Tenders Are Invited For Supply Of Forklift Cat

Tender Detail

22501836
STC 190822 OPS Y137
Self Funded
Tenders Are Invited For Supply Of Forklift Cat
ICB
Western Asia
Arab World,Gulf Cooperation Council, GCC,Middle East,Middle East and North Africa, MENA
19-09-2019

Work Detail

Tenders Are Invited For Supply Of Forklift Cat 930K Forklift Model 930K Caterpillar 5 Ton With Quick Hitch Bucket PalletFork Jib Crane And Pipe Clamp Attachment Forklift Boom Attachment Should BeCapable Of Lifting 1 5 Metric Ton To A Height Of 5 M And Suitable To Operate In DesertConditions And In Explosion Proof Zones Forklift Should Be Capable Of Lifting AMinimum Of 2 Tons At 3M Extension Unit Should Be Installed With Spark ArrestorAnd Rated For 55C Ambient Temperature The Forklift Should Also Satisfy RopRegulation And Pdo Standards The Following Features Are Required In The Unit 1 Lifting Boom Extension 2 Spark Arrestor 3 Manufacturer Supplied Load Hook Holes In Forks Are Not Acceptable 4 Functional Level Gauge 5 3 Points Seat Belt 6 Load Chart In The Cabin And On The Body Of The Forklift 7 Flashing Light Alarm On Forklift 8 Rollover Protection Along With Overhead Guard 9 Mechanical High Lift Stop 10 Label Displaying The Type Of Fuel Gasoline Diesel 11 Speed Limit Sign And Fasten Seat Belt Sign To Be Posted 12 Locking Pin For Forks Or Other Attachments 13 Stop Lugs At The End Of The Lateral Beam To Avoid Dropping Fork 14 Working Lights 15 Rear View Or Panoramic View Mirrors16 Forklift Certified To Operate In Ex Proof Zone 17 Swl Forklift Lifting Capacity To Be Adequately Displayed On Forklift 18 Horns Reverse Alarms Functional With Reverse Lights 19 Provisions To Be Made To Prevent Mechanical Over Travel Of Motions Such AsHoist Tilt Boom Etc 20 Battery Inside Ex Proof Battery Box Marked Battery 21 One Spare Tyre22 Carbon Monoxide Emission Should Be Less Than 55 Ppm From The Exhaust 23 All Electrical Installations Should Conform To Nfpa 70 Usa Standard And LocalOman Ordinance 24 Forklifts Shall Have All Required Arrangements To Connect A Pipe And Pole ForksTo Prevent Pipes Inadvertently Rolling Off The Forklift Optional Quote To BeProvided For Pipe And Pole Forks 25 Reversing Alarm 26 Visibility All Around Mirrors 27 Clear Markings Of Max Capacity 28 1 X 25 Pax First Aid Kit29 1 X Fire Extinguisher Powder Type In The Cabin

Key Value

Tender Value
Refer document
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail