Cable Laying and Termination for Protection System Up Gradation for D Rep Units D11 D12 D13

Tender Detail

32773379
2332001756
Self Funded
Cable Laying and Termination for Protection System Up Gradation for D Rep Units D11 D12 D13
ICB
Western Asia
Arab World,Gulf Cooperation Council, GCC,Middle East,Middle East and North Africa, MENA
03-09-2020

Work Detail

Quotation are invited for Cable Laying and Termination for Protection System Up Gradation for D Rep Units D11 D12 D13 D REP GENERATOR ADDITIONAL PROTECTION SCHEME 4X6 SQMM 3X500 METERS OF NEW COPPER CABLE LAYING AND TERMINATION SCOPE OF WORK INTRODU CTION AND GENERAL REQUIREMENT CABLE LAYING SERVICE IS REQUIRED FOR LAYING APPROXIMATELY 1500 METER 6 SQ MM X 4 CORE CABLE BETWEEN DREP LOCAL CONTROL PANEL AND 400 KV SWITCHGEAR ROOM THE PROSPECTIVE SUPPLIER MAY VISIT THE SITE TO TAKE THE ACTUAL MEASUREMENTS FOR LENGTH OF CABLES FROM AND TO THE INSTALLED PANELS PLANT SITE VISIT CORRESPONDENCE SHALL BE COMMUNICATED BY E MAIL TO MR TARIQ ALH ASHMI ENGINEER EMD D TARIQ ALHASHMI DEWA GOV AE WITH CC TO MR G RADHAKRISNAN ENGINEER EMD D GANESAN KRISHNAN DEWA GOV AE AND MR PRAKASH MUTHURAM SENIOR SUPERVISOR EMD D MUTHURAM MUTHURAM DEWA GOV AE FOR ALL COMMUNICATIONS THE CONTRACTOR MAY CONTACT MR TARIQ ON 04 8044229 0502021721 MR RADHAKRISHNAN ON 04 8044429 050 5447961 OR MR PRAKASH ON 04 8044166 OR 050 8961682 CABLE LAYING AL L CABLE ROUTES SHALL BE CAREFULLY MEASURED AND CABLES CUT TO THE REQUIRED LENGTHS LEAVING SUFFICIENT LENGTHS FOR THE FINAL CONNECTI ON OF THE CABLE TO THE TERMINAL OF THE EQUIPMENT THE VARIOUS CABLE LENGTHS CUT FROM THE CABLE REELS SHALL BE CAREFULLY SELECTED TO PREVENT UNDUE WASTAGE OF CABLES THE QUANTITY INDICATED IN THE CABLE SCHEDULE IS ONLY APPROXIMATE ACTUAL LENGTH WILL BE LESSER THAN IT LAID CABLES SHALL BE NEATLY ARRANGED IN THE TRENCHES TRAYS IN SUCH MANNER SO THAT CRISSCROSSING IS AVOIDED AND FINAL TAKE OFF T O THE SWITCHGEAR PANEL IS FACILITATED CABLE LAID ON SUPPORTING ANGLE IN CABLE TRENCHES STRUCTURES COLUMNS AND VERTICAL RUN OF CA BLE TRAYS SHALL BE SUITABLY CLAMPED BY MEANS OF G I SADDLES CLAMPS WHEREAS CABLE IN HORIZONTAL RUN OF CABLE TRAYS SHALL BE TIED BY MEANS OF NYLON CORDS THE CONTRACTOR SHALL OPEN NORMALIZE CABLE TRENCH MANHOLE COVERS AFTER THE WORK TO THE ORIGINAL STATUS TERMINATION GLANDING PVC CABLES LAID WILL BE GLANDED ON BOTH THE ENDS THEY SHALL HAVE A GLAND OF SCREWED NIPPLE WITH CONDUIT ELE CTRICAL THREADS AND CHECK NUT BOQ SL NO ITEM DESCRIPTION UNIT QTY 1 LAYING TERMINATION DRESSING OF 4C X 6 SQ MM CU ARMOR ED CABLE THROUGH EXISTING CABLE TRAYS LADDERS FROM 400KV GIS LCC PANEL TO GT11 PROTECTION PANEL FIRST FLOOR METER 425 2 LAYING TERMINATION DRESSING OF 4C X 6 SQ MM CU ARMORED CABLE THROUGH EXISTING CABLE TRAYS LADDERS FROM 400KV GIS LCC PANEL TO GT12 PROTECTION PANEL FIRST FLOOR METER 425 3 LAYING TERMINATION DRESSING OF 4C X 6 SQ MM CU ARMORED CABLE THROUGH EXISTING CABLE TR AYS LADDERS FROM 400KV GIS LCC PANEL TO GT13 PROTECTION PANEL FIRST FLOOR METER 425 4 LAYING TERMINATION DRESSING OF 4C X 6 SQ MM CU ARMORED CABLE THROUGH EXISTING CABLE TRAYS LADDERS 2 RUNS OF 30 METERS FROM 6 6KV SWITCH GEAR PANEL TO GT11 PROTEC TION PANEL FIRST FLOOR METER 60 5 LAYING TERMINATION DRESSING OF 4C X 6 SQ MM CU ARMORED CABLE THROUGH EXISTING CABLE TRAYS LADDERS 2 RUNS OF 30 METERS FROM 6 6KV SWITCH GEAR PANEL TO GT12 PROTECTION PANEL FIRST FLOOR METER 60 6 LAYING TERMINATION DRESSING OF 4C X 6 SQ MM CU ARMORED CABLE THROUGH EXISTING CABLE TRAYS LADDERS 2 RUNS OF 30 METERS FROM 6 6KV SWITCH GEAR P ANEL TO GT13 PROTECTION PANEL FIRST FLOOR METER 60 NOTE GLANDING OF 4CX6SQMM CU ARMORED CABLES INCLUDES SUPPLIES OF SUITABLE B RASS CABLE GLAND INSULATION SLEEVES FASTENERS ETC SUPPLY OF CABLE IS NOT IN THE SCOPE OF WORK Qty 1Cable Laying and Termination is Required for Protection System up gradation for D Rep Units d11 d12 d13 as Per Generationprotection Code Recommendation STANDARD TERMS CONDITIONS1 Prices should be DDP delivery duty paid at DEWA stores 2 Quotation to be submitted only in local currency U A E Dirhams3 DEWA Standard payment terms is 30 days credit from the date of acceptance of material4 No DEWA staff or his or her relatives up to third degree should have ownership or partnership in your company and your participation in DEWA tenders RFQs should not constitute a Conflict or perceived Conflict of Interest

Key Value

Tender Value
Refer document

Attachment

FileName File Description
Global Tender Document Tender Notice
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail