Tenders Are Invited For Supply Of Bop Control Unit

Tender Detail

22501946
STC 190827 OPS Y142
Self Funded
Tenders Are Invited For Supply Of Bop Control Unit
ICB
Western Asia
Arab World,Gulf Cooperation Council, GCC,Middle East,Middle East and North Africa, MENA
19-09-2019

Work Detail

Tenders Are Invited For Supply Of Bop Control Unit For Hoist Bop Control Unit Complete With Accessories Rated For Wp 3000 Psi 6 Station 5 1 Complete With Two 2 Remote Panels Hmi Plc Controlled And Hoses Cables Etc As Applicable Any Western Make Will Be Accepted If They Have Authorized Repair Facility In OmanSara Windlass Dongsu And Bpm Make Also AcceptableGeneral Specs1 Unit Shall Be Manufactured And Monogrammed In Accordance With Api Spec 16D Latest Edition 2 Unit Shall Be In Accordance With Ep 2002 1500 September 2008 Version And PdoSpecification Sp 1213 3 The Bop Control Unit Must Be Designed For Onshore Operation In Temperature Range 0 C To 55 CAmbient Temperature 4 All Electrical Equipment Of The Unit Should Comply With The North American ProtectionStandards Using Api Rp 500 Standards For Class1 Div 1 Group C D Operation 5 Unit Shall Be Mounted On Skid Complete With Roof And Spillage Drip Pan Of Sufficient Capacity The Roof Will Have Foldable Opening To Facilitate Removal Of Accumulator Bottles ForMaintenance Sufficient Lighting Including Minimum Of One Emergency Light Shall Be Provided Technical Specs1 Unit Shall Have 15 11 Gallon Bottles 2 Unit Shall Have Low Accumulator And Air Pressure And Low Reservoir Level Alarms AudibleAnd Visual With The Functionality To Function Test The Reservoir Low Level Fluid AlarmWithout Draining The Tank 3 Without Recharging The Unit Shall Be Capable Of Closing And Opening All Preventers Opening Hydraulic Choke Line Valve And Closing Again The Blind Shear Ram AfterCompletion Of Above Operations The Remaining Accumulator Pressure Shall Be 200 PsiAbove The Accumulator Pre Charge Pressure The Accumulator Pressure After ClosingOne Annular And All Pipe Ram Including Shear Ram Shall Be Adequate To Keep The PipeRam Closed Against A Wellbore Pressure Equal To The Rated Working Pressure Of Bop 4 Calculation To Substantiate The Usable Accumulator Volume Must Be Provided 5 Annular Regulator Shall Be True Reading Type So Cannot Loose Air Setting Value WhenNo Air Pressure 6 All Regulator Including Annular Shall Be Rated To 0 3000 Psi 7 Bop Control Hydraulic Power Unit Hpu Shall Have A Suitably Sized Dedicated AirReceiver With A Non Return Valve Supplying Air To The Hpu 8 DrillerS Remote Control Panel And Tool Pusher Remote Control Panel To Have A Control Over All FunctionsB Graphic Panel Showing All Functions And ControlC Indicator Light To Show Function PositionD Pressure Regulator For Annular PreventerE Low Accumulator System Pressure WarningF Low Reservoir Level WarningG Low Rig Air Pressure WarningH Control For Bypass

Key Value

Tender Value
Refer document
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail