81 Container Shipping

Tender Detail

31546637
SPRPA120RW350
Self Funded
81 Container Shipping
ICB
Northern America
Asia-Pacific Economic Cooperation, APEC,G20
22-07-2020

Work Detail

Item Unique Identification And Valuation Mar 2016 19 Higher Level Contract Quality Requirement 8 Mil I 45208 Or Higher Time Of Delivery June 1997 20 Desired And Required Time Of Delivery June 1997 29 0001 10 180 Days Stop Work Order Aug 1989 1 Wide Area Workflow Payment Instructions Dec 2018 16 Invoice And Receiving Reports Combo Source Tbd Sprpa1 Tbd Tbd Tbd Tbd Navy Use Of Abilityone Support Contractor Release Of Offeror Information 3 18 2 Value Engineering Jun 2020 3 Equal Opportunity Sep 2016 2 Small Business Subcontracting Plan Dod Contracts Basic Dec 2019 2 Integrity Of Unit Prices Jun 2020 1 Equal Opportunity For Veterans Jun 2020 4 Warranty Of Supplies Of A Noncomplex Nature Jun 2003 6 365 Days 45 Days After Discovery Of Defect Small Business Subcontracting Plan Aug 2018 Deviation 2018 O0018 5 Daria Wilson Dla Mil Equal Opportuity For Workers With Disabilities Jun 2020 2 Transportation Of Supplies By Sea Feb 2019 2 Buy American Free Trade Agreements Balance Of Payments Program Dec 2017 5 Limitation Of Liability High Value Items Feb 1997 1 Alternate A Annual Representations And Certifications Apr 2020 13 Buy American Free Trade Agreements Balance Of Payments Program Certificate Nov 2014 5 Buy American Balance Of Payments Program Nov 2014 1 Royalty Information Apr 1984 1 Annual Representations And Certifications Mar 2020 13 332439 500 Representation Regarding Certian Telecommunications And Video Sureillanceservices Or Equipment Aug 2019 2 Facsimile Proposals Oct 1997 1 Notice Of Priority Rating For National Defense Emergency Preparedness Andenergy Program Use Apr 2008 2 Do A8c Offerors Are Advised That Offers Received From Sources Which Are Not Government Approved Sources Of Supply Will Be Deemed Technically Unacceptable And Therefore Ineligible For Award Any Distributors Of Approved Source S Must Submit A Copy Of Their Authorized Distributor Letter On The Source s Letterhead To The Buyer Point Of Contact Indicated On The Solicitation Via Email At Time Of Proposal Submittal 1 Scope When Discrepancies Exist Between These Requirements And Those On The Current Manufacturer s Drawings Contact The Contracting Officer Listed On Page 1 Block 5 Of The Contract 1 1 Pre Award Post Award Requirements Due To The Critical Use Of This Item And Its Quality History A Pre Award Survey And Post Award Conference May Be Required For All New Manufacturers For All Previous Sources A Post Award Conference May Be Recommended 1 2 Container Shell Material Is Aluminum 1 3 Articles To Be Furnished Hereunder Shall Be Manufactured Tested And Inspected In Accordance With Champion Company Drawing Number 94231 20140 Revision Latest And All Details And Specifications Referenced Therein 1 4 Unless Expressly Provided For Elsewhere In This Clause Equipment Such As Fixtures Jigs Dies Patterns Mylars Special Tooling Test Equipment Or Any Other Manufacturing Aid Required For The Manufacture And Or Testing Of The Subject Item S Will Not Be Provided By The Government Or Any Other Source And Is The Sole Responsibility Of The Contractor The Foregoing Applies Notwithstanding Any Reference To Such Equipment Or The Furnishing Thereof That May Be Contained In Any Drawing Or Referenced Specification 1 5 The Use Of Mil W 81381 Wire In Any Item To Be Delivered Under This Procurement Is Prohibited The Foregoing Prohibition Applies Notwithstanding Any Reference To Mil W 81381 Wire That May Be Made In Any Of The Drawings Or Specifications For This Procurement Sae As22759 Latest Revision Series Wire Shall Be Used Inlieu Of Mil W 81381 Wire In Any Place Where Mil W 81381 Wire Is Cited In This Procurement Any Questions Concerning This Requirement Should Be Directed To The Procuring Contracting Officer 1 6 If Mil Std 454 Is Referenced In The Drawings Or In The Specification The Contractor Is Expected To Show Compliance With Ipc Eiaj Std 001C 2 Applicable Documents Not Applicable 3 Requirements Contact The Contracting Officer Listed On Page 1 Block 5 Of The Contract For Test Facility Location When A First Article Is Required The Contractor Shall Submit A Copy Of The Drawings Contracts And Approved Eco s Deviations Waivers And Modifications In The Records Receptacle Of The First Article Container Welding And Welder Qualifications Shall Meet Current Aws D1 2 Standards Additionally Cleaning Preparations Shall Be In Accordance With Mil C 5541 And The Cleaning Paragraph Located In The Welding Requirement Section Of The Contract 3 1 One Third 1 3 Unit Of Desiccant Mil D 3464 Type Ii Nondusting Per Cubic Foot Of Container Interior Volume Shall Be Placed In Desiccant Holder Of Each Container At Time Of Shipment 3 2 At Faying Surfaces Discontinuous Welds Or Other Areas Where Atmospheric Liquids May Be Retained By Capillary Action The Crevice Shall Be Sealed Using Sealing Compound Mil S 81733 Or Equivalent 3 3 Reference To Cadmium Plating Shall Be Deleted And The Following Substituted Finish Shall Be Electrodeposited Alkaline Zinc Nickel Alloy In Accordance With Astm B 841 Class 1 Type B Grade 3 3 4 The Shock Mount Listed In The Drawing Package Whether Identified As Sole Source Recommended Or Suggested Has Been Tested And Approved For The Shock Mitigation System Of This Container No Other Shock Mount May Be Substituted Without Written Permission Of Naval Inventory Control Point Philadelphia Unless An Alternate Is Specifically Indentified In This Contract No Other Mount Is An Approved Alternate Mount All Containers Must Be Affixed With A Nameplate That Includes A Unique Identification Uid Marking As Referenced In The Drawing Package Drawing 80132 15930 And Iaw Mil Std 130 Latest Revision The Contractor Shall Contact Navicp Code N241 17 And Contracting Officer Listed On Page 1 Block 5 Of The Contract Or Code 0771 10 For The Alphanumeric Sequential Serial Number Group That Makes Up Part Of The Uid The Uidwill Be Included On The Nameplate In Data Matrix Format 3 5 Welding And Welder Qualifications Shall Be In Accordance With Aws D1 1 For Steel Aws D1 2 Or Mil W 22248 Class 4 For Aluminum Aws D1 3 For Sheet Steel And Aws D1 6 For Stainless Steel Proper Controls Shall Be Used To Prevent Melt Through Or Burn Through For Aluminum Filler For Welding 6061 Alloy Shall Be 4043 Filler For Welding 5000 Series Alloys To Themselves Or To 6061 Shall Be 5356 Or 5556 In Addition Welding And Weld Inspection Shall Include 1 Visual Inspection Shall Include 5X 5Power Magnification When A Suspect Condition Is To Be Examined Beyond The Capability Of Normal Vision 2 Critical And Major Welds May Be Subjected To Further Non Destructive Testing Such As Dye Penetrant Inspection As Prescribed By The Buying Activity 3 Proper Documentation Shall Be Available For Review By Government Personnel 3 6 Work Instructions Work Instructions Shall Be Posted At Theoperator s Work Station Giving Procedures To Control The Welding Process I E Filler Material Weld Size Electrical And Gas Characteristics Including Flow Rate 3 7 Materials And Materials Control The Quality Program Shall Assure That The Materials Used In Fabrication Or Processing I E Base Metals And Weld Filler Material Be Inspected And Conform To The Applicable Physical Chemical And Other Technical Requirements Supplier s Certification Is Sufficient 3 8 Controls Weld Filler Materials Shall Be Clearly Identified And Segregated From Each Other Both When In Storage And At The Work Station Work Station Environment Shall Be Controlled To Prevent Conditions Adverse To Proper Gas Shielding 3 9 Cleaning Parts To Be Welded Shall Be Cleaned To Remove Surface Soils Such As Oils Waxes Grease Inks Etc Except That Uninhibited Alkaline Solutions Such As Sodium Hydroxide Shall Not Be Used 3 10 Deoxidizing The Cleaned Parts Shall Be Chemically Deoxidized No More Than 10 Days Prior To Welding To Remove Thick Surface Oxide Films If The Material Or Work Is Exposed To An Outdoor Environment This Time Limit Shall Be Reduced To A Maximum Of 3 Days To Account For Atmospheric Effects Mechanical Cleaning Methods Shall Be Applied Just Prior To The Actual Start Of Welding To Remove Any Reoxidation Or Residual Thin Oxide Films 3 10 1 Chemical Treatment An Acid Deoxidizing Treatment Shall Be Applied By Either Immersion Or Brushing Wiping Deoxidizers Acceptable For Use Shall Include Nitric Acid Sulfuric Chromic Phosphoric Chromic Or Equivalent Solutions Sodium Hydroxide Solutions Shall Not Be Used Care Shall Be Taken To Assure 100 Solution Coverage Of The Area To Be Welded To Allow An Adequately Sized Deoxidized Area For Good Welding The Solution Shall Be Applied To An Area Extending At Least 2 Inches From The Weld Site Or Ending At Any Closer Adjacent Edge 3 10 2 Mechanical Means Immediately Prior To Welding Mechanical Cleaning Methods Shall Be Applied To The Weld Areas Previously Chemically Treated To Assure Removal Of Residual Or Reformed Oxides If Any Acceptable Methods Of Mechanical Cleaning Include Stainless Steel Wire Brushing Scraping Filing Or Sanding However Abrasives Containing Iron And Its Oxides Steel Wool And Wire And Copper Alloy Based Wire Which May Become Embedded With Galvanically Active Metals And Accelerate Corrosion Of Aluminum Alloys Shall Not Be Used Mechanical Methods Shall Be Vigorous Enough To Adequately Remove Any Residual Oxide Films But Gentle Enough To Avoid Forming An Excessively Rough Surface In The Comparatively Soft Metal Underneath 4 Quality Assurance 4 1 The Tests To Be Performed Under The First Article Approval Clause Far 52 209 4 Of The Contract Are Listed Below 4 1 1 Dimensional Test Special To Drawing 94231 20140 And Subdrawings Is Applicable 4 1 2 Requirements Of To Drawing 94231 20140 And Subdrawings Is Applicable 4 1 3 Form Applies 4 1 4 Fit Applies 4 1 5 Function Per 100 Production Leak Test 4 1 6 Compliance With Drawing 94231 20140 Revision Latest And Specifications Referenced Therein 4 2 In Addition To The Above Tests The First Article S To Be Delivered Hereunder Shall Also Be Subjected To Those Tests Which Will Demonstrate That The Article S Comply With Contract Requirements Requirements 4 3 The Contractor Shall Be Responsible For Providing The Necessary Parts And Repair Of The First Article Sample S During Testing 4 4 The Cost Of The Government Testing Effort Set Forth In This Solicitation Is Estimated To Be 12 000 For The First Article Testing This Cost Factor Will Be Added For Solicitation Purposes To The Price Of All Offerors For Whom The Government Will Require Such Testing 4 5 Disposition Of Fat Samples 4 5 1 Zero Sample S Shall Not Be Returned To The Contractor Because They Shall Be Destroyed During Testing 4 5 2 All Unless Otherwise Provided For In The Contract Sample S Shall Be Returned To The Contractor And May Be Considered As Production Items Under The Contract Provided The Sample S Can Be Refurbished To Ready For Issue Condition And Provided The Sample S Have Inspection Approval From The Cognizant Dcmc Qar Sample S May Be Shipped As Production Items Only After All Other Units Required Under The Contract Have Been Produced And Are Ready For Shipment N A Sample S Shall Be Returned To The Contractor But Shall Not Be Considered As Production Due 4 6 Test Sample Coating Instructions 4 6 1 Samples Are To Be Unpainted Corrosive Areas Are To Be Coated With A Light Preservative This Paragraph Does Not Apply To Shipping Containers 4 7 Fat Approval Criteria 4 7 1 Far 52 209 4 Applies A The Contractors Shall Deliver One 1 Unit S Of The Following Cage 94231 Part Number 20140 Revision Latest Within 90 Calendar Days From The Date Of This Contract To The Government At Test Facility Addresses Naval Air Warfare Center Aircraft Division Highway 547 Building 271 Lakehurst Nj 08733 Nswc Indian Head Division Detachment Picatinny Building 458 Whittemore Ave Picatinny Arsenal Nj 07806 5000 Marking Of Test Sample S Shipping Container Shall Be As Follows Citing This Contract Number For First Article Testing Not Rfi Material Do Not Take Up In Stock Contract Number For First Article Test The Shipping Documentation Shall Contain This Contract Number And Lot Item Identification The Characteristics That The First Article Must Meet And The Testing Requirements Are Specified Elsewhere In This Contract B Upon Shipment Of First Article Sample S Two 2 Copies Of The Material Inspection And Receiving Report Dd Form 250 Bearing The Qar s Signature And Indication Of Preliminary Inspection Shall Be Forwarded To The Navicp Philadelphia Code Cited In Block 10 A Of Sf33 With Duplicate Copies To Navicp Code 072 And To The Designated Test Facility The Envelopes Shall Be Clearly Marked Do Not Open In Mail Room Within 60 Days After Receipt Of The Samples The Test Site Shall Complete Testing Evaluation And Submit Two 2 Copies Of Their Test Report With Conclusions And Recommendations To The Navicp Code Cited In Block 10 A Of The Sf33 C Within 60 Calendar Days After The Government Receives The First Article The Contracting Officer Shall Notify The Contractor In Writing Of The Approval Conditional Approval Or Disapproval Of The First Article The Notice Of Approval Conditional Approval Or Disapproval Shall Not Relieve The Contractor From Complying With All Requirements Of The Specifications And All Other Terms And Conditions Of This Contract A Notice Of Conditional Approval Shall State Any Further Action Required Of The Contractor A Notice Of Disapproval Shall Cite Reasons For Disapproval D If The First Article Is Disapproved The Contractor Upon Government Request Shall Submit An Additional First Article For Testing After Each Request The Contractor Shall Make Any Necessary Changes Modifications Or Repairs To The First Article Or Select Another First Article For Testing All Costs Related To These Tests Are To Be Borne By The Contractor Including Any And All Costs For Additional Tests Following A Disapproval The Contractor Shall Furnish Any Additional First Article To The Government Under The Terms And Conditions And Within The Time Specified By The Government The Government Shall Act On This First Article Within The Time Limit Specified In Paragraph B Above The Government Reserves The Right To Require An Equitable Adjustment Of The Contract Price For Any Extension Of The Delivery Schedule Or For Any Additional Costs To The Government Related To These Tests E If The Contractor Fails To Deliver Any First Article On Time Or The Contracting Officer Disapproves Any First Article The Contractor Shall Be Deemed To Have Failed To Make Delivery Within The Meaning Of The Default Clause Of This Contract F Unless Otherwise Provided In The Contract The Contractor 1 May Deliver The Approved First Article As Part Of The Contract Quantity Provided It Meets All Contract Requirements For Acceptance And Was Not Consumed Or Destroyed In Testing And 2 Shall Remove And Dispose Of Any First Article From The Government Test Facility At The Contractors Expense G If The Government Does Not Act Within The Time Specified In Paragraph B Or C Above The Contracting Officer Shall Upon Timely Written Request From The Contractor Equitably Adjust Under The Changes Clause Of This Contract The Delivery Or Performance Dates And Or The Contract Price And Any Other Contractual Term Affected By The Delay H The Contractor Is Responsible For Providing Operating And Maintenance Instructions Spare Parts Support And Repair Of The First Article During Any First Article Test I Before First Article Approval The Acquisition Of Materials Or Components For Or The Commencement Of Production Of The Balance Of The Contract Quantity Is At The Sole Risk Of The Contractor Before First Article Approval The Costs Thereof Shall Not Be Allocable To This Contract For 1 Progress Payments Or 2 Termination Settlements If The Contract Is Terminated For The Convenience Of The Government J The Contractor Shall Produce Both The First Article And The Production Quantity At The Same Facility And Shall Submit A Certification To This Effect With Each First Article K The Contractor Shall Provide Specific Written Notification To The Procuring Contracting Officer Informing Him Her Of The Shipment Of Any Article S Furnished In Accordance With This Clause Such Notification Must Be Addressed To The Attention Of The Navicp Code Specified In Block 10 A Of The Sf33 With Copies To Navicp Code 072 And To The Testing Activity Failure To Provide Such Notification Shall Excuse The Government From Any Delay In Performing First Article Testing And Informing The Contractor Of The Results Thereof L Fourteen 14 Days Prior To Shipment Of First Article Samples The Contractor Shall Notify The Designated Test Facility In Writing Of The Anticipated Shipping Date With An Information Copy To The Pco Navicp Philadelphia Attn Cite Code Found In Block 10 A Of The Sf33 The Contractor Shall Also Arrange For Preliminary Inspection Of Test Samples By The Dcmc Qar 4 8 Alternate Offers Waiver Of First Article Approval Requirements The Following Provisions Supersede Any Waiver Of First Article Approval Requirements Terms Set Forth In Clause 52 209 3 Or 52 209 4 As Appropriate A Unless Otherwise Specified In The Solicitation The Naval Inventory Control Point Reserves The Right To Waive The First Article Approval Requirements Specified Herein For Offerors Who Have Previously Furnished Identical Production Articles Accepted By The Government Or The Original Equipment Manufacturer Prime Manufacturer An Offeror Requesting Waiver Of First Article Requirements Shall Submit Evidence With Its Offer Establishing That I The Last Production Unit Was Delivered Within Three 3 Years Of The Issue Date Of This Solicitation And Ii The Production Location To Be Used For This Requirement Is The Same As Used For The Previous Production Run Additionally The Offeror Shall Submit A Certification To Be Executed By The Officer Or Employee For The Offer Stating That I The Articles To Be Provided Will Be Produced Using The Same Facilities Processes Sequences Of Operations And Approved Subcontractors As Those Previously Delivered And Accepted By The Government Or The Original Equipment Manufacturer Prime Manufacturer And Ii The Previous Production Units Were Manufactured Without Material Review Board Disposition Or Waiver Deviation Request Or Rejection Of Pre Production Samples For Cause Note This Certification Concerns A Matter Within The Jurisdiction Of An Agency Of The United States And The Making Of A False Fictitious Or Fraudulent Certification May Render The Maker Subject To Prosecution Under Title 18 United States Code Section 1001 B Offerors Requesting Waiver Of First Article Approval Requirements Under The Provisions Of This Clause Are Cautioned To Submit Two Prices For Articles Required Herein One That Is Based On Compliance With The First Article Approval Requirements And One That Is Based On A Waiver Of Such Requirements Where An Offeror Submits Only One Price And Fails To Clearly State That The Price Is Based On Waiver Of The First Article Approval Requirements It Will Be Deemed To Be Based On Compliance With The First Article Approval Requirements C In The Event Of The First Article Approval Requirement Is Granted The Delivery Schedule For The Production Items Shall Be Reduced By The Number Of Days Designated For Delivery Of First Article Test Unit Plus The Number Of Calendar Days Indicated For The Government Notification Of Conditional Approval Or Approval These Requirements Are Specified In The Quality Assurance Section Of This Solicitation If The Offeror Is Unable To Meet The Desired Schedule He Shall Insert Below The Alternate Delivery Schedule He Offers To The Government Offeror s Proposed Alternate Delivery Schedule Based On Waiver Of First Article Approval Requirements Within Days Item No Quantity After Date Of Contract 4 9 100 Production Leak Test Each Container Uninstrumented And Without Dummy Load Shall Be Raised To A Height Of 18 Inches And Allowed To Fall Freely To A Concrete Or Similarly Hard Surface Landing Flat On Its Base The Container Shall Then Be Prepared For Testing By Sealing All Breathing Devices And Inserting Suitable Pressurized Fittings And Gauges The Container Shall Be Closed And Sealed In A Normal Manner The Pneumatic Pressure Technique Of Method 5009 Of Federal Test Method Standard No 101C Shall Be Used To Detect Leakage An Initial Pressure Setting Equal To 1 0 0 1 0 Psig Shall Be Used After Stabilization Pressure Shall Be Monitored For Thirty Minutes Any Loss In Pressure In Excess Of 0 05 Psig Adjusted For Changes In Temperature And Barometric Pressure Shall Be Cause For Rejection Warning Container May Explode Or Fasteners May Fail During Test Use Protective Barriers To Avoid Injury To Personnel 5 Packaging Mil Std 2073 Packaging Applies As Found Elsewhere In The Schedule 6 Notes Not Applicable

Key Value

Tender Value
Refer document
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail