Menu
    

Expansion Valves Tenders from India

2 Expansion Valvestenders are published by various Tendering Authorities & Private companies. 2 live Tender for Expansion Valves are available in Expansion Valves Tender section You can further filter Expansion Valves tenders by Tender Value, Tender Submission Date or Project Location.

Search Result
Tender 1 - 2 of 2 from India
Sort By:
Closing Date
Jun32016

TDR: 9733333
Location: Tamil Nadu - India
Tender Value: 6 Lakhs

Supply, Installation , Testing & Commissioning Of 5.5 Tr Ductable Type Air-Conditioning Systems With Proper Condensing Units To Work In Conjunction With Dx Double Skin Air- Handling Unit And Other Necessary Accessories As Listed -01. Air Cooled Condensing Units 5.5 Tr Capacity Comprising Of Scroll Compress, Air-Cooled Condenser And Micro Controllers. ( All The Coils Should Be In Copper ) 02. Double Skin Ceiling Suspended Air Handling Unit Of 5.5 Tr Capacity Comprising Pre-Filters, 6-Row Dx Cooling Coil, Thermostatic Expansion Valves And Didw Blower And Motor With Mixing Box . 03. Copper Refrigerant Piping Interconnecting Each Indoor And Outdoor Units – 5 / 8”. 04. Copper Refrigerant Piping Interconnecting Each Other Indoor And Outdoor Units 7 / 8”. 05. Initial Charge Of R-22 Refrigerant Gas. 06. Thermostatic Expansion Value And Catch All Drier. 07. Flexible Canvass Connection 08. Gss Supply Air Ducting – 22G 09. Gss Supply Air Ducting – 24 G 10. Acoustic Insulation Of The Ducting With 10 Mm Thick Open Cell Nitrile Rubber. 11. Thermal Insulation For The Supply Air Ducting Carried Out Of 6 Mm Thick Aluminum Foil Faced Xlpe. 12. Powder Coated Aluminum Tile Replacement Diffusers. 13. Insulated Flexible Ducts. 14. Volume Control Dampers Out Of Gss Construction. 15. Sound Attenuators For The Supply And Return Ducting. 16. Underdeck Insulation Carried Out Of 50 Mm Thick Expanded Polystyrene Slabs. 17. Ms Painted Frame Work For Locating The Outdoor Unit. 18. Wall Mounting Digital Thermometer 19. Interlink Cables / Control Wires And Wiring Work For Indoor And Outdoor Units 20. Ahu Electrical Starter Panel 21. Cabling, Earthing And Terminations 22. Microprocessor Control Panel Connecting Work 23. Drain Piping Carried Out Of Hard Pvc Pipes 24. Air Duct Work , Fixing Of Grille, Diffusers - As Required 25. Design, Erection, Testing And Commissioning Of The Units 26. Including Of All Minor Civil Work Related With Air Conditioner Installation Work 27. Transportation Close


Closing Date
Mar182016

TDR: 9326297
Location: Maharashtra - India
Tender Value: Ref. Document

Supply Of Item-1 Leaktesting With Nitrogen Gas, Arresting Leakege, Vaccumising & Gas Charging With Fr22 Gas In System, Testing And Commisioning Of Split Airconditioners As Per Standard Procedure. 2 Leaktesting With Nitrogen Gas, Arresting Leakege, Vaccumising Gas Charging With Fr22 Gas In System, Testing And Commisioning Of Voltas Maktjwindow Airconditioners As Per Standard Procedure. 3 Leak Testing With Nitrogen Gas, Arresting Leakege, Vaccumising Gas Charging With Fr22 Gas In System, Testing And Commisioning Of 4 Ton Tower Airconditioners As Per Standard Procedure. 4 Inspecting The Defective 4 X 14 Ton Voltas Make Acplant Package Units For Leakages, Checking Of Expansion Valves, Hp / Lpcut Out, Driers Etc. To Find Out Leakages, Pressurise The System With Nitrogen With Standard Procedure For Carrying Out Leak Test In Acplants And Keep It For 24 Hours. If Any Leakages Observed It Is To Be Arrested By Flushing Out Nitrogen From System And Then Arrest The Leakage By Brazing And Again Check For Any Leakage. Then Vaccumising, Gas Charging With F22gas In System, Testing And Commissioning Of Air Conditioner Plant Units. 5 Inspecting The Defective 2 X 10 Ton Blue Star Make Acplant Package Units For Leakages, Checking Of Expansion Valves, Hp / Lpcut Out, Driers Etc. To Find Out Leakages, Pressurise The System With Nitrogen With Standard Procedure For Carrying Out Leak Test In Acplants And Keep It For 24 Hours. If Any Leakages Observed It Is To Be Arrested By Flushing Out Nitrogen From System And Then Arrest The Leakage By Brazing And Again Check For Any Leakage. Then Vaccumising, Gas Charging With F22 Gas In System, Testing And Commissioning Of Air Conditioner Plant Units. Close



Sample Tenders