Lma Workboat

Tender Detail

29299832
W912EF20B0014
Self Funded
Lma Workboat
ICB
Northern America
Asia-Pacific Economic Cooperation, APEC,G20
23-04-2020

Work Detail

View Changes The Us Army Corps Of Engineers Walla Walla District Is Issuing A Solicitation For The Purchase Of A Workboat Non Commercial Supply Prepared In Accordance With Federal Acquisition Regulation Part 14 The Naics Code Applicable To This Acquisition Is 336612 With A Small Business Size Of 1 000 Employees As Determined By 13 Cfr 121 104 Competition For This Requirement Is Unrestricted In Accordance With Far 19 502 2 B 1 Before Setting Aside An Acquisition Under This Paragraph Refer To19 203 C The Contracting Officer Shall Set Aside Any Acquisition Over 150 000 For Small Business Participation When There Is A Reasonable Expectation That 1 Offers Will Be Obtained From At Least Two Responsible Small Business Concerns Offering The Products Of Different Small Business Concerns See Paragraph C Of This Section The Government Is Not Confident That Responsive Bids Will Be Received From Two Or More Small Business Fabricators When Available The Solicitation Documents For This Project Will Be Provided Under Solicitation W912ef20b0014 The Agency Estimates That The Solicitation Will Be Available On Or Around07 April2020 Please Do Not Submit An Offer Without The Solicitation Package That Will Be Provided To Industry By The Government The Solicitation Will Be An Inquiry For Bid The Official Bid Due Date Will Be Contained Within The Solicitation And Any Solicitation Amendments That May Be Issued Of The Requirement This Acquisition Requires The Manufacture Outfitting And Delivery Of One New All Steel Twin Diesel Engine Powered Propeller Driven Truckable Towboat Workboat Ready For Freshwater Operation The Contractor Shall Provide All Labor Material Equipment And Engineering Necessary To Build And Deliver A Boat As Required By This Acquisition Scope The Vessel Shall Comply With All Current U S Coast Guard Regulations For Uninspected Towing Vessels Us Army Corps Of Engineers Safety Manual Em 385 1 1 Section 19 And Federal And State Environmental Requirements With Respect To A Vessel S Function Construction And Equipment Outfitting The Vessel Shall Be Newly Manufactured And Shall Be Built Entirely Of Steel By A Proven Manufacturer Regularly Engaged In The Manufacture Of Truckable Welded Steel Towboats A Custom Built Boat Is Not Necessarily Intended And Modifications To A Stock Model Design Is Encouraged The Vessel Is To Be Used As A Push Boat In A Fresh Water Environment And Shall Reflect That Type Of Construction Inside And Out The Vessel s Hull Shall Be Properly Reinforced For Operations On Inland Waterways Of The Snake River In The Pacific Northwest The General Layout Of The Vessel Shall Incorporate A Fully Enclosed Pilot House Engine Room Access Hatches And A Walking Space All Around The Outside Of The Vessel The Engines Shall Be Installed Under The Deck In A Separate Watertight Compartment A Watertight Tank Compartment Or Lazarette Shall Be Aft Of The Engine Compartment To Suit Trim Of The Vessel The Pilot House Shall Have A Watertight Access Door To The Outside The Pilot House And Deck House Shall Have Windows On The Forward Aft Port And Starboard Sides All Welding Shall Be Accomplished In Accordance With The Recommendations Of The Manufacturer Of The Material Used In The Construction Of The Vessel All Sharp And Or Rough Edges Shall Be Ground Round And Smooth And All Weld Splatter And Slag Shall Be Removed All Exterior Seams And Butts Shall Be Flush And Smooth And The Hull Plating Shall Be Shrunk As Required To Remove All Ripples And Make Fair Workboat Minimum Requirements Hull Length 25 Feet Maximum Width 12 14 Feet Draft 5 Feet Minimum Freeboard 24 Fully Loaded In Fresh Water Material Astm A 36 Steel Shell Plating 1 4 Steel Plate Minimum Bulwarks Continuous All Around Hull Handrail Port Starboard And Aft Of The Vessel Port And Starboard Handrail Shall Have A 36 Opening For Loading And Offloading Personnel With 2 Lengths Of Stainless Steel Chain Between The Openings Rub Bars Down Each Side Of Hull Bulkheads Two Watertight Transverse Bulkheads Shall Be Installed One Forward Of The Engine Room And One Aft Of The Engine Room Hatches Watertight Hatches In Deck Two Into Engine Compartment And One Into Forward Compartment In Engine Room One Watertight Hatch In Forward Collision Bulkhead Into Forward Compartment And One Watertight Hatch In Aft Bulkhead Into Aft Rudder Ballast Compartment Push Knees Push Knees Shall Be 9 Feet Overall Height Faced With A Minimum Of 2 Inch Thick Rubber Pads Bitts One 5 Inch Minimum Od Double Towing Bitt Aft One 4 Inch Od Single Head Bitt Forward And Four 4 Inch Od Single Quarter Bitts Head Bitt And Tow Bitt Must Penetrate Deck And Be Welded To The Hull Lifting Eyes Four Permanent Eye Straps Welded To The Hull Suitably Sized For Lifting The Vessel Picking Lifting Eyes Are Also Required On The Pilothouse And Superstructure Section If Equipped To Ensure The Truckable Capability Of The Vessel Ensure Handrail Is Not Impacted By Picking Of The Vessel Winches Two Main Deck 5 Ton Wire Winches Bow Mounted Anodes Shall Be Installed On Hull Below The Waterline Paint All Plates And Shapes Shall Be Blasted And Coated With A Pre Construction Primer Exterior Hull Decks And Pilot House Shall Be Coated With Two Part Epoxy Anti Corrosive Steel Primer International Coatings 300V Or Equivalent Hull Decks And House Shall Then Be Coated With One Coat Of International Interthane 990 Or Equivalent Marine Topcoat Engine Room Shall Be Coated With Two Part Epoxy Topcoat Non Skid Shall Be Applied To The Main Deck And Top Of Engine Cover And Flying Bridge The Paint System Shall Be Formulated For The Marine Environment And Have Superior Anti Corrosive Coverage And Impact Resistance Properties Colors Hull Black Superstructure White Decks And Engine Room Gray Anti Fouling Coating Shall Be Applied To The Hull With International Interspeed 6400Na Red In Color Or Equivalent Pilot House Floor Height Pilothouse Deck Must Be A Minimum Of 7 From Water Level At Maximum Draft Eye Level Minimum Of 12 Standing Inside The Pilothouse Handrail Shall Be Installed On The Stairs And Elevated Platform Leading Into The Pilothouse Entry Door Watertight Steel Door Windows Stationary Front Window Shall Be Tilted Forward With Windshield Wiper Horizontal Sliding Side Windows Vertical Sliding Rear Windows With One Mounted In The Pilot House Door All Windows Made Of Tempered Safety Glass Pilot House Windows Shall Be Tinted In Accordance To Coast Guard Specifications Supplemental Heating Required Heat May Be Supplied By Engine Cooling System Or Optional Electrical Generator Set Propulsion Machinery Two Diesel Engines 300 Hp Minimum Each Operated At An Intermediate Duty Rating Mounted On Vibration Isolators Engine Room Ventilation External Air To Engine Room Two J Box Vents Exhaust Must Be Heat Insulated In Engine Room Exposed Exhaust Pipes Top Side Must Be Guarded Against Accidental Touching Exhaust Pipes Shall Extend Above The Pilothouse And Not Impede The View Of The Pilot Exhaust Shall Be Muffled Similar To Automotive Standards Transmission Two Twin Disc 1 Speed Forward And 1 Speed Reverse Reduction Gears Or Approved Equal With Minimum 2 Stainless Steel Propeller Shafts Unless Otherwise Recommended Engine Cooling Engine Shall Be Cooled By Keel Coolers Size Determined By Manufacturer Recommendation For Operating In Water Temperature Up To 78 Degrees Steering Two Hydraulic Pumps One Driven Off Each Engine Control Valve And Flow Regulator Mounted In Engine Room Steering And Jog Stick Provided In The Pilothouse Controls Engine Controls Shall Be Located In The Pilothouse Start Stop Emergency Engine Shutdown Controls Shall Be Located In Engine Room And Pilothouse Propellers 4 Blades Per Propeller With A Minimum Of 30 Diameter Shaft Seals Dripless Mechanical Shaft Seals Or Equivalent To Meet Industry Standards Rudders Two Main Steering Rudders And Four Flanking Rudders Rudder Skegs Must Support Full Weight Of Boat To Protect Rudders Propellers Propeller Guards Vessel Shall Be Equipped With A Propeller Rudder And Shaft Guard Stump Jumper For Both Port And Starboard Propellers Guard Design Shall Be Submitted For Review And Approval Prior To Fabrication And Installation Fuel Tank Minimum Of 350 Gallons With Emergency Fuel Shut Off Above The Weather Deck Engine Access Shipping Access To Engine Room Must Be Large Enough To Remove Engines And Be Watertight When Closed Instrumentation Amp Electronics Rudder Angle Indicators For Both Standard And Flanking Rudders Engine Tachometer Oil Pressure Water Temperature And Volt Meter For Each Engine In Pilothouse And In Engine Room Audible And Visual Alarm For Low Oil And High Temperature Coolant Tank And Fuel Tank Level Indicators 12 Volt Electric Or Air Signal Horn Per Colregs 72 Inland Rules Vhf Marine Radio With Hailer And Antenna Depth Sounder With A Hull Mounted Transducer Lighting And Electrical Electric Batteries Two 12 Volt Heavy Duty 8D Marine Batteries Mounted In Coast Guard Approved Engine Room Battery Box Bilge Pump Minimum Of Four 12 Volt 1 200 Gph Pumps Two Shall Be Mounted In The Engine Compartment And One In Each Of The Other Two Compartments Led Lights Installed In The Pilothouse And Engine Room Two Aft Facing Led 500 Watt Equivalent Working Lights Two Forward Facing Led 500 Watt Equivalent Working Lights Navigation And Towing Lights Per Colregs 72 Inland Rules One 8 Inch Minimum Search Light Mounted On Pilothouse Safety Amp Security All Engine Room Vents Fitted With Solid Closing Flaps To Stop Air Flow Pilothouse And Engine Room All Lockable From Outside With Two Sets Of Keys Provided Drawings Must Provide 3 Sets Of As Built Drawings Of Hull Pilothouse Superstructure If Equipped Propeller Shafts Seals Propellers Rudders Fuel Hydraulic And Electrical Systems Showing Full Details Of The Construction Of The Vessel Trials The Vessel Must Undergo In Water Trials As Described Below The Trials Must Demonstrate That Hull Mechanical And Electrical Systems Function Properly And That The Vessel Meets Minimum Freeboard Requirements General The Trials Described In These Paragraphs Shall Be Conducted In The Presence Of The Contracting Officer Representative Cor Who Shall Be Notified Of The Date Set For The Trials At Least 10 Working Days In Advance Two Sets Of Trials Shall Be Conducted One Pre Delivery Conducted Near The Contractor S Build Site And One Post Delivery Near Starbuck Washington Should Any Defects Develop During The Trials The Contractor Shall Immediately Correct Deficiencies After Which The Boat Shall Again Be Operated Under The Same Working Conditions Until Found Satisfactory By The Cor Upon Completion Of The Trials The Contractor Shall Open For Inspection Such Items Of Machinery And Piping Which In The Opinion Of The Cor Have Demonstrated Indications Of Misalignment Need Of Adjustment Cleaning Or Other Preparation Attention For Satisfactory Performance The Contractor Shall Bear All Expenses Of These Trials Including The Furnishing Of All Necessary Instruments Scales Grease Supplies Lubricating And Fuel Oils And Mechanics Technicians And Operating Personnel The Test Data Consisting Of All Readings Taken Shall Be Compiled In A Log By The Contractor Two Copies Of The Logs And The Calculations And Results Of The Appropriate Data For The Vessel Shall Be Furnished To The Cor Subsequent To Preliminary Trials And Preliminary Acceptance By The Government The Contractor Shall Dry Dock The Vessel Or Provide Crane Support For Inspection Of The Underwater Hull Appendages By The Cor Subsequent To The Final Trials Near Starbuck Washington The Little Goose Crew Will Provide Crane Support To Conduct The Final Inspection Of The Underwater Hull Appendages By The Cor After Satisfactory Completion Of The Preliminary And Final Trials And Inspection Of The Completed Boat Acceptance By The Government Shall Be Made Dock Trials Upon Delivery And Assembly Of The Boat As Required By The Contract The Machinery Equipment And Appliances Shall Be Tested At The Site Of Delivery For A Continuous Period Of Not Less Than One Hour To Demonstrate Their Suitability For The Purpose Intended And To Check Installation And Make Adjustments The Propelling Engines Shall Be Operated At The Dock With As Much Load As Practicable For A Continuous Period Of No Less Than One Hour With No Unsatisfactory Performance Dock Tests Of All Installed Equipment Shall Be To The Satisfaction Of The Cor Operational Trials Free Running Following Satisfactory Completion Of The Dock Trials Specified Above The Boat Shall Be Operated For A Continuous Period Of Not Less Than Two Hours With No Engine Overheating Or Other Unsatisfactory Performances During This Time All Phases Of Engine And Steering Controls Shall Be Operated Through Their Full Range With The Vessel Fully Loaded Test Weights Shall Be Provided If Necessary To Simulate This Loading During This Trial The Boat Shall Be Operated For Periods Of Not Less Than 15 Minutes Each At Full Three Quarter Half And One Quarter Speeds As Well As Maneuvered From Hard Over To Hard Over Be Brought To A Crash Stop And Brought From Full Engine Speed Ahead To Full Engine Speed Astern And The Time Of Each Of The Maneuvers Recorded During Each Trial The Following Data At A Minimum Shall Be Recorded Rpm Of Each Propeller Time Over The Course Oil Pressure And Consumption Engine Jacket Water Temperature Other Data Required By The Cor Engine Data Shall Be Recorded Separately For Each Propulsion Engine In Addition To The Above Data For Each Trial The Following General Information Shall Be Furnished Outside Air Temperature Engine Room Temperature Hatch Closed Date Of Trials Signature Of Data Takers And Observers Pre Award Submittals The Contractor Shall Furnish Either Three Paper Copies Of A General Arrangement Plan And Profile Drawings Of The Pilothouse Helm Arrangement Decks Engine Room And All Major Equipment Layouts To The Contracting Officer As Part Of Their Proposal Delivery Fob Destination Safe And Timely Delivery Of The Workboat To Starbuck Washington The Little Goose Crew Will Provide Crane Support To Unload The Boat From The Trailer And Provide All Required Equipment Spreader Bars And Slings As Needed Warranty Builder To Warrant Workmanship And Equipment Installation For A Minimum Of One 1 Year Longer If Builder S Standard Practice Builder To Provide All Equipment And Materials Warranty Guarantee Documents To Purchaser At Point Of Delivery Delivery Requirement This Resultant Contract Will Require A Delivery Date Of No Later Than Six Months Following The Date Of Contract Award Important Note The Beta Sam Response Date Listed Elsewhere In This Synopsis Is For Beta Sam Archive Purposes Only It Does Not Necessarily Reflect The Actual Due Date That The Rfq Is Due No Cd s Or Hard Copies Will Be Available Offeror s Are Responsible For Checking The Reference Page For Any Update S To The Notice The Government Is Not Responsible For Any Loss Of Internet Connectivity Or For A Bidder s Inability To Access The Document Posted At The Referenced Website All Bids Received By The Closing Date Will Be Considered By The Government To Be Eligible For Contract Award Offerors Must Be Registered In The System For Award Management Sam Register Via The Sam Website At Https Www Sam Gov Or Contact Sam Customer Service At 866 606 8220 Offerors Must Also Complete Offeror Representations And Certifications On Line At Https Www Sam

Key Value

Tender Value
Refer document

Attachment

FileName File Description
Global Tender Document Tender Notice
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail