of New Combustion Air Equipment Including Gravity Intakes Three New Roof Penetrations Steam Unit Heaters New Connection To High Pressure Steam Main Steam Pressure Reducing Station And Associated Steam And Condensate Piping And Accessories 6 Replacement Of 4 Roof Mounted Centrifugal Fans On Existing Roof Curbs 7 Installation Of Approximately 38 Lf Of Freestanding Ballasted Type Safety Railing Around Entire Perimeter Of Roof 8 Replacement Of 3 Double Doors And Frames And 1 Single Door And Frame 9 Construction Of New Closer Around Existing It Equipment Including New Split System Air Conditioning System 10 Hydro Jet Cleaning And Repair Of Approximately 150Lf Of Underground Sanitary Piping And Floor Drains And Replacement Of Approximately 180Lf Of Underground Sanitary Piping And Floor Drains 11 Installation Of A New 40 Gallon Electric Hot Water Heater And Associated Piping 12 Replacement In Kind Of A 25 Gallon Generator Fuel Oil Day Tank 13 Electrical Connections To New Mechanical Equipment With New Breakers Conduit Feeders And Motor Starters And Disconnections And Reconnections To Boiler Control Panels Being Replaced 14 Replacement Of Distribution Panel Dp Em And Replacement Of Existing Generator Automatic Transfer Switch In New Location Including Extension Of Feeders Contractor Shall Provide A Temporary Generator During The Period Of Time This Work Is Being Performed 15 Demolition Of Existing Motor Control Center And Installation Of New Motor Control Panel In New Location Includes Extension Of Feeders 16 Replacement Of Existing Distribution Panel Mdp And Installation In New Location Includes Extension Of Feeders 17 Repair Extension And Certification Of Existing Lightning Protection System 18 Provide New Propane Pilot Gas Piping System Including Exterior Dual Gas Cylinder Wall Bracket Regulator Piping To 4 Boilers Plus Valving And Accessories B Item Ii Correct Fca Deficiencies Project Involves Work On Proprietary Deaerator Boiler Systems And Boiler Controls Systems As Depicted In The Project Drawings And Specifications Completion For Bid Item Ii Shall Be Within A Maximum Of 180 Days Concurrent With Item I All Items Associated With The Cleaver Brooks Deaerator Boilers And Control Systems Must Be Provided And Installed By The Local Cleaverbrooks Authorized And Trained Service Representative Per The Oem Procedures The Local Cleaver Brooks Authorized Representative For The Project Area Is Miller Amp Chitty Company Inc P O Box 256 139 Market Street Kenilworth New Jersey 07033 This Work Includes But Is Not Limited To The Following General Outline 1 Provide The Following Work As A Sole Sourced Turnkey Supply And Installation Package Contract To The Local Cleaver Brooks Authorized And Trained Service Representative The Description Of Work Is To Include But Is Not Limited To The Following A Provide New Deaerator Overflow System Reference Fca Deficiency Item No 5 This System Shall Consist Of The Following New Items 1 Mobrey Hydratect 2462 Steam Water Detection Level Control System Control Panel 2 2 150 Keystone Series 362 High Performance Double Offset Butterfly Valve With Keystone K Lok Actuator 3 Two 2 Level Control Probes And Piping Inserts Note Verification Of The Existing Water Level Internal Stand Pipe Height Prior To Installation Of The High Alarm And Overflow Valve Probes Are Installed 4 Modifications To The Existing 2 Gauge Glass Piping To Accommodate The Two 2 Level Control Probes 5 Modification Removal Of The Existing Overflow Trap To Accommodate New 2 Butterfly Valve 2 Provide The Following Work As A Sole Sourced Turnkey Supply And Installation Package Contract To The Local Cleaver Brooks Authorized And Trained Service Representative The Description Of Work Is To Include But Is Not Limited To The Following A Provide New Cleaver Brooks Hawk 4000 Boiler Control System Reference Fca Deficiency Item No 6 1 Four 4 Cleaver Brooks Hawk 4000 Conversion Kits One For Each Existing Boiler Each Conversion Kit Will Include A Cleaver Brooks Hawk Control Panel With 10 Color Screen Mounted In Enclosure B Boiler Entrance Panel C Cb 780E Flame Safeguard Control D Current Sensors For Blower And Compressor Motors E 120 Volt Uninterruptable Power Supply Ups Panel F Servo Motors For Natural Gas No 2 Fuel Oil Fgr And Air Damper G Cleaver Brooks Integrated Oxygen Trim Package Consisting Of High And Low Gas Pressure Switches 5 Port Ethernet Hub Expanded Annunciation Transmitter For Steam Pressure Flue Gas And Ambient Air Temperature Transmitters 2 One 1 Cleaver Brooks Master Panel For Four 4 Boilers 3 Boiler Control Conversion Also Includes The Following A New Oil Train Oil Valves Oil Accumulator Pressure Gages High And Low Pressure Control With Test Connections And Oil Meter With 4 20Ma Output 4 Programming The 4000 Controls And Master Panel 3 Provide The Following Work As A Sole Sourced Turnkey Supply And Installation Package Contract To The Local Cleaver Brooks Authorized And Trained Service Representative The Description Of Work Is To Include But Is Not Limited To The Following A Modify Each Boiler S Natural Gas Fuel Train 1 Remove Existing And Provide New Natural Gas Regulator To Each Of The 4 Four Existing 600 Hp Boiler Gas Trains New Gas Regulators Shall Be 3 150 Raised Face Flanged Connections Fisher 1098 Egr Regulator Dual Pilot Carbon Steel Body 416 Sst Plug And Seat Ring Size 70 Actuator 0 20 Psig Spring Range Fisher Y600am Regulator Pilot Npt Connection Cast Iron 15 Wc 1 2 Psig Spring Range Fisher 6352 Regulator Pilot Aluminum 14 Wc 2 Psig Spring Range P594 1 Filter Standard Gain New Regulators Will Be Tested And Combustion Reset Reference Fca Deficiency Item No 7 2 Modify Proof Of Closure Poc Connection Located Between The Two 2 Existing Maxon Automatic Gas Shut Off Valves Provide New Electrical Access Box And Remove Wiring From Existing Valve Actuators Related To Proof Of Closure Relocate Valve Wiring In A More Accessible Electrical Box Box Will Be Labeled As Gas Poc Testing 4 Provide The Following Work As A Sole Sourced Turnkey Supply And Installation Package Contract To The Local Cleaver Brooks Authorized And Trained Service Representative The Description Of Work Is To Include But Is Not Limited To The Following A Modify Each Boiler S No 2 Fuel Oil Train 1 Remove Wiring From Oil Valves Related To Proof Of Closure Relocate Valve Wiring In A More Accessible Electrical Box Box Will Be Labeled As Oil Poc Testing 5 Provide The Following Work As A Sole Sourced Turnkey Supply And Installation Package Contract To The Local Cleaver Brooks Authorized And Trained Service Representative The Description Of Work Is To Include But Is Not Limited To The Following A Provide Replacement Boiler Atomizing Air Pressure Components 1 Provide Four 4 Atomizing Pressure Switches 2 Provide Four 4 Locking Ball Valves 3 Provide Four 4 Ball Valves All Other Details And Information Shall Be Contained In The Solicitation Which Shall Be Posted On Https Beta Sam Gov The Solicitation Will Be Released On Or About 10 15 2020 The Response Submittal Address Date And Time Will Be Included In The Solicitation This Project Requires Bonding And All Responses Submissions Shall Be In Hardcopies Faxed Or E Mailed Bids Will Not Be Accepted All Prospective Bidders Must Be Currently Registered In Www Sam Gov And Be Registered And Verified As A Sdvosb In Www Vip Vetbiz Gov At The Time Of Offer Submission And Before Award Of This Procurement End Of

Key Value

Tender Value
Refer document

Attachment

FileName File Description
Global Tender Document Tender Notice
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail