BRR 8660199
Tendering Authority Military Engineer Services
Tender No 8865/E8
Tender ID 2025_MES_740911_1
Tender Brief tender for repair and maintenance of summer appliances at afs hakimpet under ge (af) hakimpet; 2 taking down the window type air conditioner of capacity 1.5/ 2.0 tr carefully from the installed position,applying blower to remove the complete dust, cleaning all the components with caustic soda and other cleaning agent, combing the condensor coil wherever required and testing on completion complete
City hakimpet
State Telangana
Tender Value 29 Lakhs
Due Date 19-12-2025

Work Detail

tender for repair and maintenance of summer appliances at afs hakimpet under ge (af) hakimpet; 2 taking down the window type air conditioner of capacity 1.5/ 2.0 tr carefully from the installed position,applying blower to remove the complete dust, cleaning all the components with caustic soda and other cleaning agent, combing the condensor coil wherever required and testing on completion complete all as directed by engineer-in-charge. 3 servicing ofindoor/ outdoor unit of split type air conditioner of capacity 1.5/ 2.0 tr carefully from the installed position, applying blower to remove the complete dust, cleaning all the components with caustic soda and other cleaning agent , combing the condensor coil wherever required and testing on completion complete all as directed by engineer-in-charge. 4 taking down the evaporative type desert coolers of capacity upto 5000 cum/hr by disconnecting all the electrical connections cleaning all the components by removing the side panels and painting the coolers (for iron body/part only) withsinglecoat of synthetic enamel paint out side and moisture resistance primer inside with spray painting and fixing back the removed panel and reconnecting with electrical connections and writing the mes no complete all as directed by engineer-in-charge. 5 s & f in repairs including taking down of existing oldunserviceable spare parts of following cooling appliances complete all as specified and directed by engineer-in-charge:- 6 a)starting relay for water cooler of capacity upto 150 ltrs 7 b) starting relay for refrigerator of capacity upto 310 ltrs 8 c) thermostat for window type/ split type air conditioner of capacity upto 2.0 tr 9 d)thermostat for water cooler of capacity upto 150 ltrs 10 e) thermostat for refrigerator of capacity upto 310 ltrs 11 f) starting capacitor for window type/ split type air conditioner of capacity upto 2.0 tr 12 g)starting capacitor for water cooler of capacity upto 150 ltrs 13 h) running capacitor for window type/ split type air conditioner of capacity upto 2.0 tr 14 j)running capacitor for water cooler of capacity upto 150 ltrs 15 k)running capacitor for refrigerator of capacity upto 310 ltrs 16 l) capacitor for fan motor of window type/ split type air conditioner of capacity upto 2.0tr 17 m) blower motor suitable for existing model (invertor/ non invertor) of indoor unit of split type air conditioner of capacity upto 2.0 tr 18 n) indoor and outdoor coil sensors ( invertor/ non invertor) for split type air conditioners upto 2.0 tr 19 o) outdoor contact relay for split type air conditioners upto 2.0 tr 20 p) door beading for single and double door refrigerator/ water cooler of any size and capacity. 21 q) sealed compressor for 1.5 tr window/ split type air conditioner invetor or non invertor model including bracing the suction & discharge lines. make - carrier/whirpool/copeland or as existing make 22 r) sealed compressor for 2.0 tr window/ split type air conditioner invetor or non invertor model including bracing the suction & discharge lines. make - make - carrier/whirpool/copeland or as existing make 23 s) sealed compressor for 40/80 ltrs capacity water cooler including bracing the suction & discharge lines. make - lg/kirloskar/ericson or as existing make 24 t) sealed compressor for 150 ltrs capacity water cooler including bracing the suction & discharge lines. make - lg/kirloskar/ericson or as existing make 25 u) sealed compressor for upto 180 ltrs capacity refrigerator including bracing the suction & discharge lines.make - lg/kirloskar/ericson or as existing make 26 v) sealed compressor for above 180 ltrs and upto 310 ltrs capacity refrigerator including bracing the suction & discharge lines. 27 w) air filter cleanable, indigenous of suitable size for the split type air conditioners of capacity upto 2.0 tr 28 x) condensor fan blade set for the window/ split type air conditioners of capacity upto 2.0 tr 29 y) front panel (grill) suitable for existing model of split air conditioners outdoor unit of capacity upto 2.0 tr 30 z) nitrile tubing over gas circulating copper tubes for suction and discharge lines of split type air conditioner of capacity upto 2.0 tr 31 aa) pcb board unit suitable for existing make of split type air conditioners (invertor/ non invertor) of capacity upto 2.0 tr 32 ab) condensing coil copper for refrigerator 310 ltrs capacity 33 ac) copper tubes of suitable size for suction and discharge lines for split type air conditioners including necessary bracing and testing note: one run of suction, one run of dicharge shall be measures as one unit length. 34 ad) submersible water pump suitable for evaporative type desert coolers of capacity upto 5000 cum/hr 35 ae) khus khus pads/ honey pads of various model (set of 3 nos) for the evaporative desert coolers of capacity upto 5000 cum/hrs 36 af) pvc hose pipe alongwith necessaery fittings ad pvc distributor suitable for existing model of evaporative type desert cooler upto the capacity of 5000 cum/hr 37 ag) rotary/ piano type switch suitable for existing model of desert coolers of capacity upto 5000 cum/hr 38 ah) fan blade set suitable for existing model of desert coolers of capacity upto 5000 cum/hr 39 aj) pvc insulated and pvc round sheathed three core, 1.5 sqmm copper conductor heavy duty cables for voltage grade upto 1100 volts 40 ak) pvc insulated and pvc round sheathed three core, 2.5 sqmm copper conductor heavy duty cables for voltage grade upto 1100 volts 41 al) single pole and neutral enclosure mcb db alongwith a 20 amps rated sp mcb,two pin plus earth plug and socket, 230 volts, 50 hz 42 am) plug top, 3 pin, 16 amps, single phase, 230 volts 43 an) ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule of size 15mm dia bore suitable for water coolers. 44 ao) pvc connection 15mm size with ptmt nuts of length 600mm 45 ap) chromium plated push button tap of size 15mm dia bore suitable for water coolers 46 aq) stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe. 47 ar) pvc waste water pipe of size 32/40mm dia 48 as) pvc insulated and pvc round sheathed four core, 2.5 sqmm copper conductor heavy duty cables for voltage grade upto 1100 volts 49 at) supply and fix in repair mcb sp 20 amps, 240v suitable for split type air conditioner upto 2 tr 50 au) supply and fix in repair metal clad ac male and female socket suitable for air conditioner upto 2 tr 51 av) supply and fix in repair evaporative coil suitable for air conditoner upto 2 tr capacity 52 aw) supply and fix in repair condensing coil suitable for air conditoner upto 2 tr capacity 53 taking out the burnt fan motor from the following cooling appliances, cutting and removing the winding and material & labour for rewinding with super enamelled copper wire of existing gauge, applying insulation varnish, pre heating and binding with empire tubes, crimple sheet etc. as required for rewinding complete all as specified and directed by engineer-in-charge:- 54 a) window/ split type air conditioner of capacity upto 2.0 tr 55 b)evaporative type desert cooler of capacity upto 5000 cum/hr 56 material & labour for filling up & charging of environmentally suitable refrigerant for following cooling appliances after leak testing the complete system and making good by bracing including replacement of filter strainer copper and capillery tube of suitable size complete all as specified and directed by engineer-in-charge. 57 a) window type air conditioner of capacity upto 2.0 tr 58 b) split type air conditioner of capacity upto 2.0 tr 59 c) water cooler of capacity upto 150 ltrs 60 d)refrigerator/deep freezer of capacity upto 310 ltrs 61 taking out defective pcb control unit of split type air conditioners invertor/ non invertor type of capacity upto 2.0 tr and rectifying the defects by replacing unserviceable ics, diodes, capacitors, resistors etc and refing back and testing on completion complete all as specified and directed by engineer-in-charge. 62 takingdown carefully the indoor and outdoor unit alongwith voltage stabilizer of split type air conditioner of capacity upto 2.0 tr by disconnecting all electrical connections, suction and discharge lines fromits installed position and shifting to another location where directed and installing the indoor and outdoor units alongwith stabilizer at specified location and connecting all the electrical, suction and discharge lines and testing on completion for proper functioning complete all as specified and directed by engineerr-in-charge. 63 material and labour for making hole in to the wall , stone masonary/brick work up to 80mm dia for installing/fixing of split type ac with and including making the surface smooth with cement mortar complete all as specified and directed. 64 supply and fixing pre-fabricated ms bracket assembly (set of two) complete with nuts and bolts of suitable size for fixing of split type ac outdoor unit complete all as specified and directed. 65 supply and fixing of indoor unit of air conditioner upto 2.0 tr capacity complete all as specified and directed by engineer-in-charge. 66 supply and fixing of outdoor unit of air conditioner upto 2.0 tr capacity including compressor complete all as specified and directed by engineer-in-charge. 67 taking down the stabilizer any type of capacity 4/5 kva carefully from the installed position, dismantling the complete unit, cleaning all the components with makingrepair/replacement of minor parts of costing not more then rs 500 andreassembling the complete unit and re-installing in its original position and testing on completion complete all as directed by engineer-in-charge. 68 taking down the stabilizer any type of capacity 2/3 kva carefully from the installed position, dismantling the complete unit, cleaning all the components with makingrepair/replacement of minor parts of costing not more then rs 400 andreassembling the complete unit and re-installing in its original position and testing on completion complete all as directed by engineer-in-charge. 69 supply only ac remote suitable for ac 1.5/2 tr window/split type (invertor/ non invertor). note- material will be supplied as existing model or sample given by engr-in-charge. 70 supply and fixing of extra heavy duty remote battery 1.5 volt complete . 71 m&l for sub main wiring surface/recessed as required with two single core 6 sqmm pvc insulated and unsheathed copper conductor, multistranded 1100 volts grade through and including non metalic rigid pvc conduit including 6 sqmm copper conductor multistranded pvc insulated and unsheathed wire as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing u/s sub main wiring and making good the disturbed surface to match with the existing all as specified and directed.( note :- two run of 6 sqmm cable and one run of earth wire and one run of non metalic conduit shall be measured and paid as 01 rm. 72 m&l for sub main wiring surface/recessed as required with two single core 4 sqmm pvc insulated and unsheathed copper conductor, multistranded 1100 volts grade through and including non metalic rigid pvc conduit including 4 sqmm copper conductor multistranded pvc insulated and unsheathed wire as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing u/s sub main wiring and making good the disturbed surface to match with the existing all as specified and directed.( note :- two run of 4 sqmm cable and one run of earth wire and one run of non metalic conduit shall be measured and paid as 01 rm.

Tender Result Details

Bidder List
1. haasith constructions
2. ms enterprises
3. m/s kamal kee engineers work
4. universal refrigeration and engineering company
Contract Date 27-01-2026
Contract Value 21.77 Lakhs
Contractor Name haasith constructions