Tender Results

Tender Details

BRR 8485817
Tendering Authority Municipal Corporation
Tender No E TENDER NOTICE NO. 634 / 2025-26
Tender ID 2025_JCMCJ_1240481_1
Tender Brief providing and installation of spares rectification of electrical and mechanical rectification works of pump houses and 33 kv substation- 1 provoding and erecting heat shrinkable out door termination kit for 33 kv xlpe ht cable 300 sq.mm.with necessary material. 2 provoding and erecting heat shrinkable out door termination kit for 33 kv xlpe ht cable 95 sq.mm.with necessary material. 3 providing
City jalgaon
State Maharashtra
Tender Value Ref. Documents
Due Date 11-11-2025

Work Detail

providing and installation of spares rectification of electrical and mechanical rectification works of pump houses and 33 kv substation- 1 provoding and erecting heat shrinkable out door termination kit for 33 kv xlpe ht cable 300 sq.mm.with necessary material. 2 provoding and erecting heat shrinkable out door termination kit for 33 kv xlpe ht cable 95 sq.mm.with necessary material. 3 providing and erecting heat shrinkable outdoor termination kit for1.1 kv (e) xlpe cable 70 to 120 sq. mm. with necessary material. 4 supply and installation of l.t. out door 3/3.5 c, 70 to 120 sq mm cable joint for cables from auxiliary transformer to panels. 5 repairing of 33 kv existingisolator along with required spares & hardware’s with alignment for smooth operations 6 repairing of 33 kv existing ab switch including required spares & hardwares with alignment for smooth operations. 7 supply and installation of 33 kv horn gap fuses. 8 supply and installation of d.o. fuse 50 amps. 9 supply and installation of 33 kv, lasingle post. 10 supply and installation ofpost insulator. 11 supply & installation of 33 kv outdoor pt 12 dismantling of existing damaged 33 kvpt 13 supply and installation of 33 kv outdoor ct 14 repairing and tightening of allpost, disc, pin insulator and cleaning by ctc 15 tightening of all conductors, aluminium lugs and hardwaresin sub station as preventive maintenance to avoid faults 16 transformer 33 kv/3.3 kv, 3000 kva overhauling, bucholz relay, bdv test, ppm test, tightening of all 33 kv bushing and conductors removing air from bucolz relay, cleaning of all bushing with ctc. attending leakages if any. 17 supply & installation of buchloz relay for 33 kv out door transformer. 18 supply & installation of breather with silica jel for 33 kv outdoor transformer. 19 auxiliary transformer 33 kv /440 volts complete preventive maintenance, tightening of all bushing, gaskets, conductors and cable terminations, earthing etc. 20 oil filtration of transformer at required place with all test reports. 21 hiring of generators for necessary works including transportation. 22 supply of insulating transformer oil as per requirement for top up of transformers at required place. 23 overhauling of 33 kv out door vcb.all control wiring tightening, spring charging motor testing, earthing tightening etc. 24 supply and installation of indoor cable joint for 3.3 kv, 500 hp motor, coppermulti strandfor ht motor. dismantailing of existing burnt out / heated cable joint, cleaning cable by ctcpreparing new joint and ht taping and meggering(motor terminal). 25 supply and installationof indoor cable termination kit for 3.3 kv, 500 hp motor, coppermulti strandfor ht motor. dismantailing of existing burnt out / heated cable joint, cleaning cable by ctcpreparing new joint and ht taping and meggering(incomer cable terminal). 26 supply and installation of cable joint of 3.3 kv h t motor panels. cleaning by ctc to clean cable and lugs for carbon free particle’s, re-taping by ht tape and meggering. 27 supply & installation of hthrc fuse 3.3 kv/50 amps capacity with barrel for capacitor 28 500 hp, 3.3 kv, ht motor complete overhauling. shifting motor from foundation by disconnecting cable, pulley etc. dismantailing/ taking out rotor from stator. ht warnishing to rotor and stator by heating process inspection of bearings, end cover bearing housing etc. 29 providing & fitting bearing to the 500 hp, 3.3 kv, motor de side including necessary fixtures etc. complete. 30 providing & fitting bearing to the 500 hp, 3.3 kv, motor nde side including necessary fixtures etc. complete. 31 workshop work for filling weared out bearing housing & shaft of motor. 32 preventive maintenance of motor. inspection of bearings, cable joints, foundation bolts tightness, cleaning of cooling system greasing to de and nde bearings. 33 alignment of pump to motor after installation of new/ repaired pump/couple set. 34 alignment of motor to pump after installation of new/ repaired motor set. 35 removing 500 h.p. 375 kw. pump set(kirloskar make) of existing old split casing pump from raw water pumping station for repairing purpose. 36 fitting impeller mounted shaft with alignment in bottom casing of pump including necessary fixtures etc. 37 workshop work of bearing holder & fitting to de, nde side, weared shaft at gland packing location, weared shaft at coupling side of the pump including necessary fixtures etc. including shifting, loading and unloading of pump. 38 rewinding motor of eot crane. 39 repairing panel board of eot crane with required accessories. 40 providing and fitting remote of eot crane. 41 providing & fitting check nut & lock nut for bearing of the pump including necessary fixtures etc. complete. 42 providing & fitting set of gaskets to the pump including necessary fixtures etc. complete. 43 providing & fitting set of fasteners to the pump including necessary fixtures etc. complete. 44 providing & fitting gland packing to the pump including necessary fixtures etc. complete. 45 supply & installation of rubber bushes with nut bolts as per requirement of coupling. 46 providing & fitting bearings to the pump including necessary fixtures etc. complete. 47 providing new couple set with rubber bushes, nut, bolts & studs suitable for pump & motor of 500 hp complete with required bore and key size workshop work. 48 installation at pump house couples with rubber bushes nut, bolts & studs for pump and motor. 49 providing and fitting of cooling tube sets and valves with necessary fixtures. 50 eot crane maintenance work, inspection of main drum, motors, panel, relays, both rails etc. 51 replace faulty or burnt mcb in eot crane panel 52 overhauling ofmotors with replacement of bearings for eot crane 53 supply and installation of closing and tripping coil of outdoor vcb. 54 supply and installation of spring charging motor. 55 repairing of spring charging motor. 56 servicing of vcb with rust proof chemical compound, for smooth operations and trolley alignment with required acessories. 57 repair of indoor vcb, for smooth operations with required spares and acessories. 58 supply & installation of closing / tripping coil of indoor vcb. 59 supply & installation of earth fault relay. 60 supply & installation of breaker control switches. 61 supply & installation ofammeter 3.3 kv. 62 supply & installation of ammeter selector switch. 63 supply & installation of 3.3 kvvoltmeter. 64 supply & installation of 3.3 kvvoltmeter selector switch. 65 lt panel - supply and replacement of faulty/ burnt out spares 66 supply & installation ofammeter440 volts 67 supply & installation of ammeter selector switch 440 volts 68 supply & installation of440 v voltmeter. 69 supply & installation of 440 v voltmeter selector switch. 70 repairing of all vcb panel doors with supply of required spares 71 battery charger panel -supply and installation of burnt out spares. 72 repairing / preventive maintenance of battery charger panel. 73 preventive maintenance of 55 batteries. 74 repair & maintenance of earthing system in sub station yard for continous watering, cable connections and checking earth value. 75 transformer 11 kv /440 volts complete preventive maintenance, tightening of all bushing, gaskets, conductors and cable terminations, earthing etc. 76 supply & installation of breather with silica jel for 11 kv/440 volts outdoor transformer. 77 provoding and erecting heat shrinkable indoor termination kit for 1.1 kv xlpe lt cable upto 120 sq.mm.with necessary material at required place. 78 providing and erecting heat shrinkable outdoor termination kit for 1.1 kv 3 corexlpe cable 70 to 120 sq. mm. with necessary material at required place. 79 preventive maintenance of 35 hp submercible pump delivery system with supply of required rubber sheet, packing, set of fasteners etc including dismantling & fitting trial etc. 80 preventive maintenance of 50 hp submercible pump delivery system with supply of required rubber sheet, packing, set of fasteners etc including dismantling & fitting trial etc. 81 preventive maintenance of 75/80 hp centrifugal/vt pump delivery system with supply of required rubber sheet, packing, set of fasteners, foot valve, etc including dismantling & fitting trial etc. 82 preventive maintenance of 120 hp submercible pump delivery system with supply of required rubber sheet, packing, set of fasteners etc including dismantling & fitting trial etc. 83 preventive maintenance of 75 hp vt motor and pump bowl assembly with supply of required bearings, impeller, gland packing, etc including dismantling fitting with allignment & trial etc. 84 preventive maintenance of 75/80 hp centrifugal pump with supply of required bearings, work shop work, gland packing, etc including dismantling & fitting trial etc 85 supply & installation fuses for starter of 35 hp panel 86 supply & installation fuses for starter of 50 hp panel 87 supply & installation fuses for starter of 75 hp panel 88 supply & installation fuses for starter of 120 hp panel 89 supply & installation of ats for 35 hp control panel 90 supply & installation of ats for 50 hp control panel 91 supply & installation of ats for 75 hp control panel 92 supply & installation of ats for 120 hp control panel 93 preventive maintenance of ats & thermostat for starter panels including top up of oil, replacement of gaskets, dismantling, tightening,cleaning, fitting and trial. 94 supply & installation of mccb for 35 hp motor starter panel. 95 supply & installation of mccb for 50 hp motor starter panel. 96 supply & installation of mccb for 75 hp motor starter panel. 97 supply & installation of mccb for 120 hp motor starter panel. 98 providing and fitting thrust bearing to motor of vt pump. 99 providing & fitting check nut & lock nut for bearing of the vt pump including necessary fixtures etc. complete. 100 workshop work of weared shaft at impeller, bearing, joints gland packing location, weared shaft bowl bushing including necessary fixtures etc. including dismantling, shifting, loading, unloading and fitting with allignment of vt pump. 101 preventive maintenance of starter panel to rectify and repair the damage incurred due to winding fault,electricity surge, etc including cleaning of terminals, contactor coil and components with ctc. 102 rewinding of motor set including seals, bearings workshop charges, dismantling and fitting,etc for 35 hp submercible pump. 103 rewinding of motor set including seals, bearings workshop charges, dismantling and fitting,etc for 50 hp submercible pump. 104 rewinding of motor set including seals, bearings workshop charges, dismantling and fitting,etc for 75 hp centrifugal pump. 105 rewinding of motor set including bearings workshop charges,dismantling and fitting,etc for 75 hp vt pump. 106 rewinding of motor set including seals, bearings workshop charges, dismantling and fitting at site for 120 hp submercible pump. 107 shifting of motor from site to workshop/factory for rewinding including loading, unloading on vehicle with necessary machinary and manpower. 108 removing and re-erection of submercible pump including fitting of existing rubber gaskets, set of fasteners, cables, allied machinary, manpower. 109 supply of lithium soap base bearing grease.

Tender Result Details

Bidder List
1. e solution services
2. mahajan brothers
3. shree bhairav electro mech works
Contract Date 09-12-2025
Contract Value 49.98 Lakhs
Contractor Name e solution services

Information Source

https://mahatenders.gov.in

View Original Notice/Document

Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.