Part I Of The Order: Thermal Modernization Of The Volunteer Fire Department Station In Gomunice. Part I Of The Order Covers The Performance Of Two Tasks, Including: Task 1: Construction Of A Monitoring System In The Building Of The Volunteer Fire Department Station In Gomunice - In The Design And Build System. The Task Includes In Particular: A) Development Of Design Documentation In Accordance With The Guidelines Contained In The Functional And Utility Program; B) Performance Of Works In Accordance With The Design Documentation; C) Supervision Over The Documentation By The Author Of The Project Design; D) Development Of Complete As-Built Documentation (Including, Among Others: Bills Of Quantities And Cost Estimates) (2 Copies Of The Paper Version And 1 Copy Of The Electronic Version); E) Fulfillment Of Obligations Arising From The Guarantee Granted For The Completed Subject Of The Order As Well As Arising From The Warranty. A Detailed Description Of The Facility In Question Can Be Found In The Functional And Utility Program Constituting Annex No. 11 To The Swz. Task 2: Thermal Modernization Of The Fire Station In Gomunice - In The Design And Build System. The Task Includes In Particular: 1. Development Of Design Documentation, Obtaining On Behalf Of The Ordering Party The Legally Required Decisions, Arrangements And Permits To Commence Construction And Operation Of The Investment. Construction And Executive Documentation Should Be Prepared In Accordance With The Provisions Of The Attached Functional And Utility Program Constituting Annex No. 11 To Swz.2. Execution Of Construction Works: - Insulating External Walls With 15 Cm Thick Polystyrene (Λ = 0.036W/M*K) Along With Construction Of A New Façade With Thin-Layer Plaster, - Replacement Of Window Frames With New Ones With A Heat Transfer Coefficient Of U = 0.9 W/M2*K, - Replacement Of Door Frames With New Ones With A Heat Transfer Coefficient Of U = 1.3 W/M2*K, - Modernization Of The Installation Domestic Hot Water By Using A Renewable Heat Source, I.E. An Electrically Driven Air/Water Compressor Heat Pump, - Modernization Of The Central Heating Installation. Through The Use Of A Renewable Heat Source, I.E. An Electrically Driven Air/Water Compressor Heat Pump And The Introduction Of Local Regulation In The Form Of Valves And Thermostatic Heads, - Use Of A 26 Kwp Photovoltaic Installation With An Energy Storage Capacity Of 30 Kwh.3. Preparation Of As-Built Documentation (Including Bills Of Quantities And Cost Estimates) In 2 Copies In Paper Version And 1 Copy In Electronic Version.4. Exercising Authors Supervision. A Detailed Description Of The Object In Question Can Be Found In The Functional And Utility Program Constituting Annex No. 11 To The Swz. Note: If References To Standards, European Technical Assessments, Approvals, Technical Specifications And Technical Reference Systems Are Used In The Swz Or Annexes, The Ordering Party Allows Solutions Equivalent To Those Described. When Analyzing T
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.